Housing Urban and Rular Development Government Departments Closing in 7 days TDR #56629794

Tender For Arrangement Of Air Conditioner And Along With Necessary Electrical Installation Work For The Corridor Portion Of Lower Basement Of Tertiary Cancer Care Centre(Tccc) Under Burdwan Medical College, Purba Bardhaman

Issued by Government Departments · Purba Bardhaman, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Aug 2026
7 days left
EMD
9000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Purba Bardhaman → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Arrangement Of Air Conditioner And Along With Necessary Electrical Installation Work For The Corridor Portion Of Lower Basement Of Tertiary Cancer Care Centre(Tccc) Under Burdwan Medical College, Purba Bardhaman

BOQ

Name of Work:- Arrangement of Air conditioner and along with necessary Electrical Installation Work for the corridor portion of Lower Basement of Tertiary Cancer care Centre(TCCC) under Burdwan Medical College, Purba Bardhaman
Sl. No. Item Description
1S&drawing 1.1 kv single core stranded FR PVC insulated &unsheated single core stranded cupper wire (Mk.Polycab/RR Kabel/Hevells)of the following sizes prelaid poly pipe. & by the Gifish wire & making necy connection as required.
2b) 2X 56/0.3( 4 sqmm) + 1 X 36/0.3( 2.5 sqmm) as ECC ( From HTPN DB to Power Plug/AC )
3Supplying and fixing PVC Rigid Conduit 'FR' [Precision MMS Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
4a) 20 mm size
5b) 25 mm size
6Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
7i. 2.5 sq.mm.
8ii. 4 sq.mm.
9EI work for AC
10Supply & Fixing 240 V, 25 A, Modular type starter (Mk. Legrand/Cabtree/ wipro as per direction of EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
11Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Mk. Legrand/Cabtree/ wipro as per direction of EIC) and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
12Supply of 240 V timer DB with suitable size sheet steel enclose double door, phosphatised powder coated, neutral bar , din rail with IP-43 protection comprised with 1 no. 32A DP MCB (‘C’ Curve, 10KA), 1 no. 24 hours Analog programmable timer switch (min 15 min interval setting) and 1 no. 32A AC-3 power contactor, 1 no. out going stud complete with internal wiring by 1.1 kV grade 4 sq mm. FR PVC insulated copper wire incl. 1 no auto /manual by pass troggle switch and provision for earthing attachment incl. 4 nos LED indicating light for running condition with locking arrangement (for controlling 1 no AC machine ) [Make:- L&T /Cabtree/Siemens]
13Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.For First Floort.
14Air Conditioning work
15Supplying and delivery of following size Un-Armoured cables XLPE insulated are designed for 1.1 kV Stranded copper conductor and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.)( Make:- Polycab/Finolex/ RR Kabel)
164 core 2.5 sqmm
173 core 4.0 sqmm
18Supply & installation of 25 mm u-PVC Drain Pipe Line (25 mm /32 mm OD,HD 1 mm thick ) of the following size with including Tee, bend,plug, socket etc. as required and with proper supports & brackets as per direction of E.I.C. (Make: Suprime/Oriplast)
19Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB.
20The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations,inclusing Metal Brackets, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.
21BEE STAR RATING:- 2 STARCOMPRESSOR TYPE:-SUPER TROPICAL- RETURN COOLED ROTARYPOWER SOURCE:-1 PHASE, 220/230 V, 50 HZMAXIMUN COOLING CAPACITY:- TON 2.2,WATTS 7700,BTU/h 26272BEE RATED EER / COP: W / w 3.72CURRENT ( MINIMUM – MAXIMUM ) 8.0 – 9.2 AAIR FLOW ( CMH ):- 1450 m /hrSOUND LEVEL ( H /M/ L ) INDOOR UNIT in Db: 46/42/39SPECIAL FILTER INDOOR UNIT: Enzyme + Photocatalytic Deodorizing Filter + Anit – BacterialDC FAN MOTOR SPEED INDOOR UNIT Auto / Power / High /Med /Low/dryREFRIGERANT:R410AREFRIGERANT PIPING:-LIQUID LINE 6.35 ( 1 / 4″ ) mm, GAS LINE 15.88( 5 / 8″ )mm(Make- Mitsubishi Heavy Model SRK 25 CSS-S6 /Mitsubishi Electric/ O-General as per direction of EIC)
22Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
236.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
2415.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
25Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. Please Enable Macros to View BoQ information
26Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56629794
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 05-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Arrangement Of Air Conditioner And Along With Necessary Electrical Installation Work For The Corridor Portion Of Lower Basement Of Tertiary Cancer Care Centre(Tccc) Under Burdwan Medical College, Purba Bardhaman
Basic Detail
Tender No WBPWD/AE/BMCESD/NIeQ-02/26-27
Bidding Type Tender
Location
City Purba Bardhaman
State West Bengal
Key Dates
Publish Date 23 Jul 2026
Submission Date 05 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 9000
Exemption Not Available
Document List
3220e53b-22e5-4c92-8108-2b9a3a8bc2b8.html
BOQ_5087405.xls
Tendernotice_1 (16).pdf
WBF-2911.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

3220e53b-22e5-4c92-8108-2b9a3a8bc2b8.html

xls

BOQ_5087405.xls

pdf

Tendernotice_1 (16).pdf

pdf

WBF-2911.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders