Water Resources and Irrigation Government Departments Closing in 2 days TDR #56629540

Tender For Delhi Village Development Works In Nct Of Delhi.Sub Work :- Improvement, Repair And Construction Of Hall In Existing Vyayamshala At Village Kair In Ac-35.

Issued by Government Departments · Delhi, Delhi
Tender Value
1.32 Crore
Estimated cost
Bid Submission
29 Jul 2026
2 days left
EMD
2.64 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Delhi Village Development Works In Nct Of Delhi.Sub Work :- Improvement, Repair And Construction Of Hall In Existing Vyayamshala At Village Kair In Ac-35.

BOQ

Name of Work:- Delhi Village Development Works in NCT of Delhi.Sub Work :- Improvement, Repair and Construction of Hall in Existing Vyayamshala at Village Kair in AC-35.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All Kinds of soil.
2Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including letting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m - All kinds of soil - Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc, in layers not exceeding 20cm. in depth; consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m
4Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials - All kinds of soil
5Supplying an filling in plinth with Jamuna sand under floors including watering, ramming, consolidating and dressing complete
6roviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level - 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
7Providing and laying cement concrete in retaining walls, return walls, walls (any thickness including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
8Centering and shuttering including strutting, propping etc. and removal of form for:(8.1)- Foundations, footings, bases of columns etc. for mass concrete.
9Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
10Suspended floors, roofs, landing, balconies and access platform.
11Lintels, beams, plinth beams, girders, brussumers and cantilevers.
12Columns, pillars, pier, abutments, posts and struts.
13Centering and shuttering including strutting, propping etc. and removal of form for all heights Small linteis not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
14Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars.
15Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard settingof concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete - Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement - All works upto plinth level - Concrete of M25 grade with minimum cement content of 330 kg /cum
16Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard settingof concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete - Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement - All works above plinth level upto floor V level - Concrete of M25 grade with minimum cement content of 330 kg /cum
17Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand).
18Masonry work with C&D recycled cement concrete brick of size 230mm x110mm x75mm of grade M-10 in super structure above plinth level upto Level II with cement motar 1:6( 1 cement : 6 coarse sand).
19Granite (polished and machine cut) of thickness 18 mm for skirting, riser of steps etc.laid on 12 mm (average) thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the granite shade, including rubbing and polishing complete.
20Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all level - Granite stone slab of all colour and texture except black, Cherry/Ruby red - Area of slab over 0.50 sqm.
21Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
22Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete - 8 mm thick - Granite of any colour and shade
23Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
24Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete - 100x75x4 mm
25Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200 x 10 mm
26Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 x 10 mm
27Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm.
28Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper.
29Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp of internal dia. 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheetwith its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia. round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia. M.S. bar bent to shape as per standard drawing.
30Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
31Extra for pre finished nosing to treads of steps of marble stone.
32Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
33Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge- Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red
34Providing gola 75 x 75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with neat cement mortar 1:3 (1 cement : 3 fine sand) as per standard design: In 75 x 75 deep chase.
35Making khurras 45 X 45 cm with average minimum thickness of 5 cm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m X 1m X 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
36Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes, 110 mm diameter.
37Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised- Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion Bend 87.5 degrees, 110 mm bend.
38Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised- Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion Shoe (plain), 110 mm Shoe.
39Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length including cutting brickwork and fixing In cement mortar 1:4 (1 cement : 4 coarse sand) and making good the walls etc. complete, 110 mm.
40Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
4112 mm cement plaster of mix: 1:4 (1cement: 4 fine sand).
426 mm cement plaster of mix: 1:3 (1 cement : 3 fine sand).
43Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
44Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour - New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
45Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
46Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
47Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.
48Supply of earth at site including excavation, royalty, loading, unloading and banking the same in layers not exceeding 20 cm in depth, breaking clods and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions including carriage of earth by mechanical transport lead upto 10.00 km and lift upto 1.50m. All kinds of soil.
49Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : - For fixed portion - Powder coated aluminium (minimum thickness of powder coating 50 micron)
50Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : - For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for seperately). - Powder coated aluminium (minimum thickness of powder coating 50 micron)
51Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
52Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) - With float glass panes of 5 mm thickness (weight not less that 12.50 kg/sqm.)
53Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge - Powder coated minimum thickness 50 micron aluminium tubular handle bar
54Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
55Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete - Powder coated minimum thickness 50 micron aluminium
56Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admxed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over the R.C.C. slab including adjoining walls upto 300 mm height including cleanng the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bas 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cementslurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compoundconforming to IS:2645 and approved by Engineer-in-charge including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cemen slurry and making pattern of 300 x 300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of 2 weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer-in-charge: With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
57Constructing brick masonary manhole in cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floting coat of neat cement complete as per standard design: Inside size 90 x 80 cm and 45 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
58Providing, laying and jointing UPVC pipe in trenches including testing of joints etc. complete 160 mm diameter.
59Supplying & placing in position of SFRC precast reinforced cement concrete bench (Hand Rest Bench), each bench consists of two nos. L- Shape base support in cement colour (thickness – 80-mm. Back height 890 mm . Front height – 450 mm. and Base width 690 mm). and 1 no., reinforced cement plank in red co lour of size 1500 mm x 400mm x 50 mm and 1 no. of rein forced concrete plank in red co lour of size 1500mm x 425 mm x 50mm with overall dimensions : Seating length of the Bench – 1500 mm, seating height of the Bench - 450mm, Total height of the bench – 890 mm manufactured by using M-30 grade of concrete using vibro compaction process, reinforced suitably to promote long use and to prevent damaged during handing, transportation and erection. All parts are to be jointed together with galvanized nuts and bolts of suitable size and all bolts are to be sealed after assembly. The bench top and back planks are to be treated with special anti- corrosive water proof coating as to make surfaces glossy and water proof.
60Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround PVC pipes including bed concrete as per standard design: 150 mm diameter PVC pipe.
61Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group C.
62Wiring for light / power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
63Wiring for light / power plug with 4 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 2 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
64Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.(59.1)- 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (LIGHT CIRCUITS)
652 X 6 sq. mm + 1 X 6 sq. mm earth wire (AC CIRCUITS)
664 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire (LIGHT CIRCUITS)
674 X 6 sq. mm + 2 X 6 sq. mm earth wire (AC CIRCUITS & DB SUBMAINS)
684 X 10 sq. mm + 2 X 6 sq. mm earth wire (DB SUBMAIN FOR HALL)
69Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
70Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
71Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 6/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
72Installation, Testing and Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
73Installation, testing and commissioning of pre-wired, fluorescent fitting / CFL fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
74Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
75Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 4 way (4 + 12), Double door
76Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (OUTGOING MCB'S FOR DB'S).
77Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
78Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
79Supplying and fixing of suitable size GI box with modular plate and cover in front on surface / recess including providing & fixing 25 A modular socket outlet and 25 A modular motor starter including connections, painting etc. as required. (FOR AC SOCKETS).
80Supplying of 15 W surface mounted LED round low depth powder coated luminaire with drop down PC diffuser to deliver low glare illumination complete with LED lamp, connections etc. as required.
81Supplying of 36 W surface mounted LED light luminaire of size 600mm x 600mm complete with all accessories in the existing points including connection etc. as required.
82Supplying of 10 W LED bulk head luminaire with all accessories in the existing points including connection etc. as required.
83Supplying of 1200 mm sweep Power Saver A.C. electric Ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 Volts, 50 Hz, single phase, A.C. supply etc. as reqd.
84Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required - Triple pole and neutral - 63 A (INCOMER MCB'S FOR DB'S). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56629540
AUTHORITY Government Departments
TENDER VALUE 1.32 Crore
LAST DATE 29-07-2026
Authority
Authority Name Irrigation And Flood Control Department
Work Description Tender for Delhi Village Development Works In Nct Of Delhi.Sub Work :- Improvement, Repair And Construction Of Hall In Existing Vyayamshala At Village Kair In Ac-35.
Basic Detail
Tender No EE/CD-XIII/Acs./2026-27/NIT No. 31
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 23 Jul 2026
Submission Date 29 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 1.32 Crore
Tender Fee Ref. Documents
EMD 2.64 Lakhs
Exemption Not Available
Document List
9cf409ea-a7d3-42d4-b66a-f3f6f4ed7e01.html
BOQ_393577.xls
NIT31.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

9cf409ea-a7d3-42d4-b66a-f3f6f4ed7e01.html

xls

BOQ_393577.xls

pdf

NIT31.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender