Tender For Special Repairs To Solar Water Heater At Various Locations At Hqtc Banglaore
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Aug 2026
19 days left
EMD
77860
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Solar Water Heater At Various Locations At Hqtc Banglaore
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK : SPECIAL REPAIRS TO SOLAR WATER HEATER AT VARIOUS LOCATIONS AT HQTC BANGLAORE CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Taking down carefully old unserviceable solar tank with solar plate of any capacity and any height and all accessories complete all as specified and as directed by Engr-in-charge. |
| 3 | Supply and fix in repair solar water storage tank 100 ltrs capacity made of heavy-gauge food-grade stainless steel (SS 316) to prevent corrosion and rust from constant water and having space between the inner and outer tank filled with high-density polyurethane foam (PUF) to drastically reduce heat loss, keeping water hot for up to 72 hours and capable of storing water between 60°C to 90°C temperature and including electric immersion heater with thermostat switch, temperature and pressure valve for safety including all accesories as per site requirement complete all as specified and as directed by Engr-in-charge. |
| 4 | Supply and fix in repair solar water storage tank 110 ltrs capacity made of heavy-gauge food-grade stainless steel (SS 316) to prevent corrosion and rust from constant water and having space between the inner and outer tank filled with high-density polyurethane foam (PUF) to drastically reduce heat loss, keeping water hot for up to 72 hours and capable of storing water between 60°C to 90°C temperature and including electric immersion heater with thermostat switch, temperature and pressure valve for safety including all accesories as per site requirement complete all as specified and as directed by Engr-in-charge. |
| 5 | Supply and fix in repair solar water storage tank 200 ltrs capacity made of heavy-gauge food-grade stainless steel (SS 316) to prevent corrosion and rust from constant water and having space between the inner and outer tank filled with high-density polyurethane foam (PUF) to drastically reduce heat loss, keeping water hot for up to 72 hours and capable of storing water between 60°C to 90°C temperature and including electric immersion heater with thermostat switch, temperature and pressure valve for safety including all accesories as per site requirement complete all as specified and as directed by Engr-in-charge. |
| 6 | Supply and fix in repair solar water storage tank 300 ltrs capacity made of heavy-gauge food-grade stainless steel (SS 316) to prevent corrosion and rust from constant water and having space between the inner and outer tank filled with high-density polyurethane foam (PUF) to drastically reduce heat loss, keeping water hot for up to 72 hours and capable of storing water between 60°C to 90°C temperature and including electric immersion heater with thermostat switch, temperature and pressure valve for safety including all accesories as per site requirement complete all as specified and as directed by Engr-in-charge. |
| 7 | Supply and fix in repair flat plate collector (FPC) solar collector panel suitable for existing roof top solar water heater system based of toughned tempered glass of 4mm thick and cladding with aluminium sheet 26 SWG complete with copper rising tube, copper heater tubes, copper sheet and absorber for solar water heater of capacity 300 LPD and size not less than 2000x1000x100mm and including all fittings and accesories as per site requirement complete all as specified and as directed by Engr-in-charge. |
| 8 | Material and labour for sub main wiring with two single core 4 sqmm PVC insulated, unsheathed, FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC conduit 25mm dia ISI marked broken white or of cream colour with all accessories such as tee, bend, joint cover etc., screws, gutti/ roul plugs PVC all as per site requirements including fixing on surface on stone walls/ brick masonary walls /ceilings /floors etc., with 4 sqmm PVC insulated, unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces with plaster and matching with the existing colour of wall /floor etc., and colour coding of cables such as Phase-Red, Neutral-Black, and Earth-Green complete all as specified and as directed by Engr-in-charge.Note: Two run of 4 sqmm single core cable and one run 4 sqmm earth wire including PVC conduit 25mm dia together will be measured as one unit. |
| 9 | Supply and fix for sheet metal enclosure for DB's double door SPN, 8 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 230 Volts complete all as specified and as directed by Engr-in-charge. |
| 10 | Supply and fix for MCB SPN, 40 Amps, 230 V, C- series with breaking capacity of 10 KA complete all as specified and as directed by Engr-in-charge. |
| 11 | Supply and fix for MCB SP, 6-32 Amps, 230V, C- series with breaking capacity of 10KA complete all as specified and as directed by Engr-in-charge. |
| 12 | Material and labour for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron wire 4mm dia as earth lead up to test point with suitable size GI nuts /bolts, washers, check nut and brazed properly up to main board, LT panel etc., and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates, 40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10mm thick with hinged and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore up to main board complete all as shown in electrical plate No 3 of MES schedule Part-I, connected to earthing testing point and testing on completion complete all as specified and as directed by Engr-in-charge.Notes: (i) The unit rate includes 15mm dia GI pipe upto 7.5m for protection of earth lead.(ii) The unit rate includes galvanised iron wire 4mm dia from earth electrode to test point up to 7.5m.(iii) In case measured value of earth resistance of each earthing is recorded more than 3 ohms then the earthing shall be re-done by the contractor without any extra cost to the Govt till desired result is obtained.(iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge/ JE E/M and proper record shall be maintained duly signed by all concerned.(v) Earth resistance tester will be provided by the contractor. |
| 13 | Supply and fix for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing 4mm dia galvanised iron or steel wire complete all as specified and as directed by Engr-in-charge. |
| 14 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in soft /loose soil complete all as specified and as directed by Engr-in-charge. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick in soft /loose soil complete all as specified and as directed by Engr-in-charge. |
| 16 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge. |
| 17 | Supply and fix in repair galvanised iron water tubes of size 15mm dia medium grade including all fittings as per site requirement and laid in trenches/ fixing on wall /floor /ceiling /roof or any place as per direction complete all as specified and as directed by Engr-in-charge. |
| 18 | Supply and fix in repair galvanised iron water tubes of size 20mm dia medium grade including all fittings as per site requirement and laid in trenches/ fixing on wall /floor /ceiling /roof or any place as per direction complete all as specified and as directed by Engr-in-charge. |
| 19 | Supply and fix in repair galvanised iron water tubes of size 25mm dia medium grade including all fittings as per site requirement and laid in trenches/ fixing on wall /floor /ceiling /roof or any place as per direction complete all as specified and as directed by Engr-in-charge. |
| 20 | Supply and fix in repair galvanised iron water tubes of size 40mm dia medium grade including all fittings as per site requirement and laid in trenches/ fixing on wall /floor /ceiling /roof or any place as per direction complete all as specified and as directed by Engr-in-charge. |
| 21 | Supply and fix in repair gun-metal, globe or gate valves, 20mm dia heavy duty, with iron wheel head, screwed both ends (ISI marked) including all fittings as per site requirement nuts, bolt and washers etc., complete all as specified and as directed by Engr-in-charge. |
| 22 | Supply and fix in repair gun-metal, globe or gate valves, 25mm dia heavy duty, with iron wheel head, screwed both ends (ISI marked) including all fittings as per site requirement nuts, bolt and washers etc., complete all as specified and as directed by Engr-in-charge. |
| 23 | Supply and fix in repair gun-metal, globe or gate valves, 40mm dia heavy duty, with iron wheel head, screwed both ends (ISI marked) including all fittings as per site requirement nuts, bolt and washers etc., complete all as specified and as directed by Engr-in-charge. |
| 24 | Supply and fix in repair 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position specified in SSR part I including all fittings as per site requirement complete all as specified and as directed by Engr-in-charge. |
| 25 | Supply and fix in repair ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe of size 25mm dia and fixed complete all as specified and as directed by Engr-in-charge. |
| 26 | Material and labour for sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/ PCC cover, punning of sand using suitable T&P as per site requirement complete all as specified and as directed by Engr-in-charge.Note: Only punned thickness shall be measured for payment. |
| 27 | Supplying and laying un-reinforced precast concrete cable cover class LV, Type 1, flat, size 250x150x40mm complete all as specified and as directed by Engr-in-charge. |
| 28 | Taking out unserviceable cable any type /size from trenches, pole, road, duct etc., including necessary joints, unserviceable fittings and pipes etc., complete all as specified and as directed by Engr-in-charge. |
| 29 | Supply and laying in trenches /laid in floor /duct /drawn through conduit XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100 V grade with aluminum conductor of cross sectional area 10 sqmm 2 core including suitable size lugs complete all as specified and as directed by Engr-in-charge. |
| 30 | Supply and laying in trenches /laid in floor /duct /drawn through conduit XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100 V grade with aluminum conductor of cross sectional area 16 sqmm 4 core including suitable size lugs complete all as specified and as directed by Engr-in-charge. |
| 31 | Disconnecting and taking out old rusted pipe and Material and labour for 25mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including flat Iron clamps 02 nos of size 25x5mm with nuts, bolts and washers complete all as specified and as directed by Engr-in-charge. |
| 32 | Disconnecting and taking out old rusted pipe and Material and labour for 50mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc., including flat Iron clamps 02 nos of size 30x5mm with nuts, bolts and washers complete all as specified and as directed by Engr-in-charge. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender