Tender For Various Civil Works At The Florence Nightangle Hostel, Bhu.- 1 Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar (15.7.4) 2 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood) Including Stacking Within 50 Metres Lead : Of Area 3 Sq. Metres And Below (15.13.1) 3 Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. Nominal Concrete 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) (15.2.1) 4 Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. Nominal Concrete 1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) (15.2.2) 5 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles 10 Mm To 25 Mm (15.23.1) 6 Dismantling Of Flushing Cistern Of All Types (C.I./Pvc/Vitrious China) Including Stacking Of Useful Materials Near The Site And Disposal Of Unserviceable Materials Within 50 Metres Lead. (15.52) 7 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. (15.56) 8 Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials I/C Malba All Complete As Per Directions Of Engineer-In-Charge. (14.82) 9 Dismantling 15 To 40 Mm Dia G.I. Pipe Including Stacking Of Dismantled Pipes (Within 50 Metres Lead) As Per Direction Of Engineer-In-Charge.(A) Internal Work- Exposed On Wall (14.84) 10 Dismantling C.I. Pipes Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually/ By Mechanical Means Breaking Lead Caulked Joints, Melting Of Lead And Making Into Blocks Including Stacking Of Pipes & Lead At Site Within 50 Metre Lead As Per Direction Of Engineer-In-Charge: Up To 150 Mm Diameter (15.45.1) 11 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Second Class Teak Wood (9.1.1) 12 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. (10.2) 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Weather Shade, Chajjas, Corbels Etc., Including Edges (5.9.19) 14 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers (5.9.5) 15 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. (5.22A.6) 16 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). (5.3) 17 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes (Weight Not Less Than 10 Kg Per Sqm) Fixing With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Second Class Teak Wood 30 Mm Thick (9.9.1.2) 18 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 150X10 Mm (9.97.4) 19 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 200X10 Mm (9.97.3) 20 Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 100 Mm (9.100.2) 21 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete. With 12 Mm Mild Steel U Beading (9.135.2) 22 Providing And Fixing Pre-Laminated Flat Pressed 3 Layer (Medium Density) Particle Board Or Graded Wood Particle Board Is : 3087 Marked, With One Side Decorative And Other Side Balancing Lamination Grade I, Type Ii Exterior Grade Is : 12823 Marked, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately). 18 Mm Thick (9.18.1) 23 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. : All Kinds Of Soil. (2.8.1) 24 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid (17.2.1) 25 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap (17.7.2) 26 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe: 32 Mm Dia (17.28.1.1) 27 Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. (17.29) 28 Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing : Rectangular Shape 453X357 Mm (17.32.2) 29 Providing And Fixing Toilet Paper Holder : C.P. Brass (17.34.1) 30 Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia: Centrifugally Cast (Spun) Iron Socket & Spigot (S&S) Pipe As Per Is: 3989 (17.35.1.2) 31 Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete.:100 Mm Dia: Sand Cast Iron S&S As Per Is - 3989 (17.38.1.2) 32 Providing And Fixing Plain Bend Of Required Degree. 100 Mm Dia: Sand Cast Iron S&S As Per Is : 3989 (17.39.1.2) 33 Providing And Fixing Single Equal Plain Junction Of Required Degree : 100X100X100 Mm: Sand Cast Iron S&S As Per Is - 3989 (17.44.1.2) 34 Providing And Fixing Terminal Guard :100 Mm: Sand Cast Iron S&S As Per Is - 3989 (17.56.1.2) 35 Providing And Fixing Collar : 100 Mm: Sand Cast Iron S&S As Per Is - 3989 (17.57.1.2) 36 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Fittings Of Diameter :100 Mm (17.58.1) 37 Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 (17.60.1.1) 38 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. (17.71) 39 Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. (17.72) 40 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. : 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. (17.73.2) 41 Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. (10.1) 42 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) (6.1.2) 43 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:5:10 (1 Cement : 5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) (4.1.10) 44 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) (13.1.2) 45 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) (4.1.3) 46 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Finished With A Floating Coat Of Neat Cement Of Mix : 1:4 (1 Cement: 4 Fine Sand) (13.8.2) 47 Providing And Fixing 1 Mm Thick M.S. Sheet Sliding-Shutters, With Frame And Diagonal Braces Of 40X40X6 Mm Angle Iron, 3 Mm M.S. Gusset Plates At The Junctions And Corners, 25 Mm Dia Pulley, 40X40X6 Mm Angle And T- Iron Guide At The Top And Bottom Respectively, Including Applying A Priming Coat Of Approved Steel Primer (10.4) 48 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore (18.10.1) 49 Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : 25 To 40 Mm Nominal Bore (18.13.1) 50 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 45 Cm Length: 15 Mm Nominal Bore (18.21.2.1) 51 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint With Two Coats Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work : 15 Mm Diameter Pipe (18.38.1) 52 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 15 Mm Nominal Bore (18.46.1) 53 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.: 15 Mm Nominal Bore (18.51.1) 54 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 15Mm Nominal Bore (18.53.1) 55 Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931. 15 Mm Nominal Bore (18.52.1) 56 Cutting Holes Up To 30X30 Cm In Walls Including Making Good The Same: With Common Burnt Clay F.P.S. (Non Modular) Bricks (18.76.1) 57 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. (8.31) 58 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sq.M Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. (11.38) 59 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete (13.88) 60 Factory Made 50Mmx47Mm With A Wall Thickness Of 5Mm Door Frame Pvc Extruded Sheet I/C Carriage Two Or More Coats On New Work (13.61.1) 61 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) (13.46.1) 62 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : One Or More Coats On Old Work (13.99.1) 63 Applying Priming Coat: With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood (13.50.2) 64 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes. 110 Mm Diameter (12.41.2) 65 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Single Tee With Door 110X110X110 Mm (12.42.3.2) 66 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. : Bend 87.5° : 110 Mm Bend (12.42.5.2) 67 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Shoe (Plain) :110 Mm Shoe (12.42.6.2) 68 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50X50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete. 110 Mm (12.43.2) 69 Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc (Volatile Organic Compound ) Content Less Than 50 Gram/ Litre, Of Approved Brand And Manufacturer Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour Old Work (One Or More Coats) (13.81.1) 70 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : Old Work (One Or More Coat Applied @ 0.90 Ltr/10 Sqm). (13.111.2) 71 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. (15.60) 72 Constructing Brick Masonry Road Gully Chamber 50X45X60 Cm With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including 500X450 Mm Pre-Cast R.C.C. Horizontal Grating With Frame Complete As Per Standard Design : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 (19.27.1) 73 Providing And Fixing Health Faucet With 1.2 Meter Long Flexible Tube And Wall Hook Of Cera (Code No. F1600023Cp) / Parryware Make As Per Direction Of Engineer-In-Charge. (Ns) 74 Providing And Fixing Cp Brass Overhed Rain Shower With Showerr Arm Off Approved Quality Conforming To Is Standards Cera Make Or Equivalent In Cost (Cat No F7010506Ab). With 15 Or 20 Mm Inlet: 150 Mm X 150 Mm Square Shower (Ns) 75 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. (Ns)
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (15.7.4) |
| 2 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below (15.13.1) |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) (15.2.1) |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (15.2.2) |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm (15.23.1) |
| 6 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (15.52) |
| 7 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (15.56) |
| 8 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (14.82) |
| 9 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge.(a) Internal Work- Exposed on wall (14.84) |
| 10 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: Up to 150 mm diameter (15.45.1) |
| 11 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood (9.1.1) |
| 12 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (10.2) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges (5.9.19) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (5.9.5) |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (5.22A.6) |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (5.3) |
| 17 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood 30 mm thick (9.9.1.2) |
| 18 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm (9.97.4) |
| 19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm (9.97.3) |
| 20 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm (9.100.2) |
| 21 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading (9.135.2) |
| 22 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 18 mm thick (9.18.1) |
| 23 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. : All kinds of soil. (2.8.1) |
| 24 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (17.2.1) |
| 25 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap (17.7.2) |
| 26 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe: 32 mm dia (17.28.1.1) |
| 27 | Providing and fixing 100 mm sand cast Iron grating for gully trap. (17.29) |
| 28 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm (17.32.2) |
| 29 | Providing and fixing toilet paper holder : C.P. brass (17.34.1) |
| 30 | Providing and fixing soil, waste and vent pipes : 100 mm dia: Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 (17.35.1.2) |
| 31 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.:100 mm dia: Sand cast iron S&S as per IS - 3989 (17.38.1.2) |
| 32 | Providing and fixing plain bend of required degree. 100 mm dia: Sand cast iron S&S as per IS : 3989 (17.39.1.2) |
| 33 | Providing and fixing single equal plain junction of required degree : 100x100x100 mm: Sand cast iron S&S as per IS - 3989 (17.44.1.2) |
| 34 | Providing and fixing terminal guard :100 mm: Sand cast iron S&S as per IS - 3989 (17.56.1.2) |
| 35 | Providing and fixing collar : 100 mm: Sand cast iron S&S as per IS - 3989 (17.57.1.2) |
| 36 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm (17.58.1) |
| 37 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989 (17.60.1.1) |
| 38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (17.71) |
| 39 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. (17.72) |
| 40 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. : 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (17.73.2) |
| 41 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (10.1) |
| 42 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (6.1.2) |
| 43 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (4.1.10) |
| 44 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) (13.1.2) |
| 45 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (4.1.3) |
| 46 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) (13.8.2) |
| 47 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer (10.4) |
| 48 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 15 mm dia nominal bore (18.10.1) |
| 49 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore (18.13.1) |
| 50 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length: 15 mm nominal bore (18.21.2.1) |
| 51 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 15 mm diameter pipe (18.38.1) |
| 52 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 15 mm nominal bore (18.46.1) |
| 53 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.: 15 mm nominal bore (18.51.1) |
| 54 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (18.53.1) |
| 55 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (18.52.1) |
| 56 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks (18.76.1) |
| 57 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (8.31) |
| 58 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. (11.38) |
| 59 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (13.88) |
| 60 | Factory made 50mmx47mm with a wall thickness of 5mm door frame PVC extruded sheet i/c carriage Two or more coats on new work (13.61.1) |
| 61 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (13.46.1) |
| 62 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (13.99.1) |
| 63 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood (13.50.2) |
| 64 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter (12.41.2) |
| 65 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm (12.42.3.2) |
| 66 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. : Bend 87.5° : 110 mm bend (12.42.5.2) |
| 67 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) :110 mm Shoe (12.42.6.2) |
| 68 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm (12.43.2) |
| 69 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) (13.81.1) |
| 70 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm). (13.111.2) |
| 71 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (15.60) |
| 72 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (19.27.1) |
| 73 | Providing and fixing health faucet with 1.2 meter long flexible tube and wall hook of cera (code no. F1600023CP) / Parryware make as per direction of Engineer-in-Charge. (NS) |
| 74 | Providing and fixing CP brass overhed rain shower with showerr arm off approved quality conforming to IS standards Cera make or equivalent in cost (Cat No F7010506AB). With 15 or 20 mm inlet: 150 mm x 150 mm square shower (NS) |
| 75 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (NS) |
| 76 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (NS) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender