Power Boards / Undertakings / PSU Closing in 15 days TDR #56623949

Bids Are invited for Operation And Maintenance Of Electrical Systems/Electrical Installations - Complete System - Daily Routine Monitoring, Checking, Cleaning And Fault Attending Of All 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Emergency

Issued by Boards / Undertakings / PSU · Sonbhadra, Uttar Pradesh
Tender Value
59.83 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
15 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonbhadra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Operation And Maintenance Of Electrical Systems/Electrical Installations - Complete System - Daily Routine Monitoring, Checking, Cleaning And Fault Attending Of All 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Emergency Supply Restoration After Flashover Involving Busbar In 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Breakdown & Preventive Maintenance Of 6.6Kv Busbar System Including Earthing Transformers & Resistance Boxes In All The 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Breakdown & Preventive Maintenance Of 6.6Kv Vacuum & Sf6 Circuit Breakers In All 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Daily Routine Monitoring, Checking, Cleaning And Fault Attending Of All 0.4Kv Unit Switchgears Including Ussgs, Boiler Mccs, Misc. Mcc & Esp Switchgears. , Emergency Supply Restoration After Flashover Involving Busbar In All 0.4Kv Unit Switchgears Including Ussgs, Boiler Mccs, Misc. Mcc & Esp Switchgears. , Breakdown & Preventive Maintenance Of 0.4Kv Busbar System In All 0.4Kv Unit Switchgears , Breakdown, Preventive Maintenance & Servicing Of 0.4Kv Air Circuit Breakers In All 0.4Kv Unit Switchgears , Emergency Restoration Of 0.4Kv Acb/Dol/Sfu Modules/Panels After Flash Over/Breakdown In All 0.4Kv Unit Switchgears , Daily Routine Monitoring, Checking Cleaning And Fault Attending Of 0.4Kv Bop Switchgears Including Station Service S/Gs, Ash Handling S/Gs, Booster Mccs, Wtp And Cw Pump House Switchgears. , Emergency Supply Restoration After Flashover Involving Busbar In All 0.4Kv Bop Switchgears , Breakdown & Preventive Maintenance Of 0.4Kv Busbar System In All 0.4Kv Bop Switchgears , Breakdown, Preventive Maintenance & Servicing Of 0.4Kv Air Circuit Breakers In 0.4Kv Bop Switchgears , Emergency Restoration After Flashover/Breakdown In 0.4Kv Acb/Dol/Sfu/Aux. Control Module/Panel In 0.4Kv Bop Switchgears , Daily Routine Monitoring, Checking, Of Microcontrollers Bases Esp Controllers And Rapper Programmer With Assosiated Auxilaries And Ash Level Indicator (Electronic Unit), With Rf Sensing Probe, Of Esp Pass Of 5X200mw, Btps, Obra. , Breakdwon & Preventive Maintenanace Of Esp Control Cubicles , Breakdown & Preventive Mainatenence Of Auxiliary Control Panel And Rapper Programmer Unit. , Breakdown & Preventive Mainatenence Of Ash Level Indicators Probe And Ali Units , Preventive & Breakdown Maintenance Of Esp Hopper Heater, Support And Shaft Insulator Heater And Its Power Supply Modules. , Daily Routine Monitoring Of Esp Hvr Transformer And Associated System In 5X200mw, Btps, Obra. , Daily Routine Monitoring, Operation And Maintenance Of Rapping Motors (Emmitting & Collecting) And It Power Supply Modules. , Breakdown Maintenance, Overhauling And Testing Of Esp Transformers. , Preventive Maintenance Of Esp Hvr Transformer, Support Insulators, Isolator Insulators, Negative Bushing And Their Chambers. , Cleaning And Upkeeping Of Esp Top Floor At 35M. (1Job = Monthy Cleaning Each Unit) , Shifting Of Repaired/Damaged/New Esp Hvr Transformer Form Storage Place In Plant To Esp Ground Floor And Vice-Versa. , Lifting Up /Down Of Repaired/Damaged/New Esp Hvr Transformer Form Esp Ground Floor At 0M To Esp Top At 35M And Vice-Versa. , Dismantling/Commissioning Repaired/Damaged/New Esp Hvr Transformer Along With Negative Link Rod, Bushing Etc And Other Associated Works. , Shifting Of Centrifuging Machine From Site Of Storage To Work Site/Esp Top At 35M And Vice-Versa

BOQ

Sl. No. Item TitleItem Description
1Daily routine monitoring, checking, cleaning and fault attending of all 6.6KV Unit & BOP Switchgears of 5x200MW, BTPS, Obra.Daily routine monitoring, checking, cleaning and fault attending of all 6.6KV Unit & BOP Switchgears of 5x200MW, BTPS, Obra.
2Emergency supply restoration after flashover involving Busbar in 6.6KV Unit & BOP Switchgears of 5x200MW, BTPS, Obra.Emergency supply restoration after flashover involving Busbar in 6.6KV Unit & BOP Switchgears of 5x200MW, BTPS, Obra.
3Breakdown & preventive maintenance of 6.6KV Busbar System including Earthing Transformers & Resistance Boxes in all the 6.6KV Unit & BOP Switchgears of 5x200MW, BTPS, Obra.Breakdown & preventive maintenance of 6.6KV Busbar System including Earthing Transformers & Resistance Boxes in all the 6.6KV Unit & BOP Switchgears of 5x200MW, BTPS, Obra.
4Breakdown & preventive maintenance of 6.6KV Vacuum & SF6 Circuit Breakers in all 6.6KV Unit & BOP Switchgears of 5x200MW, BTPS, Obra.Breakdown & preventive maintenance of 6.6KV Vacuum & SF6 Circuit Breakers in all 6.6KV Unit & BOP Switchgears of 5x200MW, BTPS, Obra.
5Daily routine monitoring, checking, cleaning and fault attending of all 0.4KV Unit Switchgears including USSGs, Boiler MCCs, Misc. MCC & ESP Switchgears.Daily routine monitoring, checking, cleaning and fault attending of all 0.4KV Unit Switchgears including USSGs, Boiler MCCs, Misc. MCC & ESP Switchgears.
6Emergency supply restoration after flashover involving Busbar in all 0.4KV Unit Switchgears including USSGs, Boiler MCCs, Misc. MCC & ESP Switchgears.Emergency supply restoration after flashover involving Busbar in all 0.4KV Unit Switchgears including USSGs, Boiler MCCs, Misc. MCC & ESP Switchgears.
7Breakdown & preventive maintenance of 0.4KV Busbar System in all 0.4KV Unit SwitchgearsBreakdown & preventive maintenance of 0.4KV Busbar System in all 0.4KV Unit Switchgears
8Breakdown, preventive maintenance & servicing of 0.4KV Air Circuit Breakers in all 0.4KV Unit SwitchgearsBreakdown, preventive maintenance & servicing of 0.4KV Air Circuit Breakers in all 0.4KV Unit Switchgears
9Emergency restoration of 0.4KV ACB/DOL/SFU modules/panels after flash over/breakdown in all 0.4KV Unit SwitchgearsEmergency restoration of 0.4KV ACB/DOL/SFU modules/panels after flash over/breakdown in all 0.4KV Unit Switchgears
10Daily Routine monitoring, Checking Cleaning and Fault Attending of 0.4KV BOP Switchgears including Station Service S/Gs, Ash Handling S/Gs, Booster MCCs, WTP and CW Pump House switchgears.Daily Routine monitoring, Checking Cleaning and Fault Attending of 0.4KV BOP Switchgears including Station Service S/Gs, Ash Handling S/Gs, Booster MCCs, WTP and CW Pump House switchgears.
11Emergency supply restoration after flashover involving Busbar in all 0.4KV BOP SwitchgearsEmergency supply restoration after flashover involving Busbar in all 0.4KV BOP Switchgears
12Breakdown & preventive maintenance of 0.4KV Busbar System in all 0.4KV BOP SwitchgearsBreakdown & preventive maintenance of 0.4KV Busbar System in all 0.4KV BOP Switchgears
13Breakdown, preventive maintenance & servicing of 0.4KV Air Circuit Breakers in 0.4KV BOP SwitchgearsBreakdown, preventive maintenance & servicing of 0.4KV Air Circuit Breakers in 0.4KV BOP Switchgears
14Emergency restoration after flashover/breakdown in 0.4KV ACB/DOL/SFU/Aux. Control module/panel in 0.4KV BOP SwitchgearsEmergency restoration after flashover/breakdown in 0.4KV ACB/DOL/SFU/Aux. Control module/panel in 0.4KV BOP Switchgears
15Daily routine monitoring, checking, of microcontrollers bases ESP controllers and rapper programmer with assosiated auxilaries and ash level indicator (electronic unit), with RF sensing probe, of ESP Pass of 5x200MW, BTPS, Obra.Daily routine monitoring, checking, of microcontrollers bases ESP controllers and rapper programmer with assosiated auxilaries and ash level indicator (electronic unit), with RF sensing probe, of ESP Pass of 5x200MW, BTPS, Obra.
16Breakdwon & preventive maintenanace of ESP Control CubiclesBreakdwon & preventive maintenanace of ESP Control Cubicles
17Breakdown & preventive mainatenence of auxiliary control panel and rapper programmer Unit.Breakdown & preventive mainatenence of auxiliary control panel and rapper programmer Unit.
18Breakdown & preventive mainatenence of Ash Level Indicators probe and ALI UnitsBreakdown & preventive mainatenence of Ash Level Indicators probe and ALI Units
19Preventive & breakdown maintenance of ESP hopper heater, support and shaft insulator heater and its power supply modules.Preventive & breakdown maintenance of ESP hopper heater, support and shaft insulator heater and its power supply modules.
20Daily routine monitoring of ESP HVR transformer and associated system in 5x200MW, BTPS, Obra.Daily routine monitoring of ESP HVR transformer and associated system in 5x200MW, BTPS, Obra.
21Daily routine monitoring, operation and maintenance of rapping motors (emmitting & collecting) and it power supply modules.Daily routine monitoring, operation and maintenance of rapping motors (emmitting & collecting) and it power supply modules.
22Breakdown maintenance, overhauling and testing of ESP transformers.Breakdown maintenance, overhauling and testing of ESP transformers.
23Preventive maintenance of ESP HVR transformer, support insulators, isolator insulators, negative bushing and their chambers.Preventive maintenance of ESP HVR transformer, support insulators, isolator insulators, negative bushing and their chambers.
24Cleaning and upkeeping of ESP top floor at 35m. (1Job = monthy cleaning each Unit)Cleaning and upkeeping of ESP top floor at 35m. (1Job = monthy cleaning each Unit)
25Shifting of repaired/damaged/new ESP HVR transformer form storage place in plant to ESP ground floor and vice-versa.Shifting of repaired/damaged/new ESP HVR transformer form storage place in plant to ESP ground floor and vice-versa.
26Lifting up /down of repaired/damaged/new ESP HVR transformer form ESP ground floor at 0m to ESP top at 35m and vice-versa.Lifting up /down of repaired/damaged/new ESP HVR transformer form ESP ground floor at 0m to ESP top at 35m and vice-versa.
27Dismantling/commissioning repaired/damaged/new ESP HVR transformer along with negative link rod, bushing etc and other associated works.Dismantling/commissioning repaired/damaged/new ESP HVR transformer along with negative link rod, bushing etc and other associated works.
28Shifting of centrifuging machine from site of storage to work site/ESP top at 35m and vice-versaShifting of centrifuging machine from site of storage to work site/ESP top at 35m and vice-versa

AI Tender Summary

OUR REF NO 56623949
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 59.83 Lakhs
LAST DATE 14-08-2026
Authority
Authority Name Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited
Work Description Bids Are invited for Operation And Maintenance Of Electrical Systems/Electrical Installations - Complete System - Daily Routine Monitoring, Checking, Cleaning And Fault Attending Of All 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Emergency Supply Restoration After Flashover Involving Busbar In 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Breakdown & Preventive Maintenance Of 6.6Kv Busbar System Including Earthing Transformers & Resistance Boxes In All The 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Breakdown & Preventive Maintenance Of 6.6Kv Vacuum & Sf6 Circuit Breakers In All 6.6Kv Unit & Bop Switchgears Of 5X200mw, Btps, Obra. , Daily Routine Monitoring, Checking, Cleaning And Fault Attending Of All 0.4Kv Unit Switchgears Including Ussgs, Boiler Mccs, Misc. Mcc & Esp Switchgears. , Emergency Supply Restoration After Flashover Involving Busbar In All 0.4Kv Unit Switchgears Including Ussgs, Boiler Mccs, Misc. Mcc & Esp Switchgears. , Breakdown & Preventive Maintenance Of 0.4Kv Busbar System In All 0.4Kv Unit Switchgears , Breakdown, Preventive Maintenance & Servicing Of 0.4Kv Air Circuit Breakers In All 0.4Kv Unit Switchgears , Emergency Restoration Of 0.4Kv Acb/Dol/Sfu Modules/Panels After Flash Over/Breakdown In All 0.4Kv Unit Switchgears , Daily Routine Monitoring, Checking Cleaning And Fault Attending Of 0.4Kv Bop Switchgears Including Station Service S/Gs, Ash Handling S/Gs, Booster Mccs, Wtp And Cw Pump House Switchgears. , Emergency Supply Restoration After Flashover Involving Busbar In All 0.4Kv Bop Switchgears , Breakdown & Preventive Maintenance Of 0.4Kv Busbar System In All 0.4Kv Bop Switchgears , Breakdown, Preventive Maintenance & Servicing Of 0.4Kv Air Circuit Breakers In 0.4Kv Bop Switchgears , Emergency Restoration After Flashover/Breakdown In 0.4Kv Acb/Dol/Sfu/Aux. Control Module/Panel In 0.4Kv Bop Switchgears , Daily Routine Monitoring, Checking, Of Microcontrollers Bases Esp Controllers And Rapper Programmer With Assosiated Auxilaries And Ash Level Indicator (Electronic Unit), With Rf Sensing Probe, Of Esp Pass Of 5X200mw, Btps, Obra. , Breakdwon & Preventive Maintenanace Of Esp Control Cubicles , Breakdown & Preventive Mainatenence Of Auxiliary Control Panel And Rapper Programmer Unit. , Breakdown & Preventive Mainatenence Of Ash Level Indicators Probe And Ali Units , Preventive & Breakdown Maintenance Of Esp Hopper Heater, Support And Shaft Insulator Heater And Its Power Supply Modules. , Daily Routine Monitoring Of Esp Hvr Transformer And Associated System In 5X200mw, Btps, Obra. , Daily Routine Monitoring, Operation And Maintenance Of Rapping Motors (Emmitting & Collecting) And It Power Supply Modules. , Breakdown Maintenance, Overhauling And Testing Of Esp Transformers. , Preventive Maintenance Of Esp Hvr Transformer, Support Insulators, Isolator Insulators, Negative Bushing And Their Chambers. , Cleaning And Upkeeping Of Esp Top Floor At 35M. (1Job = Monthy Cleaning Each Unit) , Shifting Of Repaired/Damaged/New Esp Hvr Transformer Form Storage Place In Plant To Esp Ground Floor And Vice-Versa. , Lifting Up /Down Of Repaired/Damaged/New Esp Hvr Transformer Form Esp Ground Floor At 0M To Esp Top At 35M And Vice-Versa. , Dismantling/Commissioning Repaired/Damaged/New Esp Hvr Transformer Along With Negative Link Rod, Bushing Etc And Other Associated Works. , Shifting Of Centrifuging Machine From Site Of Storage To Work Site/Esp Top At 35M And Vice-Versa
Basic Detail
Tender No GEM/2026/B/7817162
Bidding Type Tender
Location
City Sonbhadra
State Uttar Pradesh
Key Dates
Publish Date 23 Jul 2026
Submission Date 14 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 59.83 Lakhs
Tender Fee Ref. Documents
EMD 1 Lakhs
Exemption Not Available
Document List
31d8cd26-74b8-4882-812c-5e7f6cbad261.pdf
1784639694.pdf
1784639717.pdf
1784639733.pdf
1784639750.pdf
1784639762.pdf
1784808643.xlsx
TSDGeM_c177869f-7a89-4a56-95c81784640996739_ee_emd1_btps_obra.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

31d8cd26-74b8-4882-812c-5e7f6cbad261.pdf

pdf

1784639694.pdf

pdf

1784639717.pdf

pdf

1784639733.pdf

pdf

1784639750.pdf

pdf

1784639762.pdf

xlsx

1784808643.xlsx

pdf

TSDGeM_c177869f-7a89-4a56-95c81784640996739_ee_emd1_btps_obra.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders