Tender For Internal Electrification To Science Museum At Dam Site Tikhali Of Lower Indra Irrigation Project Under The Scheme Periphery Development Of Reservoir And Water Bodies For The Year 2026-27.
Tender Value
23.99 Lakhs
Estimated cost
Bid Submission
04 Aug 2026
8 days left
EMD
24000
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nuapada → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Internal Electrification To Science Museum At Dam Site Tikhali Of Lower Indra Irrigation Project Under The Scheme Periphery Development Of Reservoir And Water Bodies For The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | SUB-HEAD I (MODULAR WIRING ITEMS)Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kabel/ Kei with 20 mm dia HMS FRLS PVC conduit ISI marked Make- AKG/ Bec/ Precision/ Norpack/ Anchor/ Kinjal 6A modular type (flame retardant type) switch ISI marked Make- Schneider (Zencelo)/ legrand (Myrius)/ Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retardant type) Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) of suitable size, modular box with 1.5 sq.mm FRLS PVC insulated single core multistranded copper conductor as earth wire including all accessories and connection as per direction of Engineer-in-Charge. All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Each light point should have provision for ceiling rose and angle holder point. In all the rooms there shall be two types of switchboard- one for raw and the other one for emergency. The inverter switchboard shall include at least one fan, one light and one 6A emergency socket. |
| 2 | Group-A |
| 3 | Group-B |
| 4 | Group-C |
| 5 | Supplying, fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) (flame retardant type) & other required accessories of ISI marked as approved as per direction of Engg.-in-Charge. Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (Maximum 02 nos point in one circuit). All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 6 | Supplying, fixing of 6A Plug on the separate board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) (flame retardant type) & other required accessories of ISI marked as approved as per direction of Engg.-in-Charge. Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (Maximum 02 nos point in one circuit). All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 7 | Supplying, fixing of 1X16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket (modular type) (flame retardant type) with suitable size modular box & cover (flame retardant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (For equipment power). All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 8 | Supplying, fixing of 2X6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket (modular type) ((flame retardant type) with suitable size modular box & metallic cover plate (both side) (flame retardant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (For equipment power)(Maximum 02 nos point in one circuit). All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 9 | Supplying, fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( ( flame retardant type) with suitable size modular box & metallic cover plate (both side)( flame retardant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( |( Myrius))/ Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 10 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kabel/ Kei in recessed HMS FRLS PVC conduit of mentioned size Make- AKG/ Bec/ Precision/ Norpack/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. |
| 11 | 2 nos single core 1.5 sq.mm copper wire for phase and neutral and 01 no of single core 1.5 sq.mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5) |
| 12 | 2 nos single core 2.5 sq.mm copper wire for phase and neutral and 01 no of single core 1.5 sq.mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5) |
| 13 | 2 nos single core 4 sq.mm copper wire for phase and neutral and 01 no of single core 1.5 sq.mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit (2X4+1X1.5) (For power plug point) |
| 14 | 2 nos single core 6 sq.mm copper wire for phase and neutral and 01 no of single core 2.5 sq.mm copper wire for earth continuity conductor in 25 mm dia non metallic heavy duty conduit. (2X6+1X2.5) (For power plug point/AC Point) |
| 15 | 4 nos single core 6 sq.mm copper wire for phase and neutral and 02 nos of single core 4 sq.mm copper wire for earth continuity conductor in 32 mm dia non metallic heavy duty conduit (4X6+2X4) (Main Panel to LDB) |
| 16 | 4 nos single core 10 sq.mm copper wire for phase and neutral and 02 nos of single core 6 sq.mm copper wire for earth continuity conductor in 32 mm dia non metallic heavy duty conduit. (LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) (Main Panel to PDB) |
| 17 | Supply and installation of AC Point wiring 16-20A DP MCB & series with enclosure, Make:- Schneider/ Siemens/ Legrand/ ABB of suitable size as required as per direction of Engg.-in-Charge. All the Components should be warranted for a replacement period of 1 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 18 | Supply and fixing CALL bell (Ding dong type)/ Buzzer on the existing switch box cover. Make- Havells/ Anchor as required as per direction of Engg.-in-Charge. All the Components should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 19 | Supply and fixing of Bakelite angle holder/batten holder (Make- Anchor/ Havells) or equivalent reputed make A category ISI marked as approved/of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge. All the Components should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 20 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respects as per direction of Engineer in charge (Make- Schneider(Zencelo)/ Legrand( Myrius)/ Panasonic (vision)) |
| 21 | S/F of 10 wall Ceiling Channel Spot light or Track light cylindrical LED COB Spotlight of 10 watt of lumen flux 750-850 lumen, beam angle 38, IP Rating 20 etc. |
| 22 | LAYING OF HDPE PIPES & S/F OF SURFACE LED LIGHTSProviding, fixing and laying of 50 mm dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching (75 mm depth) and refilling as per direction of Engg.-in-Charge. |
| 23 | Providing, fixing and laying of 200 mm dia HDPE pipe (medium class) in ground complete with fitting incl. trenching (75 mm depth) and refilling as per direction of Engg.-in-Charge. |
| 24 | Supplying of Energy efficient surface/recess mounted square/round shape 10 W LED luminaire of dimension consists of white powder coated, die-cast Aluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 15 watt and lumen output of 1500 lumens, CRI not less than 80, CCT of 6000 degree K, THD less than 10%, with electronic driver, internal surge protection of 3 KV, L70 B50: 50000 Hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic / LT / Havells / Philips / Wipro / Crompton / Bajaj) The luminaire should be Replacement Warranty will be 2 years. |
| 25 | BDBS, DB, AC DB, FLOOR PANELS, MCBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel, double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3, integrated door earthing system offering additional safety to the user, High quality polyurethane Gasket, the box and cover shall be fabricated to withstand IK09, the DB should be properly pre-treated with 7 tank process and dry powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks, with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make- Legrand-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ ABB Ibus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 26 | 4 Way (8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incoming I-8 modules, sub incomer-12 module & out going-12 modules, suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, profited masking sheet, IP43-IK09 with metal door. Warranty on DB is 3 years. |
| 27 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/RCCB/Isolator). Warranty on DB is 3 years. |
| 28 | 2+4 way MCB Enclosure DB (GLAZED door). Warranty on DB is 3 years. |
| 29 | Supplying and fixing 6 to 32 amps rating, 240 volts, C series, 10KA breaking capacity, Double poles MCB of Make- Legrand-DX3 / Siemens-Betaguard / Schneider- Acti 9 / ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 year. |
| 30 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, 10KA breaking capacity, single poles MCB of Make- Legrand-DX3 / Siemens-Betaguard / Schneider- Acti 9 / ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 year. |
| 31 | Supplying and fixing 63 Amps rating series, 10KA breaking capacity, 4P 415 volts MCB Make- Legrand-DX3 / Siemens-Betaguard / Schneider- Acti 9 / ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 32 | EARTHING INSTALLATIONSupplying, installation, testing & commissioning of Earthing with copper earth plate 600 mm x 600 mm x 6 mm thick ISI marked including accessories and providing masonry with cover plate having locking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 33 | Supplying, installation, testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G.I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonry enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 34 | Providing and fixing SWG 6 GI wire on surface or in recess for loop earthing as required as per direction of Engg.-in-Charge. (to be used for Street Light) |
| 35 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 36 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Main LT panel earthing. |
| 37 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 38 | Supplying of Energy efficient surface/recess mounted square/round shape 10 W LED luminaire consisting of white powder coated, die-cast Aluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 15 watt and lumen output of 1500 lumens, CRI not less than 80, CCT of 6000 degree K, THD less than 10%, with electronic driver, internal surge protection of 3 KV, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells/Philips/Wipro/Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender