Tender For Provn Of Tst Bathing Point With Covered Shed At 261 Transit C And Installation Of Reverse Osmosis (Ro) Plant 500 Ltrs Per Hrs At Hq 5 Sect annual repair Under Age (I) Bhalra (Nit No. 40 Of 2026-27)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Aug 2026
14 days left
EMD
15172
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagrota → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Tst Bathing Point With Covered Shed At 261 Transit C And Installation Of Reverse Osmosis (Ro) Plant 500 Ltrs Per Hrs At Hq 5 Sect annual repair Under Age (I) Bhalra (Nit No. 40 Of 2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in post holes (or similar holes) each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth aroud in layers not exceeding 25 cm with soft/loose soil all as specified and directed by Engr-in-charge. |
| 2 | M & L for hardcore of guage exc 63 mm but n.exc 100 mm deposited spread and levelled in layers n.exc 15 cm thick watered and rolled/rammed to a true surface with broken bricks all as specified and directed by Engr-in-charge. |
| 3 | M & L for cement concrete in foundation filling, subbase and mass concrete type C2 1:3:6 (40 mm graded aggregate) all as specified and directed by Engr-in-charge. |
| 4 | M & L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6 m mean radius in cement mortar 1:4 all as specified and directed by Engr-in-charge. |
| 5 | M&L for Rendering 15 mm thick cement plaster in cement mortar (1:4) on other than fair faces of brick work and surfaces to be finished even and smooth without using extra cement all as specified.(incl all necessary scaffolding, lifting arrangement) all as specified and directed by Engr-in-charge. |
| 6 | M&L two coats of cement based paint on newly plastered surface including preparation all as specified and directed by Engr-in-charge. |
| 7 | S&F Pre -painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/ cladding to wall, fixed with self tapping screwsall as specified and directed by Engr-in-charge. |
| 8 | S&F for structural steel works of Fe 410W (Gde E 250) quality A, as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. including painted one shop coat of zinc chromate/red oxide primer paint (including preparation of surface) before fabrication all as specified and directed by Engr-in-charge. |
| 9 | Painting to steel surfaces of any description over 10 cm in width or girth not otherwise described for two coat of synthetic enamel paint over a coat of red oxide, zine chrome all as specified and directed by Engr-in-charge. |
| 10 | M&L for PCC 1:2:4 type B1 using (20 mm graded aggregate) as in blocks for hold fasts, benching, coping apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed by Engr-in-charge. Note : From work required for these item included in the unit rate of this item. |
| 11 | M&L 75 mm thick PCC type C2 1:3:6 (40mm graded aggregate) as in Plinth protection filled with mastic filling and 10 mm wide joints between the walls and plinth protection shall be filled with mastic filling all as specified and directed by Engr-in-charge. |
| 12 | M&L for 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded aggregate) for sub base in flooring all as specified and directed by Engr-in-charge. |
| 13 | M&L for 25 mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate) for subbase flooring all as specified and directed by Engr-in-charge. |
| 14 | M & L for Non-skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,in floor etc, set and jointed with neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed bed for laying floor finish in CM 1:4 all as specified and directed by Engr-in-charge. |
| 15 | M & L Coloured Glazed ceramic tiles 350 x 450 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick plastering on wall surface to receive dado tiles in CM1:4 all as specified and directed by Engr-in-charge. |
| 16 | S&F 10000 ltrs capacity rotational moulded polythelene water storage tanks in four layer (cylindrical or vertical with closed top) hoisted and fixed in position including all fittings all as specified in SSR Part I complete all as specified and as directed by the Engineer-in-Charge. |
| 17 | S&F 600 X 450 MM bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed by Engr-in-charge. |
| 18 | M&L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed by Engr-in-charge. |
| 19 | S&F galvanised medium grade steel tubing 20mm bore with all fittings fixed with walls all as specified and directed by Engr-in-charge. |
| 20 | S&F galvanised medium grade steel tubing 15mm bore with all fittings fixed with walls and inside wall and floor all as specified and directed by Engr-in-charge. |
| 21 | S & F 15 mm bore bib taps, fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule all as specified and directed by Engr-in-charge. (Make:-CERA). |
| 22 | S & F 15 mm bore stop valves/angle valve, CP Fancy type screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union all as specified and directed by Engr-in-charge. |
| 23 | S & F 20 mm bore stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union all as specified and directed by Engr-in-charge. |
| 24 | M&L for point wiring with and incl 1.5 sqmm (nominal area) PVC insulated multistranded copper conductor FRLS in PVC caping casing with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal ,One light point/fan point controlled by one way switch all as specified and directed . Make of cable for wiring - Havells/Polycab/Anchor. |
| 25 | All as per the description of serial item No 1 here in before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed. |
| 26 | All as per the description of serial item No 1 here in before but for one 3 pin socket outlet 15 Amp independent board with cable of size 2.5 Sqmm with 1.5 sqmm copper conductor in green colour for earth continuity conductor, complete all as specified and as directed. |
| 27 | S&F for switch piano flush type 5/6 Amp single pole one way, all as specified and directed by Engr-in-charge. |
| 28 | Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings |
| 29 | M&L Ceiling rose surface bakelit 65x50mm three terminals complete and making necessary connections all as specified and directed by Engr-in-charge. |
| 30 | S&F MCB DB 4- Way, single door, 240 volts for Sheet Steel, Phosphatised, Powder Painted MCB DBs with Bus Bar,Neutral Link, Earth Bar and Din Rail (In accordance with IS 13032, IS 8623, IEC/BSEN 60439-3) and all specified and directed by Engr-in-charge. |
| 31 | S&F MCB SP 6-32 Amps 'B' series 240V 50Hz 10 KA suitable for lighting and other domestic loads complete including taking down all as specified and directed by Engr-in-charge. |
| 32 | Supply & fixing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminiuum solid conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one Twin core 10 sqmm solid conductor all as specified and directed by Engr-in-Charge. |
| 33 | S&F energy saving 10 Watt LED IP 65 Bulk head luminaries, complete with all accessories, internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size 230V,50 HZ all as specified and directed. |
| 34 | Supply and fx Socket outlet 2 in 1, 3 pin, 6A complete al as specified and directed |
| 35 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm |
| 36 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning SPN 32 AMP |
| 37 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 38 | Supply, Installation, Testing & Commissioning of 500 LPH RO Plant with UV treatment complete with centifugal type Feed Pump of capacity not less than 4000 ltr/hr, of Multi Grade Filter, Activated Carbon Filter, Micron Cartridge Filter, High Pressure Pump vertical centrifugal type with multistage, RO Membrane Housing, RO Membranes, Dosing System, Control Panel, Interconnecting Piping, Valves, Fittings, Electrical Works and panel for operation of the system as per manufacturer design and recommendation for complete operation . |
| 39 | M&L Earthing complete with galvanised steel earth plate electrode, 600mmx 600mm x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including taking out old UNSV earthing and all as specified and directed. |
| 40 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, taking down/ laying of cables/ pipes or for shafts, wells, cesspits, manholes, pier holes, etc. and not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 41 | Returning, filling in, including spreading, levelling, watering and well ramming soft/ loose soil in layers not exceeding 25 cm complete all as specified and directed. |
| 42 | Removing excavated material (spoil) not exceeding 50m and depositing where directed at a level n. exc. 1.50 m above the starting point complete all as specified and directed. |
| 43 | Supply and laying dry river sand laid in trenches as cable cushioning 80mm below and 150mm above the cable and punned to 180mm and covering all as directed.Note: Punned qty will be measured and paid. |
| 44 | S & L brick covering with width equal to length of brick as the mechanical protction to cable with well burned sub class 'B' laid in trenches flat complete all as specified and directed. |
| 45 | Supply and laying LT XLPE insulated, armoured electric power cable (heavy duty), aluminium standard conductor, 1100 volts grade, cross sec area for the following sizes with galvanised steel strip or wire complete including removal of u/s cable all as specified and as directed. (Note:- Excavation, sand coushioning and bricks protections shall be measured and paid seperately under relevent items.)(a) 16 sqmm 4 core |
| 46 | S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all aspecified in SSR Part I of size 1000 ltrs alongwith arrangement of water tap. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender