Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56633947

Tender For Repair/Maint Of Internal Electrification, Eartihing, Lightening Conductor And Allied Work At Otm Accn Of 509 Abw, Aats, 411 Engr Regt, 801 Ta Agra Fort & 6 Para Under Ge (East) Agra

Issued by Statutory Bodies & Commissions/Committees · Agra, Uttar Pradesh
Tender Value
30 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
2 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal Electrification, Eartihing, Lightening Conductor And Allied Work At Otm Accn Of 509 Abw, Aats, 411 Engr Regt, 801 Ta Agra Fort & 6 Para Under Ge (East) Agra

BOQ

Name of Work:- REPAIR/MAINT OF INTERNAL ELECTRIFICATION, EARTIHING, LIGHTENING CONDUCTOR AND ALLIED WORK AT OTM ACCN OF 509 ABW, AATS, 411 ENGR REGT, 801 TA AGRA FORT & 6 PARA UNDER GE (EAST) AGRA
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified and directed.
2M&L for Point wiring complete with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, MS sunken boxes duly painted with one coat of red oxide and one coat of black paint not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. (a) One light/Fan/Exhaust Fan point controlled by one switch.
3All as per item No 2 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board.
4All as per item No 2 above but one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches.
5All as per item No 2 above but One Bell/Buzzer point controlled by one push button on same board with other switches or independent.
6All as per item No 2 above but One light point controlled by two 2 way switches.
7All as per item No 2 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let/ 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed
8M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in existing PVC concealed conduit with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard unsheathed copper wire for continues earth, including cutting and chasing of wall surface for sunken box and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. One light /fan/Exhaust Fan point controlled by one switch
9All as per item No 8 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board.
10All as per item No 8 above but one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches.
11All as per item No 8 above but One Bell/Buzzer point controlled by one push button on same board with other switches or independent.
12All as per item No 8 above but One light point controlled by two 2 way switches.
13All as per item No 8 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let/ 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed
14S&F switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
15S&F Switch piano flush button single pole one way 15 amps 240 Volts with polycarbonate body complete all as specified and directed.
16S&F Switch piano flush button single pole two way 6 amps 240 Volts with polycarbonate body complete all as specified and directed.
17S&F socket 5 amps 3 pin flush type, 240 volts. with polycarbonate body com-plete all as specified and directed.
18S&F socket outlet, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
19S&F Bell push, flush type, 5 amp, complete all as specified and directed.
20S&F in repair call bell, Ding dong type, 230 volts AC single pole complete all as directed.
21S&F ceiling rose , 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals all as specified and directed.
22S&F in repair stepped type electronic fan regulator switch/socket type ISI marked on the existing phenolic laminated sheet etc. as required, complete all as specified and directed.
23S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20W) luminaire lumen >2000 lm, system efficiency of >100 lumens /W, with Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
24S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >100 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
25S&F in repair LED luminaire 595 mm x 595 mm, 36 watt, 220 V AC, 6500 K surface/ recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting complete all as specified and directed.
26S&F in replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.00 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of security light.
27M&L in repair for Submain wiring with two single core FRLSH 4 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified.Note:- Two single core FRLSH 4 sqmm copper conductor, one run PVC conduit and one run of FRLSH 4 sqmm earth wire shall be considered & measured as one unit.
28M&L in repair Submain wiring with two single core FRLSH 6 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connec-tion to earth dolly complete all as specified Note:- Two single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
29M&L in repair Submain wiring with two single core FRLSH 10 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 10 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connec-tion to earth dolly complete all as specified. Note:- Two single core FRLSH 10 sqmm copper conductor, one run PVC conduit and one run of FRLSH 10 sqmm earth wire shall be considered & measured as one unit.
30S&F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, complete all as specified and directed.
31S&F in repair sheet metal enclosure Vertical TPN DB 4 Way double door As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 43 DB's, suitable for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing including taking down old unsv MCB DB and MCBs complete all as specified and directed.
32S&F in repair sheet metal enclosure MCB distribution board. TPN 415 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB & taking down and making good distributed wall surfaces to match with existing specification all as specified and directed.
33S&F MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 4 way ISI marked, IP-43 including taking down old unsv MCB DB and MCBs complete all as specified and directed.
34S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 8 way ISI marked, IP-43 including taking down old unsv MCB DB and MCBs complete all as specified and directed.
35S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 12 way ISI marked, IP-43 including taking down old unsv MCB DB and MCBs complete all as specified and directed.
36S&F in repair MCB TPN 40-100 Amp rating 415V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection complete all as specified and directed.
37S&F in repair MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection complete all as specified and directed.
38S&F in repair MCB SPN 40-63 Amp rating 240V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection complete all as specified and directed.
39S&F in repair one way sheet metal enclosure suitable for MCCB, 4 pole, 160 Amps, As per IEC 61439-3 complete all as specified and directed.
40S&F in repair MCCB 4 pole, 160 Amps, 50 Hz, Icu=16 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 80% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
41M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , con-nected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed.NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor complete all as specified and directed.
42Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chas-es or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated sit-uation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
43M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanised iron strip 25x4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
44S&F in repair air terminal single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed.
45M&L for test point terminal block made of gun metal or phosphoras bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long n.exc height head screw complete all s specified and directed
46S&F aluminium strip 25x3.15 mm with saddles and fixing screw etc for roof and down conductors and above ground complete all as specified and directed.
47M&L for Pre-cast cement concrete block masonary with solid blocks exc 30 cm in width and setting in mortor complete 1:2:4 type B-1 (20 mm graded aggregated) for fixing GI pipe for air termination rods) complete all as specified and directed.
48S&F GI Tubes, 'Medium grade' 40mm dia complete to walls and ceilings complete all as specified and directed.
49S&F porcelain insulator of required size not exceeding 10cm long with two Nos hole each on both end for fixing properly with nuts and bolts on wall of building for separated to lightening conductor or earthing strip from building all as required at site complete all as specified and directed. Note:- The distance between two insulators fixed on wall not more than 1 Mtr length complete all as specified and directed.
50S&F in repair 15W ultra slim recess-mounting round shaped LED downlighter made of polycorbonate with high efficient LEDs & Glare free opal diffuser, IP20 and system Efficacy of 100lm/W complete all as specified and directed.
51S&F in repair 15W ultra slim recess-mounting square shaped LED downlighter made of polycorbonate with high efficient LEDs & Glare free opal diffuser, IP20 and system Efficacy of 100lm/W complete all as specified and directed.
52S&F LED 10 watts bollard Mushroom shape warm white with robust IP 65 rating design, Height-0.80m and efficient light distribution including light fitting fixing and making PCC block foundation of size 250x250x250mm with concrete cement and connecting the fittings on PCC foundation block with suitable size of fastner complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of Bollard light.
53M&L for Circuit/Sub main wiring with two single core FRLSH 1.5 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall, floor (Min 250mm depth) or ceiling for sub main connection including FRLSH 1.5 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly and making good disturbed surfaces of walls, floors, etc complete all as specified. Note:- Two single core FRLSH 1.5 sqmm copper conductor, one run PVC conduit and one run of FRLSH 1.5 sqmm earth wire shall be considered & measured as one unit.
54S&F in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp.
55S&F in repair Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (Approx 4 feet 20W) luminaire complete all as specified and directed.
56S&F in repair LED Bulb 12 watts CDL, E-27, 6500K (Thread type) complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56633947
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 14-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Internal Electrification, Eartihing, Lightening Conductor And Allied Work At Otm Accn Of 509 Abw, Aats, 411 Engr Regt, 801 Ta Agra Fort & 6 Para Under Ge (East) Agra
Basic Detail
Tender No 9906/E8
Bidding Type Tender
Location
City Agra
State Uttar Pradesh
Key Dates
Publish Date 24 Jul 2026
Submission Date 14 Aug 2026
Open Date 22 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
89571c54-0f13-45f4-b7fa-8f877bf9be54.html
BOQ_874327.xls
PS9906.pdf
Tender9906.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

89571c54-0f13-45f4-b7fa-8f877bf9be54.html

xls

BOQ_874327.xls

pdf

PS9906.pdf

pdf

Tender9906.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders