Tender For E. I To Additional Material Recovery Facility (Mrf) And (Mcc)At - Pipalpadar Of Titilagarh Municipalty.
Tender Value
8.46 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
8 days left
EMD
8466
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for E. I To Additional Material Recovery Facility (Mrf) And (Mcc)At - Pipalpadar Of Titilagarh Municipalty.
BOQ
| Sl. No. | Item Description |
| 1 | Recessed wirring to light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make-Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Gloster with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal modular type (flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand (Myrius)/Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/legrand(Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineering Charge. For MCC a)1 GROUP-A |
| 2 | GROUP-B |
| 3 | GROUP-C |
| 4 | For MRF GROUP-A |
| 5 | GROUP-B |
| 6 | a-3) GROUP-C |
| 7 | Supplying, fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in-Charge. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision). For MCC |
| 8 | For MRF |
| 9 | Supplying, fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) (flame retradant type) with suitable size modular box & metallic cover plate (both side) (flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic (vision) (For equipement power) (Maximum 02 nos point in one circuit). For MCC |
| 10 | For MRF |
| 11 | Supplying, fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)( flame retradant type) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand(Myrius)/Panasonic (vision) (Incl. AC Point) For MCC |
| 12 | For MRF |
| 13 | 5 Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Gloster in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) For MCC |
| 14 | For MRF |
| 15 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Gloster in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (BDB to LSB/LIGHT CKT/SA PLUG/UPS POINT) (2X2.5+1X1.5) For MCC |
| 16 | For MRF |
| 17 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finalex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Gloster in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) For MCC |
| 18 | For MRF |
| 19 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finalex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit. (PDB to PSB/ POWER POINT/AC POINT) (2x6+1x2.5) For MCC |
| 20 | For MRF |
| 21 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to 15-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty For MCC |
| 22 | For MRF |
| 23 | S/F of S step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in c harge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision) For MCC |
| 24 | For MRF |
| 25 | Sub-Head II (Light fitting Fixture & Fan) |
| 26 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove/Havells Efficiencia Neo/Usha Technix) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as par direction of Enesin Charee For MCC |
| 27 | For MRF |
| 28 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells/Philips/Wipro/Crompton/Bajaj). For MCC |
| 29 | For MRF |
| 30 | Supplying, installation, of exhaust fan of heavy duty industrial exsust fan 6000 mm sweep 1400 rpm with louvers ( Make-Havells/Crompton/Usha/Orient/Bajaj) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. For MCC |
| 31 | Supplying, installation, of exhaust fan of heavy duty 250 mm sweep 1400 rpm with louvers (Make-Havells/Crompton/Usha/Orient/Bajaj) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. For MCC |
| 32 | For MRF |
| 33 | BDBS,DB,AC DB, FLOOR PANELS, MCBS Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel, double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user, High quality polyurethane Gasket, the box and cover shall be fabricated to withstand IK09, the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks, with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/Schneider-Acti ) as per direction of Engg.-in-Charge . 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with For MCC |
| 34 | For MRF |
| 35 | S/F of 6way Double door MCB DB (Make-Anchor/Havells/Polycab/L&T) For MCC |
| 36 | For MRF |
| 37 | Supplying and fixing 20-40 amps rating, 240 volts, C series, 10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3/Siemens-Betaguard/Schneider-Acti)in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. For MCC |
| 38 | For MRF |
| 39 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, 10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/Siemens-Betaguard/Schneider-Acti )the existing MCB DB complete with connections as per direction of Engg.-in- Charge.For MCC |
| 40 | For MRF |
| 41 | (Earthing) INSTALLATION S/IT/C of materials and installation of Gl earth plate 600mmx600mmx6mm thick ISI marked with G. 1. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. For MCC |
| 42 | For MRF |
| 43 | 18 Providing and fixing 6SWG G.I. wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. For MCC |
| 44 | For MRF |
| 45 | Supply & laying of 1x 2.5 mm2 sub main for Inverter wiring For MCC |
| 46 | For MRF |
| 47 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. BUILDING VRF AC)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.In commer 01 по 250A 4P MCCB 25kA, with ROM & S. Link. withTMR based release with adjustable overload (Make-LEGRAND-DPX3/Siemens-3VA Model/Schneider-CVS/ABB Formula) (Icu=100%ics) with shunt trip.Busbar-04 numbers of 400Amps, Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.Out going- 04 nos 63A 4P MCB 10kA,C series, 415V. Make-LEGRAND-DX3/Siemens-Betaguard/ Schneider-Acti 9/ABB 58200Out going: 10 nos 40A 2P MCB 10kA,C,240V series Make LEGRAND-OX3/Semens Betaguard/Schneider-Acti 9/A88 58200Instrument- (1) 03 numbers phase indicating lamp with toggle switch & HRC Fuse(1) 01 set of MFM with CTS (DIGITAL)(Sicure/L&T, CT-KAPPA or equievalant make model) Supply & Laying of 35 sqmm 3.5 core aluminium armoured cable service cable |
| 48 | Supply & Laying of 35 sqmm 3.5 core aluminium armoured cable service cable |
| 49 | Supply & Laying of 16 sqmm 4 core aluminium armoured cable service cable Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender