Rural Development Government Departments Closing in 9 days TDR #56630333

Tender For Construction Of Long Span Bridge Across Apaw River On Road From Pwd Road To Glotong In Hayuliang-Goiliang Block Of Anjaw District (A.P) Under Vvp (Span-50.00M).

Issued by Government Departments · Papum Pare, Arunachal Pradesh
Tender Value
8.78 Crore
Estimated cost
Bid Submission
08 Aug 2026
9 days left
EMD
17.57 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Papum Pare → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Construction Of Long Span Bridge Across Apaw River On Road From Pwd Road To Glotong In Hayuliang-Goiliang Block Of Anjaw District (A.P) Under Vvp (Span-50.00M).

BOQ

Name of Work:- Construction of Long Span Bridge across APAW River on Road from PWD Road to Glotong in Hayuliang-Goiliang Block of Anjaw District (A.P) under VVP (Span-50.00m).
Sl. No. Item Description
1Confirmity SS I
2(i) Conduct of Bore Hole Testing, as per IS:54:2000 sinking of 150 mm dia Bore Hole into the Sub Surface and conduct of all necessary tests and submission of report with recommendation in three copies.
3Foundation (Excavation for Structures)
4Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)II) Ordinary rock (not requiring blasting)B Mechanical Means(iii) c Depth upto 6 m ( without de-watering) (i) Ordinary Soil
5(ii) Ordinary Rock (not requring blasting)
6(IV) Hard rock (blasting prohibited)
7Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15
8Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M30. With Batching Plant, Transit Mixer and Concrete Pump
9Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and Technical Specifications
10Sub Structure
11Plain/Reinforced Cement Concretein Sub structure complete as per drawing Technical Specifications. RCC Grade M30, Height 5m to 10m. With Batching Plant, Transit Mixer and Concrete Pump.
12Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawing and Technical Specifications
13Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications
14Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
15Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification. Granular material
16Supply, fitting and fixing position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 Part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete as per drawing and approved Technical Specifications.
17Super Structure
18Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M 30, height up to 5m. Using Batching Plant, Transit Mixer and Concrete Pump - for deck slab
19Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications -Fe500
20Provision of Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-35 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified..........a) M 35 grade concrete crash barrier
21Type B,\\"THRIE\\" Metal Beam Crash Barrier: Providing and erecting a \\"Thrie\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a space of channel section 150 x 75 x 5 mm, 546 mm long complete as per clause 810.
22Drainage spouts complete as per drawing and technical specifications
23PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
24Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification
25Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
26Strip Seal Expansion Joint: Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.
27Painting on concrete surface: Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm.
28Supply and fabrication of steel work at fabricators workshop comprising of main griders, cross griders connecting plates, stringers,stiffening plates etc. from steel plates and structural steel of specified grades as per approved drawing including straightening, decaling, degreasing cutting to size and shape drilling welding and grinding supply of all MS/HTS shop or site bolts nuts & washers, holding down bolts and nuts etc. trail assembling at workshop one priming coat of shop paint with red lead paint conforming to IS-102 with all labour material cost of paintsconsumables stacking in protected condition etc omplete as per specification and as directed by the Engineer in charge (Carriage cost from fabricator workshop to actual bridge site will be paid separately)
29Cost of Haulage including loading and unloading.Carriage of Structural steel from source to site of work by mechanical transport including unloading and stacking as directed by the Engineer In-Charge.
30Taking delivery of fabricated steel work from stacks at site as necessary assembling and erection at site necessary assemblen and erection of fabricated steel structure to proper line level and camber as per approved drawing complete in all respect including transportation and handling supply of all fastener, painting of all exposed surfaces of steel work after erection with one coat or red loead conforming to IS-102 and two coats Aluminium paint to IS-2339, grouting of anchor bolts in position including all labour consumables material machinery tools and tackles complete as per specification and as directed by the Engineer in-charge
31Supply Tension rod Suspender M56 Grade CS460 with bar dia 53mm and length as specified including all accessories subh as Fork assembly, Turn buckle. Lock cover etc, as required
32Load Testing of Super structure of bridge after completion in all respect using static loading method to determine accpectance criteria of design as per IRC:SP:51-2015 complete as per direction of Engineer- In-Charge.
33Routine Maintenance
34First Year
35Second Year
36Third Year
37Fourth Year
38Fifth Year Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56630333
AUTHORITY Government Departments
TENDER VALUE 8.78 Crore
LAST DATE 08-08-2026
Authority
Authority Name rural works department
Work Description Tender For Construction Of Long Span Bridge Across Apaw River On Road From Pwd Road To Glotong In Hayuliang-Goiliang Block Of Anjaw District (A.P) Under Vvp (Span-50.00M).
Basic Detail
Tender No AR/16/02/788 (E)
Bidding Type Tender
Location
City Papum Pare
State Arunachal Pradesh
Key Dates
Publish Date 24 Jul 2026
Submission Date 08 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 8.78 Crore
Tender Fee 15000
EMD 17.57 Lakhs
Exemption Not Available
Document List
62d898c3-76e6-4750-8557-8f3cc4f8ef4d.html
BOQ_233932.xls
SBD.pdf
Tendernotice_1.pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

62d898c3-76e6-4750-8557-8f3cc4f8ef4d.html

xls

BOQ_233932.xls

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders