Housing Urban and Rular Development Government Departments Closing in 1 days TDR #56628142

Tender For Restoration/Renovation Of Directorate Of Fisheries Office Complex/Fish Farm Nowabad Jammu (Damaged Due To Flash Floods)

Issued by Government Departments · Jammu, Jammu and Kashmir
Tender Value
29.13 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
1 days left
EMD
58260
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Restoration/Renovation Of Directorate Of Fisheries Office Complex/Fish Farm Nowabad Jammu (Damaged Due To Flash Floods)

BOQ

Name of Work:- Restoration/Renovation of Directorate of Fisheries office complex/fish farm Nowabad Jammu (Damaged due to flash floods)
Sl. No. Item Description
1Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
2Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below
3Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm
4Dismantling of flushing cistern of all types(C.I/PVC/Vitreous china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 meters lead
5Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand)
6Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
7Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with.1:5:10 (1 cement : 5coarse sand : 10 graded stone aggregate 40 mm nominal size)
812mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand)
915mm Cement plaster on the rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 fine sand)
10Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fitting complete 40 mm dia
11Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
12Providing and fixing 15 mm nominal bore tap . Long nose as per requirement by client dept.
13Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore
14Providing and fixing in position complete PVC floor trap of supreme / Prince make
15Providing and fixing in position complete stainless steel trap grating (jali)
16Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm
17Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter
18Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two Coats
19Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
20Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (600x600mm) Antiskid
21Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
22Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns)
23For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns)
24Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer- in-charge. (Cost of aluminum snap beading shall be paid in basic item.) With ACP sheet
25Providing and fixing glazing in aluminum door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not lessthan 10.00 kg / sqm)
26Providing and Fixing 0.50 wire gauge panelling fixed in aluminum doors windows shutters and partition frames
27Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(250x16mm)
28Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
29(200x10mm)
30(150x10mm)
31Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete
32125mm
33100 mm
34Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
35125x75x4 mm
36100x75x4 mm
37Providing and fixing counter top wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. counter top wasbasin as per design and make approved by engineer incharge with single 15 mm PTMT pillar cock swan type.
38Providing and fixing single body white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid (Kervoit & Jaguar) as per Engineer-in-charge.
39Providing and fixing health faucet/hand jet with flexible tube upto 1 metre long to European type W.C. of quality and make as approved by Engineer- in-charge.
40Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape Rectangular shape 1500x450 mm
41Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
42Providing and fixing 110 mm dia waste water / sewerage pipe of 4 kg pressure per sqcm of supreme / prince make
43Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm)
44Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work
45Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms
46Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms
47Labour to be engaged for removing vegitation & abonded material , for the cutting tress with the use of chemical , disposed off & cleaning of the site after compleation
48Earthwork in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5mtr in width) and for shafts, wells, cesspits and the like not exceeding 10sqm on plan, depth upto 1.5mtr including disposal of excavated earth upto 1 meter from cutting edge disposal earth is to be leveled and neatly dresses 1 meter lead.(All kinds of soils)
49Providing and laying in position cement concrete on 1:3:6 grade (1 cement: 3 coarse sand: 6 graded aggregates 20mm nominal size) excluding the cost of centering and shuttering all works upto plinth level (crushed) excluding all leads and carriages complete.
50Centering and shuttering including strutting, propping etc. and removal of form for.
51Foundations, footings, bases of columns etc
52Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board610x510mm bowl depth 200mm
53Disposal of mulba outside municipal limits
54Providing and fixing in position PVC wall panelling as per design/ colour/ make and pattern approved by the engineer incharge including cost of all the materials required for the same and labour including loading unloading and carriages and disposal of unwanted malba and rubbish all complete job.(Heavy duty). colour shade & material as per directions of intending department
55Providing and fixing PVC louvers/UV marble sheet in walls incl. all fittings and fixtures complete
56Providing and fixing of acrylic inaugration plate with necessary stainless steel distance holders and screws and plugs mentioning with painted letters the name of work all necessary details all complete job of minimum size 0.70 x 0.45 all complete job.
57Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machinewith strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge.
58Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishingand making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slabwith suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.).
59Providing/Fixing Stainless steel Balusters 4\\" Dia
60Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. Welded
61Providing and fixing UV stabilized fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts and nuts 8mm dia. G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-violet stabilizer in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS: 10192 and IS: 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.1 2mm thick corrugated (2.5\\" or 4.2\\" or 6\\") or step-down (2\\" or 3\\" or 6\\") as specified.
62Providing consultancy services for interior designing and layout for sitting/ office chambers as per requirements by the intending department and as per direction of Engineer-in Charge
63Carriage of materials (10km lead)
64Aggregate Above 40mm
65Aggregate Below 40mm
66Bricks 10 km lead
67Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
68Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Existing)
69Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
70Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
712 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
722 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
734 X 4 sq. mm + 2 X4 sq. mm earth wire
744 X 6 sq. mm + 2 X 6 sq. mm earth wire
754 x 10 sq. mm + 2 x 6 sq. mm earth wire
76Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.1 x 1.5 sq. mm
77Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
78Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
795/6 A switch
803 pin 5/6 A socket outlet
8115/16 A switch
826 pin 15/16 A socket outlet
83Bell push
84Ding Dong Bell
85Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
86Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
87Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\"curve including connections, painting etc. as required.
88Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
891 or 2 Module
903 Module
914 Module
926 Module
938 Module
9412 Module
95Supplying and fixing following size/ modules, GI box in recess etc as required.
961 or 2 Module (75mm X 75mm)
973 Module (100mm X 75mm)
984 Module (125mm X 75mm)
996 Module (200mm X 75mm)
1008 Module (125mm X 125mm)
10112 Module (200mm X 150mm)
102Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.
1034 way (Double door) (SPN type)
104Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.
1058 way (4+24), (Double door) (TPN type)
106Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.
107Single pole 6/10/16/32 Amp
108Single pole and neutral 32 Amp
109Single pole and neutral 40 Amp
110Single pole and neutral 63 Amp
111Triple pole and neutral 40 Amp
112Triple pole and neutral 63 Amp
113Supplying, Installation, Testing & Commissioning of 18 WATT LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver &electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained tilllife ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (StandardDeviation Colour Matching) <3, Maximum power consumption should not more than the specifiedrating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ NameEngraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Wattoutput . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junctiontemperature shall not rise above 90°C) Powder coated die cast /Extruded aluminiumBody including trim
114Supplying, Installation, Testing & Commissioning of 18- 22 Watt LED surface mounted Batten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
115Supplying, Installation, Testing & Commissioning of 36 watt Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained tilllife ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(StandardDeviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
116Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
117Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
118Ceiling fan 1200 mm sweep alongwith rod upto 1'-6\\" long (3 Star)
119Exhaust fan 300 mm size (Metalic)
120400 mm wall fan
121Supplying, installation, Testing & Commissioning of 150 watt Street light LED fixture powder coatedpressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,n Driver efficiency >85%,THD < 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the roadand the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electricalcircuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life endsas per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard completein all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C).
122Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
123Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
124Providing and fixing 4.00 mm dia copper wire on surface or inrecess for loop earthing as required.
125Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 Nos. long tubular batteries 150 AH and trolly of suitable size.
126Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)
127125 Amp, 36 KA, FP MCCB ICU = 100% ICS
128Repair of Panel (Complete)
129Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)
130150 sq. mm 3.5 core
131Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge. Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord
1321 Mtr
133Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.
134Supply Installation Testing and Commissioning of 6U Front Glass Door Single Section Wall Mount Cabinet Loaded with all Accessories like PDU , Cable Manager, Mounting Kit.Make- Duranet, Netrack, Dlink, APW, Rittal
135Supply, Installation, Testing and comissioning of 10 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 04 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link
136Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance withANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 Run of cable
137Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Cold type of minimum capacity following Specification as detailed below. 1. Should be of inverter type2. Cooling capacity (in Tr): 1.53. BEE Star rating: 34. Maximum local temperature: 52 C5. Rated cooling capacity (BTU/hr.): 19000 or above6. Condensing coil: 100% Copper with grooved copper tubes7. Electrical input, 220 V ± 30/50Hz/Single Phase8. Noise level (indoor unit): = close to 35 dB9. Compressor type: rotary or any other suitable technology10. Refrigerant type: R-3211. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent12. Compressor Warranty: 10 years13. PCB Warranty: 5 year14. Total System Warranty: 1 year15. Minimum noise level of the indoor unit should be around 28 dB (A) 16. Should have air filtering mechanism for removing dust17. Supplier has to include brochure of the quoted modelEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.
138Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Hot/ Cold (all weather) type of minimum capacity following Specification as detailed below. 1. Should be of inverter type2. Cooling capacity (in Tr): 1.53. BEE Star rating: 34. Maximum local temperature: 52 C5. Rated cooling capacity (BTU/hr.): 19000 or above6. Condensing coil: 100% Copper with grooved copper tubes7. Electrical input, 220 V ± 30/50Hz/Single Phase8. Noise level (indoor unit): = close to 35 dB9. Compressor type: rotary or any other suitable technology10. Refrigerant type: R-3211. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent 12. Compressor Warranty: 10 years13. PCB Warranty: 5 year14. Total System Warranty: 1 year15. Minimum noise level of the indoor unit should be around 28 dB (A)16. Should have air filtering mechanism for removing dust17 Supplier has to include brochure of the quoted modelEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.
139Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.
1404 KVA
141Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC
142Supplying & fixing of drain pipe for indoor unit 1\\"
143Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56628142
AUTHORITY Government Departments
TENDER VALUE 29.13 Lakhs
LAST DATE 29-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Restoration/Renovation Of Directorate Of Fisheries Office Complex/Fish Farm Nowabad Jammu (Damaged Due To Flash Floods)
Basic Detail
Tender No eNIT NO 46 of 2026-2027 Dated 23-07-2026
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 23 Jul 2026
Submission Date 29 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 29.13 Lakhs
Tender Fee 600
EMD 58260
Exemption Not Available
Document List
BOQ_1041072.xls
cf893490-ab26-4cca-9ce3-ad3a0f3bea37.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1041072.xls

html

cf893490-ab26-4cca-9ce3-ad3a0f3bea37.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender