Tourism Government Departments Closing in 12 days TDR #56633489

Tender For Construction And Development Of Sand Art Park At Puri

Issued by Government Departments · Puri, Odisha
Tender Value
22.50 Crore
Estimated cost
Bid Submission
07 Aug 2026
12 days left
EMD
22.50 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Puri → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction And Development Of Sand Art Park At Puri

BOQ

Name of Work:- Construction and Development of Sand Art Park at Puri
Sl. No. Item Description
1Earthwork in the excavation of the foundation in all kinds of soil, including dressing and levelling the beds within 50m. initial lead and 1.5m. initial lift with cost, conveyance as per specification and direction of the Engineer in charge.
2SAND ART PARK
3AMPHITHEATER
4PLINTH PROTECTION
5BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
6Extra Lift 1.5m to 3.0m
7SAND ART PARK
8Back filling with available excavated earth in foundation and trenches in layer not exceeding 20 cm in depth watering ramming with a lead upto 50m and lift upto 1.5m etc. including cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge
9SAND ART PARK
10AMPHITHEATER
11BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
12Carriage / disposal of excavated surplus earth from the work side by mechanical means with a lead of 5 km. incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge
13SAND ART PARK
14AMPHITHEATER
15BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
16Filling foundation and plinth with good quality river sand with watering and ramming incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge.
17SAND ART PARK
18AMPHITHEATER
19PLINTH PROTECTION
20BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
21Cement concrete (1:3:6) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge
22SAND ART PARK
23AMPHITHEATER
24BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
25Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour, cess and T&P required for the work etc. complete in all respect.
26PLINTH PROTECTION
27Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour, cess and T&P etc. required for the work complete as per specification & direction of the Engineer-in-charge
28PLINTH PROTECTION
29R.C.C. work of Grade- M 30 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position as per specification & direction of the Engineer-in-charge
30SAND ART PARK
31GROUND FLOOR
32Foundation
33Column
34Plinth Beam
35Lintel
36R.C.C. floor roof slab
37R.C.C. Wall
38R.C.C. staircase
39FIRST FLOOR
40Column
41Lintel
42R.C.C. floor roof slabs
43R.C.C. staircase
44SECOND FLOOR
45Column
46Lintel
47Chajja
48R.C.C. floor roof slabs
49BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
50Foundation
51Column
52Plinth Beam
53Lintel
54Roof beam
55R.C.C. floor roof slab
56Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL including bending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost ,conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & directionof Engineer-in-charge Ground floor
57SAND ART PARK
58GROUND FLOOR
59FIRST FLOOR
60SECOND FLOOR
61BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
62Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and Plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard and as per specification & direction of Engineer-incharge.
63SAND ART PARK
64Foundation
65GROUND FLOOR
66FIRST FLOOR
67SECOND FLOOR
68PLINTH PROTECTION
69BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
70Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:4) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard and as per specification & direction of Engineer-incharge.
71SAND ART PARK
72GROUND FLOOR
73FIRST FLOOR
74Laterite Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and Plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard and as per specification & direction of Engineer-in charge. Foundation
75AMPHITHEATER
76Laterite Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and Plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard and as per specification & direction of Engineer-in charge. GROUND FLOOR
77AMPHITHEATER
78Providing and laying gabion wall using 80×100 mm double twisted hexagonal wire mesh gabion baskets of size 2×1×1 m, filled with approved hard stones of size 100–200 mm, including assembly, placing in position, filling, lacing, and tying complete as per drawing,all complete as per directions of Engineer-in charge.
79SAND ART PARK
80GROUND FLOOR
81FIRST FLOOR
82BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
83Supply and fixing of MCM Modified Clay Material ‐ MCM Laterite ‐ 300 x 600 mm of PHOMI make, as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation ‐ Class A— ASTM E84‐ 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in‐charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in‐charge.
84SAND ART PARK
85GROUND FLOOR
86FIRST FLOOR
87AMPHITHEATER
88BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
89Providing 16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge
90SAND ART PARK
91GROUND FLOOR
92FIRST FLOOR
93SECOND FLOOR
94BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
95GROUND FLOOR
96Providing 6mm thick cement plaster in cement mortar (1:4) in all floors finished smooth to inside RCC surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge
97SAND ART PARK
98GROUND FLOOR
99FIRST FLOOR
100SECOND FLOOR
101BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
102GROUND FLOOR
103Providing 18mm C.P. in two coats underlayer 12mm C.P. 1:6 and top layer 6mm thick C.P. 1:6 finished even and smooth on masonry walls including racking out joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and levels and providing grooves as shown in the drawing including cost of all materials, labour, conveyance, loading and unloading, royalty, scaffolding, watering, curing, sundries, tools and plants, etc., complete excluding GST as per the direction of the Engineer-in-charge.
104SAND ART PARK
105GROUND FLOOR
106FIRST FLOOR
107SECOND FLOOR
108AMPHITHEATER
109BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
110Providing 12 mm. thick cement plaster in plinth protection at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge.
111PLINTH PROTECTION
112Supplying, fitting and fixing full body glazed vitrified tile (Matt or Glazed ) flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of ( 600 x 600mm / 600 x 1200mm ) or of approved quality of colour in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry, grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST and direction of Engineer-in-charge. (Note- Sample of tiles shall be approved before procurement and use)(JHONSON/SOMANY/KAJARIA)
113SAND ART PARK
114GROUND FLOOR
115FIRST FLOOR
116SECOND FLOOR
117BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
118Supplying, fitting and fixing full body glazed vitrified tile (Matt or Glazed) in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of ( 600 x 600mm / 600 x 1200mm ) of approved quality of Somany/ Kajaria in dado/ skirting,riser of steps,wall on on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shadesof the vitrified tile if required watering and curing for 21 days,including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST and direction of Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use)(JHONSON/SOMANY/KAJARIA)
119SAND ART PARK
120GROUND FLOOR
121FIRST FLOOR
122SECOND FLOOR
123BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
124Supplying, fitting and fixing full body glazed vitrified tile (Matt Wooden Tiles ) flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of (200 x 1200mm ) or of approved quality of colour in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry, grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST and direction of Engineer-in-charge. (Note- Sample of tiles shall be approved before procurement and use)(JHONSON/SOMANY/KAJARIA) FIRST FLOOR
125SAND ART PARK
126Providing fitting and fixing of Granite stone tiles in floors of size over 20mm thick bed of cement mortar(1:4) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per the specification & direction of the Engineer-in-charge
127SAND ART PARK
128GROUND FLOOR
129FIRST FLOOR
130Providing fitting and fixing of Granite stone tiles in dadoes over 12mm thick bed of cement mortar(1:3) jointed with neat cement slurry mixed with pigment to match the shades of tiles, including cost, conveyances, royalties of materials, and Cost of all labour with T&P required for the work etc, complete as per the specification & direction of the Engineer-in-charge
131SAND ART PARK
132GROUND FLOOR
133FIRST FLOOR
134Providing and fixing in position wood plastic composite door frame with appropriate length of ETA Approved carbon steel galvanized (minimum 5 microns) double threaded 6.8 grade Polyamide PA 6 grade sleeve HRD C 10 anchor suitable for fastenings both on concrete & masonary/aerated blocks including cost of all materials, labours, T & P etc required for the work. complete in all respect as directed by the Architect/Engineer-in-charge
135SAND ART PARK
136GROUND FLOOR
137FIRST FLOOR
138SECOND FLOOR
139BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
140Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete as per specification & direction of the Engineer-in-charge
141SAND ART PARK
142GROUND FLOOR
143FIRST FLOOR
144SECOND FLOOR
145BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
146Supplying, fitting and fixing of M.S grills, Grill window (as per I.S. specification and as per approved drawings) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge ( W.I. / M.S. windows grills,grill gates,collapsible gates with top and bottom rails, steel windows,steel doors,steel frames for doors and windows,staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.)
147SAND ART PARK
148GROUND FLOOR
149FIRST FLOOR
150Finishing wall surface with water based wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges,conveyance, taxes of all materials and cost of all labour with TandP etc complete as per specification and direction of Engineer in charge
151SAND ART PARK
152STILT FLOOR
153FIRST FLOOR
154SECOND FLOOR
155BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
156Priming over the plastered surface with one coat of water bound cement primer of approved quality and make including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge , Inside wall
157SAND ART PARK
158GROUND FLOOR
159FIRST FLOOR
160SECOND FLOOR
161BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
162Painting with two coats with Plastic emulsion paint of approved quality,make and shade to give an even surface including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge Inside wall
163SAND ART PARK
164GROUND FLOOR
165FIRST FLOOR
166SECOND FLOOR
167BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
168Painting two coats with anti-fungal resistance Weather Seal Coat of approved shade upto any height by means of brush to outside surface of walls after cleaning the surface including watering, curring etc. complete in all floors including cost, conveyance,taxes of all materials,labours sundries T&P required for the work as per specification and direction of Engineer in charge
169SAND ART PARK
170GROUND FLOOR
171FIRST FLOOR
172SECOND FLOOR
173Priming with one coat of water bound cement primer to the external wall surface of approved quality and make including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P,etc. all complete as per the direction of Engineer-in-charge, Outside wall
174SAND ART PARK
175GROUND FLOOR
176FIRST FLOOR
177SECOND FLOOR
178Painting two coats with approved Synthetic enamel paints of approved colour,shade over a coat of primer in Iron work including sand papering, polishing the surface,cost,conveyances,taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge.
179SAND ART PARK
180GROUND FLOOR
181FIRST FLOOR
182SECOND FLOOR
183Providing, Fitting & Fixing of Stainless Steel of 304 grade in handrailing of 50mm dia of 2mm thick circular pipe with a balustrade of size 32mmX32mmX2mm @ 0.90mtr. C/C and stainless square pipes bracing of size 32mmx32mmx2mm in 3 rows in staircase as per the approved design and specification,buffing,polishing, etc., with cost, conveyance of Materials, Labour, TandP, etc required complete in all respect and as per specification & direction of Engineer-in-charge
184SAND ART PARK
185GROUND FLOOR
186FIRST FLOOR
187Providing 2.5cm thick grading concrete of prop.(1:2:2) on roof slab using 4.7 mm size H.G. chips of approved quality & from approved quarry including watering,curing with cost,conveyances, taxes of all materials,cost of all labour, T&P required for the work etc. complete as per direction of Engineer-in-charge FIFTH FLOOR
188SAND ART PARK
189Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits,wall trenches,basement excavation, top surface of plinth filling,junction of walls and floors along with external perimeter of the building,expansion joints,surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost,conveyance,loading, unloading and ,es of all materials, cost of all labour,T&P,sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.( The payment shall be made on the basis of the actual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment)
190SAND ART PARK
191AMPHITHEATER
192BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
193The glass shall be SGG made 12mm PLANITHERM Clear Toughened+16mm AIR GAP + 12mm Clear glass toughened clear, non-wired, toughened, with a light transmission of 72%, Internal and external reflection – 11% , Solar Factor (g) 0.53, Shading Coefficient (SC) 0.61 and sound reduction of 38 dB. The glass must be manufactured in an ISO 9001 audited facility.Supply of VDS fully glazed non-load-bearing fixed partition system. The frames shall be made with imported cold-rolled profiles. The frames are cold rolled from 1.5 mm steel sheet to form a profile of 50 mm x 50 mm on all sides. The system shall be tested as per EN 1364-1 in an internationally accredited laboratory. The glass shall be held in its place with the help of 1.25 mm cold-rolled steel beading and glazing tapes. The glass should be held in its place with the help of 1.5 mm cold-rolled steel beading and Kerafix 2000 ceramic tape with cross section of 4 x 15 mm as per the test evidence. The beading shall be clipped on using stainless steel self-tapping screws fixed at a distance of 70 mm from the edges and 150 mm c/c henceforth. The glass panes are to be supported on non-combustible 6 mm thick calcium silicate setting blocks. The maximum glazing size shall be as per the test certification. The profile has to be fixed to the supporting construction by means of M10 or bigger steel bolts at every 150 mm from the edges and every 500 mm (approx.) c/c. The partitions shall offer C4 level of wind resistance when tested as per EN12211 and shall provide class 4 level of air permeability as per EN 1026 as per specification & direction of Engineer-in-charge
194The profiles shall have a pure polyester powder coating of approved colour and finish. The profiles shall have 7 tank dip treatment before the powder coating. The powder coating shall be tested for 720 hours as per ASTM B117.Glass make -saint gobin as per specification & direction of Engineer-in-charge
195SAND ART PARK
196GROUND FLOOR
197FIRST FLOOR
198SECOND FLOOR
199Providing and lying integram cement based water proffing traetment including preparertion of surface as required for treatment of roofs, balconies, terrace etc consisting of following operations: (a) Applying a slurry cot of neaat cement using 2.75kg/sqm of cement aadmixed with water proffing compound comforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using briken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortr 1:5 (1 cement : 5 coaarse sand) admixed with water proffing ompound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick laayer of cement mortr of mix 1:5 (1 cement 5 coarse saand) admixed with water proffing compound conforming to IS : 2645 and approved by Enginer-in-charge to required slope and treating similarly the adjoining wall up to 300 mm height including rounding of junctions of waall and slabs. (c) After two dys of proper curing applying a second coat of cement slurry using 2.75 kg/sqqm of cement admixed with water proffing compound conforming to IS : 2645 and approved by Engneer-in-charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 Coarse cement sand) admixed with water proffing compound conforming to IS : 2645 and approved by Engneer-in-charge
200SAND ART PARK
201Providing and fixing of GFRC screens in approved design, size & thickness is 25mm thick border of 50mm +/- 5% as per drawing or giver pattern manufactured containg alkaline resistant glass fiber of make samudayam pvt lmtd. including cost of all material as per the requirement to be fixed for direct application on the wall ,there will not be a over lapping make in position with necessary accessories with scafolding complete in all respect excluding GST as directed by the Engineer-in-charge.
202SAND ART PARK
203FIRST FLOOR
204SECOND FLOOR
205BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
206Glass doorSupplying , fitting and fixing of openable UPVC doors with frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures as per direction of Engineer-in-charge
207SAND ART PARK
208FIRST FLOOR
209Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdor floors such as footpath, courtyard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge
210SAND ART PARK
211Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40grade of approved make,design ,colour and size made by block making machine with proper compaction laid in required patteren etc. complete in all respect conforming to IRC SP-63:2018 as per direction of Engineer-in-charge
212SAND ART PARK
213AMPHITHEATER
214Providing & laying precast, precured cement concrete (M-25 grade) Kerb stone (400x300x150mm) with graded stonne aggregates & fixing in position & pattern as shown in drawing with cement mortar of (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required including cost of all materials, labour, lead, T&P etc. complete in all respect (excluding GST) as per specification and as directed by Engineer-in-charge.
215SAND ART PARK
216Supplying and laying of Grass Pavers of M-30 grade MGP-1 (X-type) 60mm thick interlocking type including preparation of sub base with 100mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-charge.
217AMPHITHEATER
218Providing and fixing of factory made UPVC 2-track sliding/3 track window complete,comprising UPVC multi-chambered frame of size 67mmx54mm with wall thickness of 2.33mm (+-0.2mm) having inbuilt UPVC roller track on top and UPVC sash of size 64mmx47mm with wall thickness of 2.3mm (+-0.2mm) duly reinforced with G.I section 1.2mm (+/-0.2mm), whereever required. All corners of frame and sash will be fision welded. After placing 5mm clear Annealed glass in sash, UPVC glazing bead, interlock, EPDM gaskert, brush will be provided including hardware, i.e, touch lock and rollers & proper drainage system shall be provided. Window will be fixed to the wall with 100mm long and 8mm dia as per direction of EIC
219BOUNDARY WALL WITH SECURITY SHED & TICKET COUNTER
220STEEL WORK
221Supplying, fabricating, assembling, hoisting /erecting and fixing in position at all heights and with all leads, structural steel works of MS rolled sections/Plate as per structural drawings and as per detailed specifications (for materials & workmanship) in the situations described herein after complete rate shall including primer and 2 or more coats of paint by spray gun as per detailed specifications and manufacturer's recommendations. The welding elctrode to be used shall be E-7018 (radiographic quality) or equivalent as per IS classification. The grade of steel shall be E 350 as per direction of Engineer-in-charge.
222Fire retardant paint
223Providing and applying 2 hour fire rated paint
224DECK SHEET
225Providing and fixing metal deck sheet shall be TR-60 of 1.0mm thick with yeild stress of MPa 350 supported on Structural Steel beams and Columns which will serve as permanent shuttering to the roof slab of total thickness of 160mm thick & shall have adequate strength of support weight of green concrete and imposed loads during concreting as per manufacturer's recommendations / calculations / test certificates complete as per the details given in the drawings and as directed by Engineer-in-charge for In- situ roof slab. Measurement shall be of the plan area of roof covered metal decking(Excluding cost of concrete and reinforcement. Used shear studs to be provided as per requirement and direction Engineer In Charge. No payment will be made for sheet overlaps).
226Shear studs
22719mm dia 110 mm long
228ROOFING SHEET
229DOUBLE SKIN INSULATED ALUMINIUM STANDING SEAM ROOF SYSTEM:
230Supply and fixing of KALZIP/KING SPAN” SECRET FIX STANDING ROOFING SYSTEM IN 1.2mm THICK AA 3004/3005 ALUMINIUM ALLOY. The general roof-construction shall comprise from bottom to top:1. Bottom layer – Steel Trapezoidal liner – Solid trapezoidal sheets 30-35 mm deep – profile color coated Galvalume steel liner AZ150, 550 MPa, of 0.5mm thickness TCT, 1000 mm total cover width. The finish to the exposed surface of the liner will be RMP coating with film thickness of 15 to 20 microns & 5 to 7 microns primer on inner side complete 2 Other layers Vapor Control Layer – A single layer VCL, Polyethylene based vapor control membrane, reinforced with mono filament scrim to provide tensile strength. VCL weight 250 GSM, with Water Vapor permeability less than 0.39 grams / m2/ day. Insulation single layer of Rockwool insulation with 60 kg/m³ density,and total thickness of 100mm. Aluminum clips in grade 6061 T6 of suitable height with thermal barrier pads to be fixed to the sub purlins with SS 304 screws only.Top Hat and top hat bracket as required in 2.0 mm thick and 2mm thick Galvanised steel hat section to be fixed on trapezoidal Liner sheetsTop layer – Aluminum kz 65/400 , Straight / tapered curved profile sheeting manufactured from aluminum self-supported standing seam roof system from aluminum alloy AA 3004/ AA 3005 H46 (AlMn1Mg1) as specified in minimum material thickness of 1.2mm andconsisting of anti-corrosive primer 5 microns + Topcoat of PVDF 20 microns Total coating thickness is 25microns, +/- 2 microns.This Guard film prevents scratches during roll forming & handling. Bottom side shall be 5 microns Epoxy coating The material properties shall be as follows: Ultimate tensile strength minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, Sheets are to be laid to meet the requirements of the building geometry and fixed on Aluminum Clip to be fixed with SS 304 screws only. The roofing system manufacturer shall submit valid, Factory Mutual certificate in India BBA Certificate & The Institute of Bautechnic Zulassungbeschield N R -14.1 .181. Purlin spacing shall be maximum 1200mm complete as per direction of Engineer-in-charge.
231ALUMINIUM FLASHING FOR ROOF
232Aluminum Flashing Supply and fixing flashings manufactured from aluminum alloy AA 3004/3005 (AlMn1Mg1) as specified in BS EN 1396: 2015 minimum material thickness of 1.2mm of same finish as panel. Flashing girth to be 400mm to 578mm complete as per direction of Engineer-in-charge.
233EXTERNAL SINGLE SKIN GUTTERS
234Single Skin Gutters
235Gutters -supply and fixing of gutters as per detailed drawings consisting and aluminum gutter of 2mm in mill finish thickness, fabricated as per the sizes required. Supply and fixing of single skin 2 mm Aluminum gutter, GRADE AA 1100/AA1200 ALLOY with EPDM Expansion joints for every 6.0mtr length, Down take spout of 100- 250 mm at every 10mtr gutter length, & other accessories and welding at joints. The Girth of gutter shall be minimum 1200mm / as advice by the MEP consultant as per direction of Engineer-in-charge.
236PH WORK
237Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge .(Supreme/Ashirvad/Oriplast/AKG/Prayag)Ground Floor25mm dia PVC ASTM pipe (sch-80)
23832mm dia PVC ASTM pipe (sch-80)
239First Floor -25mm dia PVC ASTM pipe (sch-80)
24032mm dia PVC ASTM pipe (sch-80)
241Second Floor-40mm dia PVC ASTM pipe (sch-80)
24250 mm dia PVC ASTM pipe (sch-80)
243Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge.(Ashirbad /Astral/Supreeme) Ground Floor20mm dia CPVC pipe
24425mm dia CPVC pipe
245First Floor- 20mm dia CPVC pipe
24625mm dia CPVC pipe
247Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall Ground Floor
248First Floor
249Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.Ground Floor
250First Floor
251Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.
25215 mm dia 2 WAY BIB COCK WITH WALL FLANGE (FLR-CHR-5041N
25315mm dia CP Health faucet (ALD-CHR-573 Jaquar make)
25415 mm dia CP Long body Bib cock(Jaquar)CON-CHR-049NKN
25515mm dia CP Wall mixture three in one system with provision for both hand shower and overhed shower(Jaquar make FLR-5281N)
256Easy Flexible tube chrome finsh 1.5 m(Jaquar)SHA-ACR-549D12
257Hand shower100mm round shape jaquar make HSH-1937
258Premium wall bracket for Wall shower 35mm dia & 100mm long round shape (jaquar make SHA-555
259Over head shower 120 x 120 mm square shape jaquar make OHS -CHR-1603
260Shower arm 600x 25x25mm square shape Jaquar -SHA-ABR-457L200
26115mm dia CP Pillar cock (FLR-5015 Jaquar make)
26215mm dia CP Pillar cock (FLR-5441NK Jaquar make) Single concealed stop cock consisting of operating lever,cartridge sleeves,wall flenge with seals )basin spout (composite with ALD -441)
26315mm dia CP angle stop cock (FLR-5053N Jaquar make)
264BOTTLE TRAP ECO.MOD.WITH 190mm X 125mm (Jaquar make - ALD-ABR-773)
26515mm dia CP Sink Cock (FLR- CHR- 5347 NJaquar make)
266CP towel rail 600mm long (Jaquar make-AQN-7711)
267CP Towel Ring (Jaquar) ACN-CHR-1121N
268Coat hook jaquar make-AKP-C-35761P
269Towel Rack Jaquar make AHS-1581H
270Toilet paper holder Jaquar make -AHS-1551
271CP soap holder
272Soap Dispenser with glass bottle(ACN-CHR-1135N) ( Jaquar/Cera/hindware/equivalent Make)
27325mm dia CPVC Ball valve(Supreme/Ashirvad)
27432mm dia CPVC Ball valve(Supreme/Ashirvad)
27540mm dia CPVC Ball valve(Supreme/Ashirvad)
27650mm dia CPVC Ball valve(Supreme/Ashirvad)
27715mm dia CP flange
27815mm dia CP extension piece
279Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge.(Supreme/Ashirvad/Oriplast/AKG/Prayag)
280110mm dia U-PVC SWR pipe
281110mm U-PVC door tee
282110mm U-PVC Plain tee
283110mm U-PVC door bend
284110mm U-PVC plain bend
285110mm dia U-PVC 'P' trap
286110mm dia U-PVC Plain Shoe Bend
287110mm dia U-PVC offset with out ear
288110mm dia U-PVC cowl
289125mm dia CP grating
290Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall.
291Supplying all materials,labour,T&P and fixing 5000Ltr Roto-moulded cylindrical vertical water storage tanks on the roof of second floor. (Supreme/Ashirvad/ Oriplast/ AKG/Prayag) conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge(3 layer)
292Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.Rimless Single piece WC with PP soft close slim seat cover,Hinges,Dual flush cistern(CNS -WHT- 851S300SPPY)(jaquar make).
293Supplying all materials, labour, T&P and fixing of Rimless bowl with cistern for coupled WC(Single piece)(OPS-WST-15753N_180UFSMZ jaquar make) etc.all complete as per specification and direction of Engineer-in-charge
294Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.
295Half stall urinal (Jaquar make). URS-WHT-13253N Urinal (Back Inlet)
29615mm dia urinal spreader
29732mm dia C.P. dome waste
298URINAL PARTITION JAQUAR MAKE JSE-CHR-810US450X
299Supplying all materials ,labour ,T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste , fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc. including cutting holes in walls and making good the damages etc.all complete as per specification and direction of Engineer-in-charge
300600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make or equivalent)
301Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeTable top Basin 495X395X150mm jaquar make JDS-WHT-25909
302TABLE TOP BASIN 600 x 440 x165 mm Jaquar Make OPS-WHT-0557
303Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. Big mirror
304Design mirror
305Providing & fixing Greenlam/equivalent Sturdo Essentia Collection- Serene Restroom Cubicle (of following standard dimension which includes 600mm door size width) self-supporting 12mm thick compact laminates made out of, urea free, thermosetting phenolic resins treated Kraft papers as core material and Amino plastic resin treated decor papers on the finish surface, conforming to latest and applicable IS: 2046-1995, EN 438:2016 and NEMA LD3-2005 quality standards with Antivirus, Antibacterial and Antifungal properties (conforming to ISO 21702:2019, JIS Z2801:2010 and ASTM G21-2015 standards respectively) to fulfil the applicable requirements of indoor air quality certifications for Greenguard-Gold standards. This also includes providing and fixing in position necessary hardware made out of Nylon Polyamide grade 6 & Aluminium alloy grade 6063-T6 powder coated finish in black and other available color hardwares as per manufacturer’s specifications & Architects instructions like (1) Self closing hinges in Nylon Polyamide grade 6 in gloss finish in available colors (2) Soft closing thumb turn lock made in nylon polyamide grade 6 in gloss finish in available colors (3) Single Coat hook in nylon polyamide grade 6 in gloss finish,available in similar available colors (4) U & F- profiles in Aluminium alloy grade 6063-T6 with powder coating in available colors (5) Nylon polyamide grade 6 Adjustable Leg (6) Top rail along with Nylon Polyamide grade 6 with end cap is a Round D shaped extrusion made of Aluminium alloy grade 6063-T6 with Powder Coating in available colors, (7) Rubber, (8) Screws & wall Plugs ( SS- 316 ). The top fitting should consist of Matt finish aluminium alloy grade 6063-T6 in avilable colors , which will get fixed on pilasters with SS Screws, All screws will of 316 Grade in stainless steel . All pilasters are supported by grade- 6 Nylon Polyamide Thermoplastic palm design pedestal footing with non corrosive steel inserts. The base anchored to the floor with grade 316 satin finish stainless steel screws with push fit capping at a clearance height of 150mm. complete as per specification an direction of the Engineer in charge
306Toilet Cubicle with standard dimension of 1995mm Height x 1000mm Width x 1500mm Depth, which includes 600mm door size width).
307Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor
308Ground Floor
309Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C.
310Ground Floor
311First Floor
312Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.
313Ground Floor
314First Floor
315Providing and laying Vitrified floor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights.
316Ground Floor
317First Floor
318Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600x 300 size.
319Ground Floor
320First Floor
321Supplying all materials, labour, T&P and fixing granite tiles in top skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge
322Ground Floor
323First Floor
324Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter complete in all respect as per specification and direction of the Engineer in charge
325Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
326EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.
327110mm dia U-PVC Alround Concrete.
328160mm dia U-PVC Alround Concrete.
329Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm
330Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm .
331Addl depth of 0.15m upto 0.90m
332R.C.P.C.Manhole Cover
333Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
334R.C.P.C.Manhole Cover
335Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit.
336FRP STP 15 KLD
337Supply, installation, testing & commissioning of 1 Nos Stainless Steel Perforated,Corrugated Bar Screen with suitable lifting arrangement (size 500 mm x 1000 mm) etc all complete as per approved specification and direction of the Engineer in charge.
338Supplying, installing, testing and commissioning, consisting fine bubble diffuser along with membrane of SILICON membranes, PVC support pipe(10 ksc pressure rating),PVC fitting, nylon rope braided hose with all accessories to make it retrievable & to provide clog-free oxygen for Aeration Tanks. etc all complete as per approved specification and direction of the Engineer in charge.
339Supply, installation, testing and commissioning of on line electronic sodium hypo chloride dosing sytem dosing pump and Tank etc., The unit shall comprise of the following: Capacity of the dosing Pump - 0-4 LPH Pressure- 4 Kg/cm2 Stroke per minute-55 Dosing Tank- 100 Ltr, Make- E-DOSE/PRO AQUA/KANAKDHARA etc all complete as per approved specification and direction of the Engineer in charge.
340Supply, Installation, Testing Commisioning of pipes & Valves with fittings such as tees, crosses, plugs, sockets, elbows, unions, flanges, sleeve pieces, check nuts etc for the entire STP Plant. Inter connecting pipe works with valves for air line- JINDAL/TATA Inter connecting pipe works with valves for water line- UPC/UPVC- SUPREME/FINOLEX etc all complete as per approved specification and direction of the Engineer in charge.Ground Floor
341Supply, Installation , Testing Commisioning of of MCC Panel (motor control center) to accommodate all the drive units with cabling,glanding within the STP Compartmental, design Indoor wall mounted type with top entry for cable the internal components either Siemen / GE Shall be provided with 1 No. Energy meter. along with cable & Cable tray To receive, control and distribute electrical power at 440 V, 50 Hz, MCC is to be manufactured/assembled as per the latest ISI specification, Indian Electricity Rules, Including special requirements of concerned state electricity inspectorate.The switch board shall be fabricated out of 14 SWG sheet steel and shall be un cubical design.MCC of suitable rating to take care of full load of the sewage treatment plant including all motors and lighting.MCC shall be provided with the following feeders: Incoming Feeder :electronic digital energy meter suitable for full load Voltmeter with selector switch protected through HRC fuses ranging from 0 - 500 V. LEDtype indication for 3 phases, protected through HRC etc all complete as per approved specification and direction of the Engineer in charge.
342Commsioning of STP with consumables,Tools & tackles and manpower for 15 days.Test reports for both inlet and outlet in approved lab etc all complete as per approved specification and direction of the Engineer in charge.Ground Floor
343Supply, installation, testing & commissioning of non clogging sludge transfer pumps with all accessories, motor of required capacity, Pressure gauge on delivery line with control the level of EQT automatically. Pumps shall have following duty: Capcity - 1.0m3/Hr. Head - 10 mwc Motor HP/RPM- 0.5/2900 Make- KIRLOSKAR/LUBI/CG etc all complete as per approved specification and direction of the Engineer in charge.Quantity- 2 Nos (1w + 1 S)Ground Floor
344Supplying, installing, testing and commissioning Consisting of 2 Nos. of centrifugal filter feed pumps (one working + one standby) to feed the treated sewage Water from clarified water tank to Multigrade Filter & Activated Carbon Filter . Flow -4.5 m3/Hr. Head - 30 Mtr. Motor HP/RPM- 1.0/2900 Make- KIRLOSKAR/LUBI/WILOMOC- CI Quantity- 2 Nos etc all complete as per approved specification and direction of the Engineer in charge.
345Supplying, installing, testing and commissioning of FRP composite Multigrade Filter with Multiport vales. Filter shall be suitable for working pressure of 3.5 kg / cm2 and shall include standard fittings like pressure gauges, sampling cock, etc. Flow Rate- 4.5m3/Hr. Dia x HoS ( mm )- MGF 18 x 65 MOC- FRP COMPOSITE VESSEL etc all complete as per approved specification and direction of the Engineer in charge.Make- TATA/AQUANOMICS/STARLITE
346Supplying, installing, testing and commissioning of FRP composite Activated Carbon Filter with five Multiport vales . Filter shall be suitable for working pressure of 3.5 kg / cm2 and shall include standard fittings like pressure gauges, sampling cock, etc all complete as per approved specification and direction of the Engineer in charge.. Flow Rate-4.5m3/Hr. Dia x HoS ( mm)- ACF 18 x 65 MOC- FRP COMPOSITE VESSEL Make- PENTAIR/AQUANOMICS/TATA
347Design Supply, installation, testing and commissioning of MBBR media, and Tube settler to be provided in the areation tank and settling tank etc all complete as per approved specification and direction of the Engineer in charge. MOC of MBBR Media - Poly Propylene as per approved specification and direction of the Engineer in charge. Make-COOLDECK/MM AQUA Quanity of MBBR Media - 2.0 m3 Tube settler - 3.0 m3Ground Floor
348Design supply instalaltion testing and Commissioning of 1 Lot of Bacteria for Comissioning of the STP as per approved specification and direction of the Engineer in charge.
349Supply, installation, testing and commissioning of on line electronic Poly dosing sytem dosing pump and Tank etc., The unit shall comprise of the following: Capacity of the dosing Pump - 0-4 LPH Pressure- 4 Kg/cm2 Stroke per minute-55 Dosing Tank- 100 Ltr, as per approved specification and direction of the Engineer in charge. Make- E-DOSE/PRO AQUA/KANAKDHARA
350Supplying, installing, testing and commissioning of Twin 15 KLD FRP Packaged STP Dia -2.2 mtr Length 7.0 mtr Make -Aquatech Solution/Sintex /Arbindasol as per approved specification and direction of the Engineer in charge
351\\"Supplying, installing, testing and commissioning of Twin Lobe design type air blower complete with motors, pulleys, one piece CI casing and side plates, silencer, base plate, Anti-friction bearings, Rotary oil sealings having horizontal configuration.with electric motor \\"Capacity of Blower- 68 m3/Hr. Head- 0.4 kg/cm2 Motor HP/RPM- 3/1500 as per approved specification and direction of the Engineer in charge. Make- A1/AKASH/AIRVAK MOC- CI AirRequired for reactor tank- 53Nm3/Hr. Air Required for Equalization tank- 15Nm3/Hr.Ground Floor
352Erection and commissioning of the 15 KLD Underground Plant
353\\"Supplying, installing, testing and commissioning of 50KL Underground FRP Tank , Tank Dimension Length 10 mtr, length dia 2.2, Tank Manhole Dia -550mm, Height -150 mm, Moc -FRP, Tank Inlet outlet Dia-700mm Moc-FRP, Air Vent Socket Dia:150 mm Moc: UPVC, Tank Rib Details 1-Rib width -90mm, 2- Rib Width-40 mm, 3- Rib to Rib Distance -400 mm, Tank Leg Details -Leg width -100 mm Height 500 mm, Height: 500 mm, Tank MOC Fiber Glass Reinforced Polymer, Resign Grade Isophthalic Polyster Resin,Tank Backfilling Matterial - sand /up to tank manhole height with balck stone as per approved specification and direction of the Engineer in charge.
354Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submerisble electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge1.50 single phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.P.M with outlet dia of 32mm
355Supplying all materials, labour, T&P and providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge.
356ELECTRICAL
357Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard/Gloster with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)
358GROUP-A
359Group B
360Group C
361Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
362Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
363Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)(flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
364Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
365Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover(falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
366Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard/Gloster in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
367Circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard/Gloster in MS metallic conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia metallic MS conduit (2X1.5+1X1.5)
368Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard/Gloster in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
369Circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard/Gloster in MS metallic conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia metallic MS conduit (2X2.5+1X1.5)
370Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard /Gloster in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
371Circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard/Gloster in MS metallic conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia metallic MS conduit (2X4+1X1.5)
372Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard /Gloster in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
373Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard /Gloster in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
374Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC /Precision/ Norpack/ Kinjal.(Only for data, telephone, CCTV)
37520 MM
37625 MM
377Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
3784 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years as per direction of Engg.-in-Charge
379Supplying and fixing 16Amps 4P 415 volts, MCB,C series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years
380Supplying and fixing 16 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
381Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year.
382Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
383Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 year
384Fittings & Fixtures
385SITC of 15W LED track-mounted adjustable spotlight with adapter suitable for installation on track system, having aluminium alloy body with extruded aluminium for superior thermal management, high-performance reflector for precise spot lighting with beam angle(as per final approved design), die-cast aluminium bracket allowing 360° rotation and 90° tilt, clear polycarbonate for glare-free uniform light distribution, IP20 protection, epoxy polyester powder coated finish (white/black), high-efficiency LED module (CRI ≥90, minimum 50,000 hours life), available in 2700K/3000K/4000K/6500K, provided with built-in constant current driver (efficiency >85%, power factor >0.95, THD <10%, surge protection 3kV), suitable for 240V, 50Hz AC supply, two-circuit track connector for easy installation and maintenance, complete with all track light accessories, wiring, installation, testing and commissioning, CE certified as per direction of Engg.-in-Charge. Make- Jaquar/ERCO/LT/K-Lite/Philips
386SITC of 15W LED frame track-mounted adjustable spotlight with adapter suitable for installation on track system, having aluminium alloy body with extruded aluminium for superior thermal management, high-performance reflector for precise spot lighting with beam angle(as per final approved design), die-cast aluminium bracket allowing 360° rotation and 90° tilt, clear polycarbonate for glare-free uniform light distribution, IP20 protection, epoxy polyester powder coated finish (white/black), high-efficiency LED module (CRI ≥90, minimum 50,000 hours life), available in 2700K/3000K/4000K/6500K, provided with built-in constant current driver (efficiency >85%, power factor >0.95, THD <10%, surge protection 3kV), suitable for 240V, 50Hz AC supply, two-circuit track connector for easy installation and maintenance, complete with all track light accessories, wiring, installation, testing and commissioning, CE certified as per direction of Engg.-in-Charge. Make- Jaquar/ERCO/LT/K-Lite/Philips
387Supply and fixing of 2 metre surface-mounted magnetic track (single/dual circuit as specified), black anodised/powder-coated aluminium extrusion, complete with mounting clips, end feed connector and all accessories required for surface installation, compatible with magnetic track light fittings, as required and as per direction of Engineer-in-Charge. The rate is inclusive of track cover strip for surface/suspended colt track system, black powder-coated aluminium, snap-fit type for concealing wiring/busbar, complete with all accessories as per direction of Engineer-in-Charge.Make- Jaquar/ERCO/LT/K-Lite/Philips
388Supply and fixing of 1 metre surface-mounted magnetic track (single/dual circuit as specified), black anodised/powder-coated aluminium extrusion, complete with mounting clips, end feed connector and all accessories required for surface installation, compatible with magnetic track light fittings, as required and as per direction of Engineer-in-Charge. The rate is inclusive of track cover strip for surface/suspended colt track system, black powder-coated aluminium, snap-fit type for concealing wiring/busbar, complete with all accessories as per direction of Engineer-in-Charge.Make- Jaquar/ERCO/LT/K-Lite/Philips
389Supply, installation, testing & commissioning of 200W constant-voltage 48V DC driver/power supply unit for magnetic track lighting system, over-load and short-circuit protected, complete with all wiring terminations and mounting accessories, suitable for concealed/surface installation as required and as per direction of Engineer-in-Charge. Make- Jaquar/ERCO/LT/K-Lite/Philips
390SITC of 3w, floor recess mounted compact in-ground luminaire. Asymmetrical light distribution. Polycarbonate optical lens for higher efficiency, lower optical losses with optimum glare suppression. Pressure die-cast aluminium housing, Stainless steel top ring (grade 316) with toughened glass. Polypropylene Black installation housing for preparing the recess opening in ground. Single cable entrance via grey M10 cable gland. All external screws are made of stainless steel. Clear silicone gasket. Protection class IP67. Mechanical resistance IK08. Available colour temperature 2700K / 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. LED module with expected service life of at least 50,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply as per direction of Engineer-in-Charge. CE & BIS Certified. Make- Jaquar/ERCO/LT/K-Lite/Philips
391SITC of high quality aluminium frame with Multi Color Neon Flexible light, Protection Rating : IP65, Mounting Structure : Adjustable wall mount aluminium profile for fixing the lights. Power consumption : 12W, CCT : RGB/RGBW, (as per the design approval) Beam Angle : 120º, Control : DmX512 Channel : 4 CH, Power Input : DC 24V with external driver, Surge Protection : Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Fixture will be suitable to operate in a temperature range of 0°C to 50°C , LED life time should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. as per direction of Engineer-in-Charge.Make- Jaquar/ERCO/LT/K-Lite/Philips
392Supply, installation, testing & commissioning of constant-voltage LED driver for neon flex strip lighting system, grey powder-coated metal enclosure, overload and short-circuit protected, complete with all wiring terminations and mounting accessories as required as per direction of Engineer-in-Charge. Make- Jaquar/ERCO/LT/K-Lite/Philips
393SITC of 30W, suspended 4 feet 50mm wide linear, IP20, SMD LED luminaire with system efficacy of >115 lumen/watt and system lumen output of >3450 lumen, operating in an ambient temperature of 0⁰C to 45⁰C. Operating at 50Hz frequency, luminaire shall have extruded aluminium housing in white with high efficiency translucence diffuser and must have provision for end to end seamless connectivity. LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. The LED shall comply with L70 life of 50000 burning hours tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80, with MacAdam CCT binning ≤5. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 140V to 300V (nominal rated voltage – 240V) with 3KV internal surge protection, Power factor of minimum 0.95, driver efficacy of minimum 85% and total harmonic distortion (THD) of less than or equal to 10% should be integral to the luminaire (Make:Jaquar/ERCO/LT/K-Lite/Philips).The luminaire should be Replacement Warranty will be 2 years
394Supplying and fixing of Energy efficient surface mounted cylindrical shape 15 W LED spot luminaire of dimension of consists of white powder coated , die-cast Aluminium housing with high quality opal diffuser for glare-free uniform lighting distribution, CRI not less than 80,CCT of 3000/4000/6500 K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , The fixture design should be with flicker free operations ripple <5%, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make:Jaquar/ERCO/LT/K-Lite/Philips).The luminaire should be Replacement Warranty will be 2 years
395Supplying and fixing of Energy efficient surface mounted cylindrical shape 5 W LED spot luminaire of dimension of consists of white powder coated , die-cast Aluminium housing with high quality opal diffuser for glare-free uniform lighting distribution, CRI not less than 80,CCT of 3000/4000/6500 K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , The fixture design should be with flicker free operations ripple <5%, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make:Jaquar/ERCO/LT/K-Lite/Philips).The luminaire should be Replacement Warranty will be 2 years
396Supplying and fixing of Energy efficient surface mounted cylindrical shape 10 W LED spot luminaire of dimension of consists of white powder coated , die-cast Aluminium housing with high quality opal diffuser for glare-free uniform lighting distribution, CRI not less than 80,CCT of 3000/4000/6500 K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , The fixture design should be with flicker free operations ripple <5%, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make:Jaquar/ERCO/LT/K-Lite/Philips).The luminaire should be Replacement Warranty will be 2 years
397SITC of spike mounted 8w, compact spot light designed to provide directional light.Beam angle 15° / 25° / 40°( as per approved final design). Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK07. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 6500K, Colour rendering index (CRI)>80. LED module with expected service life of at least 50,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.95, THD <10%, Surge protection 4KV. CE & BIS Certified as per the direction of Engineer-in-charge.(Make:Jaquar/ERCO/LT/K-Lite/Philips)
398Supplying and fixing of Energy efficient surface mounted cylindrical shape downlighter 35 W LED luminaire consists of white powder coated Aluminium housing with high quality opal diffuser for glare-free uniform lighting distribution, CRI not less than 80,CCT of 3000/4000/6500 K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , The fixture design should be with flicker free operations ripple <5%, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make:Jaquar/ERCO/LT/K-Lite/Philips).The luminaire should be Replacement Warranty will be 2 years
399Supply, installation, testing & commissioning of decorative surface-mounted chandelier luminaire, gold-finish metal/acrylic frame, CCT 3000K, LED source with driver, of design and dimensions as approved by client/Engineer-in-Charge, complete with suspension/fixing hardware as required. (Make:Jaquar(DMO-GLD-AS40510X2/ERCO/LT/K-Lite/Philips)
400Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make:Jaquar/ERCO/LT/K-Lite/Philips).The luminaire should be Replacement Warranty will be 2 years
401SITC of 30W LED decorative pendant lighting fixture with extruded aluminium housing and die-cast endcaps, high-efficiency LED (CRI >90) with colour temperature options 2700K/3000K/4000K/5700K, polycarbonate hexa-cell diffuser (matte black) for low glare (UGR <16) and uniform light distribution, fixed optical system with 50° tilt (as per the approved final design) beam angle, integral constant current driver (efficiency >85%, power factor >0.90, THD <10%, surge protection 4–6kV), suitable for 220–240V AC, 50Hz supply, operating temperature -15°C to +50°C, IP44 protection, available in standard finishes (RAL 9004/9016/9007), complete with suspension accessories, wiring, installation, testing and commissioning as per direction of Engg.-in-Charge (Make:Jaquar/ERCO/LT/K-Lite/Philips).The luminaire should be Replacement Warranty will be 2 years
402Supply, installation, testing & commissioning of 36W LED hanging/suspended drum profile luminaire, white finish, CCT 3000K, extruded aluminium drum housing with diffuser, complete with driver, suspension kit and all accessories as required and as per direction of Engineer-in-Charge. (Make:Jaquar( PRDH36WWWD02FTED)/ ERCO/LT/K-Lite/Philips). The luminaire should be Replacement Warranty will be 2 years.
403Supply, installation, testing & commissioning of decorative hanging/suspended pendant luminaire, black-finish metal frame with mesh/lattice shade, CCT 3000K, LED source with driver, complete with suspension kit and all fixing accessories, of design as approved by client/Engineer-in-Charge. Make- Jaquar( DPN-BLK-SL6001MESH)/ ERCO/LT/K-Lite/Philips.
404Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
405Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) .
406S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
407PANEL DISTRUBUTION
408S/I/T&Commissioning of LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 80X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with with 125A 4P MCCB, 25Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) Make of SPD -LEGRAND / Siemens/ Schneider/ABB/OBO/Dehn/ABB. Mandatory provision of cable alley is to be given. ON/OFF/TRIP indication shall be given for all the feeders.
409In comer 1- 01 no 1250A 4P ACB 50kA with EDO TYPE ACB Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) ( Make-LEGRAND-DMX3 / Siemens-3WT Model/ Schneider- Materpact NW/ ABB- Emax2),Incomer 2- 01 no 1000A 4P ACB 50kA with EDO TYPE ACB Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) ( Make-LEGRAND-DMX3 / Siemens-3WT Model/ Schneider- Materpact NW/ ABB- Emax2)Buscoupler-01 no 1000A 4P ACB 50kA with EDO TYPE ACB Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) ( Make-LEGRAND-DMX3 / Siemens-3WT Model/ Schneider- Materpact NW/ ABB- Emax2) Busbar- 04 numbers of 1500Amps Aluminium bus bar Electrolytic Aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.OUTGOING: 2 NOS. 320A 4P MCCB 36kA LSIG microprocessor based, Ics=100%Icu, 4 NOS. 250A 4P MCCB 36kA LSIG microprocessor based, Ics=100%Icu, 4 nos 63A 4P MCCB 25kA MCCB, adjustable thermal based, Ics=100%Icu, 12 nos 125A 4P MCCB 25kA with TMR based release with adjustable overload ,Icu=100%Ics Make-LEGRAND-DPX3/ Siemens-3VA/ Schneider- CVS/ ABB FormulaInstrument- (i) phase indicating lamp with toggle switch & HRC fuse in all the incomers and buscoupler.All the feeders shall have ON/OFF/TRIP indication .All the outgoing feeders shall have digital ammeter with suitable rating of Class 1 CT as per the feeder rating.(ABB/Schneider/Siemens/Legrand)(iii) All the incoming feeders shall have digital multifunction meter(V+A+F+KwH+KVAR+KVAH+THD
410FLOOR LIGHT and POWER PANEL:(GF,1F,) S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical floor panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer.Incomer:125A 4P MCCB 25kA with TMR based release with adjustable overload ,Icu=100%Ics Make-LEGRAND-DPX3/ Siemens-3VA/ Schneider- CVS/ ABB FormulaBus bar: 4 nos. 200 A Aluminum Busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing : 5 Nos 40-63A 4P MCB, C series. (10 KA) , Complete duly factory wired as per SLD and panel should have proper earth by suitable rated Aluminium flat earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.All the feeders shall have digital ammeter with suitable rating of Class 1 CT as per the feeder rating.MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB formulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard/Schneider-Acti-9/ABB SB200
411FLOOR UPS PANEL : S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical panel (for EMERGENCY circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. In commer- 01 no 63 A 4P MCCB 16kA ,adjustable thermal, Ics=100%Icu with on/off trip indication Light load for each floor. Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.Out going- 6numbers of 16-32A 4P MCB 10kA,C series,6numbers of 32A DP MCB 10kA,C series Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)..(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-100)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 100/5A 3 nos class 1 type(Make-Schneider/Siemens/ABB/Legrand)
412HVAC OUTDOOR PANEL:S/I/T&Commissioning of CPRI tested LT outdoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. BUILDING HVAC as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer.. 40x10mm Separate Aluminium Earth bus bar should be installed.In commer- 01 number of 320A 4P MCCB,36 Ka with under voltage,over voltage ,current,earth fault protection Icu=100%Ics with adjustable Thermal Magnetic Release( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA). Busbar- 04 numbers of 500Amps Aluminum busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 63A 4P RCBO,300MA 8 NOS FOR OUT DOOR UNIT ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200) ,25A 4P RCBO,300MA 3 NOS FOR OUT DOOR UNIT, 32A 4P RCBO,300MA 3 NOS FOR OUT DOOR UNIT ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(Legrand/ Legrand /abb/Siemens/Schneider))
413SITC of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder coated paint is designed as G.A drawing. (FOR LIFT)as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. 63amp panel board having 63A Amp 16KA 4P MCCB TMR based release with adjustable overload ,Icu=100%Ics as incommer, 100 amp electrolyte Aluminium bus ba-1 Set, 63A Amp 4P RCCB 30mA- 1 No,25A Amp DP RCCB 30mA- 2 No,6-32A DP MCB 10ka, c series -2 No as Outgoing with ampere meter, voltmeter, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make of mccb :-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA) Make of MCB-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(Lift Panel)
414UPS EMERGENCY PANEL:S/I/T&Commissioning of LT indoor CPRI tested floor mounted cubical type electrical UPS panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Incomer:02 no 63 A 4P MCCB 25kA ,adjustable thermal, Ics=100%Icu with on/off trip indication Light load for each floor. Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Bus coupler- 01 no 63 A 4P MCCB 25kA ,adjustable thermal, Ics=100%Icu Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Bus bar: 4 nos. 150 A Copper Busbar duly sleeved Instruments: 1 set. LED type phase indicating lamps with control fuses Outgoing : 03 no 63 A 4P MCCB 16kA ,adjustable thermal, Ics=100%Icu Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Complete duly factory wired as per SLD and panel should have proper earth by suitable rated Aluminium flat earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge..MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula ,Make of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200
415Supply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC / VERTIV) LOAD OF emergency) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.
416LAYING
417Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
418Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
419Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
420Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
421Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
422CABLE
423Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
4243.5 core x300 sq mm Aluminium armoured Cable.(FOR MAIN PANEL )
4253.5 core x 50 sq mm Aluminium armoured Cable.(FOR FLOOR PANEL)
4263.5 core x 25 sq mm Aluminium armoured Cable.(FOR LIFT & STREET PANEL)
4273 core 2.5 sqmm control COPPER armoured Cable
4284 core x 16 sq mm Aluminium armoured Cable.
429Supply and laying of 5 core x 10 sq mm Copper armoured XLPE cable. Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster
430Supply and laying of 5 core x 6 sq mm Copper armoured XLPE cable. Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster
431Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.
4323.5 core x 300 sq mm brass double compression gland and aluminium lugs
4333.5 core x 50 sq mm brass double compression gland and aluminium lugs
4343.5 core x 25 sq mm brass double compression gland and aluminium lugs
4354 core x 16 sq mm brass double compression gland and aluminium lugs
436Earthing:
437Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
438Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
439Supplying of following Materials.
440Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room as per direction of Engineer-in-charge.
441Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room as per direction of Engineer-in-charge.
442Supply installation of high-voltage insulating mat has a thickness of 3.0 mm, rated for maximum use voltage of 33 kV. It withstands an AC proof voltage of 36 kV and an AC dielectric strength of 65 kV, with maximum leakage current limited to 10 mA. Minimum insulation resistance (5000V megger) is 1,00,000 MΩ. Tensile strength is minimum 15 N/mm², with 250% minimum elongation. After 168 hrs aging at 70±1°C, retention is minimum 75% (tensile & elongation); after 48 hrs immersion in acid/alkali/diesel/oil, retention is minimum 80%. The mat offers low-temperature resistance and flame retardance, made of synthetic elastomer, conforming to IS 15652. complete as per direction of Eng-in-charge.(Size-10mx1m) make : mandelia insulation and transmission co./Duratuf/Raychem/Vardhman
443Danger Board.
444Lighting Protection
445Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
446Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per EIC 62561-6. Make-OBO/Dehn/ABB
447Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
448Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB
449Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB
450Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
451Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB
452Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB
453Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB
454Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB
455Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
456Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB
457Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
458Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB
459Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
460Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB
461Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB
462Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
463Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB
464Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
465Supply delivery ,installation andcommissioning of LED Sign Board as per below specification of Box type Display Matter:-1-SAND ART PURI (English Letter Red Color) Letter Height 36 Inch.2- (Odiya Letter Red Color) Letter Height 36 Inch3-Government of Odisha Logo (36X36 Inch) ACP Sheet:- Aluminum composite panel sheet(ACP) Outdoor type 3 mm (Viva, Alomax, Imperia Décor, Citi Bond ) Supporting of English Letter.Plastics Sheet: - 3mm Plastics Sheet (Yellow, Red) Color & Raising of 2.5 inch.(Gray) (Acast)L.E.D :- 0.3 to 1.5 Watts (Yellow, Red) Color (Samsung, GE, Osaram, Philips, LG) Power Supply: - SMPS (Switch mode Power Supply), RPS (Regulate Power Supply).In put Voltage 160 to 230 A.C./ Out put Voltage 12/24 Volts D.C. (Samsung, GE, Osaram, Philipes, LG). The panel should be supplied with astronomical timer and contactor for auto ON/OFF . The panel should be supplied with overvoltage and undervoltage relay with 20 kA TYPE 2 SPD.The panel should be outdoor type. The letter structure to be installed on the top of the building. It shall withstand 200 km/hr wind velocity, MS ANGLE with primer and paint as per need for sustainable fixture 2 inch Ms pipe fastened with concerte. The cost is inclusive of all the structures, LED light, timer control panel and all other accessories. Make-Cosign/Sign media
466Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
467Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
468Supplying,fixing of FLOOR RACE WAY GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE-Legrand/ Profab/OBO/Neidax .(With all accessories,bend,cover,supporter) as required as per direction of Engg.-in-Charge.
469Supplying,fixing of 8 module under- FLOOR outlet box IP20, size not less than 308mmx308mm as required as per direction of Engg.-in-Charge.MAKE- Profab/OBO/Neidax/Legrand
47015 PASSENGER LIFT
471Supply,Installation, Testing & Commissioning of of 15 Passenger lift gearless with Machine room less Capacity 1020 kg , G+1 Floors (Shaft size should not be less than-2400mm(Left to right)x2800mm(Front to back)) with ACVVVF drive/Control for constant load of 1020 kg ARD >=1.25 MPS SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .All SS materials shall be of grade SS-304 with thickness not less than 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons (v) provision of flat cat-6 cable for cctv with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room less,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. Make:OTIS/Mitsubishi/Johnson/Schindler
472HVAC WORK
473Supply,Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s) microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at 49°C ambient temperature without tripping. The unit shall be suitable to work on 380-415 V, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads.The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, automatic refrigerant charging,blue fin treated condensor coil for corrosion resistant, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. .The unit should be treated with heavy anti-corrosion coating.The OEM should provide UL/NABL anti-corrosion certificate. The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.ISEER should be greater than equal to 7.4 for cooling capacity less than 40kWr, ISEER should be greater than equal to 7.5 for cooling capacity more than equal to 40kWr and less than 70kWr and ISEER should be greater than equal to 7.6 for cooling capacity more than equal to 70kWr.The deration chart of outdoor from factory head should be submitted before procurement.Make: Mitshubishi(MultiCity Y Series)/O-GENERAL(VC-V)/Daikin(Alpha)
47410 HP
47514 HP
47616 HP
47720 HP
478SITC of ODU Connecting Kit with other accessories as per the direction of Engineer-in-charge. Make: Mitshubishi/O-GENERAL/Daikin
479SITC of AHU connecting kit with other accessories as per the direction of Engineer-in-charge. Make: Mitshubishi/O-GENERAL/Daikin
480Supply, Installation,Testing and Commissioning of following minimu capacity 4-way/ VRV Cassette Type Indoor ceiling mounted unit equipped with cord less remotes & refnets , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. The cost is inclusive of Refnet joints. Make: Mitshubishi/O-GENERAL/Daikin
481CASSETTE TYPE INDOOR UNITS
4821.5 TR
4834.0 TR
4844.5 TR
485The performance of air handling units should be tested in a Eurovent-accredited laboratory.The AHU technical data sheet shall be submitted for coil/fan performance from certified software output individual component selection not be considered.One AHU for the project will be factory tested for air performance CFM / Static / Power / Motor KW / Sound/Vibration, prior to dispatch.Air handling unit shall be selected for the lowest operating noise level i.e. not exceeding 65 dbA @ 1.5 metre distance from the equipment. Mechanical Characteristics as per EN 1886: a. Casing Strength Classification: D1 b. Casing Air Leakage: L1 c. Filter Bypass Leakage: F9 d. Thermal Transmittance: T2 e. Thermal Bridging Factor: TB2 Air Handling Unit Performance as per EN 13053
486Supply, installation, testing ,assembly at site and commissioning of outdoor type DOUBLE SKIN FLOOR MOUNTED AHU of horizontal / vertical arrangement, draw through type with sectionalised construction suitable to be assembled at site as per EN 1886 Construction Details: Double-skinned panels shall be 50 ± 2 mm thick with thermal break construction and made of galvanized steel skins, pressure injected with PU foam insulation having density 40 kg/m3 with a K factor not exceeding 0.022 Watt/Mc internal structural framework with high speed steel screws. Outer sheet of panels shall be made of pre-painted, of 0.8 mm thick, and inner sheet of 0.6 mm G.I. Sheet.The entire framework shall be assembled in modules & mounted on a galvanized steel (depending on size) channel base as per manufacturer’s recommendation. All panels to have doors except for the coil section & to be openable on the outside.Drain pand shall be strictly inside the AHU casing PU panel and not to be exposed to environment.Mixing Section: The AHU shall be provided with mixing chamber section. The mixing box shall have a manually operated return air and fresh air damper of Low leakage Aerofoil design, with concealed (Nylon gears / linkage type) Anodized Aluminum construction in the mouth piecePre Filter Section:The AHU shall be provided with synthetic (non woven) filter section with 50 mm thick filters fitted on aluminium frame capable of filtering 90% down to 10 micron (MERV-8) washable type filters as per EN 779Note: The AHUs should be supplied with a pair of pre-commissioning filters which will be replaced by the actual filters during commissioningFine Filter Section:The AHU shall be provided Fine filter section containing Synthetic 300 mm Bag, class F7, equivalent to EU7 (MERV 13) of ASHRAE 52.2 1999 .The efficiency of the filters shall be 95% down to particle size of 5 microns as per EN 779. Differential pressure measuring port to check filter efficiency all complete as requiredCoil Section: Cooling coil of 8 row copper tube. The coil shall be EUOROVENT certified as per EN 1216. The header shall be made of copper and the end caps of MS. The tube shall be of copper and shall be 0.4 mm thick and 12.5 mm diameter. The fins shall be of aluminium of 0.11 mm thickness with spacing of 10-11 FPI and shall be coated with anticorrosive hydrophilic blue colour coating. The coil shall be minimum 8 row deep or shall be designed as per the load requirement and the area shall be selected for a maximum face velocity of 2.5 m/s. (Selection sheets need to be provided for approval)Fan Section: Eurovent certified direct driven aerofoil design blade plug fans of high efficiency as per EN 5801. The fan shall be selected for an outlet velocity of not more than 9 m/s. The fan should be selected to ensure that it operates within the optimum range when the speed of fan shalll be 40% to 150% of motor RPM. For capacities till 9000 cfm single fan can be used. For capacities between 9000 cfm to 14000 cfm single / two fans can be used. However for capacities above 14000 cfm, multiple fans to be used.Motor Section: The AHU shall be provided with AC motors of high efficiency. Motor shall be 415±10% volts, single / three phase as suiting the airflow range, TEFC, with class F insulation with IP 55 protection for AC Motors. Motors shall be specially designed for quiet operation. The motor should be variable speed type & driven by VFD for AC motors.Motor Winding shall be VPI coated.Drain Assembly: 20G SS 304 drain pan to be installed strictly inside the AHU. Drain pan installation outside the PU panel casing is not allowed. Air moving capacity, cooling capacity and external static pressure ESP) excluding pressure drop across filter, coil and fan sections shall be according to the enclosed AHU details.The rate is inclusive of VFD panel.IP 20 rated VFD to be placed inside the starter panel with IP-55 enclosure.Each VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption.At the time of odering ahu total pressure loss as per friction method and ahu coil selection should be submitted for approval.Make- VTS/Trane/Systemair
48748TR 15000 CFM 8RD, ESP-110MM, FM AHU with Pre and fine filter.
488SITC of 24ft length x24ft width x 15ft height GI shed for AHU as per direction of Engineer-in-charge.
489Supply, Installation,Testing and Commissioning of following minimum capacity Ductable Type Treated Fresh Air unit equipped with corded remote & refnets, synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. Make: Mitshubishi/O-GENERAL/Daikin
4901000 CFM TFA type IDU
4911130 CFM TFA type IDU
492Mid/HIGHSTATIC UNIT
493SITC of Imported type Indoor units suitable for operation at a power source 1 Phase, 220V, 50Hz as well as other accessories as required for smooth operation of the system of the following capacities along with Panel & cordless remotes for each IDUs of below Capacity make : Mitshubishi/O-GENERAL/Daikin
494DUCTABLE TYPE INDOOR UNIT
4952.0 TR - Mid Static Ductable (GUEST ROOM)
4968 TR - Hi Static Ductable ( RECEPTION,EXTENTED SAND PARK )
497Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular Class O fire rated insulation conforming to BS476 Part6 and part 7 between each set of indoor & outdoor units . The pipe dia upto 25 shall be soft seamless & above 25mm dia shall be hard seamless . All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in GI. cable tray etc. as reqd as per direction of Engineer-in-charge. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow
49841.3 mm with 1.43 mm thick
49934.9 mm with 1.21 mm thick
50028.6 mm with 1.00 mm thick
50122.2 mm with 0.8 mm thick
50219.1 mm with 0.8 mm thick
50315.9 mm with 1.00 mm thick
50412.7 mm with 0.8 mm thick
5059.5 mm with 0.8 mm thick
506Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular Class O fire rated insulation conforming to BS476 Part6 and part 7 between each set of indoor & outdoor units . All external piping(which are exposed to external environment such as terrace etc.) shall be provided with factory laminated GC Cloth & then shall run in unperporated hot dip galvanized GI. cable tray with cover etc. as reqd as per direction of Engineer-in-charge. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow
50741.3 mm with 1.43 mm thick
50819.1 mm with 0.8 mm thick
509SITC of Condensate Drain Pipe :
510Providing & fixing of PVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness Class O of closed cell nitrile rubber/XLPE as per direction of Engineer-in-charge & specifications enclosed as reqd.
51150 mm
51240 mm
51332 mm
514Supply, Manufacturing, fixing,testing and commisioning of Factory Made double wall Flat Oval Spiral Duct with 19 mm Plain Nitrile rubber insulation of class 1 Sandwich in the both layer .The cost of Insulation shall be included in the ducting Cost with adhasive and all necessary accessores. The Inner layer of the Duct shall be of 24 G only Outer layer shall be as per Ducting SMACNA standards of Flat Ovel Duct . The Cost of Hanging arrangemnet shall be included as per OEM standards and also the GI Hook or clam shall be used . all nut Bolt shall be of Hot Dipped Galvanized GI nut with washer shall be Used . The Cost of Threaded Rod and Necessary fastner shall be included in the Cost of Ducting Its Self .The Duct Shall be Joint with the POP up rivit or Self Fasting GI screw with Sealent . the Length of Duct Shall be either 4 , 10 or 12 Feet . Branch Peices can be as per the Site Design Requirment . The Duct Collar Can be of Single layer with Insulation to acomodate the Air Distribution Product Make:TATA/SAIL/JINDAL
51522 GAUGE (0.80 mm thickness)
51624 GAUGE (0.63 mm thickness)
517Supply & Fixing of Cooled Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)24G (0.63 mm)
51822G (0.8mm)
519Supply,installation,testing and commissioning of 0.6 mm Aluminum cladding on Outdoor Ducts. Make-Hindalco/Balco/Nalco
520SITC of Jet Nozzle/Eyeball Diffuser Ø400mm along with VCD. Make-Glenstorm/Airflow/Systemaire
521Supply,installation,testing and commissioning of duct thermal insulation of Following Capacities , Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline . - with 25mm thick Nitrile Rubber Class O fire rated Insulation insulation conforming to BS476 Part6 and part 7 to provide the sufficient mechanical protection. The fibre glasscloth shall be factory laminated. The adhesive shall be SR 98 or equivalent sourced from OEM of nitrile rubber insulation.
522Supply ,& Fixing of Accoustic Class O fire rated Insulation insulation conforming to BS476 Part6 and part 7 15 mm thick of Armasound open cell nitrile rubber as per direction of Engineer-in-charge. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline
523SITC of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., Make-systemair/ventech/Air master/Ruskin Titus
524SITC of Fusible link mechanical fire damper complete with sleeve for fixing on retrun air opening.The damper shall be spring loaded and suitable for reset to original position.The damper also be provided with limit switch for transferring the signal to AHU starter panel/BMS for tripping the AHU in case of fire .The rate shall be inclusive of control wiring upto the Starter panel/DDC clopsing the opening surrounded by the sleeve with fire glass and fire sealant as per standards Fire Damper as per direction of Engineer-in-charge. Make-systemair/ventech/Air master/Ruskin Titus
525Control & Transmission Wiring :
526Control & Transmission Wiring- Providing & fixing control cum transmission wiring of 2 core x 1.0 sqmm shielded copper cable in HMS FRLS PVC conduits between indoor and out door unit as per direction of Engineer-in-charge. Make of cable - Finolex/Polycab/HAVELLS/Gloster/KEI/RR Kabel Make of conduit- AKG/BEC/Precision/Norpak/Anchor/Kinjal
527Supply and charging of Refrigerant R410A gas
528Supplying,fixing of hot dip galvanized GI unperforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 450mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
529Supply ,& Fixing of Flexible WATERPROOF FIRE RATED canvas connection in complete as per the direction of Engineer-in-charge.
530Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser with VCD having flange all around as per direction of Engineer-in-charge..Make-Glenstorm/Airflow/Systemaire
531Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around. as per direction of Engineer-in-charge. Make-Glenstorm/Airflow/Systemaire
532Supply, installation, testing and commissioning of factory fabricated double skinned rectangular inline type fans section made out of extruded aluminium section with 1.0 mm pre-plasticized / pre-coated Galvanised steel inside and outside with DIDW blower, blower section and blower motor TEFC type suitable for operation on 230 volts ± 10%, 50 Hz ± 5% AC supply with motor and belt drive package as per direction of Engineer-in-charge. MAKE - SYSTEMAIR/GREENHECK/ELTA
5332500 CFM @ 15mm MMWG static pressure
534Supplying, Fixing, testing and commissioning of Motorized fire dampers of minimum 120 minutes fire rated as per UL-555 and UL 555S,leakage class-1 in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized operated by AC/DC Actuator and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required. The damper housing of Galvanised Steel sheet construction, 16G GI casing and 16G GI Blades with chrome plated spindle, self lubricating bushes. The damper blade should be Heavy duty interlocking blades and fully enclosed blade linkage mechanism as per direction of Engineer-in-charge.. (Make: Air Flow/ Systemair/ Dynacraft/Greenheck)Fire damper(150 mm deep)
535Supply, installation, testing and commissioning of an electric spring-return actuator comply with UL 555 and UL 555S for fire and smoke dampers,UL listed, rated for 2-position (On/Off) control. The actuator shall be factory-fitted with an internal spring to ensure automatic closure upon power loss. It must include dual auxiliary switches for status monitoring (Open/Closed), a thermoelectric tripping device (72°C), and be rated for elevated temperatures (up to 350°F / 177°C). Operating Voltage 24V DC/ 230V AC. Complete with all necessary linkages, mounting brackets, and control wiring as per approved technical specifications. Torque rating as per final damper size with in 3Nm to 20Nm.The rate is inclusive of control panel and temperature response device and its wiring as per direction of Engineer-in-charge.. (Make:- Belimo/ Siemens/ Danfoss)
536Supply & Fixing of 19mm for underdeck insulation (Self Adhesive Only ) XLPE Physically / Chemically crosslinked polyethylene foam,with factory reinforced alupet foil facing, having Class O fire properties and very low fire propagation of < 5.5, passing E-84 at < 25/50,the density of the foam should be not less than 25-30kg/m3 and the maximum thermal conductivity K should be 0.032W/mK @23 Deg C , the permeability resistance factor u shouldn't be less than 14000 as per direction of Engineer-in-charge.. (Makes - Thermobreak / Trocellen/ Aerolam)
537DATA NETWORK
538SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit.
539SITC of Cat6 I/O with single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application as per direction of Engineer-in-charge.. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
540SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking as per direction of Engineer-in-charge.. Make: Systimax, Legrand, Panduit
541SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies as per direction of Engineer-in-charge.. Make: Systimax, Legrand, Panduit(1 mtr length)
542SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies as per direction of Engineer-in-charge.. Make: Systimax, Legrand, Panduit(2 mtr length)
543SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
544SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
545SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
546SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear
547SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP, Netgear
548SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
549SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand
550Supply and installation of Dual band 802.11ax WiFi6 Dual Band Access Point. Complying PoE+ for power, with inbuilt on premise virtual controller as well cloud based controlling and administration of WiFi systems All hardware should supplied with necessary mounting brackets and IN power cord with 3 years of comprehensive onsite warranty. Make: Cisco/Digisol/Netgear
551CCTV SURVILLENCE SYSTEM
552Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch
553Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch
554Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make-Honeywell value series /Pelco/Axis/Bosch
555Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
556SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
557SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer
558AUDIO SYSTEM SOLUCTION
559Sitc of sleek, low-profile, wall-mount full-range loudspeaker features a 4-inch (100 mm) polypropylene cone driver paired with a 1-inch (25 mm) silk dome tweeter, delivering a wide frequency range of 74 Hz to 20 kHz (-10 dB) and a consistent 130° x 120° coverage pattern. Multi-tap transformer for operation on 70V/100V distributed lines (with taps at 25W, 12.5W, 6.3W, and 3.2W) or as an 8-ohm direct system capable of handling 50 Watts of continuous program power. Down-angled coverage for flush-to-wall mounting using the included slide-on wall bracket, IP44-rated enclosure and included rain cover for the 4-pin Euroblock connector ensure durability in protected outdoor or high-moisture indoor environments. Make: QSC, Audac, Bose
560Sitc of compact, full-range pendant loudspeaker features 5.25-inch polypropylene-coated woofer and a 0.75-inch textile soft-dome tweeter in a coaxial configuration. It utilizes a large 200 mm waveguide with integrated low-frequency apertures to ensure a consistent and exceptionally wide 120° conical coverage pattern. Delivering a frequency range of 55 Hz to 20 kHz, 100 Watts of continuous program power at 8 ohms. It includes a 30W multi-tap transformer compatible with 70V and 100V distributed lines. IP44 splash-proof rating, resistance to humidity and salt spray, and a suspension system utilizing 4.5 m (15 ft) galvanized steel cables with adjustable locking fasteners. Make: QSC, Audac, Bose
561Sitc of four-channel power amplifier delivering 300W per channel at 4 or 8 ohms and supporting 70V/100V direct drive without the need for an external transformer. Integrated Digital Signal Processing (DSP) that includes an input router, up to 1000ms of input delay, 8-band parametric EQ for both input and output, crossovers, and advanced limiting technology. Signal-to-noise ratio of >104dB and a damping factor of >1000. Housed in a 2U rackmount chassis, it provides comprehensive network control and monitoring via standard TCP/IP protocols and comes pre-loaded with optimized speaker tunings to streamline system configuration. Make: QSC, Audac, Bose
562DSP(Digital signal processor ) and Amplifiers
563Sitc of 8-zone audio matrix designed for comprehensive multi-zone sound control. It features two balanced microphone inputs with priority functions and 15V phantom power, four stereo line-level inputs for various music sources, and eight wall panel ports that allow for additional local inputs and control. Each of the eight output zones provides balanced stereo line-level signals and can be managed via the front panel rotary dials, a web-based interface, App, or through RS232 and TCP/IP integration for automation. For enhanced reliability, the unit includes a 24V DC emergency power input to ensure continued operation during mains power failures, all housed in a compact 2 HE rack-mountable chassis. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge Make: QSC, Audac, Bose,Xilica
564Sitc of 8-zone paging microphone featuring electret condenser capsule with a cardioid pickup pattern and a 250 mm tiltable pipe-neck. Compatable audio matrix systems, it employs a sleek glass front panel with capacitive, illuminated buttons and integrated chime functionality. 24V DC supply over a digital RS-485 databus (up to 300m via CAT5E) and frequency response of 50 Hz - 16 kHz with a maximum SPL of 130 dB. ABS construction measures 221.5 x 43 x 111.6 mm and includes a fixed 2-meter connection cable with an RJ45 connector.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge Make: QSC, Audac, Bose
565Sitc of Universal wall panel - Microphone, line & Bluetooth receiver - 80 x 80 mm Compatable with Audio Matrix Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge . Make: QSC, Audac, Bose
566Sitc of Modular audio system featuring four interface card slots that support simultaneous operation of various modules, including 1 No FM, DAB/DAB+ Module, 1 No internet radio Module,1 No Bluetooth Module, and voice file players. Encased in a steel chassis measuring 482 x 44 x 330 mm, 2.8\\" graphical LCD display with a push-rotary dial and four tactile buttons for intuitive control, alongside four front-panel USB ports and a built-in PFL speaker for individual source monitoring. Technical performance includes a frequency response of 20 Hz – 20 kHz (± 3 dB) and flexible control options via RS-232, TCP/IP, or web interface. The unit operates on a wide-range switching power supply (110–240V AC) with a base power consumption of 2 W and offers optional high-quality, low-latency audio networking via a Dante™ expansion interfaceBefore final procurement, the final design shall be approved by the concerned client and Engineer-in-charge . Make: QSC, Audac, Bose
567Sitc of Audio Matrix and Player Control Software for PC and I pad Make: QSC, Audac, Bose
568Sitc of 1.5 Sqmm (48/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath. Make: Krystals/ Kramer/ Belden
569EXTERNAL ILLUMINIOUS LIGHT:
570Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.The price inclussive of of 4 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-400 + KL-25444 Luminaries/Reytek/Philips/Homdec/Jaquar).
571Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer ) equievalant make ISI marked as approved as per direction of Engg. in Charge.
572SITC of 24 W Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire made of extruded aluminium alloy (grade 6063), spun aluminium top cover Ø293 x 1.6mm thickness. Turn type polycarbonate locking system for easy maintenance and non corrosive stainless steel fasteners. Translucent acrylic diffuser. Pressure die-cast aluminium mounting plate Ø100.5 x 4mm thickenss with 2 elongated holes 15 x 10 to suit M8 bolts at PCD 55 for surface mounting on floor.Protection class IP54. Mechanical resistance IK08. Decorative die cast aluminium rook base cover. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Prewired with E27 holder and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 250mm diameter x 900mm height.(MAKE:klite(Vista bollard 24W M3)
573STREET LIGHT: S/I/T&Commissioning of LT OUT DOOR double door cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & painted by simens gray powder coated paint is designed as G.A drawing. (FOR USE) with 63A FP MCCB, 16kA, adjustable thermal relaese, Ics=100%Icu 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, 100A Aluminium busbar, OLR,RYB,ON,OFF trip indication, 3P+N Type-II SPD 40ka alongwith 63A, 4P MCB,C series, 10kA for the incoming feeder,04 nos 16A 4P MCB,C,10KA as outgoing with 100A stud connector with Undervoltage and overvoltage voltage monitoring relay, Make of- MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200), Make of- MCCB legrand dPx3/ schneider CVS/ Siemens 3VA/ ABB Formula, Make of SPD-ABB/siemens/Schneider/Legrand/OBO/Dehn as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 5 years of acceptance of materials.The panel should be mounted on hot dip GI C channel alongwith RCC foundation.The GA Drawing shall be approved by the SEEC(R&B), Odisha, Bhubaneswar before execution of the work.
574Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
5753.5 core x 25 sq mm Aluminium armoured Cable.(FOR street PANEL)
5764 core x 10 sqmm A2XFY
5774 core x 6 sqmm A2XFY
578Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
579Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
580FAÇADE LIGHT
581SITC of high quality long through multi colour with RGBW 4in1 LED, DMX-RDM based Linear wash light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598 (Part 2/Sec 1):2020\\", and \\"Electromagnetic Compatibility Directive - EN 61547:2020\\", Mounting Structure: Adjustable Aluminum Extruded /SS surface mount yoke arrangements for fixing the lights having the rotation degrees embossed in the die cast. Power consumption: 80W, CCT: RGBW (3000K/6500K) (as per the design approval), Luminous efficacy >45lm/W, Optics: PMMA/PC Lens with separate holder, Beam Angle: 25°/45°/60°/ Asymmetrical deg as per the design approval, A soft copy of the IES file, catalogues, polar diagrams, cone diagrams shall be submitted along with the bid, Colour Rendering Index (CRI)>80 for white LED, Body: Die casted/ extruded aluminium with embossed manufacturer logo, Separate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution: Optics Designed to minimize hot spots & fringing in colour mixing applications. Luminaire shall be capable of producing dynamic colour-changing light with 16 million colours and it shall support control via DMX, Ethernet, and Remote Device Management (RDM) for enhanced configuration and management. The luminaire should offer channel options of 8/ 4 channels by using a Programming kit, with these channels providing control for effects and colour transitions like 4 colour 4 channels, Master, Jump, strobe, Macro function and speed in the rest 4 channels as per the requirement. Additionally, it shall feature auto colour synchronization functionality, allowing seamless operation if there is a loss of DMX signal/ with loop in loop out. Power Input: DC 24V External Group Driver Class III having the efficiency >90, THD <10%, Surge Protection: Inbuilt surge protection in the driver 2KV-4KV (Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection: IK07 or higher, Painting: Chemical 3/7 tank processed treatment before the powder coat black/Grey/approved colour coat. Fixture will be suitable to operate in a temperature range of -10°C to +60°C, the light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35-micron Copper, 2W TC with Black or White masking, Copper /OSP finish. OEM must have in-house NABL-approved testing facilities for LED fixtures. LM79, IK07, IP66, Electrical, Endurance and Thermal, Surge Certificates must be submitted from the In-house NABL testing facility. LED Makes should be CREE, LumiLED, Osram, Seoul, Nichia or equivalent with LM80 report from as international testing Laboratory having the L70B50, 50000Hrs at 25 Deg C or better. Power & DMX Loop In/Out along with IP67 connector having the length >300mm. Certifications: CE, RoHS, BIS with valid R number must be submitted along with the bid.Make: LEKSKA LIGHTING/CANARA LIGHTING/LT/JAQUAR
582SITC of high quality aluminium frame with Multi Color Neon Flexible light, Protection Rating : IP65, Mounting Structure : Adjustable wall mount aluminium profile for fixing the lights. Power consumption : 12W, CCT : RGB/RGBW, (as per the design approval) Beam Angle : 120º, Control : DmX512 Channel : 4 CH, Power Input : DC 24V with external driver, Surge Protection : Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Fixture will be suitable to operate in a temperature range of 0°C to 50°C , LED life time should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. LED Makes should be CREE, LumilLED, Osram, Seoul, Epistar, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Make: LEKSKA LIGHTING/CANARA LIGHTING/LT/JAQUAR
583SITC of high quality long through multi colour with RGBW 4in1 LED, DMX-RDM based wash light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598 (Part 2/Sec 1):2020\\", and \\"Electromagnetic Compatibility Directive - EN 61547:2020\\", Mounting Structure: Adjustable surface mount yoke arrangements for fixing the lights having the rotation degrees embossed in the die cast. Power consumption: 50W, CCT: RGBW (3000K/6500K) (as per the design approval), Luminous efficacy >45lm/W, Optics: PMMA/PC Lens with separate holder, Beam Angle: 25°/45°/60°/ Asymmetrical deg as per the design approval, A soft copy of the IES file, catalogues, polar diagrams, cone diagrams shall be submitted along with the bid, Colour Rendering Index (CRI)>80 for white LED, Body: Die casted/ extruded aluminium with embossed manufacturer logo, Separate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution: Optics Designed to minimize hot spots & fringing in colour mixing applications. Luminaire shall be capable of producing dynamic colour-changing light with 16 million colours and it shall support control via DMX, Ethernet, and Remote Device Management (RDM) for enhanced configuration and management. The luminaire should offer channel options of 8/ 4 channels by using a Programming kit, with these channels providing control for effects and colour transitions like 4 colour 4 channels, Master, Jump, strobe, Macro function and speed in the rest 4 channels as per the requirement. Additionally, it shall feature auto colour synchronization functionality, allowing seamless operation if there is a loss of DMX signal/ with loop in loop out. Power Input: DC 24V External Group Driver Class III having the efficiency >90, THD <10%, Surge Protection: Inbuilt surge protection in the driver 2KV-4KV (Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection: IK08 or higher, Painting: Chemical 3/7 tank processed treatment before the powder coat black/Grey/approved colour coat. Fixture will be suitable to operate in a temperature range of -10°C to +60°C, the light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35-micron Copper, 2W TC with Black or White masking, Copper /OSP finish. OEM must have in-house NABL-approved testing facilities for LED fixtures. LM79, IK08, IP66, Electrical, Endurance and Thermal, Surge Certificates must be submitted from the In-house NABL testing facility. LED Makes should be CREE, LumiLED, Osram, Seoul, Nichia or equivalent with LM80 report from as international testing Laboratory having the L70B50, 50000Hrs at 25 Deg C or better. Power & DMX Loop In/Out along with IP67 connector having the length >300mm. Certifications: CE, RoHS, BIS with valid R number must be submitted along with the bid.Make: LEKSKA LIGHTING/CANARA LIGHTING/LT/JAQUAR
584SITC of high quality long through multi colour with RGBW 4in1 LED, DMX-RDM based wash light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598 (Part 2/Sec 1):2020\\", and \\"Electromagnetic Compatibility Directive - EN 61547:2020\\", Mounting Structure: Adjustable surface mount yoke arrangements for fixing the lights having the rotation degrees embossed in the die cast. Power consumption: 100W, CCT: RGBW (3000K/6500K) (as per the design approval), Luminous efficacy >45lm/W, Optics: PMMA/PC Lens with separate holder, Beam Angle: 25°/45°/60°/ Asymmetrical deg as per the design approval, A soft copy of the IES file, catalogues, polar diagrams, cone diagrams shall be submitted along with the bid, Colour Rendering Index (CRI)>80 for white LED, Body: Die casted/ extruded aluminium with embossed manufacturer logo, Separate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution: Optics Designed to minimize hot spots & fringing in colour mixing applications. Luminaire shall be capable of producing dynamic colour-changing light with 16 million colours and it shall support control via DMX, Ethernet, and Remote Device Management (RDM) for enhanced configuration and management. The luminaire should offer channel options of 8/ 4 channels by using a Programming kit, with these channels providing control for effects and colour transitions like 4 colour 4 channels, Master, Jump, strobe, Macro function and speed in the rest 4 channels as per the requirement. Additionally, it shall feature auto colour synchronization functionality, allowing seamless operation if there is a loss of DMX signal/ with loop in loop out. Power Input: DC 24V External Group Driver Class III having the efficiency >90, THD <10%, Surge Protection: Inbuilt surge protection in the driver 2KV-4KV (Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection: IK08 or higher, Painting: Chemical 3/7 tank processed treatment before the powder coat black/Grey/approved colour coat. Fixture will be suitable to operate in a temperature range of -10°C to +60°C, the light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition.
585SITC of high quality long through multi colour with RGBW 4in1 LED, DMX-RDM based wash light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598 (Part 2/Sec 1):2020\\", and \\"Electromagnetic Compatibility Directive - EN 61547:2020\\", Mounting Structure: Adjustable surface mount yoke arrangements for fixing the lights having the rotation degrees embossed in the die cast. Power consumption: 150W, CCT: RGBW (3000K/6500K) (as per the design approval), Luminous efficacy >45lm/W, Optics: PMMA/PC Lens with separate holder, Beam Angle: 25°/45°/60°/ Asymmetrical deg as per the design approval, A soft copy of the IES file, catalogues, polar diagrams, cone diagrams shall be submitted along with the bid, Colour Rendering Index (CRI)>80 for white LED, Body: Die casted/ extruded aluminium with embossed manufacturer logo, Separate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution: Optics Designed to minimize hot spots & fringing in colour mixing applications. Luminaire shall be capable of producing dynamic colour-changing light with 16 million colours and it shall support control via DMX, Ethernet, and Remote Device Management (RDM) for enhanced configuration and management. The luminaire should offer channel options of 8/ 4 channels by using a Programming kit, with these channels providing control for effects and colour transitions like 4 colour 4 channels, Master, Jump, strobe, Macro function and speed in the rest 4 channels as per the requirement. Additionally, it shall feature auto colour synchronization functionality, allowing seamless operation if there is a loss of DMX signal/ with loop in loop out. Power Input: DC 24V External Group Driver Class III having the efficiency >90, THD <10%, Surge Protection: Inbuilt surge protection in the driver 2KV-4KV (Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection: IK08 or higher, Painting: Chemical 3/7 tank processed treatment before the powder coat black/Grey/approved colour coat. Fixture will be suitable to operate in a temperature range of -10°C to +60°C, the light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35-micron Copper, 2W TC with Black or White masking, Copper /OSP finish. OEM must have in-house NABL-approved testing facilities for LED fixtures. LM79, IK08, IP66, Electrical, Endurance and Thermal, Surge Certificates must be submitted from the In-house NABL testing facility. LED Makes should be CREE, LumiLED, Osram, Seoul, Nichia or equivalent with LM80 report from as international testing Laboratory having the L70B50, 50000Hrs at 25 Deg C or better. Power & DMX Loop In/Out along with IP67 connector having the length >300mm. Certifications: CE, RoHS, BIS with valid R number must be submitted along with the bid. Make: LEKSKA LIGHTING/CANARA LIGHTING/LT/JAQUAR
586SITC of high quality long through multi colour with RGBW 4in1 LED, DMX-RDM based wash light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598 (Part 2/Sec 1):2020\\", and \\"Electromagnetic Compatibility Directive - EN 61547:2020\\", Mounting Structure: Adjustable Double panel surface mount yoke arrangements with individual module rotating options,having the rotation degrees embossed in the die cast. Power consumption: 180W, CCT: RGBW (3000K/6500K) (as per the design approval), Luminous efficacy >45lm/W, Optics: PMMA/PC Lens with separate holder, Beam Angle: 25°/45°/60°/ Asymmetrical deg as per the design approval, A soft copy of the IES file, catalogues, polar diagrams, cone diagrams shall be submitted along with the bid, Colour Rendering Index (CRI)>80 for white LED, Body: Die casted/ extruded aluminium with embossed manufacturer logo, Separate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution: Optics Designed to minimize hot spots & fringing in colour mixing applications. Luminaire shall be capable of producing dynamic colour-changing light with 16 million colours and it shall support control via DMX, Ethernet, and Remote Device Management (RDM) for enhanced configuration and management. The luminaire should offer channel options of 8/ 4 channels by using a Programming kit, with these channels providing control for effects and colour transitions like 4 colour 4 channels, Master, Jump, strobe, Macro function and speed in the rest 4 channels as per the requirement. Additionally, it shall feature auto colour synchronization functionality, allowing seamless operation if there is a loss of DMX signal/ with loop in loop out. Power Input: DC 24V External Group Driver Class III having the efficiency >90, THD <10%, Surge Protection: Inbuilt surge protection in the driver 2KV-4KV (Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection: IK08 or higher, Painting: Chemical 3/7 tank processed treatment before the powder coat black/Grey/approved colour coat. Fixture will be suitable to operate in a temperature range of -10°C to +60°C, the light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35-micron Copper, 2W TC with Black or White masking, Copper /OSP finish. OEM must have in-house NABL-approved testing facilities for LED fixtures. LM79, IK08, IP66, Electrical, Endurance and Thermal, Surge Certificates must be submitted from the In-house NABL testing facility. LED Makes should be CREE, LumiLED, Osram, Seoul, Nichia or equivalent with LM80 report from as international testing Laboratory having the L70B50, 50000Hrs at 25 Deg C or better. Power & DMX Loop In/Out along with IP67 connector having the length >300mm. Certifications: CE, RoHS, BIS with valid R number must be submitted along with the bid.Make: LEKSKA LIGHTING/CANARA LIGHTING/LT/JAQUAR
587SITC of DC power driver for the above Lights, Power : 200W, Input : AC 110-240V AC, 50Hz, Output : DC 12/24V, Protection rating, IP67, Surge protection : LL 4KV, LE 6KV
588SITC of high quality DMX decoder, Power Input : DC 24V, Input Signal: DMX512, Addressing: You can manually set DMX addresses using DIP switches or digital displays, Smooth Dimming: Enables 0–100% dimming and dynamic effects like fading or color chasing. IP Rating: IP20.
589SITC of PVC insulated multi core electrical un armored flexible 5C x 0.5Sq mm power cable having less electrical losses. (As per actuals depending upon the site condition)
590SITC of PVC insulated multi core electrical un armored flexible 3C x 1.5Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands copper conductors and it supports voltage grade up to 1100V. (As per actuals depending upon the site condition)
591SITC of PVC insulated multi core electrical un armored flexible 3C x 2.5Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands copper conductors and it supports voltage grade up to 1100V. (As per actuals depending upon the site condition)
592SITC of PVC insulated multi core electrical armored flexible 4C x 6Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands aluminium conductors and it supports voltage grade up to 1100V. (As per actuals depending upon the site condition)
593SITC of 5 core DMX cable comprises twisted pairs with shield support for carrying of data. DMX512 cable is used for connecting all light consoles that use DMX 512 standard data transmission. (As per actuals depending upon the site condition)
594SITC of 5 pin XLR Male connectors having 5 pole cable connector, Male/Female connector with improved latch, cage type contacts, \\"solder stop\\" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability.
595SITC of 5 pin XLR Female connectors having 5 pole cable connector, Male/Female connector with improved latch, cage type contacts, \\"solder stop\\" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability.
596SITC of Power Distribution Board made up of MS Sheet metal fabricated housing black powder coated and ivery connectors for the internal terminations and external outgoing connecting points, fibre / brass glands of suitable size fitted MCB control for outgoing circuits. Timer with required contactor for auto switching. Power panel suitable for indoor/outdoor applicable and floor mount / wall mount options.- 22 Nos of 6/10A SP Outgoing MCBs. - 1No of 63A TPN Incoming MCB.
597SITC of IP driver box made up of PVC / UPVC for the internal terminations and external outgoing connecting points, with required PVC / brass glands, Optional suitable size MCB fitted for control outgoing circuits.
598SITC of DMX signal amplifier for improving/amplifying the input signals through longer distances. Signal regeneration: Boosts weakened DMX signals after long-distance transmission. Input Volatage: 12V/24V, IP Ratating: IP20.
599SITC of DMX isolator or splitter provides Isolated optical DMX splitter provides 8 outputs from a 1 input and Input voltage: AC 110 to 220 V, 50 Hz, Product features: Group 1 & group 8 DMX signal change.
600SITC of Din Rail Mount DMX controller can be used to control a wide variety of different DMX systems- from RGB/RGBW to more advanced moving and color mixing luminaires, DMX audio players and fountains. The controller comes with a variety of features, iPhone/iPad/Android remote control, Wi-Fi facilities, dry contact port triggering and flash memory. USB connection • 2048 DmX channels universe in live mode (computer) • 8 dry contact trigger ports via HE10 connector • stand alone mode with 5 area and 90+ scenes, Mac OSx 10.6/10.7/10.8 - Windows XP/VISTA/SEVEN/8 32/64 bits and USB 2.0, XLR3, mini USB, 1 HE10, Power From 5V to 5.5V DC (AC/DC adapter in option.
601Programming charges as per site conditions or client's approval (18 scenes ).
602SITC of additional accessories for installing the lights as per the final drawing/site condition consisting of clamps, brackets, angles, conduits, joints, hardware's like fasteners, nut & bolts etc.,
603L.T. PANELS :
604Supply ,Testing commisioning of of SITC of Power Distribution Board made up of MS Sheet metal fabricated housing blackpowder coated an dilvery connectors for the internal terminations and external outgoing connecting points,fibre/brass glands of suitable size fitted MCB control for outgoing circuits.Outgoing MCB's - 14 Nos of 16 A DP IncomingMCCB's.- 1No of 125A 4P MCCB 25 KA .Instruments: 1 set.LED type phase indicating lamps with control fuses,Multifunction meter with 125/5 amp ct opearted Complete duly factory wired as per SLD and panel should have proper earth by suitable rated Aluminium flat earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge
605PUMPS AND APPURTENANCES
606Supply , installation, testing & commissioning of Motor driven end suction Back pullout type Centrifugal pump delivering 2280 LPM at 70 Mtr head with CI casing bronze impeller and SS shaft with mechanical seal (for Wet riser & Sprinkler system) with 2 pole TEFC motor suitable for operation on 415 V ,3 ph, 50 C/s AC supply and complying to TAC norms including providing base frame coupling,coupling guard as per direction of Engineer-in-charge (Make:PUMP:Kirloskar/ Grundfos / KSB/ Wilo)
607Supply , installation, testing & commissioning of Diesel Engine driven end suction Back pullout type Centrifugal pump having 2280 LPM at 70 Mtr head with CI casing bronze impeller and SS shaft with mechanical seal and suitable diesel engine complying to TAC norms along with all accessories including control wiring between panel & DG set and fuel storage tank including providing base frame coupling,coupling guard as per direction of Engineer-in-charge..(Make:PUMP:Kirloskar/ Grundfos / KSB/Wilo)
608Supply , installation, testing & commissioning of Motor driven end suction Back pullout type Centrifugal Jocky pump delivering 180 LPM at 70Mtr head with CI casing bronze impeller , SS shaft with mechanical seal and 2 pole TEFC electric motor suitable for operation on 415 V ,3 ph, 50 C/s AC supply including providing base frame coupling,coupling guaaard as per direction of Engineer-in-charge..(Make:Kirlosker/ Gunfoss / KSB/ wilo)
609Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.Make-Wilo/KSB/Kirloskar/Grundfoss
610S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by Red out & inside gray powder cote paint is designed as G.A drawing. (FOR FIRE FIGHTING)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 40kA SPD alongwith 63A, 4P, MCB, C series, 10kA shall be installed in the incomer. 40X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Mandatory provision of cable alley is to be given.INCOMING: One(1)- 200 Amp 25 KA TP with solid neutral SDFU with HRC fuses 3 nos (Make-Legrand/Siemens/Schneide/ABB) including 01 no of MFM with RS 485, 3 Nos 200/5 metering CTs of Class 1.0, ON/ OFF indicating lamps, 3 Nos Phase indicating lamp and SP 6A MCB ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200). . Busbar- 04 numbers of 300Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. OUTGOING: a)One(1)-160 Amp 25kA TP MCCB with ROM 25kA with adjustable MICRO PROCESSOR Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA), along with star delta starter incorporating 3 nos Power 3P contactor with top add on(2NO+2NC) ,Bimetal OLR of suitable rating,axulary contactor , ON/ OFF push button, ON/ OFF indicating lamp, 3 Nos CTs metering CTs 250/5, Ammeter .b) 1 No (Outgoing) – 63 Amp 25kA TP MCCB with ROM 25kA with adjustable MICRO PROCESSOR Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA), along with star delta starter suitable for motor with O/L release, ON/ OFF push button, ON/ OFF indicating lamp,3nos 100/5 CT,Ammeter,S/Sc) 1 Set – Relay, Auto/ Manual Selector Switch, Battery Charger, Annunciation Panel,hotor, Control wiring of pressure switches, flow switches and starters etc as required for auto and manual operation of Jockey pumps, Main Electric Pumps and Diesel Engine Pump as per direction of Engineer-in-charge.d)1 lot control wiring from pressure switch to panel board through auxiliary contactor with 1.5 sq. mm unarmoured PVC insulated ,PVC sheathed copper cable etc as required.
611Supply, installation, testing and commissioning of CPRI Approved Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MPCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF/TRIP indication lamps, Auto manual switch, provision for interlocking with pressure switch should be provided and ON/OFF push button.as per direction of engineer in charge.make-Legrand/schneider/Siemens/ABB
612Supply & Laying of XLPE armoured aluminum power cable of 1.1 KV grade of following size on Cable Make - Polycab / KEI/Gloster/RR kabel/Havells/Finolex
6133C X 70 sqmm
6143C X 16 sqmm
6158C X 2.5 sqmm
6162C X1.5 sqmm
617End Termination
618Supply & Making end Termination with brass double compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable)
6193C X 70 sqmm
6203C X 16 sqmm
621PIPE & VALVES ETC.
622Supplying, installation testing and commissioning of the following-: ‘C’ class GI Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pipe coat (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete.Make-TATA/SAIL/JINDAL
623200mm NB
624150mm NB
625100mm NB
62680mm NB
62765mm NB
62850mm NB
62940mm NB
63032mm NB
63125mm NB
632Supply and installation, testing and commissioning of CI Butterfly valves ( heavy ) conforming to BS 5155 ,PN1.6 tested to 1.5 times working pressure with necessary companion flanges, bolts, nuts, gasket packing, support and any other spares, including indicator for open and shut position as per fire practice etc complete..Make-Zoloto/Audco/Leader
633150mm NB
634100mm NB
63580mm NB
636SITC of NRV conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.6 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete as per direction of Engineer-in-charge. It shall be ISI Marked .Make-Zoloto/Audco/Leader
637150mm NB
638100mm NB
639Supply,Installation,Testing & Commissioning of orifice plate made of 6mm thick stainless steel with orifice of required size in between flane and landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 Kg/ sq cm complete as required.
640Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: H.GURU/G.GURU
641Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: DANFOSS/INDFOSS
642Supply,Installation,Testing & Commissioning of stainless steel Y strainer fabricated out of 1.6 mm thick stainless steel sheet with 3 mm dia hloes with stainless steel flange as required.Make-Zoloto/AUDCO/Leader150 MM
643100 MM
644Supply,Installation,Testing & Commissioning of Air vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required as per direction of Engineer-in-charge.
645Supply,Installation,Testing & Commissioning of 150 NB C.I. PRV with matching flanges as per direction of Engineer-in-charge.
646Supply,Installation,Testing & Commissioning of 150NB Alarm Valve , Water Motor Gong Retarded Chamber, Flange to:- ANSI B 16. 1 Class 125/ANSI B16.5 Class 100, All Components are UL Listed/FM Approved , Rated pressure 17.50 kg/cm2, Test pressure 500PSI confirming to IS :15105:2002 with ISI mark as per direction of Engineer-in-charge. Make-Newage/Honeywell/Minimax Please Enable Macros to View BoQ information
647Supply,Installation,Testing & Commissioning of 150NB Alarm Valve , Water Motor Gong Retarded Chamber, Flange to:- ANSI B 16. 1 Class 125/ANSI B16.5 Class 100, All Components are UL Listed/FM Approved , Rated pressure 17.50 kg/cm2, Test pressure 500PSI confirming to IS :15105:2002 with ISI mark as per direction of Engineer-in-charge. Make-Newage/Honeywell/Minimax Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56633489
AUTHORITY Government Departments
TENDER VALUE 22.50 Crore
LAST DATE 07-08-2026
Authority
Authority Name Orissa Tourism Development Corporation Limited
Work Description Tender for Construction And Development Of Sand Art Park At Puri
Basic Detail
Tender No ACE/OTDC/02/2026-27 dt. 17.07.2026
Bidding Type Tender
Location
City Puri
State Odisha
Key Dates
Publish Date 24 Jul 2026
Submission Date 07 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 22.50 Crore
Tender Fee 10000
EMD 22.50 Lakhs
Exemption Not Available
Document List
afcb07da-3b61-4739-bf52-0bda08c927a8.html
BOQ_603167.xls
DTCN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

afcb07da-3b61-4739-bf52-0bda08c927a8.html

xls

BOQ_603167.xls

pdf

DTCN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders