Public Administrative Department Government Departments Closing in 19 days TDR #56630553

Tender For Execution Of Work Under (Ow) Repairing And Upgradation Of Staff Quarter And Toilet At The Adjacent Complex Of Hira Gate At Dabhoi.

Issued by Government Departments · Vadodara, Gujarat
Tender Value
28.16 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
19 days left
EMD
70400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Execution Of Work Under (Ow) Repairing And Upgradation Of Staff Quarter And Toilet At The Adjacent Complex Of Hira Gate At Dabhoi.

BOQ

Name of Work:- Execution of Work under (OW) Repairing and upgradation of Staff Quarter and Toilet at the adjacent complex of Hira Gate at Dabhoi.
Sl. No. Item Description
1Execution of work under following items
2Towards the Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 meter & up to 150 meter depth below ground level. 23.2.1 All types of soil. 300 mm dia. (Including all the materials & labour charges etc. complete as direction by site in charge)
3Towards supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia.(Including all the materials & labour charges etc. complete as direction by site in charge)
4Towards supplying, assembling, lowering and fixing in vertical position in bore well un-plasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge150 mm nominal size dia. (Including all the materials & labour charges etc. complete as direction by site in charge)
5Towards supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (Including all the materials & labour charges etc. complete as direction by site in charge)
6Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (Including all the materials & labour charges etc. complete as direction by site in charge)
7Towards providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp. (Including all the materials & labour charges etc. complete as direction by site in charge)
8Towards providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall40 mm nominal dia Pipes. (Including all the materials & labour charges etc. complete as direction by site in charge)
9Towards providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall32 mm nominal dia Pipes. (Including all the materials & labour charges etc. complete as direction by site in charge)
10Towards providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall25 mm nominal dia Pipes. (Including all the materials & labour charges etc. complete as direction by site in charge)
11Towards the Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. (Including all the materials & labour charges etc. complete as direction by site in charge)
12Towards CEMENT PLASTER ((IN COARSE SAND)) 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (Including all the materials & labour charges etc. complete as direction by site in charge)
13Towards disposal of building rubbish / melba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (Including all the materials & labour charges etc. complete as direction by site in charge)
14Towards providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (Including all the materials & labour charges etc. complete as direction by site in charge)
15Towards distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and color all complete to achieve even shade and color : New work (two or more coats) over and including water thinkable priming coat with cement primer having VOC content less than 50 gram/litre. (Including all the materials & labour charges etc. complete as direction by site in charge)
16Towards finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm). (Including all the materials & labour charges etc. complete as direction by site in charge)
17Towards the dismantling doors, windows and clerestory windows (steel or wood)Of area 3 sq. meters and below shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead :Of area 3 sq. meters and below. (Including all the materials & labour charges etc. complete as direction by site in charge)
18Towards providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminum sections shall be smooth, rust free, straight, mired and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion;-Powder coated aluminum (minimum thickness of powder coating 50 micron). (Including all the materials & labour charges etc. complete as direction by site in charge)
19Towards providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm). (Including all the materials & labour charges etc. complete as direction by site in charge)
20Towards filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Up to 5 mm depth and 5 mm width. (Including all the materials & labour charges etc. complete as direction by site in charge)
21Towards Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (Including all the materials & labour charges etc. complete as direction by site in charge)
22Towards the Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C. (Including all the materials & labour charges etc. complete as direction by site in charge)
23Towards the Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated \copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. \\"2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (Including all the materials & labour charges etc. complete as direction by site in charge)
24Towards the Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated \copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. \\"2 X 6 sq. mm + 1 X 6 sq. mm earth wire. (Including all the materials & labour charges etc. complete as direction by site in charge)
25Towards supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch. (Including all the materials & labour charges etc. complete as direction by site in charge)
26Towards supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet. (Including all the materials & labour charges etc. complete as direction by site in charge)
27Towards supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.6 Module (200mmX75mm). (Including all the materials & labour charges etc. complete as direction by site in charge)
28Towards supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)\\"6 way (4 + 18), Double door. (Including all the materials & labour charges etc. complete as direction by site in charge)
29Towards supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole Single pole. (Including all the materials & labour charges etc. complete as direction by site in charge)
30Towards supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole Triple pole. (Including all the materials & labour charges etc. complete as direction by site in charge)
31Towards provision for supply and installation 2 HP 3 phase Submersible pump in existing bore well including necessary electrical starter panel all complete as per direction of site- in charge. (Including all the materials & labour charges etc. complete as direction by site in charge)
32Earth work in excavation by manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (Including all the materials & labour charges etc. complete as direction by site in charge)
33Towards the Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil. (Including all the materials & labour charges etc. complete as direction by site in charge)
34Towards filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Including all the materials & labour charges etc. complete as direction by site in charge)
35Towards supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (Including all the materials & labour charges etc. complete as direction by site in charge)
36Towards providing and laying in position cement concrete (pcc) of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement: 3 coarse sand (zone-III): 6 graded stone aggregate 20 mm nominal size). (Including all the materials & labour charges etc. complete as direction by site in charge)
37Towards centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butter esses, plinth and string courses etc. (Including all the materials & labour charges etc. complete as direction by site in charge)
38Towards centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. (Including all the materials & labour charges etc. complete as direction by site in charge)
39Towards providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). (Including all the materials & labour charges etc. complete as direction by site in charge)
40Towards the Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (Including all the materials & labour charges etc. complete as direction by site in charge)
41Towards providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipe for soil, waste and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all necessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without door), reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/celling/floor level support by hangers etc in concealed/ inside duct/under floor & basement celling / external work etc. including chase cutting as required excavation and back filling in all kind of soil suspended from floor under false celling or embedding the pipes laid under floors / building in 75mm. Around 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of shuttering for proper completion of work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS : 5382. : The pipes will be supported with threaded G.I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work include commissioning of all pipe lines as per drawings and specifications and as directed by Engineer-in-charge : 100 mm nominal dia. (Including all the materials & labour charges etc. complete as direction by site in charge)
42Towards supplying & laying of one number PVC insulated and PVC sheathed 4 Core 16 SQMM Armed power copper cable in existing DWC Pipe etc. as required. (Including all the materials & labour charges etc. complete as direction by site in charge)
43Towards supplying & laying of one number PVC insulated and PVC sheathed 3.5 Core 50 SQMM Armed power copper cable in existing DWC Pipe etc. as required. (Including all the materials & labour charges etc. complete as direction by site in charge)
44Towards supply, Installation, Testing and Commissioning of both side openable double door(back & front) Outdoor Type Feeder Pillar suitable for 415V, 3 Phase, 4 Wire 50 Hz AC supply system having suitable fabricated with CRCA sheet steel of 1.6 mm thick and 2 mm thick for slanted roof & gland plates with 400 mm long Leg & base frame made of 40X40X06 mm MS Angle i/c Powder Coated Paint in approved shade , Aluminum Alloy bus bars of 160A Capacity, connections, interconnections with adequate size aluminum bars, cables, connectors etc. along with necessary nuts & bolts, clamps, DMC/ SMC bus bar supports, with necessary M.S. channel, MS Flat, door handle, go down lock, padlock, both side louvers, Aluminum Danger Plate on brick mortar foundation, with PCC Base casting i/c excavation, entire feeder pillar shall have a common GI earth bar, cable gland plates , i/c following accessories. (Including all the materials & labour charges etc. complete as direction by site in charge)
45Towards providing and fixing 100 Amp, 25kA Four Pole MCCB in factory make enclosure for terminating Electricity Board Service Connection after Energy Meter, i/c making connections, testing commissioning complete etc. as required. (Including all the materials & labour charges etc. complete as direction by site in charge)
46Towards supply, installation, testing and commissioning of suitable wattage Flood light fixtures complete with energy efficient LEDs. IP 65 / IP 66 housing, driver, all other accessories etc. duly wired complete for use on 240 V single phase 50 Hz AC i/c fixing on MS Channel of suitable size & Length on existing street light Pole, connection etc. complete as per specifications as required. (Including all the materials & labour charges etc. complete as direction by site in charge)
47Towards supply & Installation testing & Commissioning of 10 M mini mast suitable for withstanding 35 MS wind speed, with ladder arrangement, in built junction box, head frame, luminaries carriage suitable to install 06 Nos. luminaries in symmetrical arrangement, junction box, lightning finial, i/c foundation (RCC) of High Mast should be as per manufacturer's recommendation as reqd. [EACH]. (Including all the materials & labour charges etc. complete as direction by site in charge)
48Towards supply, installation, testing and commissioning of Stanchion track light with track system wattage not less than 9 W along with all accessories, connection and to be fitted on wall/ down rod/ chain etc complete as required. (Including all the materials & labour charges etc. complete as direction by site in charge)
49Towards supplying and fixing adequate size of heavy-duty HDPE pipe outer dia 63mm, having working pressure 4Kg/ Sq.cm. at a depth of 75 Centimeter below the ground including excavation &, refilling the trench etc, of following sizes complete as required. (Avg.500 characters) on Jodhpur Yellow stone surface with all graphic work as required including mounding work, earth work, cement concrete etc all as per instruction of EIC. (Including all the materials & labour charges etc. complete as direction by site in charge)
50Towards providing and fixing 19 mm thick ISO 710 certified (Marine Grade) plywood over an existing Mild Steel (MS) framework. Item includes cutting to required sizes, drilling, counter-sinking, and securing the plywood using high-quality self-tapping star screws, bolts, or fasteners at required intervals. Rate shall include the cost of all materials, hardware, labor, wastage, scaffolding, tools, plants, and transportation, completed in all respects as per the drawings, specifications, and directions of the Site-in-Charge. (Including all the materials & labour charges etc. complete as direction by site in charge)
51Towards providing and fixing stainless steel (Grade 304) structure as per approved design for Direction/ information board, made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the legs in pits (0.3mX0.3mX0.3m) with necessary earth work and cement concrete (1Cement : 2Sand : 4 Stone Aggregate). Write up should be trilingual (Gujrati, Hindi and English) as per approved matter and etching in nature on the 18 swg SS sheet (0.9m x 0.6m)m including dismantling the old board wherever required and carriage to the office with suitable arrangement etc. all complete as per approval of Engineer-in-charge. (Including all the materials & labour charges etc. complete as direction by site in charge)
52Towards Making soak pit 2.5 m diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. (Including all the materials & labour charges etc. complete as direction by site in charge)
53Towards providing and fixing stainless steel (Grade 304) structure as per approved design for cantilever type direction board, made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the leg in pits (0.3mX0.3mX0.4m) with necessary earth work and cement concrete (1Cement : 2 Sand : 4 Stone Aggregate). Write up should be trilingual (Gujrati, Hindi and English) as per approved matter and etching in nature on the 18 swg SS sheet (0.6m x 0.75m)m including dismantling the old board wherever required and carriage to the office with suitable arrangement etc all complete as per approval of Engineer-in-charge. (Including all the materials & labour charges etc. complete as direction by site in charge)
54Towards supply and fixing of a standard heavy-duty wall-mounted fan (typically 400mm/16-inch sweep) complete with all necessary mounting brackets, anchor fasteners/plugs, structural fixing accessories, and connection to the nearest electrical point using flexible PVC conduit and standard copper wiring. The item includes all necessary civil making-good works, drilling, testing, and balancing to ensure complete and functional operations. (Including all the materials & labour charges etc. complete as direction by site in charge)
55Towards Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand).n (Including all the materials & labour charges etc. complete as direction by site in charge)
56Towards supply, installation, testing, and commissioning of a 100 Litres Per Hour RO cum UV water purification system, and handles raw water with a TDS level of up to 2,000–3,000 ppm, Multi-stage purification including Pre-Sediment, Activated Carbon, RO membrane, and UV Sterilization,300 GPD, Corrosion-resistant Heavy Duty Stainless Steel, complete with all necessary plumbing connections, internal water supply lines, electrical connections, wiring, starters, switches, and associated structural fixing/mounting arrangements. The rate shall include the cost of all materials, hardware, labor, testing, civil making-good works, and commissioning to ensure fully functional operations complete in all respects, as per the specifications and directions of the Site Engineer-in-Charge. (Including all the materials & labour charges etc. complete as direction by site in charge)
57Towards supply, installation, testing, and commissioning of an water chiller/cooling machine suitable for a 100 Litres Per Hour RO plant with details 230 V voltage, Stainless Steel, Current 2.5 A, Cooling Capacity 40 l/hr Normal Demand 300 Glasses Per Hour Compressor Type RECIP. The scope of work includes the delivery of the chiller unit to the site; providing all necessary internal and external plumbing connections using food-grade/approved piping material (such as UPVC/CPVC); integration with the existing RO treated-water line; routing of required electrical connections, including power wiring, starters, MCBs, indicators, and switches up to the nearest distribution board and final commissioning to achieve a fully functional, leak-proof operation in all respects, as per the specifications and directions of the Site Engineer-in-Charge. (Including all the materials & labour charges etc. complete as direction by site in charge)
58Towards providing, construction and installing a drinking water fountain of approved design .The rate shall include all necessary civil works (such Brick work with 1:4 motar, PCC, plaster, 40mm sand Stone cladding etc. ) and plumbing works (including providing and laying heavy-duty CPVC water inlet pipes, connection with isolating brass ball valves, providing and laying PVC/CI waste disposal/drainpipes up to the nearest gully trap/drainage chamber, and all necessary CP brass fittings, connections, and joints). The work includes all testing, commissioning, and cleaning, completed in all respects as per the detailed drawings, specifications, and the direction of the Engineer-in-Charge. (Including all the materials & labour charges etc. complete as direction by site in charge) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56630553
AUTHORITY Government Departments
TENDER VALUE 28.16 Lakhs
LAST DATE 13-08-2026
Authority
Authority Name Archaeological Survey Of India
Work Description Tender for Execution Of Work Under (Ow) Repairing And Upgradation Of Staff Quarter And Toilet At The Adjacent Complex Of Hira Gate At Dabhoi.
Basic Detail
Tender No T/165/2026-Vadodara Circle-1891
Bidding Type Tender
Location
City Vadodara
State Gujarat
Key Dates
Publish Date 23 Jul 2026
Submission Date 13 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 28.16 Lakhs
Tender Fee Ref. Documents
EMD 70400
Exemption Available
Document List
1891.pdf
499af887-5fe7-4f7e-ad58-6f8eedd84c79.html
BOQ_965624.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.