Defence Government Departments Closing in 1 days TDR #56630530

Tender For Arm Of Support Weapon Squadron (Sws) Buildings At Nsg C Manesar For The Year 2026-27(Sh: Civil & Electrical Maintenance)

Issued by Government Departments · Gurgaon, Haryana
Tender Value
9.56 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
1 days left
EMD
19139
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Arm Of Support Weapon Squadron (Sws) Buildings At Nsg C Manesar For The Year 2026-27(Sh: Civil & Electrical Maintenance)

BOQ

Name of Work:- ARM of Support Weapon Squadron (SWS) Buildings at NSG C Manesar for the Year 2026-27(SH: Civil & Electrical Maintenance)
Sl. No. Item Description
1Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge
2Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge.
3Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
415 mm cement plaster on the rough side of single or half brick wall of mix :
51:6 (1 cement: 6 fine sand)
6Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:
7(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.
8(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.
9(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
10(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.
11For the purpose of measurement the entire treated surface will be measured.
12Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
13Using rough Kota stone
14Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge..
15In cement mortar
16Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
17Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
181:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
19Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level.
20Thermo-Mechanically Treated bars of grade Fe-500D or more.
21Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
22Finishing walls with Acrylic Smooth exterior paint of required shade :
23Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).
24Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
25Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
26One or more coats on old work.
27Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :
285.5 mm thick glass panes.
29Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
30Bars upto 12 mm diameter
31Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
32SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
33Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.
34Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
3512 mm average thickness.
36Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
37Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
38Two coats.
39Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
40Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
41Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
42W.C. pan with ISI marked white solid plastic seat and lid
43Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
44White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
45Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :
4615mm nominal bore
47Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
48Providing and fixing brass bib cock of approved quality :
4915 mm nominal bore
50Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
51Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
52Of area 3 sq. metres and below
53Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
5415 mm to 40 mm nominal bore
55Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
5615 mm nominal outer dia. Pipes.
5720 mm nominal outer dia. Pipes.
58Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
59(i)Single socketed pipes.
6075 mm diameter
61110 mm diameter
62Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
63Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
6410 litre capacity - White
65Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
66Providing and fixing to existing door frames.
6730 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
68Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
69250x16 mm
70Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
71250x10 mm
72200x10 mm
73Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378)
74125x65x2.12 mm
75Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
76For thickness of tiles 10 mm to 25 mm
77Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
78Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
79Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
80125 mm
81Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
82150x10 mm
83Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
84Rectangular shape 453x357 mm
85Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
86600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
8725 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws
88Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
89Of area 3 sq. metres and below
90Float glass panes
914 mm thick glass pane (weight not less than 10 kg/sqm).
92Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.
93With 12 mm mild steel U beading
94Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
95Two coats.
96Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
97125 mm
98Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
99150x10 mm
100Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378)
101150x10 mm
102Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
103250x16 mm
104Correction Factor of GDT on DSR-2023 Items @ 0.973 on total of DSR rates(i.e 707854.43 x 0.973) = 688742.36 - 707854.43 = (-) 19,112.06 (Variation Amt)
105Add for Cost index on DSR 2023 @ 4.03% on 688742.36 = 27,756.31
106Electrical
107Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable etc. as required.
108Group A
109Group B
110Group C
111Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
112Wiring for light/ power plug with 2X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable for loop earthing as required.
113Wiring for light/ power plug with 4X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable for loop earthing as required.
114Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/ HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1152 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1162 X 4 sq. mm + 1 X 4 sq. mm earth wire
1172 X 6 sq. mm + 1 X 6 sq. mm earth wire
1182 X 10 sq. mm + 1 X 6 sq. mm earth wire
1194 X 4 sq. mm + 2 X 4 sq. mm earth wire
1204 X 6 sq. mm + 2 X 6 sq. mm earth wire
1214 X 10 sq. mm + 2 X 6 sq. mm earth wire
122Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
123Group A
124Group B
125Group C
126Rewiring for twin control light point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
127Supplying and drawing following size of FRLS/ HFFR PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required
1281 x 1.5 sq. mm
1292 x 1.5 sq. mm
1303 x 1.5 sq. mm
1314 x 1.5 sq. mm
1325 x 1.5 sq. mm
1336 x 1.5 sq. mm
1349 x 1.5 sq. mm
1351 x 4 sq. mm
1363 x 4 sq. mm
1376 x 4 sq. mm
1383 x 6 sq. mm
1392 x 10 sq. mm + 1 x 6 Sq.mm
140Supplying and drawing following pair 0.5 mm dia FRLS/ HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required
1411 Pair
142Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
143Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
14420 mm
14525 mm
14632 mm
14740 mm
14850 mm
149Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
1505/6 A switch
1512 way 5/6 A switch
15215/16 A switch
1533 pin 5/6 A socket outlet
1546 pin 15/16 A socket outlet
155Telephone socket outlet
156TV antenna socket outlet
157Bell push
158Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1595/6 A switch
1602 way 5/6 A switch
16115/16 A switch
1623 pin 5/6 A socket outlet
1636 pin 15/16 A socket outlet
164Telephone socket outlet
165TV antenna socket outlet
166Bell push
16725 amp switch
168Computer Jack ( RJ 45) Cat6 (1 module)
1696 A to 32 A rating, 240 V, , \\"C\\" curve, SP modular MCB
170Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
171Supplying and fixing two module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required.
172Supplying and fixing one module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required.
173Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
174Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1751 or 2 Module (75mmX75mm)
1763 Module (100mmX75mm)
1774 Module (125mmX75mm
1786 Module (200mmX75mm)
1798 Module (125mmX125mm)
18012 Module (200mmX150mm)
181Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
182Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
183Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
184Supplying and fixing Ding Dong Door Bell, suitable for single phase, 230 V, complete as required.
185Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS/ HFFR PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.
186Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
187Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
188Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes.
189Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
1901 run of cable
191Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable etc. as required.
192Group C
193Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.
194Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 16 A modular socket outlet and 16 A/25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
195Supplying and fixing PVC batten/ angle holder including connections etc. as required.
196Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
19712 way , Double door
19816 way, Double door
199Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
200Single pole
201Double pole
202Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
203Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
204Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
205Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.
206Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
207For 8 way, Double door SPN MCBDB
208For 10 way/ 12 way, Double door SPN MCBDB
209For 14 way/16 way, Double door SPN MCBDB
210Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
211Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.
212Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
213Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75°C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
2141200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
215Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge
216Supplying and fixing two module bell/ chime on the existing modular plate switch box including connections but excluding modular plate etc. as required.
217Supply and installation of 400 mm sweep, 220 V, wall mounted fan along with speed regulator unit for speed control, on the existing wall, including connection, testing, commissioning etc. as required. (Make: Crompton/Havells/Orient/Usha/Bajaj/Almonard)
218Supply, installation, testing and commissioning of wall-mounted light fixture complete with B22 base, metal base in Nickel / Brass finishing with diffuser and 9 watts LED blub etc., as required directly on the wall, including connections etc. as required. ( Havells FLORETINE WL 1 LS or similar in Wipro/Philips/Jaquar/LT as approved by the Engineer -in- charge)
219Supplying and fixing 3 mm thick phenolic laminated sheet cover on existing switch Box / metal box with Al. Alloy/ cadmium/ zinc plated screws and washers, including cutting the laminated sheet to required shape and size etc., complete as required.
220Supply and installation of 150 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 270 CMH and a power consumption not exceeding 28 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard)
221Supply and installation of 200 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 500 CMH and a power consumption not exceeding 30 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard)
222Supply and installation of 250 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 750 CMH and a power consumption not exceeding 40 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard)
223Supplying and installation of 300 mm sweep, 1400 RPM, heavy-duty, single-phase, metallic exhaust fan conforming to IS:2312-1967 in the existing opening, including making good the damage, including connections, earthing, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer’s warranty (Havells / Crompton / Orient / Usha / Almonard).
224Making holes of the required size and shape in a brick masonry wall for installation of the following size exhaust fan, including making good the wall by plastering and finishing with the matching surface, etc., complete as per the direction of the engineer-in-charge.
225150 mm sweep.
226200 mm sweep.
227225 mm/ 230 mm sweep.
228250 mm sweep.
229Cutting a hole of the required size and shape on the window or ventilator glass pane for the installation of an exhaust fan of size up to 150 mm sweep, etc., complete as per the direction of the engineer-in-charge.
230Supply and fixing of 12 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts, etc. as required.
231Supplying and fixing suitable size GI box in recess, including providing and fixing of 2/3 Module LED Foot light / skirting light, including connection etc. as required.
232Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F. ≥ 0.95, IP20, CRI ≥ 80 , Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.
233Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
23418- 22 watt
23540 watt
236Supply, installation, testing, and commissioning of integrated LED Batten luminaire, with a minimum system lumen output of 1000 lumen and with a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
237Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required
238Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) ≤ 19 Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.
239Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.
2405 - 7 watt
24112 - 15 watt
242Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard..
243Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm)
244CRCA Sheet Body (Thickness ≥ 0.50 mm)
24536 watt
246Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5,
247Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
24845 watt
249Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required.
250300 mm
251380 mm
252Providing and fixing 3 mm thick PVC/ phenolic laminated round sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required.
253Providing and fixing 3 mm thick PVC / phenolic laminated round sheet cover on the existing junction box with two screws, etc., as required.
254Supply, installation, testing, and commissioning of outdoor type 3-watt IP 65 LED foot light/ step light in Die cast aluminium housing and Polycarbonate diffuser, complete with connection, etc., as required. (Jaquar LFTL01S003XW or similar in Philips / Wipro /LT/ Havells)
255Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
25640 A Double pole
25763 A Double pole
258Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25940 A Triple pole and neutral
26063 A Triple pole and neutral
261Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, in recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required including making good the damage to match the adjacent surface, etc., as required.. (But without MCB/RCCB/Isolator)
2626 to 16 way, MCB DB
263Fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
264Single pole
265Single pole and neutral
266Double pole
267Triple pole
268Triple pole and neutral
269Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM)i) 20 mm
270Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM)i) 25 mm
271Supplying and fixing of 23 mm x 1.5 mm S.S./G.I. saddles on the following sizes of existing PVC or steel conduit, cable, pipe, etc., as required (Astral, Prayag, Ashirvad, Finolex, or as approved by the engineer-in-charge)i) 50 mm
272Rewinding of following size ceiling fan / exhaust fan/ Wall fan motor including complete removal of existing burnt out winding and rewinding of the fan with suitable size enameled copper wire, including sleeving, suitable insulation materials, varnishing etc., complete with dismantling and reassembling after repair, including connection testing etc. as required. Removed winding wire shall be retained by the contractor and suitably credited with its value and net value to be quoted.
2731200mm Sweep ceiling fan
2741400mm Sweep ceiling fan
275Wall Fan upto 400 mm
276Rewinding of stator winding of following size exhaust fans with suitable size enameled copper wire (as per manufacturer specification) including slaving of stator suitable insulation materials ie “E” class varnish complete with dismantling and reassembling after repair i/c connection testing etc as required (Brunt copper wire will be retained by the contractor).
277300mm / 380 mm exhaust fan
278450 mm exhaust fan
279600mm exhaust fan
280Providing and replacing ball bearing in following size ceiling fan/exhaust fan, including removing old ball-bearing, installing new ball bearing and testing the fan, etc., as required. (Scrap material will be retained by the contractor). (Both side shield ball bearing of SKF/ NBC /TATA )
2811200mm Sweep ceiling fan.
2821400mm Sweep ceiling fan.
283300mm/ 380 mm exhaust fan
284450 mm exhaust fan.
285600 mm exhaust fan.
286Providing and replacing 2.5 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor).
287Providing and replacing the 4 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor).
288Reconditioning of the oversized bush /bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ wall-mounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor.
289Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan. All the scrap material should be retained by the contractor.
290Providing and fixing PVC clamp with connector for the ceiling fan capacitor in the existing ceiling fan, including connection, testing, etc., as required, including credit for the old PVC clamp, which will be retained by the contractor.
291Supplying, installation testing and commissioning of BEE 5 star rating, 25 litres capacity water storage heater, with protection against over heating, Multifunction Safety Valve and external adjustable thermostat, with 16 A, 240 V, plug top and 02 nos flexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make: Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty)
292Supplying and fixing PRCD (Portable Residual Current Device) Plug top, 16 A 30 mA rating including connection etc. as required.
293Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 6 pin 15/16 A modular socket outlet and 2 nos. 15/16 A modular switch, connections etc. as required.
294Supplying and fixing Plug top following rating including connection etc. as required.
29516 A, three pin, Plug top ISI marked
2966 A, three pin, Plug top ISI marked
297Supplying and fixing Bakelite Sheet of following size with screw in the existing looping box/ panel including cutting the sheet to required shape and size complete etc as reqd.
2986 mm thick
299Supplying and laying of G.I. pipe of 50 mm dia.(nominal), medium class, ISI marked in wall / floor including cutting chase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable)
300Providing and fixing Din-rail 35 mm x 7.5 mm on exisitng panel etc., as required. i) Din-rail 35 mm x 7.5 mm
301Supplying and fixing 2 way, 60 Amp, two way connectors on the existing looping box / Panel board including connection etc as required.
302Supplying and fixing modular 20 A Motor starter on the existing modular plate switch box including connections but excluding modular plate etc. as required.
303Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required.
304Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store.
305Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required.
306Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store.
307Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.
308Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.
309Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required.
310Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Above 25 mm conduits.
311Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Up to 25 mm conduit.
312Less credit for the unserviciable items dismantled items during execution of the work.
313Assorted PIANO Type Switches
314Assorted PIANO Type Sockets
315Assorted Bell push/PIANO Type
316Assorted Call bell buzzer single phase
317Assorted Brass batten/ angle holder/Brass Bracket
318Assorted Fan regulator/resistance type
319Assorted Telephone Socket outlet
320Assorted T.V. Socket outlet
321Assorted Capacitor, 3.15/2.50/2.25 mfd
322Assorted 1200/1400 mm sweep ceiling Fan with blades
323Assorted Fresh Air/ Exhaust FAN PVC up to 250 mm sweep.
324Assorted Exhaust fan metallic up to 300 mm sweep.
325Assorted Exhaust fan metallic above 300 mm sweep and up to 450 mm sweep.
326Assorted Wall Bracket Fittings PVC
327Assorted Wall Bracket Fittings metallic
328Assorted fluorescent Light Fittings
329Assorted Bulk Head Fittings
330less credit for the dismantled insulated copper conductor cable/ wires from light points/ circuit/ submain/power circuit wiring,.
331less credit for the dismantled insulated aluminium conductor cable / wire from light points/ circuit/ submain/power circuit wiring.
332Assorted metal switch box.
333Assorted MCB DB SPN with out MCBs
334Assorted MCB DB TPN with out MCBs
335Assorted MCB SP
336Assorted MCB DP
337Assorted MCB TP AND TP&N Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56630530
AUTHORITY Government Departments
TENDER VALUE 9.56 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name National Security Guard
Work Description Tender for Arm Of Support Weapon Squadron (Sws) Buildings At Nsg C Manesar For The Year 2026-27(Sh: Civil & Electrical Maintenance)
Basic Detail
Tender No 29/CS/2026-27/NSG
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 24 Jul 2026
Submission Date 01 Aug 2026
Open Date 03 Aug 2026
Finance
Tender Value 9.56 Lakhs
Tender Fee Ref. Documents
EMD 19139
Exemption Not Available
Document List
5fd9aedc-77c8-40f6-9627-8f78f57ca22e.html
BOQ_965640.xls
Tendernotice_1.pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

5fd9aedc-77c8-40f6-9627-8f78f57ca22e.html

xls

BOQ_965640.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders