Tender For Arm Of Support Weapon Squadron (Sws) Buildings At Nsg C Manesar For The Year 2026-27(Sh: Civil & Electrical Maintenance)
Tender Value
9.56 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
1 days left
EMD
19139
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Arm Of Support Weapon Squadron (Sws) Buildings At Nsg C Manesar For The Year 2026-27(Sh: Civil & Electrical Maintenance)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge |
| 2 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge. |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 4 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 5 | 1:6 (1 cement: 6 fine sand) |
| 6 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: |
| 7 | (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. |
| 8 | (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. |
| 9 | (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. |
| 10 | (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. |
| 11 | For the purpose of measurement the entire treated surface will be measured. |
| 12 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : |
| 13 | Using rough Kota stone |
| 14 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 15 | In cement mortar |
| 16 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 17 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 18 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 19 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. |
| 20 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 21 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 22 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 23 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 24 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 26 | One or more coats on old work. |
| 27 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : |
| 28 | 5.5 mm thick glass panes. |
| 29 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 30 | Bars upto 12 mm diameter |
| 31 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 32 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 33 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. |
| 34 | Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 35 | 12 mm average thickness. |
| 36 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 37 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 38 | Two coats. |
| 39 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 40 | Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern |
| 41 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 42 | W.C. pan with ISI marked white solid plastic seat and lid |
| 43 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 44 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 45 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 46 | 15mm nominal bore |
| 47 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 48 | Providing and fixing brass bib cock of approved quality : |
| 49 | 15 mm nominal bore |
| 50 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 51 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 52 | Of area 3 sq. metres and below |
| 53 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 54 | 15 mm to 40 mm nominal bore |
| 55 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 56 | 15 mm nominal outer dia. Pipes. |
| 57 | 20 mm nominal outer dia. Pipes. |
| 58 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 59 | (i)Single socketed pipes. |
| 60 | 75 mm diameter |
| 61 | 110 mm diameter |
| 62 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 63 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 64 | 10 litre capacity - White |
| 65 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 66 | Providing and fixing to existing door frames. |
| 67 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 68 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 69 | 250x16 mm |
| 70 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 71 | 250x10 mm |
| 72 | 200x10 mm |
| 73 | Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) |
| 74 | 125x65x2.12 mm |
| 75 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 76 | For thickness of tiles 10 mm to 25 mm |
| 77 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 78 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 79 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 80 | 125 mm |
| 81 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 82 | 150x10 mm |
| 83 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 84 | Rectangular shape 453x357 mm |
| 85 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 86 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 87 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws |
| 88 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 89 | Of area 3 sq. metres and below |
| 90 | Float glass panes |
| 91 | 4 mm thick glass pane (weight not less than 10 kg/sqm). |
| 92 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. |
| 93 | With 12 mm mild steel U beading |
| 94 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 95 | Two coats. |
| 96 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 97 | 125 mm |
| 98 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 99 | 150x10 mm |
| 100 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 101 | 150x10 mm |
| 102 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 103 | 250x16 mm |
| 104 | Correction Factor of GDT on DSR-2023 Items @ 0.973 on total of DSR rates(i.e 707854.43 x 0.973) = 688742.36 - 707854.43 = (-) 19,112.06 (Variation Amt) |
| 105 | Add for Cost index on DSR 2023 @ 4.03% on 688742.36 = 27,756.31 |
| 106 | Electrical |
| 107 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable etc. as required. |
| 108 | Group A |
| 109 | Group B |
| 110 | Group C |
| 111 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 112 | Wiring for light/ power plug with 2X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 113 | Wiring for light/ power plug with 4X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 114 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/ HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 115 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 116 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 117 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 118 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 119 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 120 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 121 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 122 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. |
| 123 | Group A |
| 124 | Group B |
| 125 | Group C |
| 126 | Rewiring for twin control light point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 127 | Supplying and drawing following size of FRLS/ HFFR PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 128 | 1 x 1.5 sq. mm |
| 129 | 2 x 1.5 sq. mm |
| 130 | 3 x 1.5 sq. mm |
| 131 | 4 x 1.5 sq. mm |
| 132 | 5 x 1.5 sq. mm |
| 133 | 6 x 1.5 sq. mm |
| 134 | 9 x 1.5 sq. mm |
| 135 | 1 x 4 sq. mm |
| 136 | 3 x 4 sq. mm |
| 137 | 6 x 4 sq. mm |
| 138 | 3 x 6 sq. mm |
| 139 | 2 x 10 sq. mm + 1 x 6 Sq.mm |
| 140 | Supplying and drawing following pair 0.5 mm dia FRLS/ HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required |
| 141 | 1 Pair |
| 142 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 143 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 144 | 20 mm |
| 145 | 25 mm |
| 146 | 32 mm |
| 147 | 40 mm |
| 148 | 50 mm |
| 149 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 150 | 5/6 A switch |
| 151 | 2 way 5/6 A switch |
| 152 | 15/16 A switch |
| 153 | 3 pin 5/6 A socket outlet |
| 154 | 6 pin 15/16 A socket outlet |
| 155 | Telephone socket outlet |
| 156 | TV antenna socket outlet |
| 157 | Bell push |
| 158 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 159 | 5/6 A switch |
| 160 | 2 way 5/6 A switch |
| 161 | 15/16 A switch |
| 162 | 3 pin 5/6 A socket outlet |
| 163 | 6 pin 15/16 A socket outlet |
| 164 | Telephone socket outlet |
| 165 | TV antenna socket outlet |
| 166 | Bell push |
| 167 | 25 amp switch |
| 168 | Computer Jack ( RJ 45) Cat6 (1 module) |
| 169 | 6 A to 32 A rating, 240 V, , \\"C\\" curve, SP modular MCB |
| 170 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 171 | Supplying and fixing two module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required. |
| 172 | Supplying and fixing one module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required. |
| 173 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 174 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 175 | 1 or 2 Module (75mmX75mm) |
| 176 | 3 Module (100mmX75mm) |
| 177 | 4 Module (125mmX75mm |
| 178 | 6 Module (200mmX75mm) |
| 179 | 8 Module (125mmX125mm) |
| 180 | 12 Module (200mmX150mm) |
| 181 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 182 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 183 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 184 | Supplying and fixing Ding Dong Door Bell, suitable for single phase, 230 V, complete as required. |
| 185 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS/ HFFR PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 186 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 187 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 188 | Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes. |
| 189 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 190 | 1 run of cable |
| 191 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable etc. as required. |
| 192 | Group C |
| 193 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 194 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 16 A modular socket outlet and 16 A/25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 195 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 196 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 197 | 12 way , Double door |
| 198 | 16 way, Double door |
| 199 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 200 | Single pole |
| 201 | Double pole |
| 202 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 203 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 204 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 205 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 206 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 207 | For 8 way, Double door SPN MCBDB |
| 208 | For 10 way/ 12 way, Double door SPN MCBDB |
| 209 | For 14 way/16 way, Double door SPN MCBDB |
| 210 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 211 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required. |
| 212 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 213 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75°C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 214 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 215 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge |
| 216 | Supplying and fixing two module bell/ chime on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 217 | Supply and installation of 400 mm sweep, 220 V, wall mounted fan along with speed regulator unit for speed control, on the existing wall, including connection, testing, commissioning etc. as required. (Make: Crompton/Havells/Orient/Usha/Bajaj/Almonard) |
| 218 | Supply, installation, testing and commissioning of wall-mounted light fixture complete with B22 base, metal base in Nickel / Brass finishing with diffuser and 9 watts LED blub etc., as required directly on the wall, including connections etc. as required. ( Havells FLORETINE WL 1 LS or similar in Wipro/Philips/Jaquar/LT as approved by the Engineer -in- charge) |
| 219 | Supplying and fixing 3 mm thick phenolic laminated sheet cover on existing switch Box / metal box with Al. Alloy/ cadmium/ zinc plated screws and washers, including cutting the laminated sheet to required shape and size etc., complete as required. |
| 220 | Supply and installation of 150 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 270 CMH and a power consumption not exceeding 28 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard) |
| 221 | Supply and installation of 200 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 500 CMH and a power consumption not exceeding 30 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard) |
| 222 | Supply and installation of 250 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 750 CMH and a power consumption not exceeding 40 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard) |
| 223 | Supplying and installation of 300 mm sweep, 1400 RPM, heavy-duty, single-phase, metallic exhaust fan conforming to IS:2312-1967 in the existing opening, including making good the damage, including connections, earthing, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer’s warranty (Havells / Crompton / Orient / Usha / Almonard). |
| 224 | Making holes of the required size and shape in a brick masonry wall for installation of the following size exhaust fan, including making good the wall by plastering and finishing with the matching surface, etc., complete as per the direction of the engineer-in-charge. |
| 225 | 150 mm sweep. |
| 226 | 200 mm sweep. |
| 227 | 225 mm/ 230 mm sweep. |
| 228 | 250 mm sweep. |
| 229 | Cutting a hole of the required size and shape on the window or ventilator glass pane for the installation of an exhaust fan of size up to 150 mm sweep, etc., complete as per the direction of the engineer-in-charge. |
| 230 | Supply and fixing of 12 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts, etc. as required. |
| 231 | Supplying and fixing suitable size GI box in recess, including providing and fixing of 2/3 Module LED Foot light / skirting light, including connection etc. as required. |
| 232 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F. ≥ 0.95, IP20, CRI ≥ 80 , Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. |
| 233 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 234 | 18- 22 watt |
| 235 | 40 watt |
| 236 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, with a minimum system lumen output of 1000 lumen and with a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. |
| 237 | Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required |
| 238 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) ≤ 19 Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. |
| 239 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim. |
| 240 | 5 - 7 watt |
| 241 | 12 - 15 watt |
| 242 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.. |
| 243 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm) |
| 244 | CRCA Sheet Body (Thickness ≥ 0.50 mm) |
| 245 | 36 watt |
| 246 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, |
| 247 | Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 248 | 45 watt |
| 249 | Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required. |
| 250 | 300 mm |
| 251 | 380 mm |
| 252 | Providing and fixing 3 mm thick PVC/ phenolic laminated round sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required. |
| 253 | Providing and fixing 3 mm thick PVC / phenolic laminated round sheet cover on the existing junction box with two screws, etc., as required. |
| 254 | Supply, installation, testing, and commissioning of outdoor type 3-watt IP 65 LED foot light/ step light in Die cast aluminium housing and Polycarbonate diffuser, complete with connection, etc., as required. (Jaquar LFTL01S003XW or similar in Philips / Wipro /LT/ Havells) |
| 255 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 256 | 40 A Double pole |
| 257 | 63 A Double pole |
| 258 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 259 | 40 A Triple pole and neutral |
| 260 | 63 A Triple pole and neutral |
| 261 | Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, in recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required including making good the damage to match the adjacent surface, etc., as required.. (But without MCB/RCCB/Isolator) |
| 262 | 6 to 16 way, MCB DB |
| 263 | Fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 264 | Single pole |
| 265 | Single pole and neutral |
| 266 | Double pole |
| 267 | Triple pole |
| 268 | Triple pole and neutral |
| 269 | Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM)i) 20 mm |
| 270 | Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM)i) 25 mm |
| 271 | Supplying and fixing of 23 mm x 1.5 mm S.S./G.I. saddles on the following sizes of existing PVC or steel conduit, cable, pipe, etc., as required (Astral, Prayag, Ashirvad, Finolex, or as approved by the engineer-in-charge)i) 50 mm |
| 272 | Rewinding of following size ceiling fan / exhaust fan/ Wall fan motor including complete removal of existing burnt out winding and rewinding of the fan with suitable size enameled copper wire, including sleeving, suitable insulation materials, varnishing etc., complete with dismantling and reassembling after repair, including connection testing etc. as required. Removed winding wire shall be retained by the contractor and suitably credited with its value and net value to be quoted. |
| 273 | 1200mm Sweep ceiling fan |
| 274 | 1400mm Sweep ceiling fan |
| 275 | Wall Fan upto 400 mm |
| 276 | Rewinding of stator winding of following size exhaust fans with suitable size enameled copper wire (as per manufacturer specification) including slaving of stator suitable insulation materials ie “E” class varnish complete with dismantling and reassembling after repair i/c connection testing etc as required (Brunt copper wire will be retained by the contractor). |
| 277 | 300mm / 380 mm exhaust fan |
| 278 | 450 mm exhaust fan |
| 279 | 600mm exhaust fan |
| 280 | Providing and replacing ball bearing in following size ceiling fan/exhaust fan, including removing old ball-bearing, installing new ball bearing and testing the fan, etc., as required. (Scrap material will be retained by the contractor). (Both side shield ball bearing of SKF/ NBC /TATA ) |
| 281 | 1200mm Sweep ceiling fan. |
| 282 | 1400mm Sweep ceiling fan. |
| 283 | 300mm/ 380 mm exhaust fan |
| 284 | 450 mm exhaust fan. |
| 285 | 600 mm exhaust fan. |
| 286 | Providing and replacing 2.5 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor). |
| 287 | Providing and replacing the 4 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor). |
| 288 | Reconditioning of the oversized bush /bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ wall-mounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor. |
| 289 | Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan. All the scrap material should be retained by the contractor. |
| 290 | Providing and fixing PVC clamp with connector for the ceiling fan capacitor in the existing ceiling fan, including connection, testing, etc., as required, including credit for the old PVC clamp, which will be retained by the contractor. |
| 291 | Supplying, installation testing and commissioning of BEE 5 star rating, 25 litres capacity water storage heater, with protection against over heating, Multifunction Safety Valve and external adjustable thermostat, with 16 A, 240 V, plug top and 02 nos flexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make: Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty) |
| 292 | Supplying and fixing PRCD (Portable Residual Current Device) Plug top, 16 A 30 mA rating including connection etc. as required. |
| 293 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 6 pin 15/16 A modular socket outlet and 2 nos. 15/16 A modular switch, connections etc. as required. |
| 294 | Supplying and fixing Plug top following rating including connection etc. as required. |
| 295 | 16 A, three pin, Plug top ISI marked |
| 296 | 6 A, three pin, Plug top ISI marked |
| 297 | Supplying and fixing Bakelite Sheet of following size with screw in the existing looping box/ panel including cutting the sheet to required shape and size complete etc as reqd. |
| 298 | 6 mm thick |
| 299 | Supplying and laying of G.I. pipe of 50 mm dia.(nominal), medium class, ISI marked in wall / floor including cutting chase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable) |
| 300 | Providing and fixing Din-rail 35 mm x 7.5 mm on exisitng panel etc., as required. i) Din-rail 35 mm x 7.5 mm |
| 301 | Supplying and fixing 2 way, 60 Amp, two way connectors on the existing looping box / Panel board including connection etc as required. |
| 302 | Supplying and fixing modular 20 A Motor starter on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 303 | Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required. |
| 304 | Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store. |
| 305 | Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required. |
| 306 | Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store. |
| 307 | Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 308 | Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 309 | Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required. |
| 310 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Above 25 mm conduits. |
| 311 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Up to 25 mm conduit. |
| 312 | Less credit for the unserviciable items dismantled items during execution of the work. |
| 313 | Assorted PIANO Type Switches |
| 314 | Assorted PIANO Type Sockets |
| 315 | Assorted Bell push/PIANO Type |
| 316 | Assorted Call bell buzzer single phase |
| 317 | Assorted Brass batten/ angle holder/Brass Bracket |
| 318 | Assorted Fan regulator/resistance type |
| 319 | Assorted Telephone Socket outlet |
| 320 | Assorted T.V. Socket outlet |
| 321 | Assorted Capacitor, 3.15/2.50/2.25 mfd |
| 322 | Assorted 1200/1400 mm sweep ceiling Fan with blades |
| 323 | Assorted Fresh Air/ Exhaust FAN PVC up to 250 mm sweep. |
| 324 | Assorted Exhaust fan metallic up to 300 mm sweep. |
| 325 | Assorted Exhaust fan metallic above 300 mm sweep and up to 450 mm sweep. |
| 326 | Assorted Wall Bracket Fittings PVC |
| 327 | Assorted Wall Bracket Fittings metallic |
| 328 | Assorted fluorescent Light Fittings |
| 329 | Assorted Bulk Head Fittings |
| 330 | less credit for the dismantled insulated copper conductor cable/ wires from light points/ circuit/ submain/power circuit wiring,. |
| 331 | less credit for the dismantled insulated aluminium conductor cable / wire from light points/ circuit/ submain/power circuit wiring. |
| 332 | Assorted metal switch box. |
| 333 | Assorted MCB DB SPN with out MCBs |
| 334 | Assorted MCB DB TPN with out MCBs |
| 335 | Assorted MCB SP |
| 336 | Assorted MCB DP |
| 337 | Assorted MCB TP AND TP&N Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender