Tender For Replacement Of 08 Nos Of Old Split And Window Air Conditioner Machines At Cnc, Copa, Dmm And Dmc Labs Of Iti Tollygunge
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Aug 2026
6 days left
EMD
13039
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of 08 Nos Of Old Split And Window Air Conditioner Machines At Cnc, Copa, Dmm And Dmc Labs Of Iti Tollygunge
BOQ
| Sl. No. | Item Description |
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. (Make:- O General/Mitsubishi Heavy Duty/Daikin/Mitsubishi Electric/Hitachi/ Bluestar/Carrier/Voltas or as approved by EIC) |
| 2 | Cooling Capacity- 6.1 kW (Minimum) , Minimum ISEER - 5.0, BEE level - 4-Star(min) |
| 3 | Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature). The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. (Make:- O General/Mitsubishi Heavy Duty/Daikin/Mitsubishi Electric/Hitachi/ Bluestar/Carrier/Voltas or as approved by EIC) |
| 4 | Cooling Capacity- 5.0 kW (Minimum) , Minimum ISEER - 3.5, BEE level - 4-Star(min) |
| 5 | S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of above AC machines. |
| 6 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above said AC, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (Make- Approved by EIC) |
| 7 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 8 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 9 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines. |
| 10 | 2.5 sqmm, 3/4 core copper cable (FRLS type) (Make- Polycab/Gloster/Finolex/Havells /RR Kabel as Approved by EIC) |
| 11 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make- Supreme / Oriplast) |
| 12 | Dismantling existing old Split/window type AC machines etc with owns tools & takles and handed over to authority as directed by EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender