Tender For Provision Of Security Wall And Guard Post In Fd Hosp At Pattan Under Ge 969 Ews
Tender Overview
Project Description
Tender for Provision Of Security Wall And Guard Post In Fd Hosp At Pattan Under Ge 969 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Aug-2026 | Corrigendum Date 01 | Date | 02-Sep-2026 |
| 2 | 27-Aug-2026 | Corrigendum Date 02 | Date | 12-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Note: (i) Please refer Schedule 'A' Notes given in tender documents.(ii) The Schedule 'A' Part-XIII is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col. 5 signifies this fact only. |
| 2 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I. |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-II. |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-III. |
| 6 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-IV. |
| 7 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-V. |
| 8 | Lump sum price worked out by the contractor for COMPOUND WALL, FENCING AND GATE WORKS carried forward from Pre-Priced Schedule 'A' Part-VI. |
| 9 | Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-VII. |
| 10 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII. |
| 11 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-IX. |
| 12 | Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-X. |
| 13 | Lump sum price worked out by the contractor for DEMOLITION AND DISMANTLING WORKS carried forward from Pre-Priced Schedule 'A' Part-XI. |
| 14 | Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-XII. |
| 15 | MISCELLANEOUS ITEMS OF WORKS (SCHEDULE 'A' PART-XIII)(A) COMPOUND WALL, FENCING AND GATE WORKS |
| 16 | S&F Punched Tape Concertina coil dia 600mm (including Spike and Handle) with 50 turns and dia 1050mm. Max covered length 10RM, having a core wire of high carbon spring steel of high tensile strength. The punched tape and core wire (2.6 + 0.35mm dia) are electro galvanized to provide protection against out door exposure. The punched tape shall be mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of the coil; steel clamps \\" total 129 Nos per coil spaced\\" to connect the individual turns of the coil to each other so that it opens up like an accordion. The widyh of strip as 19mm and spacing of blades 24.00 + 0.5mm C/C The weight of each coil will be 15.2 + 5% Kgs without packing material and coil length 15 mtr when opened up with an effective height 915mm each coil wound with bituminized hessain cloth for providing protective packing ref specification No CQAE/5660/1602/a foe raw material and drawings IMGA-0112/B ( Sheet 1 of 2 ), IMGA - 0112/C (Sheet 2 of 2 ) IMPD - 1817/B, IMPD -1820, IMPD-1821, IMPD-1822 completeall as specified & directed. |
| 17 | (B) EXTERNAL WATER SUPPLY WORKS |
| 18 | M&L for cutting existing GI pipe 50 mm dia for inserting the valves ,fittings shall be done in a neat and workman like manner without damage to the pipe so as to leave a smoth ends at right angle to the axis of the pipe and opening the pieces by excavation and fixing the MS flange of Size 70mm Dia nos two ends of existing pipe welding in position for taking branch connecton for proposed GI pipe 25MM dia and insertion of Tee (50x 50x 25)duly welded with GI union 25mm dia including short piece etc.complete all as specified and directed. |
| 19 | (C) EXTERNAL ELECTRIFICATION WORKS |
| 20 | Supply and fix loopin loopout fuse junction box of size 205 x 255x 112 mm made out of thermo plastic Polycarbonate with IP 66/67 weather proof for outdoor installation (with knockouts of cable entry) protection with terminals and locking screw fitted with 5 Amps fuse cutout-01 No with 6A MCB, suitable for cable size 10 sqmm and fixing on steel tubular pole at a height not less than 1.5m above ground level with the help of clamps two nos of F1 20 x 3 mm and suitable nuts and bolts compelete all as specified and directed. |
| 21 | M&L for installation, commissioning & testing of LT panel board (Main Panel) outdoor type fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, double door type accessible from front and rear side both with locking arrangement 3 phase 1.5 Sqmm single core copper wire system at AC 440 V, 50 HZ with colour coded aluminium bus bar of rated current capacity 400Amp complete applied with two coats of synthetic enamelled paint over a coat of anti-corrosion primer and mounted on angle iron of size 50x50x6 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories : - Supply and fabricated LT distribution panel board with 3.15 mm thick CRCA sheet Aluminium busbar 4 strip with Coloured R,Y,B & Neutral of size (32x6) mm.Angle iron for frame work of size 50x50x6mm thick for panel mountingINCOMING MCCB Four pole MCCB 40 Amp,50Hz 415 Volts with rupturing capacity 25 KA - 01 No OUTGOINGMCCBs Four pole MCCB 25 Amp, 50Hz 415 Volts with rupturing capacity 16KA-01 Four pole MCCB 16 Amp, 50Hz 415 Volts with rupturing capacity 16KA, -01DP 10 Amp, 50Hz -03 Indicator LED lamp R,Y,B Digital volt meter 0-500 volt with selector switchDigital Ammeter 0-400 Amps with suitable CTsNOTE : Cost for construction of platform for panel of brick masonry work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No extra payment will be made. |
| 22 | M&L for installation, commissioning & testing of LT panel board (Main Panel) outdoor type fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, double door type accessible from front and rear side both with locking arrangement 3 phase 1.5 Sqmm single core copper wire system at AC 440 V, 50 HZ with colour coded aluminium bus bar of rated current capacity 200 Amp complete applied with two coats of synthetic enamelled paint over a coat of anti-corrosion primer and mounted on angle iron of size 50x50x6 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories : - (DG Panal)Supply and fabricated LT distribution panel board with 3.15 mm thick CRCA sheet Aluminium busbar 4 strip with Coloured R,Y,B & Neutral of size (32x6) mm.Angle iron for frame work of size 50x50x6mm thick for panel mountingINCOMING MCCBFour pole MCCB 25 Amp,50Hz 415 Volts with rupturing capacity 16 KA - 01 No OUTGOING MCCBsFour pole MCCB 16Amp, 50Hz 415 Volts with rupturing capacity 16KA - 02 NoIndicator LED lamp R,Y,B Digital volt meter 0-500 volt with selector switchDigital Ammeter 0-400 Amps with suitable CTsNOTE : Cost for construction of platform for panel of brick masonry work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No extra payment will be made. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 14 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender