Tender For Special Repair To Building No P-87 Otm Accn And Bldg No 137 Alma (Toilet And Bathroom) At Krc Ranikhet Under Ge Ranikhet
Tender Value
36.56 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
17 days left
EMD
73200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Almora → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No P-87 Otm Accn And Bldg No 137 Alma (Toilet And Bathroom) At Krc Ranikhet Under Ge Ranikhet
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as directed. |
| 2 | M & L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes Complete all as specified and directed. |
| 3 | M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. |
| 4 | M&L 300x450x7mm thick glazed ceramic digital tiles coloured incl , design and pattern as approved fixed as in vertical surface etc, set and jointed in neat cement slurry and pointed with white cement with colour pigment to match incl rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and directed. |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 6 | M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement Complete all as specified and directed. |
| 7 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m Complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls by adding 17-19% of potable water by weight of material for thickness above 15mm it is recommended to be applied in multiple layers. ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the compressive strength @ 28 days 10-12 Mpa/Bulk density 1500-1600 Kg/m3. (Note : The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 Mtr ht all as specified and directed) |
| 9 | M/L for preparing newly plastered wall surfaces and applying two coat of distemper oil emulsion over 1mm thick wall care putty, complete all as specified . |
| 10 | M & L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90litre/10 sqmover new surfaces. |
| 11 | M&L Preparation of old plastered surfaces of walls incl washing rubbing down and stopping of distempered and painted and applying two coat of oil bound distemper on old decorated surfaces on walls incl filling of nail holes by cementious wall care putty all as specified and as directed. The contractor shall make necessary arrangement of scaffolding and ensure safety of Labours. |
| 12 | M&L for preparation of old plastered surfaces & applying a layer of Birla putty on wall surfaces including cornics etc for proper levelling of plaster and two coat of oil emulision distemper complete all as specified and directed. |
| 13 | M&L for preparation of Old plastred surfaces of wall and applying one coat of exterior emulsion anti-fungal weather proof paint on external wall incl filling of nail holes by cementious wall care putty all as specified.NOTE: The painting work to be executed by authorised applicator of the manufacturer.Make :-APEX ULTIMA OF Asian Paint or WEATHER COAT SMOOTH of Berger or Nerolac Excel Top guard of Nerolac.The contractor shall make necessary arrangement of scaffolding and ensure safety of Labours. |
| 14 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc |
| 15 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete al as specified |
| 16 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) but exc. 1.5 sqm n. exc.4sqm each & removing to or from store complete all as specified and directed. |
| 17 | M&L for Pressed steel frames 125X60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,supplied and fixed complete all as specified and directed. |
| 18 | S&F 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed |
| 19 | S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., rs, edges of framing plain, chamfered complete all as specified and directed. |
| 20 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frames, glazed with putty or fixed with beads including punching or drilling out old glazing pins/spring clips and providing and fixing new ones all as specified |
| 21 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in each pane complete all as specified and directed. |
| 22 | S&F in repairs of galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 23 | S & F 125 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed |
| 24 | S & F butt hinges, medium weight, Miled steel and fixed, size of hinges 100mm complete all as specified and directed. |
| 25 | S & F 150 mm long Extruded brass handles,fabricated type polished complete all as specified and directed. |
| 26 | Supply and fix 300 mm long ABrass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed. |
| 27 | M & L for Old painted surface to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coats of synthetic enamel including preparation of surfaces complete all as specified and directed. |
| 28 | Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 29 | Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 30 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 31 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store. |
| 32 | Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store. |
| 33 | S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 34 | S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 35 | S&F in repairs stop valves/angle valves, cast copper alloy, fency type chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe. |
| 36 | S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed.Make i ( Jaquar cat Part No:- COP -001BPM ii ( Marc cat Part No :- MFX- 2010 or Cera Equalant. |
| 37 | M&L for preparation of new steel surfaces over 10cm width & girth and applying tow coats ofsynthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 38 | M&L for preparation of new wooden surfaces over 10cm width & girth and applying tow coats ofsynthetic enamel paint over a coat of pink primer complete all as specified and directed |
| 39 | S&F brass chromium plated tubular towel rail, 20 mm dia, D; type, 60 cm long between flanges complete all as specified and directed.Make i ( Jaquar cat Part No:- ACN 11815 ii ( Marc or Cera Equalant. |
| 40 | S & F 20mm Dia Aluminium alloy anodised curtain rod decorative fency type with brackets complete all as specified. |
| 41 | S & F PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends |
| 42 | Dismantling water tanks of any description, capacity exceeding 500 litres but not exceeding1000 liters complete. |
| 43 | S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of Make - Prayag complete all as specified and directed. |
| 44 | S&F in repairs Gun-metal, globe or gate valves 15 mm, with iron wheel head, screwed both ends for iron pipe and fixed |
| 45 | S&F in repair for PVC (SWR) floor trap 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed |
| 46 | Dismantling timber scantlings 40 sq. cm unframed work and over in section, in any position |
| 47 | Dismantling boarding, any description, fixed in any position with nails |
| 48 | M & L for second class wrought hard-wood timber fixed in scantlings complete all as specified and directed |
| 49 | M & L for 25mm thick second class hardwood, width n exc.20cm complete all as specified and directed |
| 50 | M & L for Plywood 12 mm thick, grade BWP, type BB fixed with screws to timber frame work complete all as specified and directed |
| 51 | S&F in repairs parquet flooring 8.3 mm thick hard board plank both side laminated with decorative surface and approved by GE laid above the thermoplastic sheet complete all as spd |
| 52 | Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete. |
| 53 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 54 | S & F for Aluminium anodised snap grid frame work for false ceiling comprising of following section for making partitions of 605 X 605 mm size fixed to walls with rawl plugs and screws and hang to roof with s 6 mm dia. G.I. (upto1200mm length) adjusting levelfixed to roof slabs by means ofceilling cleats made out of G.I.flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified. size of main tee shall be :-(i)36.5mmx25mmx1.4mm thick, Weighing 0.24Kg/Rm(ii)Cross Tee 23.5mmx36.4mmx1.4mm thick Weighing 0.191 Kg/Rm and (iii)Wall angle 40mmx25mmx2mm thick. Weighing 0.36 Kg/Rm |
| 55 | S & F 4 mm thick non asbestos fiber disigner ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 600 X 600 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed |
| 56 | Supply and fixing in repair wash hand basin vitreous China table top type any size including cutting hole and pinning in ends of brackets or erecting stand with fixing 32mm dia waste coupling brass chromium plated suitable for wash basin and PVC waste pipe all as spd and directed . |
| 57 | Dismantaling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 58 | S&F Pre-painted galvaLume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed. |
| 59 | S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall ,valle gutters, drip, fixed self tapping screws complete all as specified and directed. |
| 60 | Taking down chowkat or frames with shutter (without taking off shutters from the frame) not exc 1.5 sqm |
| 61 | Dismantling water tanks 500 ltrs capacity complete all as specified and directed. |
| 62 | S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of complete all as specified and directed. |
| 63 | M & L for roof surface must be pressure-washed with water with, is to be used to and/ or remove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution. 2 tiles joint repair all visible and joint more than 0.50mm and not giving hollow sound, on the tiles roof or at the junctions of flat roof & vertical parapet wall, pipe joints, should be cut and widen v shape with mechanical cutter in the size (6mm W x 6mm D) and fill with Dr. Fixit PMM methodology.Glass fiber apply Dr Fixit URP or Primeseal A on the well prepared groove, allow to cure tack free. Followed by filling all the joints covering the entire area uniformly with suitable chemical. Allow chemical to cure a minimum 24 hours. Apply minimum 50mm-100mm width 45 GMS glass Fibre mesh/ non-woven geo testile fleece with the coat of Dr Fixit Roofseal classic along the length of crack when the 1st coat is still in wet condition. Apply the second coat with an interval if 4-6 hours. Waterproofing: Apply a coat of Dr Fixit Roofseal classic (diluted with water in the ratio 2:1) as Self Priming 14.0-18.0 Sq. mt/litre.Allow coating to dry for 3-4 hours. Applt two coats of Dr Fixit Roofseal classic/litre/coat, without, the rate of application being the same for both the coats. This would ensure correct consumption of material that will deliver a total of DFT of microns. Allow the system to air cure for 5 days minimum. Check to see no void surface is left untreated/uncoated. The material having following technical specification as per ASTM D 6083 M- type II, Attains a Tensile strength of 2.5 N/mm2 confirming to ASTM D 2370: Elongation at break > 300% confirming ASTM D 2370, Adhesion to Concrete 2.0N/mm2 Confirming ASTM D 4541 and crack bridging ability up to 2mm, air cure the coating for 7 days before water pound test for 48 Hrs. The system comes with 7 year waterproofing warranty from service provider. For vertical surface : Apply 2 coat of Dr Fixit Roofseal classic with forced coverage of /litre/coat. Entire terrace should be coated with roofseal classic alongwith parapet walls needs to be enveloped with roofseal classic/Raincoat system. The total 3 coats treatment inclu taking down/dismantling of old tarfelt/old unserviceable roof treatment from RCC roof by scrapping, broomig and washing with water etc and including 10mm thick rendering in CM 1:3 mixing with water proofing compund, Make : Dr Fixit or equivalent (Note : The treatment should be carried out through authorised applicator only) |
| 64 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick wall built in CM (1:6) complete al as specified |
| 65 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 66 | S & F MS framed work such as grills, gratings, etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 190-0 or Fe-165-0. |
| 67 | M&L rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 as in ceiling incl finished even and smooth (without using extra cement). |
| 68 | M&L colour non skid ceramic tiles 7 to 8 mm thick ( square/ rectangular) area of each tiles exc. 0.11 sqm but n.exc. 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement with colour pigment incl 15mm thick screed bed in CM 1:6 complete all as spd |
| 69 | S&F 100mm long aluminium anodized handles of extruded section |
| 70 | S&F 300mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy |
| 71 | S& F in repair vitreous China squatting pan, ‘Orissa’pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including P or S trap complete all as specified |
| 72 | S&F in repairs 10 ltr capacity PVC Low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 600mm long etc complete. |
| 73 | S & F in repairs Vitreous China urinal half stall white (minimum), with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistren with brackets brackets flush pipe, grating and union for discharge pipe in repairs complete all as specified and as directed. |
| 74 | Supply and fixing in repair 15mm dia long body bib tap fancy type chromium plsted with crutch or butter fly handle screwed down screwed for Iron pipe or brass ferrule and fixed. |
| 75 | Cutting chases, for water tubing or concealed , etc, and making good to facings where required and plastering in cement mortar (1:3) cutting not exceeding 10cm girth in brick walls complete all as specified and directed. |
| 76 | S&F in repair 5.8 mm thick beveled edges mirror of selected quality glass of modi guard, Atul, mounted on 6mm thick AC building board or commercial plywood including PVC frame |
| 77 | S&F in repairs aluminium anodised tubular towel rail, 20mm dia ‘D’ type, 60CM long between flanges. |
| 78 | Supply and fixing in repair 15mm dia 600mm long PVC connection with PTMT nut and washer complete |
| 79 | S&F in repairs CP Soap dish 150mm, fixed to wall with chromium plated brass screws complete all as specified |
| 80 | S & F 12mm thick tempered glass urinal partition with steel frame including all cuts & holes for fixing in size & design as approved by GE complete all as specified |
| 81 | S & F stainless towel ring complete all as specified & directed |
| 82 | S&F 20 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe of brass ferrule and fixed. |
| 83 | S & F in repair 20mm gun metal globe or gate valve wirh iron wheels head screwed both ends for iron pipe |
| 84 | S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints laid in trenches or floor complete. |
| 85 | S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete. |
| 86 | S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete. |
| 87 | S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints laid in trenches or floor etc complete. |
| 88 | M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete, fixed in repair. |
| 89 | S&F PVC (SWR) bends 110mm dia any radius |
| 90 | S&F PVC (SWR) bends 75 mm dia any radius |
| 91 | S&F PVC (SWR) junction single,(Single T) 110mm dia equal or unequal with access door |
| 92 | S&F PVC (SWR) junction single,(Single T) 75mm dia equal or unequal with access door |
| 93 | S&F PVC (SWR)vent cowl 110mm bore |
| 94 | M & L complete removal of existing treatment and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new or old surfaces of wall complete all as specified. |
| 95 | M & L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new or old surfaces of wall complete all as specified. |
| 96 | M & L for complete removal of existing treatment of wall and applying two coats of distemper oil bound over 1 mm thick of birla wall care putty including preparation of surfaces complete all as specified |
| 97 | M & L for preparing old surfaces of ceiling and applying two coats of white wash complete all as specified |
| 98 | M & L for preparing new plastered surfaces of ceiling and three coats of white wash complete all as specified |
| 99 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed. |
| 100 | Demolition and breaking up drain pipes 150 mm (salts glazed ware ,AC or Reinforced concrete) set in cement mortar all as specified |
| 101 | M & L 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed as specified complete all as specified and directed. |
| 102 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed. |
| 103 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed. |
| 104 | Removing Excavated soil exceeding 250 M but not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 105 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed |
| 106 | M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 107 | M&L for providing precast cement concrete 1:2:4 type B1 (20mm graded aggregate) as in cover slab for manholes complete all as sp[ecified and directed |
| 108 | M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 109 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 110 | M/LCement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in surface channels and drains complete. |
| 111 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.All as specified and directed. |
| 112 | Taking down old U/S cable and Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core. |
| 113 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of underground cable and getting out in any type of soil complete all as directed by the Engineer-in-Charge |
| 114 | Removal of surplus soil not exceeding 50 Mtr and depositing where directs at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 115 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified |
| 116 | M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the lengrth of brick complete all as specified . |
| 117 | M & L galvanised steel water tubing 'light grade' 40 mm bore with all fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed . |
| 118 | Taking down carefully Aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. |
| 119 | M & L point wiring for Modular fittings for one light point/ fan/ bell/ 5Amps socket out let (independent)point controlled by one, one way switch with 1.5 sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FR-LSH) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia )with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) incl one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed. (a) One light/One fan/one bell point controlled by one modular switch |
| 120 | One light point controlled by Two way modular switch. |
| 121 | One modular socket outlet 3 pin 6 amps controlled by one switch on same board. |
| 122 | One modular socket outlet 3 pin 6 amps controlled by one switch on independent board incl modular metal flush box for mounting modular fittings and covered with modular cover plate with frame and cup washers. |
| 123 | All as per item No 122 herein before but wiring with 2.5 sqmm copper wire (FRL-SH) PVC and 2.5 sqmm earth wire for modular socket outlet 5 pin 16 amps on independent board incl modular metal flush box for mounting modular fittings and covered with modular cover plate with frame and cup washers. |
| 124 | Supply and fix modular type switch single pole, one way 6 Amp complete all as specified and directed. |
| 125 | S&F modular switch, 2 way 6 Amp 1 module complete all as specified and directed. |
| 126 | Supply and fix socket out let multi 5 pin, 6 Amps, modular type complete all as specified and directed. |
| 127 | Supply and fix switch modular type single pole, one way 16 Amp complete all as specified and directed. |
| 128 | Supply and fix socket out let 2 in1,3 pin, 6 and 16 Amp, modular type complete all as specified and directed. |
| 129 | Supply and fix modular metal flush box of 3 module for mounting modular fittings complete all as specified and directed. |
| 130 | Supply and fix modular metal flush box of 4 module for mounting modular fittings complete all as specified and directed. |
| 131 | Supply and fix modular metal flush box of 1 module for mounting modular fittings complete all as specified and directed. |
| 132 | Supply and fix modular cover plate with frame and cup washers of size 3 module complete all as specified and directed. |
| 133 | Supply and fix modular cover plate with frame and cup washers of size 4 module complete all as specified and directed. |
| 134 | Supply and fix modular cover plate with frame and cup washers of size 1 module complete all as specified and directed. |
| 135 | S&F ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed. |
| 136 | S & F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. |
| 137 | S& F LED Bulb of 9 watt as specified .NOTE: The contractor must submit 5 years warranty for LED fittings |
| 138 | Supply and fix High quality LED T8 indoor batten tube light 20 Watt with aluminium extrusion in D shaped have large diameter for increased convection heat transfer incl one LED PC tube rod and driver, internaly pre wired of 1.5 sqmm twin twisted flexible cable all as specified & directed.NOTE: The contractor must submit 5 years warranty for LED fitiings. |
| 139 | Taking down unservicable MCB and S&F MCB SP, 240 volts,AC C curve, 10 KA 6 to 32 Amps . |
| 140 | Taking down unservicable MCB and S&F MCB SPN , 240 volts,AC B curve, 10 KA 40 Amps. |
| 141 | Taking down unservicable MCB and S&F MCB DP , 240 volts,AC C curve, 10 KA 40 Amps. |
| 142 | Taking down unserviceable MCB S & F MCB TPN , 415 volts, AC C curve, 10 KA 100 Amps. |
| 143 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. all as specified and directed .NOTE : The contractor must submit 5 years warranty for LED fittings |
| 144 | Taking down unservicable DB and S&F sheet metal enclusure for DBs(double door type) single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 145 | S&F sheet metal enclusure for DBs(double door type) Triple pole and neutral 4 way including blacking platge as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed . |
| 146 | S & F LED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser including LED light driver holder, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings. |
| 147 | Taking out old U/S Sub main wiring for replacement including S&F sub main wiring with two single core FRLSH PVC insulated and sheathed 1100 Volts grade, 6.0 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mm dia with all accessories and one continuous run of 6.0 Sqmm copper conductor PVC complete all as specified and directed (Note :- Two single core cables along with earth wire and conduit shall be measured as one unit length). |
| 148 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender