Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56633883

Tender For Addn/Altn And Improvement To Electric Supply, Distr Cable And Provision Of Security Light At Zone-Iv & Vi Of Dharmund Garrison Fy 2026-27 Under Age (I) Bhalra

Issued by Statutory Bodies & Commissions/Committees · Nagrota, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Aug 2026
18 days left
EMD
19458
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagrota → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Addn/Altn And Improvement To Electric Supply, Distr Cable And Provision Of Security Light At Zone-Iv & Vi Of Dharmund Garrison Fy 2026-27 Under Age (I) Bhalra

BOQ

Name of Work:- ADDN/ALTN AND IMPROVEMENT TO ELECTRIC SUPPLY, DISTR CABLE AND PROVISION OF SECURITY LIGHT AT ZONE-IV & VI OF DHARMUND GARRISON FY 2026-27 UNDER AGE (I) BHALRA
Sl. No. Item Description
1Supply & fixing street light fitting of minimum 60 Watt LED made up of pressure die cast aluminum hosing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device including taking down old unserviceable street light fitting complete all as specified and directed by Engr-in-Charge . Make : Wipro/Havells/Syska
2Supply and erecting true vertically GI hot dipped octagonal pole 4 Mtr height, silver colour, 70 mm top 130 mm bottom 3 mm thickness, base plate 200 x 200 x 12 mm, GI 64 micron, M16 x 600 en 8 grade foundation bolt and 01 Mtr arm for installation of street light, including provision of 04 Nos Anchor fastner/Nut botls at base plate and concrecte for stability of GI octagonal pole complete all as specified and directed by Engr-in-charge.
3S & F pole box for street light dust and vermin proof make Sintex model GSJB 3020 4 way connection on epoxy insulators incl one MCB SP C series 06 amps 10 KA capacity for Security light connection including suitable clamps and provision of 3 core 1.5 sq mm copper wire from loop box to security light for connection complete all as specified and directed by Engr-in-Charge
4Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foudation of poles/cable,stay assy etc and getting out any type of soil complete all as specified and as directed by Engineer-in-Charge
5Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge
6Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed by Engr-in-Charge
7M&L for sand cushning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed by Engr-in-Charge
8Supply and lay well burnt brick class B as protection to cable in cable trenches complete all as specified and directed by Engr-in-Charge
9Material and labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole, including necessary form work complete all as specified and Engineer-in-Charge.
10Fabricate, Supply install test and commissioning of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed by Engr-in-Charge and comprising of the following
11(a) Bus bar Aluminium - 400 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. (b) MCCB 200 Amps, 50 Hz, 415 V with rupturing capacity 36 KA, Adjustable Thermal Mangnetic range -02 Main incomer(c) On load change over switch 200 Amps, 415 Volts, open execution-01 (d) MCCB 100 Amps 3 pole 16 KA, with adjustable thermal magnetic range as out going- 01 No. (e) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 03 Nos. (f) MCB TP 63 Amps, 10 KA, 'C Series-03(g) MCB SPN 40 Amps, 10 KA, 'B' Series-12
12Supply and fixing MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with rupturing capacity 36 KA complete with sheet metal enclosure and extended terminals complete all as specified and directed by Engr-in-Charge
13Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 95 sq mm complete all as specified and directed by Engr-in-Charge
14Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 2 core 10 sq mm complete all as specified and directed by Engr-in-Charge
15Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 50 sq mm complete all as specified and directed by Engr-in-Charge
16Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 25 sq mm complete all as specified and directed by Engr-in-Charge
17Supply and fix 1100 volts grade heavy duty cable with PVC insulated aluminiuum stranded conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection twin core 10 sqmm solid conductor all as specified and directed by Engr-in-Charge.
18Supply and fix 1100 volts grade heavy duty cable with PVC insulated aluminiuum stranded conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection twin core 16 sqmm solid conductor complete all as specified and directed by Engr-in-Charge
19Supply and fixing TPN DB's 4 way vertical type 415 V, double door suitable for housing of 100 Amps MCCB as main incoming complete all as specified and directed by Engr-in-Charge
20Supply and fixing MCCB 100 Amps, 4 Pole, 16 KA, fixed type, suitable to be fixed in 4 way TPN DB complete all as specified and directed by Engr-in-Charge
21Suply and fixing 240 V, 10 KA, 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity SP 40 Amps in the MCB DB complete with connection testing and commissioning.
22S & F sub main wiring for circuit of size 10 sq mm 2 core (FRLS) alongwith earth wire of 10 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit of suitable size complete complete all as specified and directed by Engr-in-Charge (FOR SPN DB's)
23All as per item No. 21 above but of 6 sq mm 2 core alongwith earth wire 6 sq mm single core complete all as specified and directed by Engr-in-Charge
24All as per item No. 21 above but of 4 sq mm 2 core alongwith earth wire 4 sq mm single core complete all as specified and directed by Engr-in-Charge
25All as per item No. 21 above but of 2.5 sq mm 2 core alongwith earth wire 2.5 sq mm single core complete all as specified and directed by Engr-in-Charge
26S & F in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar complete all as specified and directed by Engr-in-Charge
27S & F in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar complete all as specified and directed by Engr-in-Charge
28S & F in repair MCB DB double door SPN 4 Way with 200 Amps rated copper bus bar complete all as specified and directed by Engr-in-Charge
29S & F in repair MCB DB double door SPN 2 Way with 200 Amps rated copper bus bar complete all as specified and directed by Engr-in-Charge
30Supply and fixing in repair 5-32 amp MCB SP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge
31Supply and fixing in repair 40A to 63A MCB SPN amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning including taking down all as specified and directed by Engr-in-charge
32M & L Earthing complete for sub station equipments with galvanized steel earth pole electrod of size 600x600x6.3mm thick burried directly in the ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below the ground level, connected to galvanised iron strip 32 x 6mm by means of nuts, bolts,check nuts and washers of galvanised or steel all as specified or shown in electrical plate No. 3 of SSR-2009( Part-l), including ncessary earth work and excavation in any strata, GI pipe 40mm dia light grade for protection of galvanised iron earthing strip upto 7.5 mtrs, including concrete chamber of PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) having copping in PCC (1:3:6) Type C-1using 20mm graded stonr aggregate. Intemal surface of concrete chamber shall be plastered with 12mm thick cement mortar (1;4) and 50mm thick RCC cover in proportion (1:2:4) type B-1using 20mm graded stone aggregate, reinforced with 8mm dia tor bar@ 80mm c/c both ways and charcoale dust common salt etc.,funnel testing point, 8 mesh per liner inch, including test point , testing, complete . (04 Nos for transformer, 02 Nos for APFC panel, 02 Nos for Main receiving panel, 02 Nos for 02 Pole structure, 04 Nos lightening arrestor at 2 pole structure, 02 Nos for DG set, 01 Nos for street light poles)
33Supply & fix Bus bar Panel, Size:0.8x0.4x0.4 Mtr, Kisok outdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 1.4 mm thick MS Sheet CRCA on angle iron 30X30X4mm frame of size suitable to incorporate following accessories with front opening doors, locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of Bus bar chamber comprising 4 Nos Aluminium strip bus bars PVC insulated made of aluminium strip of size suitable for 200A current. PVC sheathed with colour coding.
34Cutting existing road surfaces or hard standing 0.45 mtr depth and 0.3 mtr width (22 CM thick comprising bituminous topping) for laying of pipes/cables and making good to the disturbed surfaces to match with existing complete all as specified and directed. Note : Rate quoted by the contractor deemed to be inclusive of PCC 1:2:4 to be required to making good the disturbed surface to match with existing complete all as specified and directed by Engr-in-Charge
35Supply and fixing in replacement rigid non-metallic PVC casing & caping 25 MM windth exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock, nuts, saddles, pipe hooks etc. complete all as specified and directed by Engr-in-charge
36Supply and fixing in replacement rigid non-metallic PVC conduit 25 MM DIA exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock, nuts, saddles, pipe hooks etc. complete all as specified and directed by Engr-in-charge
37Supply and fixing in replacement rigid non-metallic PVC conduit 40 MM DIA exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock, nuts, saddles, pipe hooks etc. complete all as specified and directed by Engr-in-charge
38Supply and fix \\"ON load\\" four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 200 amps complete with steel sheet enclosure with suitable size nut/bolts and complete all as specified and directed by Engr-in-Charge . Make - Havells/L&T/ABB Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56633883
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 13-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn/Altn And Improvement To Electric Supply, Distr Cable And Provision Of Security Light At Zone-Iv & Vi Of Dharmund Garrison Fy 2026-27 Under Age (I) Bhalra
Basic Detail
Tender No AGE (I)/Bhalra- /2026-27 (NIT No. 42 of 2026-27)
Bidding Type Tender
Location
City Nagrota
State Jammu and Kashmir
Key Dates
Publish Date 23 Jul 2026
Submission Date 13 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 19458
Exemption Not Available
Document List
BOQ_874088.xls
d620e19e-2d6a-4096-be0b-65baaeb32f98.html
Tender42.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_874088.xls

html

d620e19e-2d6a-4096-be0b-65baaeb32f98.html

pdf

Tender42.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender