Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56633860

Tender For Provn Of 08 X Street Lights On Route From Arjun Chowk To Flag Staff House, Provn Of 06 X 1.5 Ton All Weather Ac At Mi Room Complex , Provn Of 01 X Ac (2 Ton) Along With Stablizer Accessories And Electrical Fittings In Dog Kennel And provid

Issued by Statutory Bodies & Commissions/Committees · Anantnag, Jammu and Kashmir
Tender Value
13.07 Lakhs
Estimated cost
Bid Submission
15 Aug 2026
20 days left
EMD
26200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provn Of 08 X Street Lights On Route From Arjun Chowk To Flag Staff House, Provn Of 06 X 1.5 Ton All Weather Ac At Mi Room Complex , Provn Of 01 X Ac (2 Ton) Along With Stablizer Accessories And Electrical Fittings In Dog Kennel And providing 02 X 360 Ltrs Refrigerator & 02 X Water Cooler 80 Ltrs Capacity At Awantipur Grn Under Ge 861 Ews.

BOQ

Name of Work:- PROVN OF 08 X STREET LIGHTS ON ROUTE FROM ARJUN CHOWK TO FLAG STAFF HOUSE, PROVN OF 06 X 1.5 TON ALL WEATHER AC AT MI ROOM COMPLEX , PROVN OF 01 X AC (2 TON) ALONG WITH STABLIZER ACCESSORIES AND ELECTRICAL FITTINGS IN DOG KENNEL AND PROV 02 X 360 LTRS REFRIGERATOR & 02 X WATER COOLER 80 LTRS CAPACITY AT AWANTIPUR GRN UNDER GE 861 EWS.
Sl. No. Item Description
1Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Hard /dense soil complete all as specified and as directed by Engineer-in- charge.
2Returning filling including spreading levelling, watering and well ramming in layers not exc. 25cm in any type of soil complete all as specified and directedby Engineer-in-charge.
3Removing exavated materials (soils ) not exc 50 mtr and depositing where directed at a level not execeeding 1.5 mtr above the starting point complete all as specified and directedby Engineer-in-charge.
4Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose)
5Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
6Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 50 Sqmm 4 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
7Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 4 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
8Supply and Laying GI tubing 50mm bore Light grade with all fittings such as clamps laid in trenches or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'.
9Supply and Laying GI tubing 40mm bore Light grade with all fittings such as clamps laid in trenches or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'.
10Material & Labour for dismantling / cutting of existing road / path / hard standing cement concrete (unreinforced) in ground floors and pavings not exceedomg 15 cm thickness (below or above ground level) suitable for laying cable protection pipe 50 to 80 mm dia under the road / path / hard standing complete all as specified and directedby Engineer-in-charge. Note: Pipe of appropriate size shall be measured and paid seperately under appropirate items of Schedule'A' BoQ.
11Material and labour for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) for making good the disturbed surface of road/path/hard standing/ foundation of pole complete all as specified and as directed at site by the Engr-in-Charge.
12Material and labour for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) for coping of pole complete all as specified and as directed by Engineer-in-charge.
13Material and Labour Steel tubular poles type 410 SP-31 (9.00mtr long) complete with cast iron base plate, finial, taper plug, bolts nuts & screws complete all as specified including internal surface of steel tubular pole through out and external surface up to planting depth shall be painted with bituminous paint and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles , with and including excavation and earth work such as excavtion, returing filling ,removal and form work compete all as specified and as directed by Engineer-in-charge. Notes:- 1. The rate of Necessary earthwork , such as excavtion, returing filling ,removal and form work is included in this item . Nothing shall be paid extra on this account.2. Cement concrete work shall be measured and paid seperately in respective items of Schedule 'A' BoQ.
14Supply and fixing security / Street light bracket, 1.50 metres long, fabricated from 40 mm dia light-grade galvanised iron pipe, formed with a 30° bend, with and including flat iron clamps of size 40 mm × 6 mm, complete with suitable nuts, bolts and washers for securely fixing and bracing the bracket in position; the complete bracket and clamps duly painted with two coats of silver-coloured synthetic enamel paint over one coat of red oxide primer, including all necessary cutting, bending, drilling, fabrication, fixing and making good, complete all as specified and directed by the Engineer-in-Charge.
15Supply & Fixing LED Security street light fitting 35 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) Cable for connection from pole to street light shall be measured and paid seperately under appropriate item of Schedule 'A' BoQ.
16Supply and fixing of 3-core, 1.5 sq mm, 1100-volt grade, FRLS PVC insulated and PVC sheathed, stranded copper conductor round flexible cable, drawn through steel tubular street-light pole and street-light arm for connection from junction box to LED street-light luminaire, including making connections at both ends with suitable lugs, ferrules and all necessary accessories, complete all as specified and directed by the Engineer-in-Charge.
17Supply and fixing Cable junction box , IP- 66 , Halogen free and weather proof for out door installation , made of thermoplastic material of size 195 mm x135 mm x 90 mm, suitable for upto 16 sqmm cable entry & cable out opening , fitted with and including 01 No. MCB , SP 6 to 32 Amps , 240 Volt , 'C' Curve , 10 KA for street light complete internally pre-wired fitted with terminals,connectors etc and including neccessary fixing arrangement such as nuts, bolts, washers, MS clamps made of 20mm x 5 mm and painting etc including making connection complete all as specified and as directed by Engineer-in-charge.
18Supply and fixing Street light timer panel , outdoor type , IP - 54 protection internal wiring with FRLSH cable of suitable capacity, inbuilt short circuit protection , CPRI approved , suitable for 415V, 3 Phase, 4 wire, 50 Hz, AC supply system fabricated from CRCA sheet 3.15mm , totally enclosed, dust, weather & vermin proof, front openable, single door system lockable / openable by keys fancy locks air vent gasket for natural flow of air, the bottom of the shell contains a detacheable plate having provision for entry of adequate size with glands, confirming to IS/IEC 61439/60529 suitable to mounting on walls/floor with necerssary clamp with nut bolt washer etc including connecting up all incoming and outgoing cable with cable gland with following accessaries for three phase maximum load 12 KW, contactor 65 Amps TP. MCB 63 Amps TPN 2 Nos, digital/analog 24 hrs time switch, on/off , phase indication lights completet all as specified and as directed by Engineer-in-charge.
19Supply, installation, testing, and commissioning of 1.5 TR High Wall Split Air Conditioner comprising indoor and outdoor units, complete with cordless remote control, in-built heating and cooling functions, and digital inverter twin rotary compressor technology. The unit shall be complete with all standard accessories, refrigerant, interconnecting refrigerant piping, drain piping, electrical connections, mounting brackets, and all other necessary components for satisfactory operation, complete all as specified and as directed by the Engineer-in-Charge.
20Supply and installation of copper wound voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directedby Engineer-in-charge.
21Supply and installation of copper wound voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directedby Engineer-in-charge.
22Material and Labour Sub main wiring with two single core of size 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked including cuttting, chasing and grouting , with and including non metallic rigid PVC conduit medium quality of size 25 mm dia conforming to 3537 Part-I ISI marked including all fitting such as Tee, Elbow, bend etc drawn in and including one single core of size 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three single core 6.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked with and including non metallic rigid PVC conduit of size 25 mm ISI Marked dia shall be measured as one length.
23Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account.
24Supply and fixing MCB SP 6 to 32 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge.
25Supply and fixing MCB SPN 32 Amps 10 KA 'C' curve 240V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge.
26Supply, installation, testing, and commissioning of 2.0 TR High Wall Split Air Conditioner comprising indoor and outdoor units, complete with cordless remote control, in-built heating and cooling functions, and digital inverter twin rotary compressor technology. The unit shall be complete with all standard accessories, refrigerant, interconnecting refrigerant piping, drain piping, electrical connections, mounting brackets, and all other necessary components for satisfactory operation, complete all as specified and as directed by the Engineer-in-Charge.
27Material and labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with 4.0 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , with and including PVC casing and capping of medium grade of suitable size and run on wall / surface with all fittings (ISI Marked) with and including one single core 4.0 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. controlled by two pin earth plug and socket with and including PVC Gang Box of required size & as directed by Engineer- in- Charge including cutting, chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed by Engineer-in-Charge. Notes : (i) Two pin earth plug and socket shall be measured and paid seperately under respective items of Schedule'A' BoQ.
28Supply & Fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one single pole MCB 32 Amps , 10kA, 'C' Curve complete all as specified and directedby Engineer-in-charge. Note: The rate of one single pole MCB 32 Amps , 10kA, 'C' Curve is included in this item and nothing shall be paid extra on this account. contractor shall quote his rate after considering of this aspect.
29Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated TPN, 4 Way 415 V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCBs / MCCBs/ Isolators, conforming to IS/IEC-61439-2:2011, BS-5484 dust and vermin proof, complete all as specified and directed by Engineer-in-charge. Notes:(i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account.
30Supply and fixing of electric refrigerator, single-phase operated, having a gross storage capacity of 360 litres with 5-Star BEE Energy Rating, complete with all standard accessories, complete in all respects, as specified and directed by the Engineer-in-Charge.
31Supply and fixing of electrically operated water cooler, Fully stainless steel , single-phase, having an approximate storage capacity of 80 litres and a nominal cooling capacity of 40 litres per hour, complete with all standard accessories and necessary connections, complete in all respects, as specified and directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56633860
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13.07 Lakhs
LAST DATE 15-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 08 X Street Lights On Route From Arjun Chowk To Flag Staff House, Provn Of 06 X 1.5 Ton All Weather Ac At Mi Room Complex , Provn Of 01 X Ac (2 Ton) Along With Stablizer Accessories And Electrical Fittings In Dog Kennel And providing 02 X 360 Ltrs Refrigerator & 02 X Water Cooler 80 Ltrs Capacity At Awantipur Grn Under Ge 861 Ews.
Basic Detail
Tender No GE 861 EWS-51(T)/2026-27
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 23 Jul 2026
Submission Date 15 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 13.07 Lakhs
Tender Fee 500
EMD 26200
Exemption Not Available
Document List
b22539a4-5a25-4f43-8c0c-f01ed8c119e7.html
BOQ_874222.xls
Tender51.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

b22539a4-5a25-4f43-8c0c-f01ed8c119e7.html

xls

BOQ_874222.xls

pdf

Tender51.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender