Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56633876

Tender For Construction Of 02X25mt (Nec) Ac Igloos At Ferozepur Mil Stn (Tender Id : 2026_Mes_780243_1)

Issued by Statutory Bodies & Commissions/Committees · Jalandhar, Punjab
Tender Value
7.65 Crore
Estimated cost
Bid Submission
31 Aug 2026
19 days left
EMD
7.08 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 02X25mt (Nec) Ac Igloos At Ferozepur Mil Stn (Tender Id : 2026_Mes_780243_1)

BOQ

Name of Work:- CONSTRUCTION OF 02X25MT (NEC) AC IGLOOS AT FEROZEPUR MIL STN (Tender ID : 2026_MES_780243_1)
Sl. No. Item Description
1Note:- Please refer Schedule 'A' Notes given on serial page No. 20 to 26 of tender documents.
2LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
3Lump sum price worked out by the contractor for BUILDING WORK as listed in Schedule 'A' Part-I brought forward from serial page No.27.
4Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-II brought forward from serial page No.28.
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 29 to 30.
6Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 31.
7Lump sum price worked out by the contractor for ROAD & PATH WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 32 & 33.
8Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 34.
9Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS as listed in Schedule 'A' Part-VII brought forward from serial page No. 35 & 36.
10Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule 'A' Part-VIII brought forward from serial page No. 37.
11Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 38 to 41.
12Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 42.
13Lump sum price worked out by the contractor for FIRE ALARM WORK as listed in Schedule 'A' Part-XI brought forward from serial page No. 43 to 45.
14Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORK as listed in Schedule 'A' Part-XII brought forward from serial page No. 46.
15Lump sum price worked out by the contractor for STAND BY DG SETS WORKS as listed in Schedule 'A' Part-XIII brought forward from serial page No. 47.
16Lump sum price worked out by the contractor for AC PLANT WORKS as listed in Schedule 'A' Part-XIV brought forward from serial page No. 48.
17Miscellaneous items of Works (To be quoted by Bidder) as listed in Schedule 'A' Part-XV
18INTERNAL ELECTRIFICATION WORKS
19Supply and fixing flame proof switch socket & plug combined in LM6 cable termination box in LM6,110/16 Amps, 250 volts, 2P+Earth complete all as specified.
20Supply & fixing of flameproof flood light fitting 1x45 watt highbay design to operate safety in haradzous enviroments CMRI certified recommendation for gas/vapour group of llA & lllB, zone 1 & 2 and IP-65protection with die caes aluminium housing with heat resistant toughned glass with LED light fixture drivers, connector etc , complete with all accessories prewired and including connecting up with three core flameproof FRLSH flexible copper conductor cable of suitable size complete all as specified and directed.
21M&L for flame proof weather proof Control Panel MCB DB 8 way in Cast Alluminium Alloy LM6 Construction Cat No MCDB/186. Certified by CMRI Dhanbad for Group llA & lB 01 MCB SPN 16 amps as incomer & 6 Amp SP as outgoing with common Neutral link, earth bar, including fixing to wall complete all as specifed and directed.
22M&L for flame proof weather proof Control Panel MCB DB 6 way in Cast Alluminium Alloy LM6 Construction Cat No MCDB/186. Certified by CMRI Dhanbad for Group llA & lB 01 MCB SPN 32 amps as incomer & 6/16 Amp SP as outgoing with common Neutral link, earth bar, including fixing to wall complete all as specifed and directed.
23M&L for flame proof weather proof Control Panel MCB DB 4 way in Cast Alluminium Alloy LM6 Construction Cat No MCDB/186. Certified by CMRI Dhanbad for Group llA & lB 01 MCB SPN 32 amps as incomer & 6/16 Amp SP as outgoing with common Neutral link, earth bar, including fixing to wall complete all as specifed and directed.
24Supply and fix bldg street fitting made up of pressure dai cast aluminum housing with high efficiency LEDs as a lighting source and lens embedded PC Cover Having TOP oppening separate driver compartment with IP 66 protection and impact resistance of IK07, CCT 5700 K, of wattage 25 Watt including connection with 3 core PVC insulated overall sheathed flexible cable with multi stranded copper conductor of size not less than 1.0 sq mm from celling rose to fitting terminal all as specified and directed. Make :- Havells/ Bajaj/ HPL /Philips
25Supply and fix GI pipe bracket made of GI pipe light grade 32mm dia and bend to shape 1.5 mtr long MS clamp made out of MS flat iron (02 nos) of size 32mm x 4mm with nut and bolts washer complete including drilling of holes for nut and bolts etc complete all as specified and directed.
26Supply and fixing Supply and fixing flameproof wall mounted fan 16 inches, 230V, 1440 RPM, 0.50 HP, heavy duty, explosion proof motor and spark free materials, suitable for zone I & II with gas groups IIA, IIB and IIC, blade material anti static and non sparking LM-6 Aluminium alloy, IP-65/66 including Insulation class 'F' etc connected with and including three core 1.5 sq mm , PVC insulated but unsheathed FRLSH cable with multistranded copper conductors complete all as specified and directed.
27Supply and fixing Flameproof (FLP) Heavy duty, Exhaust fan 15\\" sweep , Non sparking Aluminium Alloy, weather proof ,, motar rating 240 V, 1440RPM , 50Hz 40 watt , 1400 RPM, explosion proof motor and spark free materials, suitable for zone I & II with gas groups IIA, IIB and IIC, blade material anti static and non sparking LM-6 Aluminium alloy, IP-65/66, special designed metal blade , powder coated long lasting finish, sturdy steel bird guard with louvers and frame and connected with and including three core 1.5 sq mm, PVC insulated but unsheathed FRLSH cable with multistranded copper conductors complete all as specified and directed.
28SEWAGE DISPOSAL
29Construction of on site hume pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc., complete for 10 users all as specified and directed.
30Construction of soakage well 1.80m internal dia and 3.00m depth including brick bat filling inside and outside the chamber with ring wall, inlet pipe upto 1.80m from outer face of ring wall, earth filling etc. including excavation and earth work complete all as specified and as shown on Drgs.
31RAIN WATER HARVWSTING
32S&F PVC Pipe 150mm dia Class 'A' including all necessary fittings complete all as specified and directed.
33M&L gravel packing as in filter mediea of size 12.5 mm around PVC pipe as in rainwater harvesting recharge pit, complete all as specified.
34M&L gravel packing as in filter mediea of size 3mm to 5mm around PVC pipe as in rainwater harvesting recharge pit, complete all as specified.
35EXTERNAL ELECTRIFICATION WORKS
36Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested ) cubicle type IP-65,outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of plateform. The plateform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class'B') work duly plastered in CM 1:3 and PCC copping (1:2:4) not less than 50 mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engineer-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:- Please Enable Macros to View BoQ information
37Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested ) cubicle type IP-65,outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of plateform. The plateform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class'B') work duly plastered in CM 1:3 and PCC copping (1:2:4) not less than 50 mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engineer-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56633876
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 7.65 Crore
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Construction Of 02X25mt (Nec) Ac Igloos At Ferozepur Mil Stn (Tender Id : 2026_Mes_780243_1)
Basic Detail
Tender No 81117/E8
Bidding Type Tender
Location
City Jalandhar
State Punjab
Key Dates
Publish Date 23 Jul 2026
Submission Date 31 Aug 2026
Open Date 07 Sep 2026
Finance
Tender Value 7.65 Crore
Tender Fee 3000
EMD 7.08 Lakhs
Exemption Available
Document List
bb7ca11e-ae99-4f44-95db-0126385ff90f.html
BOQ_874218.xls
STD_Drgs.rar
TD_Drgs.rar
TenderDocuments81117.pdf
Tendernotice_1.pdf
WD_Drgs.rar

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

bb7ca11e-ae99-4f44-95db-0126385ff90f.html

xls

BOQ_874218.xls

rar

STD_Drgs.rar

rar

TD_Drgs.rar

pdf

TenderDocuments81117.pdf

pdf

Tendernotice_1.pdf

rar

WD_Drgs.rar

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders