Tender For Repair/ Maintenance Of Extrnal Electric Supply System Including Street / Security Light, Replacement Of Faulty Underground Cable With Connected Items At Od Shakurbasti And Hirankudna Under Ge (North).Delhi Cantt10
Tender Overview
Project Description
Tender for Repair/ Maintenance Of Extrnal Electric Supply System Including Street / Security Light, Replacement Of Faulty Underground Cable With Connected Items At Od Shakurbasti And Hirankudna Under Ge (North).Delhi Cantt10
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Jul-2026 | amendment of category | Other | 13-Aug-2026 |
| 2 | 13-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for electric cable complete in soft soil complete |
| 2 | Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point |
| 3 | Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete |
| 4 | Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete |
| 5 | M&L for sand cushioning for protection of cable with screen wash river sand complete |
| 6 | Checking & locating of fault in underground HT/LT cable of any size by cable fault locator machine complete all as directed |
| 7 | M&L (in replacement) for GI tubing light grade with all necessary fittings laid in trenches/under road crossing/under floor including suitable mild steel FI clamps of required size complete for following sizes :- |
| 8 | 40 mm bore |
| 9 | 50 mm bore |
| 10 | 80 mm bore |
| 11 | Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size Note :- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately) :- |
| 12 | 10 Sqmm 2 core |
| 13 | 16 Sqmm 4 core |
| 14 | 25 Sqmm 3.5 core |
| 15 | 35 Sqmm 3.5 core |
| 16 | 50 sqmm 3.5 core |
| 17 | 70 sqmm 3.5 core |
| 18 | 95 sqmm 3.5 core |
| 19 | 120 sqmm 3.5 core |
| 20 | 185 sqmm 3.5 core |
| 21 | 400 sqmm 3.5 core |
| 22 | Making hole below the road by drilling machine or hand drill without damaging road for inserting pipe upto 80 mm dia complete all as specified and directed Note: GI pipe shall be measured & paid separately) |
| 23 | Dismantling & taking out defective LT PVC/ XLPE cable from trenches including excavation and earth work, cutting and removing defective parts and supply and fixing straight through joint heat shrink kit complete including jointing material and making connection of LT cables for the following sizes :- |
| 24 | 25 sqmm 3.5 core to 50 sqmm, 3.5 core |
| 25 | 70 sqmm 3.5 core to 120 sqmm, 3.5 core |
| 26 | 150 sqmm 3.5 core to 400 sqmm 3.5 core |
| 27 | S&F in repair of 1100 volt grade, heavy duty cable PVC insulated aluminium conductor, unarmoured, multistranded, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended complete all as directed |
| 28 | 16 Sqmm, twin core |
| 29 | 10 Sqmm, twin core |
| 30 | Checking all incoming & outgoing connections and Mechanism, cleaning, servicing, overhauling, testing it for proper tripping system complete of 11 KV VCB of Make Crompton Greaves/AREVA/Siemens, installed at sub-station bldg, inspecting, servicing and testing all the connections of control wiring availability of proper DC supply and AC supply, cleaning of contacts, & terminals, using the blower for dusting, servicing of gears, including replacement of faulty control fuses, faulty wiring & faulty indication lamp, checking & closing of tripping system, taking out relay (over current relay and earth fault relay) from the 11 KV VCB and calibrating the relay and proper setting of relay and refixing back in existing position & testing for proper tripping/functioning system complete all as specified & directed Note : (i) Necessary certificate for calibration of relay with setting detail shall be submitted by the contractor. (ii) Spare parts will be measured and paid separately] |
| 31 | S&F in repair Charging Motor assembly set in existing VCB panel of existing make incl all connections & fixing arrangement and testing complete all as directed |
| 32 | S&F in repair Spring charging gear assembly (big size) for VCB upto 630 Amp as per existing make of VCB complete all as directed |
| 33 | S&F in repair Spring charging gear assembly (small size) for VCB upto 630 Amp as per existing make of VCB complete all as directed |
| 34 | S&F in repair power pack unit suitable for 220 volts AC input & 110 volts DC output complete with 12 volts, 7 AH sealed lead acid batteries and suitable voltmeter etc suitable for operation of HT Panel complete all as specified and directed |
| 35 | S&F in repair Tripping coil assembly 24 V DC for VCB 11 KV as per existing make of VCB complete all as directed |
| 36 | S&F in repair Closing coil assembly 24 V DC for VCB 11 KV as per existing make complete all as directed |
| 37 | S&F in repair TNC switch (Trip Neutral Close), with 2 NO + 2 NC suitable LT/HT Panel any type/size as per existing complete all as directed (Make- As per sample of make Vaishno/Kaycee/AE/Siemens/Schneider/Rishabh) |
| 38 | S&F in repair heater, 230 Volt, as per existing wattage suitable for 11 KV HT VCB panel including electric connection complete all as specified & directed (Make - As per sample) |
| 39 | Disconnection of all electric connection & taking out old/defective Current Transformer (CT) from 11 KV VCB panel and Supply, fixing, installation & testing of Current transformer, indoor, single phase resin cast CTs of 100-50/5+5 amps ratio, Class 5P-10 with suitable VA burden and accuracy suitable for protection & metering incl making suitable arrangement for fixing in existing VCB panel and connection incl disconnection & taking out old/faulty current transformers (CTs) from 11 KV VCB panel complete all as specified & directed (Make-ABB/Crompton/Schneider/Siemens/Pactil/AE)(i) All the instruments and T&P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates.(ii) The all above checking, inspection, installation & testing work shall be performed by HT expert/ engineer. |
| 40 | M&L for on line Dehydration of HV/ EHV grade transformer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 50 to 60 KV breaking capacity by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as directedNote - (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor.(ii) Oil required for topping up the transformer will be measured & paid separately. |
| 41 | M&L (in replacement) of Silica Gel (Blue colour) in breather of transformer after cleaning of breather. |
| 42 | M&L (in replacement) of breather of transformer of any make/capacity upto 630 KVA with exising size |
| 43 | Supply & filling new transformer oil of having dielectric strenght 60 KV to top up level complete all as specified and directed |
| 44 | M&L (in repair) cable jointing kit for 11 KV cable for end termination cold shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size:- |
| 45 | Size 70 sqmm to 185 sqmm, Indoor type |
| 46 | Size 70 sqmm to 185 sqmm, outdoor type |
| 47 | M&L (in repair) cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified & directed for size 70 sqmm to 185 sqmm |
| 48 | Supply & laying in trenches/through pipes/ducts or on poles XLPE armoured cable of following sizes with aluminum conductor, 11 KV `E’ complete all as specified & directed of follwing sizes Note :-Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately) :- |
| 49 | 95 Sqmm 3 core |
| 50 | 120 Sqmm 3 core |
| 51 | M&L for chequered plate 5/6mm thick of required size for cable duct cover as required at site incl cutting & welding including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed |
| 52 | M&L for painting of steel tubular poles 9 mtr to 11 mtr length with applying two coats of aluminium paint including cross arms and clamps except embedded portion of pole in ground and concrete after removing old painted surfaces by scraping of poles complete and two coat for making colour band/strip 30 CM with synthetic enamel paint of approved/yellow & black colour up to 1.2 mtr from coping level including numbering of poles complete all as directed |
| 53 | M&L for spray painting of old/existing LT/HT panel/feeder piller box any size/type with powder coated paint withsmoke grey paint in outer/inner side of complete panel after cleaning and preparing surface complete all as specified & directed |
| 54 | M&L for replacement of lock assembly with key of old/ existing LT panel board any type/size complete all as directed |
| 55 | Servicing & overhauling of Air Circuit Breaker (ACB) of any capacity by taking out from existing LT panel, cleaning all parts internally and externally, checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contact, floating contacts, servicing of motor & charging system incl replacement of faulty parts/spares and re-fixing it on its original position and testing complete all as directed Note:- Spare parts will be measured and paid separately under respective item) |
| 56 | Supply only following item/spares for Air Circuit Breaker (ACB) :- |
| 57 | Closing release of air circuit breaker |
| 58 | Shunt release of air circuit breaker |
| 59 | Under voltage release with time relay |
| 60 | S&F in repair 3 pole Power Contactor, MNX type of rating 32/40 amp AC3, closing coil 220 volt with auxiliary block (1 NO + 1 NC ) including electric connection in existing panel complete (Make- Hager/L&T /Siemens/Havell/Schneider) |
| 61 | M&L (in replacement) danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size for LT/HT 20 x 15 cm size complete all as directed |
| 62 | S&F (in replacement) following items in the existing panel / location and connection with using aluminum lugs incl making necessary alteration in panel/door as required for proper fixing & connection complete all as specified and directed :- |
| 63 | MCB 4 pole 63 amps, 10 KA breaking capacity, B'' Series, 415 Volt |
| 64 | MCB 4 pole 100 amps, 10 KA breaking capacity, B'' Series, 415 Volt |
| 65 | MCCB 4 Pole 630 amps, 50KA breaking capacity, 415 Volt |
| 66 | MCCB 4 Pole 400 amps, 50 KA breaking capacity, 415 Volt |
| 67 | MCCB 4 Pole 200 amps, 25 KA breaking capacity, 415 Volt |
| 68 | MCCB 4 Pole 250 amps, 35 KA breaking capacity, 415 Volt |
| 69 | Volt meter (0 to 500 volts) digital type, three phase of size 96mm x 96mm |
| 70 | Amp meter (0 to 300 amps) digital type, three phase of size 96mm x 96mm with suitable CTs |
| 71 | Indicator lamp, LED type |
| 72 | Multifunction Meter, digital type, three phase, size 80mm x 80mm, accuracy class 1.0 for monitoring of various electric parameters such as voltage, current, wattage, frequency, power factor etc. (Make : Schneider model No EM 6436H or equivalent in L&T/Siemens)(i) MCCB should be properly fited in existing compartment and operating handle of MCCB should be proper in opening existing cover/door of compartment of LT panel board.(ii) Make of MCCB/MCB/Contactor - Schneider/ABB/L&T/Legrand) |
| 73 | S&F steel tubular electric pole, swaged, type 410 SP-31 (9 metre long) complete with CI base plate, bolts, nuts & screws incl 06 Nos hole on top edge for holding of D-clamp & insulators complete all as specified including the following:-(a) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres.(b) M&L for Providing PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1500 mm (planting depth) for concrete encasing the pole upto GL © M&L for Providing PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia (d) M&L for painting of pole externally with one coats of black bituminous paint (upto planting depth) and above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands/strip 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above coping level |
| 74 | Dismantling and taking out unsv / damaged PCC pole any size/type complete |
| 75 | Dismantling & taking down defective stay asembly and S&F stay assembly compring of 7/10 SWG galvanised stay stranded wire of reqd length fixed to pole with and including flat iron clamp, bolts, nuts and washers, galvanised 14mm dia, 400mm long stay bow with 16mm dia 180 cms, long stay rod with threded ends, GI nut & washers GI stay plate 230 x 230 x 6mm thick plate 2 Nos thimble, MS clamp made out of 50 x 6mm flat iron loop insulator 90mm x 140mm dia, hole 25mm porcelain complete all as specified and shown in electrical plate No 1 of SSR Part I . Please Enable Macros to View BoQ information |
| 76 | Dismantling & taking down defective stay asembly and S&F stay assembly compring of 7/10 SWG galvanised stay stranded wire of reqd length fixed to pole with and including flat iron clamp, bolts, nuts and washers, galvanised 14mm dia, 400mm long stay bow with 16mm dia 180 cms, long stay rod with threded ends, GI nut & washers GI stay plate 230 x 230 x 6mm thick plate 2 Nos thimble, MS clamp made out of 50 x 6mm flat iron loop insulator 90mm x 140mm dia, hole 25mm porcelain complete all as specified and shown in electrical plate No 1 of SSR Part I . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender