Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56633858

Tender For Repairs To Internal Electrification Including Meters, Ceiling Fans, Geysers And External Electrification Including Fps, Dbs And Apfc At Gv C And 26Ed Under Ge (Af) Marathahalli

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
42 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
10 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs To Internal Electrification Including Meters, Ceiling Fans, Geysers And External Electrification Including Fps, Dbs And Apfc At Gv C And 26Ed Under Ge (Af) Marathahalli

BOQ

Name of Work:- REPAIRS TO INTERNAL ELECTRIFICATION INCLUDING METERS, CEILING FANS, GEYSERS AND EXTERNAL ELECTRIFICATION INCLUDING FPs, DBs AND APFC AT GV C AND 26ED UNDER GE (AF) MARATHAHALLI
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by EIC.
2Taking down carefully unserviceable sub main wiring of any size and type including making good the disturbed surfaces of walls, ceilings etc including two coats of white /colour washing/ distempering etc to match the existing complete all as directed by EIC.
3Taking down carefully unserviceable distribution boards/metal enclosures of any type and capacity including wooden board and making good the disturbed surfaces of walls, ceilings etc including two coats of white/colour washing/ distempering etc to match the existing complete all as directed by EIC.
4M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for One light point / one bell point controlled by one, one way switch.
5All asper Item No.04 above but One fan point controlled by one, one way switch.
6All asper Item No.04 above but one light point controlled by 2 way switch.
7All as per Item No.04 above but for One 3 pin, 05 /06 Amps socket outlet point on same board controlled by one , one way 05/06 Amps switch
8All as per Item No.04 above but for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
9All as per Item No.04 above but capping cassing wiring One Light/fan point controlled by one, one way switch.
10All as per Item No.04 above but capping cassing wiring for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
11M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc,including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for one 15 /16 Amps socket outlet point on independent
12All as per Item No.11 above but capping cassing wiring for One 3/5 pin, 15 /16 Amps socket outlet point on independent board with 2.5 sqmm cables.
13Supply & fixing in repair modular switch 06 Amps 1 module complete all as specified & directed
14Supply & fixing in repair modular switch2 way , 06 Amps 1 module complete all as specified & directed
15Supply & fixing in repair bell push modular type 6 Amps complete all as specified & directed.
16S & F in repair modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
17Supply & fixing in repair modular switch 16 Amps 1 module complete all as specified & directed
18S & F in repair modular socket 06/16 Amps 2/3 pin combined 2 module complete all as specified & directed.
19S & F in repair electronic fan regulator modular type, 2 module, 120W including complete all as specified and directed.
20S & F in repair switch piano flush type, 05/06 Amps single pole, one way 240 volts in replacement of old u/s complete all as specified & directed
21Supply & fixing in repair of socket outlet 3 pin, 05/06 Amps (2-in-1 Multipurpose) flush type 240 volts in replacement of old u/s complete all as specified & directed.
22Supply & fixing in repair of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts in replacement of old u/s complete all as specified & directed.
23Supply & fixing in repair switch piano flush type, 15 /16 Amps single ploe, one way 240 volts in replacement of old u/s complete all as specified & directed
24Supply & fixing in repair of ceiling rose surface three terminals in replacement of old u/s complete all as specified & directed.
25Supply & fixing in repair bell push flush type 5 Amps in replacement of old u/s complete all as specified & directed.
26S & F in repair Door bell AC, 230 volts, single pole in replacement of old u/s bell/ buzzer complete.
27Supply & fixing in repair Switch socket combination 2-in-1, 3 pin, 5 and 15 Amp flush type in replacement of old u/s complete.
28Supply & fixing in repair Switch socket combination 2-in-1, 3 pin, 5 Amp flush type in replacement of old u/s complete.
29S & F in repair electronic fan regulator stepped, socket type 400W including removing the switch board panel and making the provision for fixing the electronic type regulator and refixing the same complete all as specified and directed.
30S & F in repair MCB DB SPN 4Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
31S & F in repair MCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
32S & F in repair MCB DB SPN 12Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
33S & F in repair MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed.
34S & F in repair MCCB DB Vertical TPN 8 Way 'A' Frame,Including MCCB TPN 125 Amp Beaking capacity 25Ka -01 nos, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. Make -Havells or equivalent
35M & L for sub main wiring complete with two runs of 2.5 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 1.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
36M & L for sub main wiring complete with three runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
37M & L for sub main wiring complete with two runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
38Material and labour for Cutting, chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, chills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc; and making good, cutting not exc 10 cm girth complete all as specified and directed.
39S & F in repair MCB SPN 40 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells or equivalent
40S & F in repair MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells or equivalent
41S & F in repair MCB TPN 63 Amps incl making connections all as specified and directed. Make -Havells or equivalent
42S & F in repair MCB TP 63 Amps incl making connections all as specified and directed. Make -Havells or equivalent. Make -Havells or equivalent
43S&F in repair LED PC batten light fitting of 2 feet 10 watt, with energy efficient LED and integrated electronic driver of 10W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
44S&F in repair LED lights fitting 1x 18W, 220V box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
45S&F in repair S&F in repair LED PC batten light fitting of 4 feet 20 watt, with energy efficient LED and integrated electronic driver of 20W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
46Supply & Fix in repair linear LED T8 tubular lamp 18W with extruded aluminium/PC body and PC diffuser complete with inbuilt driver incl making necessary connections in the existing fittings to suit the LED tube complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells)
47S & F in repair LED fitting of 6 watts - Square surface mounted LED flat panel down light, PDC aluminum housing and PMMA diffuser makes it a robust Luminaire alongwith 6W LED lamp complete all as specified. (Make: Bajaj /CG/Philips/Havells
48Supply and fixing new LED lamp 9 watt complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
49Supply and fixing in repair LED lamp 5 watt complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
50S&F in repair energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser complete with and incl 10W LED all as specified and directed. (Make : Bajaj /CG/Philips/Havells
51Taking down ceiling fan/Exhaust fan, sealing the cable ends dismantling the fan blade kept in safe costody complete all as specified. Note: (a) Servicing and Spares will be measured and paid seperately .
52M & L for painting of ceiling fan/ exhaust fan complete, at site with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust all as specified.
53Hanging only ceiling fan/exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost.
54Labour for servicing the ceiling / exhaust fan of any make including greasing /oiling /repairs and replacing the spares such as cater pin unserviceable / rusted bolts, split pins, rubber wheel, bearing, washers, bush all as specified and directed .
55Supply only GM bush of ISI marked suitable for ceiling fan of size 1200 / 1400mm sweep.
56Supply only ball bearing suitable for ceiling fan of 1200 /1400mm sweep. Make : SKF, bearing No 6202 or equivalent in NBC.
57Replacement of old unserviceable capacitors 2.5 MFD of the fan in position as directed by Engr - in - Charge
58Replacement of old unserviceable capacitors 4.0 MFD of the fan in position as directed by Engr - in - Charge
59M & L for dismantling the defective exhaust fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material, \\"O\\" rings and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed.
60M & L for dismantling the defective Ceiling fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight,warnishing , including replacement of all insulation material, and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed.
61M&L for straight through joints (epoxy) heat shrinkable type for UG cable including joint kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor upto 16 Sqmm to 10 sqmm 4 core cable complete all as specified and directed. (Make : 3M /Densons).
62All as per ser item no. 61 here-in-before but of size upto 25 to 50 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
63All as per ser item no. 61 here-in-before but of size upto 70 to 150 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
64All as per ser item no. 61 here-in-before but of size upto 185 to 300 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
65All as per ser item no. 61 here-in-before but of size upto 400 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons). Note for ser item nos 61 to 65 : Excavation and earth work shall be measured and paid seperately.
66M & L for Fault locating of LT UG cables by using measuring instruments and rectification of the same by using epoxy cable joints of suitable size of cables and testing the phase contuinity of the cable complete all as specified and directed. Note : Cable joint kit and Excavation/earth work shall be measured and paid seperately.
67Taking down unsv 250 Amps MCCB and Supply & Fix MCCB TPN 415 Volts 250 Amps rating with breaking capacity of 35 kA with adjustable thermal & magnetic release complete with making all connections as per site requirement as specified and directed. (Make : Havells / L&T/ Legrand)
68All as per ser item no.67 here-in-before but MCCB TPN 415 Volts 100 Amps, 25 kA complete with making all connections as specified and directed. (Make : Havells / L&T/ Legrand)
69All as per ser item no.67 here-in-before but MCCB TPN 415 Volts 160 Amps, 25 kA complete with making all connections as specified and directed. (Make : Havells / L&T/ Legrand)
70All as per ser item no.67 here-in-before but MCCB TPN 415 Volts 63 Amps, 25 kA complete with making all connections as specified and directed. (Make : Havells / L&T/ Legrand)
71Supply and fixing four pole changeover switch disconector with advance neutral 415 volt 50 Hz 100/125 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 including dismantling old one complete all as directed. Make - Havells / L & T /Legrand
72Supply and fixing in repair for swich disconnector fuse unit in sheet steel enclosure TPN current rating 200 Amp with HRC Fuse including disconnecting and taking out unserviceable one complete all as directed. Make - L&T / Havells / HPL .
73Supply and erecting steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-22 (8.5 meter long) complete, Including disconnecting and taking out old damage PCC pole all as directed. (Note Excavation & Earth work and PCC foundation/base shall be measured and paid separately under relevant items of this BoQ)
74M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
75Dismantling and taking out servicable cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed.
76M & L for painting the surface of post top poles of size 50mm dia and 3 mtr length by applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-charge.
77M & L for Painting of steel pole/PCC pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia yellow circle & marking six black & four yellow bends width 15 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed.
78Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete.
79Excavating in trenches exceeding 1.5 m wide and not exceeding 3 m depth and not less than 1.5 m in depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed .
80Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick complete all as specified.
81Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
82Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
83Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
84M & L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
85All as per Srl item No 84 here in above but GI pipe of size 80 bore
86Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site all as directed by Engr-in-charge.
87Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 300 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Make: Havells/ Polycab/Grandlay)
88All as per Srl item No 87 here in above but size of cable 120 Sqmm 3.5 core
89All as per Srl item No 87 here in above but size of cable 16 Sqmm 4 core
90All as per Srl item No 87 here in above but size of cable 10 Sqmm 4 core
91All as per Srl item No 87 here in above but size of cable 25 Sqmm 4 core
92All as per Srl item No 87 here in above but size of cable 95 Sqmm 3.5 core
93All as per Srl item No 87 here in above but size of cable 35 Sqmm 3.5 core
94All as per Srl item No 87 here in above but size of cable 50 Sqmm 3.5 core
95Laying only cable any sizes obtained from item No 86 of Sch ‘A’ with all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed
96S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1 No. MCB 20 Amp capacity complete all as specified and as directed
97Supply and fixing in replacement of 1100 Volts grade heavy duty cable 10 Sqmm 2 core with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulated hanger not more than 1 mtr a part including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed by Engr-in-Charge. Make : Finolex/Plaza/Kalinga/Paragon :-
98Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure.
99M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.
100Material & labour for fixing of Earth continuity conductor GI strip of size 25X 4 mm with nut bolts at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, strip fixed on with epoxy insulatorof suitable size all as specified and directed by Engineer-in-Charge.
101Taking down the u/s post top lantern from position by disconnecting the electrical connection carefully and replacement with New generation, post-top of 40 Watts, 240V, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including making all necessary wiring, provn of suitable fitments and connecting upto control box complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
102Supply and fix in repair GLOBE LED post top in spherical shape polycarbonate opal and clear di user with IP 65/66 protection of cap 25 watt complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
103S&F PVC Junction box of size 255X200X100mm inside dimension fixed on pole by means of mild steel clamps with hinged door, bolt and nuts, provn for cable entry for incoming and outgoing including MCB 2.5 amps-1 No and 4 way connector-1nos neccessary connection duly fixed with clamps on pole and including cable glands threaded type IP55/IP65 made of polymide with lock nut complete all as specified. Make : Sintex GSJB2520 or equivalent.
104M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed.
105M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of the LT poles including form work complete all as specified
106Supply and fixing of Endura Citylite Platinum, 45 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection in replacement of old UNSV 70W HPSV light fittings complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
107Supply and fixing of Endura Cityliner Neo, 60 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection in replacement of old UNSV 150W HPSV light fittings complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
108Supply and fixing of Endura Cityliner Neo, 70 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection in replacement of old UNSV 150W HPSV light fittings complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
109Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
110Taking out the u/s Street light fitting driver and S&F LED Driver unit suitable for 30 to 45 watt capaity complete all as specified and directed Make - Bajaj /CG/Philips/Havells
111Maintenance for APFC panel (out door type) at GV Camp :- (i) APFC panel (outdoor type) 240 (2 x 10, 1 x 20, 8 x 25) KVAR - 01 No capacitors, internal wiring,inrush current limiting coil, auxilary contactor, indicating lamps, auto-manual selector switch, MCCB ,axial flow fan and replace the unserviceable parts. The following checking will be carried out to ensure smooth and effective operation all the time all as specified and directed. (a) Checking of the control panel,power supply, fuses ,circuits etc and tighten to any loose contact (b) Checking of the helthiness of capacitors,contactors and APFC relays. (c) Cleaning of the panel by using blower without any distrubance/damages. (Note:- Spares will be measure and paid seperately )
112Supply and fixing 10/12.5 KVAR Capacitor (heavy duty) 440 volts with inrush current limiting coil complete all as specified and directed.
113Supply and fixing 20 KVAR Capacitor (heavy duty) 440 volts with inrush current limiting coil complete all as specified and directed.
114Supply and fixing 25 KVAR Capacitor (heavy duty) 440 volts with inrush current limiting coil complete all as specified and directed.
115Supply and fixing Capaitor duty contactor 10/12.5 KVAR capacity complete all as specified and directed.
116Supply and fixing Capaitor duty contactor 20 KVAR capacity complete all as specified and directed.
117Supply and fixing Capaitor duty contactor 25 KVAR capacity complete all as specified and directed.
118Add on Auxiliary contact Block 4 NO
119Maintenance of storage type electric water heaters(Geyser) of storage capacity 25 ltrs comprising of the following tasks and all as per specified and directed by Engr-in-Charge.(a) Inspection taking down, opening (dismantling),descaling, brushing cleaning of storage tank and painting internally with one coat of proprietary bituminous compositions not liable to impart taste or or odour or otherwise contaminate the water.(b) Examine water tightness of storage tank after cleaning.(c) Carry out operation of all stop cocks,pressure reducing valves etc to ensure free movement of the working parts.(d) Replacement washers and glands of all taps and ball valves to ensure water tightness.(e) Visual examination of fusible plug to (f) Descaling of the immersion type heating element and cleaning with diluted hydrochloric acid or \\"clear pedette\\" solution and testing before refitting.(g) Replacement/repair of neon lamp/indicator lamp.(h) Replacement of the rubber/PVC gaskets to ensure water tightness..Note : (i) Attending complaint during the currency contract period on phone call and rectification with in 24 Hrs.(ii) The spares will be measured and paid seperately.
120All as per Item No-119 above, but of 50 ltrs storage capacity.
121Supply only new heating element suitable to existing model and make 2 KW Dual clip type/tri angle type and round type with rubber gasket suitable for geysers up to 25/50 Ltr capacity . Make: Theeta /Elteck or equivalent
122Supply only new heating element suitable to existing model and make 1.5 KW Dual clip type/tri angle type and round type with rubber gasket suitable for geysers up to 25/50 Ltr capacity . Make: Theeta /Elteck or equivalent
123Supply only thermostat clip type (Range 30 C to 80 C and acting at 70 C) for geysers up to 50 Lts. range 30 C to 80 C and acting at 70 C all as specified . Make: Elcon or eq
124Supply only PVC connections up to 600 mm in length suitable to connect GI pipe 15 mm dia to hot water outlet of geyser.Make: Kohinoor or eqivalent
125Supply only PVC connections up to 650 mm in length suitable to connect GI pipe 15 mm dia to cold water inlet of geyser.Make: Kohinoor or eqivalent
126Supply only pressure release valves suitable for geyser up to 50 ltrs capacity
127Supply only indicating lamps green / red suitable for geysers up to 50 Ltrs
128Supply only HRFR PVC insulated copper flexible cable 3 core 2.5 Sqmm and PVC sheathed 1100 volts grade
129Taking down unserviceable plug top and supply and fixing plug top 3 pin 15 amps 230 volts complete all as specified and directed.
130M&L for arresting the leakage in inner tank of any size/make of geyser complete with brazing work and leak test, servicing etc
131S& F Non return valve of size 1/2\\"
132Material and labour for painting of storage type electric water heaters(Geyser) of storage capacity 25/50 ltrs painting with one coat of synthetic enamel paint ( as per exsisting colour) all as per specified and directed by Engr-in-Charge.
133Supply and fixing in replacement digital type Ampere meter range 0 – 400/300/200 Amps, with built in selector switch including CTs with proper ratio, square type, flush mounted of size 96 mm x 96 mm including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge.
134Supply and fixing in replacement digital type Volt meter with built in selector switch, range 0 – 500 volts, square type, flush mounted of size 96 mm x 96 mm including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge.
135S&F Celing Fan complete with blades , down rods ,elcetrinic regulator and acessories , 230 volts, 1200 mm sweep , min air delevery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed.
136Material and labour for Cleaning and preparation of old painted surface of LT panel board complete and painting with one coat of synthetic enamel paint (exsisting colour) on surfaces of panel board all as specified and directed by Engineer-in-Charge.
137Supply and fix exhaust fan, steel body AC single Phase. 230V of size 250 / 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
138Supply and fixing wall fan of single phase 230/240V of size 400 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed .
139Supply and fixing in repairs 36W LED Fitting, 2 x 2 recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified including taking down old unserviceable fittings.Make : Bajaj /CG/Philips/Havells
140Supply and fixing of Nature switch (using infrared sensor technology )based automatic street light control panel .This panel should be suitable enough to 3 phase load of 5 KW .Nature switch operation should be based on natural light lux level .Required illuminance level for switching ON is < 60 Lux & for switching off > 10 lux .The sensor alongwith suitable power contactors and incoming outgoing MCB should be enclosed in a pole /wall mounted rust proof ,electric shock ,termite proof and FR grade SMC Enclosure conforming to IP 54 ,The circuit should also have aprovision for manual operation (i.e sensor bypass option ) .The nature switch must have 3 phase load of 5 KW (swadeep 02EC-5kW3p with 3 nos incoming outgoing MCBs of 16 -20 Amps & 3 nos contactors (single pole /2/ pole/3 pole ) of 16-20 Amps & circuit wiring (copper )10 mm2 complete all as specified and as directecd :Make : Swadeep
141Taking down outdoor Feeder panel of any size with MCCB / changeover type complete all as specified and directed by Engr-in-Charge.
142Supply, installation, testing and commissioning of outdoor type cubicle panel board suitable for 3 phase 4 wire 415 V, 50 Hz and tested at CPRI for 415 volts factory fabricated in an approved factory having modern fabrication process powder coating in approved shared having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS : 8623/93 comprising. The outer shell shall be made out of 3 mm thick CRCA sheet and MS angle section 40x40x6 mm base frame factory fabricated with front openable, double door system lockable/ open able. The bottom of the outer shell contains a detachable plate having size with glands. The outer shell shall be mounted on stand having zine coating not less than 80 microns. Provision of threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP - 54. Inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, TPN alluminum bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleave. All control wires shall be with 2.5 sqmm multi strand copper conductor and shall be propely bunched, tied, ferruled for proper identification and crimped with adequate size of lugs all as specified and directed by Engr in charge.INCOMING-(a) MCCB 200 Amps 35 KA - 02 Nos .(b) Intelligent AC digital display three phase LCD ammeter 0 to 630A and voltmeter 0 to 500V with CT.(c) Indication lamp RYB/RRR-set of 03 -01 No.OUTGOING-(a) MCCB 4 pole 125 Amps 25 KA 415 Volt - 4 Nos.(b) MCCB 4 pole 63 Amps 25 KA 415 Volt - 3 Nos.(c) MCCB 4 pole 32 Amps 16 KA 415 Volt - 2 Nos.(d) Changeover of capacity 4 Pole 200 Amps - 1 No.(e) Spare pocket for provisioning of MCCB
143S & F in repair LED spot light 5 watt Innova Neo Surface mounted spotlight in matt finish for premium aesthetics complete all as directed
144Supply and fix electric water heater,storage type ABS body with SS inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Starrated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56633858
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs To Internal Electrification Including Meters, Ceiling Fans, Geysers And External Electrification Including Fps, Dbs And Apfc At Gv C And 26Ed Under Ge (Af) Marathahalli
Basic Detail
Tender No 8852/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 23 Jul 2026
Submission Date 12 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 42 Lakhs
Tender Fee 500
EMD 84000
Exemption Available
Document List
9ef15a2b-1fbb-4973-8459-af2c3b3109bc.html
BOQ_874044.xls
TENDER8852.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

9ef15a2b-1fbb-4973-8459-af2c3b3109bc.html

xls

BOQ_874044.xls

pdf

TENDER8852.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender