Tender for Provn Of Servo Voltage Stabilizer At Various Water Supply Installations Under Age E/M-I Of Ge Dehradun
BOQ
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Supply, installation, testing and commissioning of 500 kVA Three-Phase Automatic Voltage Stabilizer, naturally oil-cooled, indoor type, suitable for operation on 3-phase, 415 V, 50 Hz AC system. The stabilizer shall be designed to maintain jerk less output voltage at 415 V ±1% for an input voltage variation from 350 V to 460 V confirming to BIS 9815 (Part-II).The vltage stabilizer shall have efficiency not less than 98% and shall be free from distortion in wave forms. The unit shall be complete with servo-controlled voltage correction system, copper-wound transformer, oil-immersed construction, protection against overload, short circuit and over/under voltage conditions, digital metering/indication for input and output parameters, necessary control circuitry, terminal arrangements, foundation hardware and all accessories required for satisfactory operation, complete all as specified and dircted. |
| 3 | Description all as per item No 1 above but cpacity 300 kVA complete all a specified and directed. |
| 4 | Description all as per item No 1 here in before but cpacity 100 kVA complete all a specified and directed.Note for Item No 1 to 3: (a) Servo voltge stabilizer shall be conforming to BIS 9815(Part-I) : 1994 (Second Revision).The performance requirement should be as per para 9 of the BIS 9815 (Part- I) which is reproduced as under:-(i) The corrector shall keep the outut voltage within ±1% of the rated voltage irrespective of load and input voltage range, as per clause 9.1 of BIS.(ii) the rate of correction of voltage shall not be less than 6 V/s between phase and neutral. The corrector shall be free from hunting during automatic operation, as per clause 9.3 and 9.4 of BIS.(iii) The manufacturer shall state the no load and full load losses corresponding to minimum and maximum rated input voltages. The tolerances on thes declared values shall be provided in Table 7 of IS 2026 (Part-I) : 1977. The no load cureent shall not be more than 5% of the rated output current, ref clause 9.4 & 9.5(iv) The efficiency of servo voltage stabilizer shall not be less than 95% as per clause 9.6 of BIS.(b) The testing of servo voltage stabilizer should be carried out in accordance with para 1.2 of the BIS 9815 (Part-I)(c) Type test report as per clause 11.1 for any rating as per clause 5.1 of BIS 9815 (Part-I) should be produced by manufacturer for the specified capacity / next higher capacity of any voltage range from Govt. Lab / NABL accredited Lab. |
| 5 | Excavation in trenches in soft or loose soil not exceeding 1.5 Meter wide and not exceeding 1.5 Metre deep in any type of soil including cutting in slopes etc. for laying of pipe line including getting out, complete all as specified and directed. |
| 6 | Supply and fixing of HDPE DWC pipe of size 110/90 mm dia as per IS 16205 for laying of XLPE cable, complete all as specified and directed. |
| 7 | Returning, filling in, including spreading, leveling, watering and well ramming in layers in soft / loose soil not exceeding 25 cm in each layer complete all as specified and directed. |
| 8 | Removal of excavated material (Soil) to a distance up to 50 Metre from starting point and depositing where directed at level not exceeding 1.5 Meter above as directed. |
| 9 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 240 sqmm 3.5 core, laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size complete all as specified and directed. Notes: (a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately.(b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.(c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. |
| 10 | Description all as per item No 8 above but , electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 120 sqmm 3.5 core, complete all as specified and directed. |
| 11 | Description all as per item No 8 above but , electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 95 sqmm 3.5 core, complete all as specified and directed. |
| 12 | Supply, installation, testing and commissioning of Outdoor Feeder Pillar Box, fabricated from CRCA steel sheet of minimum 2.0 mm thickness, floor-mounted, weatherproof construction with IP55/IP65 protection, suitable for housing 1 No. 630A, 3 Pole MCCB complete with gland plates, mounting arrangements, earthing studs, neoprene gasket, powder-coated finish, and adequately sized cable termination space. The feeder pillar shall be provided with front and side openable access doors/panels, fitted with heavy-duty hinges and a padlockable locking arrangement to secure all openable sides/doors. The enclosure shall be suitable for outdoor installation and complete in all respects as required complete all as specified and directed. |
| 13 | Supply, installation, testing and commissioning of Outdoor Feeder Pillar Box, fabricated from CRCA steel sheet of minimum 2.0 mm thickness, floor-mounted, weatherproof construction with IP55/IP65 protection, suitable for housing 1 No. 400A, 3 Pole MCCB complete with gland plates, mounting arrangements, earthing studs, neoprene gasket, powder-coated finish, and adequately sized cable termination space. The feeder pillar shall be provided with front and side openable access doors/panels, fitted with heavy-duty hinges and a padlockable locking arrangement to secure all openable sides/doors. The enclosure shall be suitable for outdoor installation and complete in all respects as required complete all as specified and directed. |
| 14 | Supply, installation, testing and commissioning of Outdoor Feeder Pillar Box, fabricated from CRCA steel sheet of minimum 2.0 mm thickness, floor-mounted, weatherproof construction with IP55/IP65 protection, suitable for housing 1 No. 160A, 3 Pole MCCB complete with gland plates, mounting arrangements, earthing studs, neoprene gasket, powder-coated finish, and adequately sized cable termination space. The feeder pillar shall be provided with front and side openable access doors/panels, fitted with heavy-duty hinges and a padlockable locking arrangement to secure all openable sides/doors. The enclosure shall be suitable for outdoor installation and complete in all respects as required complete all as specified and directed. |
| 15 | Supply, installing, commissioning and testing of LT panel outdoor type of size a per manufacturer recommendations not less than 2000x1500x600 mm CPRI certified factory made cubical type weather and vermin proof, rating IP- 65/66 fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 70x70x6 mm, 3 phase 4 wire 415 volts 50 Hz fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45 cm and gap between busbar not less than one inch) and double door handle including locking arrangement with 1 No pad lock of 65 m as directed before manufacturing the panel complete all as specified and directed.(A) Incoming MCCB 4 Pole, 415 V, Thermal magnetic release, Adjustable type, 250 Amps with breaking capacity 36 KA- 01 Nos(B) Outgoing MCCB 3 Pole, 415 V, Thermal magnetic release, Adjustable type, 125 Amps with breaking capacity 36 KA- 03 Nos( Spare MCCB- 1 Nos)Voltmeter (0-500) volts Digital type with selector switchesDigital type Ammeter (0-250) Amp with resin cast CT- 250/5 and selector switchLED indicating lamp assembly R,Y,B phase - 03 set |
| 16 | Material and labour for earthing complete with galvanised earth plate electrode 600x600x6.0mm thick, buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected with galvanised iron earth strip 25x4mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel complete with 40 mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test piont etc. in and including light frade GI protection pipe 40mm bore up to 7.5m lenght for drawing in earth lead wire , all as shown in electrical plate No.3 of SSR Part-1 complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified and directed. NOTE: (i) Earth lead strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted.(iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender