Tourism Government Departments Closing in 11 days TDR #56633490

Tender For Integrated Development Of Khandagiri - Phase-I

Issued by Government Departments · Khordha, Odisha
Tender Value
18.72 Crore
Estimated cost
Bid Submission
07 Aug 2026
11 days left
EMD
18.72 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Integrated Development Of Khandagiri - Phase-I

BOQ

Name of Work:- Integrated Development of Khandagiri – Phase-I
Sl. No. Item Description
1CIVIL WORKS
2Earthwork in excavation upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in all kinds of soil including ordinary soil, hard/gravelly soil and stony earth mixed with stone and boulders etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge.
3Filling foundation trenches and plinth with excavated earth (excluding rock) including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge.
4Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for complete the work as per direction of the Engineer-in-charge.
5Providing & laying cement concrete of prop. (1:3:6) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for complete the work as per direction of Engineer-in-charge.
6Providing, lifting, hoisting and laying Reinforced cement concrete work of M-25 grade having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for complete the work in all respects as per drawing, design and direction of Engineer-in-charge. (But excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills.)
7Foundation
8Plinth Beam
9Beam & Column
10Roof Slab
11Providing & fixing TOR Fe-500 D grade reinforcement bars of approved makes for RCC work of required diameter with straightening, cutting, bending, binding welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing fan hooks, hoisting, lowering and laying including cost, conveyance and taxes of tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the drawing, design and direction of Engineer-in-charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.)
12Brick work in foundation and plinth with flyash bricks of size 25cmx12cmx8cm in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer-in-charge.
13Brick work in superstructure with flyash bricks of size 25cmx12cmx8cm in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. complete as per direction of Engineer-in-charge.
14Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to outside smooth surface of brick masonry walls after scraping, cleaning and racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge.
15Providing 6mm thick plaster in C.M. (1:4) over ceiling, chajja, loft, staircase, column, beams and walls after removing the false if necessary, scraping, cleaning and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, taxes of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge.
16Painting to external surface of building with two coats of weather coat over a coat of water based primer of approved shade and quality of approved design, after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance and taxes of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge.
17Providing and painting two coats with synthetic enamel paint over a coat of zinc oxide primer of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height including sand papering and making the surface smooth with cost, coveyance, loading and unloading, and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge.
18Dismantling brick or stone masonry in cement mortar under 3m height including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all material, labour, conveyance, loading and un-loading, royalties, sundries, tools and plants, etc., complete as per the direction of the Engineering-in-charge/Consultant.
19Removing old lime or cement plaster from walls in all floors including raking out joints 12mm deep and removing the debris within 50m lead etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineering-in-charge/Consultant.
20Dismantling steel sections, grill etc including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all material, labour, conveyance, loading and un-loading, royalties, sundries, tools and plants, etc., complete as per the direction of the Engineering-in-charge/Consultant.
21Supplying all labour, T&P for the Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge.
22Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction & Clause 305 of MoSRT&H Specifications for Road & Bridge works (5th Revision)
23Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (5th Revision) etc complete as per direction of Engineer-in-charge.
24Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works
25Providing and laying 80mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
26Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984
27Providing and painting two coats with synthetic enamel paint over a coat of zinc oxide primer of approved quality and approved shade confirmming to ISI on brick/rcc work to give an even shade in all floors at all height including sand papering and making the surface smooth with cost, coveyance, loading and unloading, and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge.
28Providing 16-18mm thick and above 0.40 Sqm size granite tile cladding of approved quality, colour and size in walls in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) (1 Cement: 3 Coarse sand) finished with modular pointing in white cement & pigment to match the shade of the granite including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour curing sundries and T & P etc. required for the work etc. complete as per specification and direction of Engineer-in-charge.
29Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge.
30Dismantalling and removal of old plain cement concrete from foundation, floor etc including stacking of servicable material and removal of debries to an unobjectionable area within 50 mtr lead etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge
31Dismantalling and removal of old RCC from beam, column, roof slab,self, chajja etc including stacking of servicable material and removal of debries to an unobjectionable area within 50 mtr lead etc. complete with cost, conveyance, loading and unloading, royalties of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge
32Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge
33Dismantalling and removal of old cement flooring etc including stacking of servicable material and removal of debries to an unobjectionable area within 50 mtr lead etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge
34Felling trees of 30 to 60cm girth (measured at a height of 1 m above ground level) and relocating the same inside the premises, including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
35Providing and laying plain cement concrete of (1:2:4) in foundation bed using 12 mm. Size black hard crusher broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required for the work etc complete as per the instruction of the Engineer-in-Charge.
36Supplying, fitting and fixing of M.S compound wall grills made out of ms flats, pipes, square bar etc (as per I.S. specification and as per approved drawings) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size (20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge.
37Supplying, fitting and fixing of M.S decorative grill gate made out of ms flats, pipes, square bar etc including brass mouldings (as per I.S. specification and as per approved drawings) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size (20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge.
38Providing and fitting TATA circular/square/rectangular Structural steel work welded in built up sections, trusses and framed work in straight/curve shape including cutting, hoisting, fixing in position and applying 2 coats of zinc chromate anti corrossive primer and 2 coats of synthetic enamel paint of approved shade etc complete as per the approved drawing & design and direction of engineer-in-charge.
39Supplying and laying full bed square granite cobbles of approved make and colour in approved pattern of 100mm x 100mm size having 75mm avg. thick over a 25-35mm bed of cement mortar of proportion 1:6 (1 cement : 6 sharp sand). The subbase for cobble stone should be prepared by spreading and compacting crushed stone or gravel in uniform layers not exceeding 100mm thick with proper gradient for drainage. Borders should be installed first to insure proper design layout and all the half stones should be removed to install continuous mat. Stones should be cut using a stone splitter if required. There should be a joint of 12mm thick and it should be free of leaves & debris. After laying the stones it should be compacted using a vibrating plate and compacting the bottom of the stone at least 3/8” into the subbase. After installation complete the dirt and debris should be clean off with an air blower and the top surface should be gently sweep for excess mortar off with the squeegee. Item includes cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries , T&P required for the work etc. complete in all respect as per manufacturers specification and direction of Engineer-in-charge.
40Providing and applying 2 coats of 1mm thick elastomeric cementitious waterproofing coating Brushbond RFX of Fosroc Chemicals Tested to ASTM D4060, ASTM D4541, ASTM D638, ASTM C836. with Adhesion to concrete : >1N/mm2 for waterproofing structures like roof slabs, sunken slabs, chajjas, tunnels, water tank etc. after proper surface preparation and soaking the surface with water prior to application complete as specified and directed by the Department at all levels.
41Providing and laying Khandolite stone masonry in cement mortar of mix (1:4) with Portland slag cement (PSC) and epoxy adhesive in foundation and plinth with screened and washed sharp sand for mortar of approved quality from approved quarry including providing key stones in regular intervals for each layer including splays cutting, circular moulding and similar such type of works with all necessary projections, champering and corbelling, watering and curing etc. with all cost, conveyance, royalties, loading & unloading of all materials and cost of all labour, sundries, T & P required for the work including hoisting, lowering, dewatering if required etc. complete in all respect as directed by Engineer-in charge.
42Providing and laying Khandolite stone masonry in cement mortar of mix (1:4) with Portland slag cement (PSC) in superstructure with screened and washed sharp sand for mortar of approved quality from approved quarry including providing key stones in regular intervals for each layer including splays cutting, circular moulding and similar such type of works with all necessary projections, champering and corbelling, watering and curing etc. with all cost, conveyance, royalties, loading & unloading of all materials and cost of all labour, sundries, T & P required for the work including hoisting, lowering, dewatering if required etc. complete in all respect as directed by Engineer-in charge.
43Providing and laying Khandolite stone ornamental/decorative masonry in cement mortar of mix (1:4) with Portland slag cement (PSC) in superstructure with screened and washed sharp sand for mortar of approved quality from approved quarry including providing key stones in regular intervals for each layer including splays cutting, circular moulding and similar such type of works with all necessary projections, champering and corbelling, watering and curing etc. with all cost, conveyance, royalties, loading & unloading of all materials and cost of all labour, sundries, T & P required for the work including hoisting, lowering, dewatering if required etc. complete in all respect as directed by Engineer-in charge.
44Providing and applying Exterior Colourless silicone water repellent coating of Nitocote SN522 evenly by spraying or brushing. Ensure an even coat over the entire surface. Porous surface should be well saturated with a two coat application Complete as per the manufacturer’s specification. Nitocote SN522 penetrates into concrete for a minimum depth of penetration of 2mm & complies with BS 6477-92 Class A and Class B as silicone - based water repellent.
45Providing, fitting and fixing 1700x400x500mm GFRC benches of approved quality and specification as per drawing, design and direction of Engineer-in-charge.
46Providing stone flooring/paving in heritage corridor using machine dressed khandolite stone with epoxy adhesive carefully by archaeological manner as per the drawing and design including cost, conveyance, loading and unloading, royalties of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge.
47Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of land manure before and after flooding trench with water (excluding the cost of imported earth, sludge or manure).
48Supplying and stacking of good earth at site (Earth measured in stacks will be reduced by 20% for payment) with all lead and lift.
49Supplying and stacking sludge at site (sludge measured in stacks will be reduced by 8% for payment) with all lead and lift.
50Supplying and stacking at site dump manure from dumping place nearest to site of work. (manure in stack will be reduced by 8% for payment) with all lead and lift.
51Screened through sieve of I.S designation 16 mm.
52Screened through sieve of I.S designation 4.75 mm.
53Rough dressing the trenched ground including breaking clods.
54Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of up rooted vegetation with all lead and lift.
55Fine dressing the trenched ground.
56Spreading of sludge, dump manure or land good earth in required thickness. (Cost of sludge, dump manure or/and good earth to be paid separately).
57Mixing earth and sludge or manure in proportion specified or directed.
58Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge
59Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
60Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 60 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (The manure/sludge shall be paid for separately).
61Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
62Holes 60 cm dia, and 60 cm deep
63Holes 45 cm dia, and 45 cm deep
64Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.
65Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge.Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm
66Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer incharge. (The cost of good earth, earthen pots & manure will be paid separately.) Size of Empty Pots 35cm Top dia, 25cm Bottom Dia & 35cm Perpendicular height.
67Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.
68Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
69Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
70Trees Plant
71Shrubs Plant
72Hedge Plant
73Providing and displaying of Aglaonema dove variety Plant, having ht. 30 cm to 45 cm with 8 to 10 leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
74Providing and displaying of Aglaonema Snow-White hybrid plant (three in one), having ht. 30 cm & above with 6 to 8 leaves, bright colour, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot . (Specimen Plant) & as per direction of the officer-in-charge.
75Providing and displaying of Areca Palm plant, having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 20 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
76Providing and displaying of Croton Challanger variety plant, having ht. 30cm and above, well developed with full of fresh and healthy leaves in 20 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
77Providing and displaying of Croton Baby Golden plant (three in one), having ht. 30cm, multi branches, well developed with fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot. as per direction of the officer-incharge.
78Providing and displaying of Dracaena Song of India plant (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
79Providing and displaying of Money Plant Broad Leaves mounted on moss stick 90 cm ht., 3 to 4 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot . & as per direction of the officer-in-charge.
80Providing and displaying of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
81Providing and Displaying plants Cladium Hybrid variety 3 to 4 plants in a pot well developed with fresh & healthy foliage 30 to 45 cm ht. in different colour 25 cm Earthen Pot/Plastic Pot and as per direction of the officer incharge.
82Providing and Displaying plants Cosmos well developed fresh & healthy 20 to 25 cm ht. attractive colours multi branching at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
83Providing and Displaying plants Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
84Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
85Providing and Displaying Acalypha green plant well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot bushy plant as per direction of the officer-in-charge.
86Providing and Displaying Bamboo Buddha vally variety with umbrella shape plant having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy plant as per direction of the officer-in-charge.
87Providing and Displaying Fishtail palm plant well developed with fresh & healthy foliage leaves of ht 210 to 240cm Specimen plant in 35 cm Cement Pot as per direction of the officer-in-charge.
88Providing and Displaying Foxtail palm plant well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge.
89Supply and stacking of Acacia auriculiformis plant of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge.
90Supply and stacking of Adansonia digitata (kalp vricksh) plantof ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge.
91Supply and stacking of Azadirachta indica ( Neem ) plant of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
92Supply and stacking of Bottle palm plant of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags.
93Supply and stacking of Casuarina equisetifolia plant of height 150-165 cm in big poly bags of size 25 cm as per direction of the officer-in-charge.
94Supply and stacking of Ficus nuda plant of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge.
95Supply and stacking of Nauclea cadamba (Kadam) plant of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.v
96Supply and stacking of plant Bauhinia acuminata height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
97Supply and stacking of plant Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge.
98Supply and stacking of plant Hibiscus rosasinensis of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge.
99Supply and stacking of plant Nerium oleander (kaner) dwarf of height 30-40 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.
100Supply and stacking of plant Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.
101Supply and stacking of Jasminum humile (Yellow) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
102Providing and fixing overhead type sprinkler system with self closing valve type 25mm X 20mm with self closing spring made up of alluminium alloy and brass fittings including cost of all materials, labour, T & P etc complete as per direction of Engineer-in-charge.
103provision of mentainance of the above landscaping work
104first year - @10%
105Second Year @7.5%
106Third Year @ 5%
107Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.
108Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
109Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge
110Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001
111Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
112Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
113Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).
114Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge.
115Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge.
116Providing and fixing letters made out of acrylic sheet with light arrangement as per the architectural drawing/design complete with all materials cost, coveyance, loading and unloading, royalties and cost of all labour, T&P, sundries, with necessary scafolding & accessories complete in all respects as per the direction of architect / engineer in charge.
117600mm height
118300mm height
119Plastic Waste bin Rectangular alongwith fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity-60 350x350 mm Top Dia.250x250 mm Bottom Dia.850 mm Height pair Sintex, Nilkamal, Otto, Aristo
120Plastic Waste bin without Wheel with Push type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level capacity 60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo
121Plastic Waste bin without Wheel with Swing lid type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity-60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo
122Location based signage: The signage structure is a combination of wrought/cast iron pipe structure with sandstone base and iron brackets. Stainless Steel Panel flags with symbol and text digitally H1625-RS printed on micro prismatic retro reflective boards conforming to type XI DG3 (diamond grade) 4000 series. Text language: Odia and English. Text height: Odia 55-60 mm; English 55-60 mm as per drawings & direction of Engineer in charge.
123Wayfinding signage: Mild steel panels (with/without wrought iron frame) screwed directly on wall. Text printed digitally H1625 -RS printed on micro prismatic retro reflective boards conforming to type XI DG3 (diamond grade) 4000 series. Text language: Odia and English. Text height: Odia 40-45 mm English 40 - 45 mm Century 30 -35 mm. Icon height: 155 - 175 mm as per drawings & direction of Engineer in charge.
124Story signage: DG3 digital printing series (super high efficiency reflective sheeting) with alphabets/ numerical/ pictorials digitally printed and laminated using 1170c laminate in matt finish. The base corresponds to a specific kind of pedestal i.e. Kani Pista, with three mouldings with 4:5:6 proportion. Concrete structure with text etched and painted on top. Sandstone cladding at the base text. Language: Odia and English. Text height: Heading - 10 mm Supporting text - 8 mm as per drawings & direction of Engineer in charge.
125Cultural marker: Providing and fixing 600 x 600 x 1800 mm (LXWXH) culture marker made of stone block with CNC etching and carving designs fixed over MS support structure made up of 150 X150 mm MS pipes with weather proof paint and primer fixed on the sub structure inclusive of all necessary hardwares to make structure stable as per site with complete base work and foundation and research, scriptwriting, proofreading and copywriting of all the content in 3 language (Oriya, Hindi & Englidh) with designing the and developing the infographics of all the graphical representation, illustration, theoraticaland textual content placement of provided content along with development of print ready files for the fabrication and production as/design/drawing with complete work as per site engineer incharge.
126Displays a brief introduction about the vicinity and the specific zones created within the Parikrama. Free standing structures made up of Khondolite Stone of 600 x 80 x 1800 mm. The signage has backlit brass metal letters. For lighting the letters, Fret cut fascia LED lighting is used.
127Displays Vicinity map and the location of structures in Oriya, English and Hindi language, with arrows for direction. Free standing structures made up of Khondolite Stone of 600 x 80 x 1500 mm. The signage has backlit brass metal letters.For lighting the letters, Fret cut fascia LED lighting is used.
128Displays names for the identification of structures and specific locations. Free standing structures made up of Khondolite Stone of 300 x 80 x 1200 mm. The signage has backlit brass metal letters. For lighting the letters, Fret cut fascia LED lighting is used.
129Signage for the identification of flora in the plaza such as aromatic, cyclone resisting, shading, cross pollinating, and medicinal species with the name of the tree.Free standing structures made up of Khondolite Stone of 450 x 80 x 1000 mm. The signage has backlit brass metal letters. For lighting the letters, Fret cut fascia LED lighting is used.
130Signage for preventing certain activities in respective locations within the premises.Free standing structures made up of Khondolite Stone of 450 x 80 x 1000 mm. The signage has backlit brass metal letters. For lighting the letters, Fret cut fascia LED lighting is used. The prohibition signage include; Noparking, Restricted areas, No entry zones, No mobile phones, No photography, No footwear, No spitting, No smoking, No eating or drinking.
131Size - 750 x 900 mm display MS coated Architectural poles on both sides of 750 mm width x 900 mm height display board. Content of display in Retro reflective background . Informationcontent as per artwork.
132Free standing unit made in 100 x 100 c/s pole and 450 x 450 mm Display up of Khondolite Stone, used as Identification sign
133ELECTRICAL WORKS
134Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
1353.5core x 150 sq mm DG
1363.5core x300 sq mm (MAIN PANEL MAIN IC)
137Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
138Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
139Supplying and making end termination with 3.5 core x150 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
140Supplying and making end termination with 3.5 core x300 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
141Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
14250 mm dia
143Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster)
144Supplying,laying of 3cx2.5 sq.mm AL armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster)
145Supplying,laying of 3cx6 sq.mm AL. armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster)
146Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
14750 mm dia
148MAIN CONTROL PANEL(OFP) NEAR IPC.S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 1+2 SPD 65 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 80X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory. All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 630A 4P Icu=100%Ics,36Ka LSIG MCCB with microprocessor release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.In commer-2- 01 number of 200A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Changeover- 01 no of 200A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB).Busbar-1&2 04 numbers of 800Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)Out going- 01 numbers of 200 Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Out going- 05 numbers of 125Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Out going- 02 numbers of 160Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Out going- 12 numbers of 100-63Amps 4P MCCB.Icu=100%Ics,16Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Out going- 1 number of 100Amps 4P MCCB Motorized .Icu=100%Ics,25Ka ,LSING ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula for Solar on grid integrate.Outgoing- 4 nos. 32A 4P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200.Outgoing- 8 nos. 32A 2P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200(Among it 2 nos with space for KWH Meter for shop).Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(iii) All the MCCB outgoing feeders shall have digital ammeter with CT of suitable class 1 rating.(Make-Legrand/Siemens/Schneider/ABB)(iv) 3P+N Type 1+2 SPD 65 kA with 100A 4P MCCB,25kA, TMR, Ics=100%Icu shall be installed in the incomers. (Make of SPD-Legrand/Siemens/Schneider/ABB),Make of MCCB-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula
149Supplying,installation,testing & commissioning Of Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per direction of Engg. in charge.
150Supplying & laying of 6 swg GI WIRE at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge.
151Supplying & laying of 25mm x 5 mm GI strip at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge.
152Supply, installation, testing and commissioning of LED Design based BIS approved LED Street Light with system power of 120W, CCT in 5700K as per ANSI) ,CRI>70, SDCM<3 , LEDs used should have a life of 50,000 burning hrs. & Lumen maintenance as per L70. The Luminaire System lumens should be >=19,200 Lumens @5700K. The fixture housing must be Made of ADC 12 PDC Aluminium housing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have a Ingress protection of IP66 and Impact Resistance of IK08. The light engine should use Metal Core PCB with high grade aluminium (AL5052) and should have a thermal conductivity of >2W/mK. The fixture should have an UV stabilized Injection moulded special PC lens optics(Glass not allowed) ensuring low glare & best in class uniformity. The light and the driver compartment should be thermally isolated by a natural airgap. Luminaire housing and optical compartment both should carry OEM's logo embossed / engraved (no stickering is allowed). The luminaire must have Integral encapsulated high efficiency electronic thermally isolated driver having a Aluminium extrusion construction with rated voltage of 100-300V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of min 6KV and upgraded with integrated IP67 protected SPD of 20KV/10KA surge protection with all necessary safety protection like mis-wiring, Over voltage, Short circuit, Reverse Polarity protection. . The compartment should be bottom openable for ease of maintenance at site. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. Following documents to be submitted after award of contract: Luminaire and Driver TDS, Photometry report, Type test certificate, IP, IK, Vibration and salt spray test certificates from NABL accredited Laboratory, LM80 from LED OEM., CE Certification, ROHS compliant, BIS Certificate for Luminaires & Drivers. The warranty on light fixture shall be 5 years. (Make: PHILIPS/ WIPRO/ BAJAJ/ Crompton/ PANASONIC/ LT/ HAVELLS)
153Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/ Bajaj/ RR Ispat/ Vakarangee as per direction of Engg. in Charge.
154Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge.
155Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with street light on that foundation(Details Drawing of the foundation attached). The work shall be excuted as per the direction of EIC.The structural calculation, wind load calculation and civil foundation shall be duly approved by the competent authority from civil wing (SE/CCE/Competant authority)before execution of the work.
156Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.The price inclussive of 3 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-300 + KL-5444 Luminaries / LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj).
157Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.Make-Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj/K-Lite.The price inclussive of of 4 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-400 + KL-5444 Luminaries/ LT/ panasonic/ Havells/ Philips/ Wipro/ Crompton/ Bajaj).
158Supplying, Erection, Fixing, connection & testing of 50W LED Heritage, GATE Light, Dimension of light must be Ø400mm dia and 800mm height, IP 66, IK07, amb. temp -10 to 45 degree celcious, CT 3000-5700K,,50000 HRS, CRI 70, 120 Lm/W system efficacy,driver efficiency >/ 85%,dia case aliminium housing,Clear Acrylic diffuser of Make-K-LITE Model No - 25444/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj as approved maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
159Bollard.Supply, Installation, Testing & Commissioning of of IP65 (16)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-K -lite Bollard KL-25582/ Philips/ LT/ PANASONIC/ Havells/ Bajaj/ Crompton/Wipro
160Focus Light.Supply, Installation, Testing and Commissioning of 18W LED Focus Light having CCT 3000K +/-355K as per ANSI , CRI>80, SDCM<3. The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare. The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-205V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : 3kV and upgraded with integrated External IP67 protected SPD of 10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. Make: K -lite Nebula KL-22782/LT/Havells/panasonic/Philips/ Wipro/ Crompton/ Bajaj).
161Focus Light.Supply, Installation, Testing and Commissioning of 50W LED Focus Light having CCT 3000K +/-355K as per ANSI , CRI>80, SDCM<3. The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare. The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-205V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : 3kV and upgraded with integrated External IP67 protected SPD of 10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Navi KL-26805/LT/Havells/panasonic /Philips/Wipro /Crompton/Bajaj).
162Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
1634core x 16 sq mm (OFP TO IND. TIMER PANEL)
1644 core x 4 sq mm (for small power/LIGHT TO POLE)
165Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
166Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
167Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
168Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
169Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make-POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster
170Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
17150 mm dia
172S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials.
173MINIMAST LIGHTING.Supply,installation,testing and commissioning of 8M mini mast shaft in two sections suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 6 luminaires in symmetrical arrangement and other accessories manufactured in factory. ( Bottom 360mm / Top -150mm, 3mm thickness, 445PCD, diameter of base plate 520mm including supplying of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation)along with foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template along with Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour . Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) Approved colour after treatment along with provision of masonary pedestal duly finished with plaster and painting with GI pipe for cable entering as required.. (2nos per mast required) (Make:-Bajaj/ Utkarsh/ Vakrangee/ RR ISPAT/ Valmont.
174SITC of 100W Outdoor Flood LED lights with silicon potted driver, IP66, , bottom opening maintanance , LPW not less than 130.Input Voltage: 85-265V AC ,Body : Die cast Aluminium, IP66 as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. Panasonic/ LT/ Havells /Philips/ Wipro /Crompton/ Bajaj as rerquired.
175LED type single dome aviation obstruction light. (Make:-Havells/Bajaj/ Utkarsh/ Vakrangee/ RR ISPAT.
176S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials.
177Solar light.Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonic/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect.
178Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 4 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge.
179Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge.
180Installation of 60W AIO LED solar street light on 8 mtr octagonal pole.
181GROUND RECESSED.Supply, Installation, Testing and Commissioning of 12W LED In-Ground light having die-cast aluminium housing with 316 Grade Stainless Steel front ring and coated with zinc rich primer & pure polyester powder coating of Jet Black Finish, UV Stabilized Clear toughened glass diffuser and with 3 coat Marine grade. CCT-3000K, CRI-≥70, IP-67, IK-09, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 2.5KV, Efficiency : >85%, Optical Distribution :120degree. Luminaries shall be provided with 3 Way IP68 connector. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-67 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite In-Ground KL-24473).
182SPIKE LIGHT.Supply, Installation, Testing and Commissioning of 18W LED focus light having die-cast aluminium housing and coated with zinc rich primer & pure polyester powder coating of Jet Black Finish, UV Stabilized Clear toughened glass diffuser and with 3 coat Marine grade. CCT-3000K, CRI-≥70, IP-66, IK-07, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 4KV, Efficiency : >85%, Optical Distribution :120degree. Luminaries shall be provided with 3 Way IP68 connector. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Nebula KL-4270).
183SPIKE LIGHT.Supply, Installation, Testing and Commissioning of 30W LED focus light having die-cast aluminium housing and coated with zinc rich primer & pure polyester powder coating of Jet Black Finish, UV Stabilized Clear toughened glass diffuser and with 3 coat Marine grade. CCT-3000K, CRI-≥70, IP-66, IK-07, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 4KV, Efficiency : >85%, Optical Distribution :120degree. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Nebula KL-24286). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56633490
AUTHORITY Government Departments
TENDER VALUE 18.72 Crore
LAST DATE 07-08-2026
Authority
Authority Name Orissa Tourism Development Corporation Limited
Work Description Tender for Integrated Development Of Khandagiri - Phase-I
Basic Detail
Tender No Integrated Development of Khandagiri Phase I
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 24 Jul 2026
Submission Date 07 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 18.72 Crore
Tender Fee 10000
EMD 18.72 Lakhs
Exemption Available
Document List
7b379884-97b2-4ead-b416-ef52af213159.html
BOQ_603153.xls
DTCN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

7b379884-97b2-4ead-b416-ef52af213159.html

xls

BOQ_603153.xls

pdf

DTCN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders