Tender For Provision Of Drone Nursery And Provn Of Garbage Bins At Various Locations At Fazilka Mil Stn
Tender Value
14.57 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
3 days left
EMD
29200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Fazilka → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provision Of Drone Nursery And Provn Of Garbage Bins At Various Locations At Fazilka Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep for foundation etc and getting out in soft/loose soil. |
| 2 | M&L cement concrete 1:4:8 type D-2 using 40mm graded agg as in foundations filling and in mass concrete. all as specified. |
| 3 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified . |
| 4 | M&L Brickwork with Old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 5 | M-25 Design mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete (using 20 mm crushed stone graded aggregate) all as specified and shown on drg, including necessary form work, complete all as specified. |
| 6 | M-25 Design mix as in Columns, pillars, piers, posts and struts (using 20 mm crushed stone graded aggregate) all as specified and shown on drg, including necessary form work, complete all as specified. |
| 7 | M-25 Design mix as in Beams, cantilevers, bressummers, lintels over 1.5m span (using 20 mm crushed stone graded aggregate) all as specified and shown on drg.,including necessary form work, complete all as specified. |
| 8 | Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not proivded for, water troughs and the like including weathering, slightly rouinded for chamfered angles and throating, as directing |
| 9 | Form work to soffits of suspended slab such as roof slab, floor slabs landing and similar work; n.exc 200 mm thick |
| 10 | M-25 Design mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like using 20 mm graded aggregate |
| 11 | TMT Mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mmdia or securing with clips |
| 12 | Ditto but 6 mm to 8mm dia |
| 13 | Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 14 | M&L Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. |
| 15 | M&L Rendering 15mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified. |
| 16 | M&L Rendering 5mm thick on brick work or concrete surface in cement mortar 1:3 finished even and smooth without using extra cement all as specified. |
| 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft / loose soil. |
| 18 | Removing excavated material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point |
| 19 | M&L spreading leveling in layers n exc. 25cm thick and well ramming. |
| 20 | M&L 100mm thick cement concrete 1:3:6 type C-2 in sub base. |
| 21 | M&L broken brick Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 22 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 23 | M&L for treating the soil along with external perimeter of binding at the rate of 2.25 litres of emulsion per running metre complete all as specified. |
| 24 | M&L for pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete , of frame size 165 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified |
| 25 | M&L for providing cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified. |
| 26 | M&L for factory made, 2nd class hard wood rail and style 35 mm thick, plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered partical board with commercial veneering on both sides. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 27 | S&F Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted withcut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified. |
| 28 | M&L for preparation of wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified. |
| 29 | M&L for preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified. |
| 30 | M&L \\"Steel window factory made double shutter and tubular moulded frame of 16gauge suitable for double shutter as per drg (double for mosquito proof one glazed with glazing bars and one gauged without glazing bars) with side hung shutters including projecting type hinges non friction with 3mm thick 100mm long handle and two nos tower bolts 100mm long welded on 3.0mm thick MS plate to each window shutter and including hold fast and painting with one shop coat of zinc chrome primer.\\" complete all as specified. |
| 31 | Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 410-0 or Fe 310-0, all as specified . |
| 32 | S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia wire and average width of aperture 1.18mm mm and fixed with tinned tacks or galvanised wire staple complete all as specified . |
| 33 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified. |
| 34 | S&F 300 mm ordinary rat tail rod pattern spring incl roller and roller plate (Brass). |
| 35 | S&F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified. |
| 36 | S&F in repair only mild steel cold rolled butt hinges medium weight 100 mm long complete all as specified. |
| 37 | S&F in repair floor door stoper of Aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor overall length 150 mm inculuding valcanised rubber piece |
| 38 | S&F in repair Aluminium alloy, anodised, sliding door bolt 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 39 | S&F Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified . |
| 40 | S&F Aluminium handle, cast type, anodised 150 mm long complete all as specified. |
| 41 | M&L for 2nd class hard wood small fittings such as shaped door & window stops, cleat including all necessary labours, articles not exceeding 200 cubic centimeter each complete all as specified. |
| 42 | M&L for applying two coats of Oil emulsion distemper on walls including preparation of newly plastered surfaces with 3mm thick wall care putty complete all as specified. |
| 43 | M&L for applying three coats of white washing on ceiling including preparation of newly plastered surfaces complete all as specified. |
| 44 | M&L two coats of cement base paint and including preparation of surface new. |
| 45 | M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified. |
| 46 | M&L for 10mm thick rendering/screeding on fair faces of brick / concrete surfaces in cement mortar 1:4 and finished even and fair for receiving tiles complete all as specified. |
| 47 | M&L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 48 | M&L for providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified. |
| 49 | M&L Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:3 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. |
| 50 | Supply of waterproofing compound @ 2% of per kg cement used complete all as speccified.Make : Fosroc/Sika/Choksey/Chemsol/Bostik/STP |
| 51 | Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers for paino type fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 52 | All as per Item No.1 above here in before but for One three pins 5 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 53 | All as per Item No.1 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 54 | Description all as per item No.1 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. |
| 55 | Supply only modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 56 | Supply only modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 57 | Supply only modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 58 | Supply only modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 59 | M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete, |
| 60 | M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete, including provision of 1 x 10 sqmm nominal cross sectional area multistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 61 | S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCB incomer upto 125 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including MCCB 63 Amp and making good disturbed surfaces complete all as specified and directed. |
| 62 | Supply only MCCB 4 pole 100A , 415 V, 50Hz having breaking capacity 16 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engr.in.Charge. |
| 63 | S&F in concealed flush to wall factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ. |
| 64 | Supply and fixing amp rating 240V, 10KA 'C' curve SP 5 to 32 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 65 | S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 40 to 63 Amps all as specified and directed. |
| 66 | S& F plug and socket type DB (Functional unit)20 Amps capacity with provision of single pole 20 amps MCB,plug top and earth plug,grouted flush to walls complete all as specified. |
| 67 | Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 26W (± 10%), Temperature rise 40 degree maximum with remote, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified.Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 68 | Supply and fixing Air freshener fan PVC body, AC single Phase 230V, 50 Cycle per second, size 250mm sweep with blades and frame including making hole and self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. |
| 69 | S&F and testing of LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. |
| 70 | Supply and fixing complete set of 1x10 watt LED retrofit type bulkhead fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size light fitting any type complete all as specified and directed by Engineer-in-Charge. |
| 71 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 72 | M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm to 200mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor with min 80mm GI pipe complete all as specified and directed. |
| 73 | Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC/Steel tubular poles/stays and struts etc getting out including trimming sides and forming bottom surface all as specified and directed at site. |
| 74 | Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site |
| 75 | Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge. |
| 76 | Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, nominal outside diameter 77 mm minimum inside dia 63 mm conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable up to 25 sqmm 4 core complete all as directed. |
| 77 | Supply and fix light grade 50mm GI pipe fix complete to Wall , Poles etc with suitable clamp for protection of cable complete all as directed |
| 78 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core, laid underground including taking out stone patti/ interlocking tiles/ hard stone and re fixing the same properly same as existing surface, cable connection in panel/ VTPN DB etc with suitable size of alumimium lugs complete all as specified and as directed by Engineer-in-charge. |
| 79 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep for foundation etc and getting out in soft/loose soil. |
| 80 | M&L cement concrete 1:4:8 type D-2 using 40mm graded agg as in foundations filling and in mass concrete. all as specified. |
| 81 | M&L Brickwork with fly ash bricks (Old size), straight or curved on plan exc 6m mean radius, built in cement mortar 1.4. |
| 82 | Returning, filling in, including spreading, levelling ,watering and well ramming in layers not exc 25cm. |
| 83 | Removing excavated material to be a distance n exc. 50m and depositing where dlected at a level n exc. 1.5m above the starting point. |
| 84 | Rendering 15mm thick on external surfaces in cement mortar 1 :4 and finished even and smooth. |
| 85 | M&L 100 mm thick cement concrete type C-2 as in sub base. |
| 86 | M&L for 10 mm thick rendering/screeding on fair faces of brick / concrete surfaces in cement mortar 1:4 and finished even and fair for receiving tiles complete all as specified. |
| 87 | M&L two coats of cement base paint and including preparation of new surface . |
| 88 | M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement |
| 89 | M&L broken brick bat hardcore of gauge n.exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface. |
| 90 | PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in lintels upto 1.50m clear span, cills, coping, benching apex stone, bed plate, bed block including necessary from work. |
| 91 | S&F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. Fe 410-W (Gde- E-250) quality A |
| 92 | S&F Welded steel wire fabric supplied and fixed complete to wood or steel members n.exc 4.00 kg complete all as specified. |
| 93 | M&L for preparation of steel and iron new surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender