Public Administrative Department Local Bodies Closing in 5 days TDR #56614320

Tender For Strengthening, Providing & Laying Of 800 Mm (32), 700Mm (28) & 450Mm (18) Dia Reinforced Cement Concrete Np-2 Pipes, Construction Of Mhs And Road Gullies For Smooth Disposal Of Storm Water Alongwith V-5 Road Near S Ark Centre, Sector-41A A

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
1.60 Crore
Estimated cost
Bid Submission
03 Aug 2026
5 days left
EMD
3.20 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Strengthening, Providing & Laying Of 800 Mm (32), 700Mm (28) & 450Mm (18) Dia Reinforced Cement Concrete Np-2 Pipes, Construction Of Mhs And Road Gullies For Smooth Disposal Of Storm Water Alongwith V-5 Road Near S Ark Centre, Sector-41A And From #1113 To #1500 Near Aksip School In Audit Pool Colony, Sector-41B, Chandigarh (Ch. To Capital Head: Swd System).Approx. Amount : Rs.1,60,22,494/-; Emd : Rs. 3,20,450/- ; Time Limit : 6 Months.

BOQ

Name of Work:- STRENGTHENING, PROVIDING & LAYING OF 800 MM (32), 700MM (28) & 450MM (18) DIA RCC NP-2 PIPES, CONSTRUCTION OF MHs AND ROAD GULLIES FOR SMOOTH DISPOSAL OF STORM WATER ALONGWITH V-5 ROAD NEAR S ARK CENTRE, SECTOR-41A AND FROM #1113 TO #1500 NEAR AKSIP SCHOOL IN AUDIT POOL COLONY, SECTOR-41B, CHANDIGARH (CH. To CAPITAL HEAD: SWD SYSTEM).APPROX. AMOUNT : Rs.1,60,22,494/-; EMD : Rs. 3,20,450/- ; TIME LIMIT : 6 Months.
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1:5 m in width or 10sqm or plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 100m. All kinds of soil
2Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials
3Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
4300 mm dia. (12\\") R.C.C. pipe
5300 mm dia. (12\\") R.C.C. pipe
6450 mm dia. (18\\") R.C.C. pipe
7450 mm dia. (18\\") R.C.C. pipe
8450 mm dia. (18\\") R.C.C. pipe
9700 mm dia. (28\\") R.C.C. pipe
10800 mm dia. (32\\") R.C.C. pipe
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 manufactured sand derived from recycled concrete Aggregate (RCA): 10 graded stone aggregate 40 mm nominal size Recycled aggregate (RA)
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand i/c manufactured sand derived from Recycled concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 40 mm nominal size Recycled concrete Aggregate (RCA) upto 25%)
13Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand)
1412 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1cement: 4 fine sand) Complete
15Providing orange colour safely foot rest of minimum 6mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmX25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30X20X15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
16Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
17Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 1 5° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1 :1 .5:3 (1 cement : 1 .5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
18Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
19Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal diameter.
20Providing and fixing of pre cast RCC M-20 HD Road gully cover and frames in 1:2 Cement Sand Mortar on the top of brick masonary chamber complete in all respects to the entire satisfaction of the EIC. (size of cover 690 x 537 x 80 mm and of frame is 810 x 657 x 130 mm). The work also includes removal/ dismanteling of old frame and cover including minor repairs of the road gulley if required.
21Making connection of drain or storm line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete
22For pipes 350 to 450 mm diameter
23For pipes 450 to 600 mm diameter
24Making Plug in the existing running storm line with wooden sleepers fixed with MS angle iron and GI pipe support all other contingent material required for the job to stop the flow of sewerage in downstream side the CBD.
25For pipes 200 mm to 400 mm Diameter
26For pipes 450 mm to 900 mm Diameter
27Restoration of water supply connection coming in the allignment of sewer line including the cost of GM ferrule GI pipe not less than 1.5m including all specials of 15 mm i/d with union and making connection complete in all repect.
28Restoration of existing sewer line by plugging and laying of new line of SW upto approximate 3 m and also making in working condition by putting required, bail out water, including laying, cutting and jointing etc. complete in all repect to the entire satisfaction of EIC for House connection.
29Supplying and filling of sand (recycled) under road cuts or else where, including watering, ramming, considating and dressing complete.
30Restoration of existing TT Water line by plugging and laying of new line of HDPE upto approximate 3 m and also making in working condition by putting required, bail out water, including laying, cutting and jointing etc. complete in all repect to the entire satisfaction of EIC for House connection.
31Restoration of main water supply pipe line coming in the allignment of SWD/Sewer line including the cost of Clamp/Crack including all specials for 3\\", 4\\", 6\\", 8\\" water supply lines complete in all repect.
32Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Approx 40% of total excavation as per quantity No. 1
33Carriage of material by mechanical transport including loading, unloading and stacking Complete in all respects.Approx 60% of total excavation as per quantity No. 1 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56614320
AUTHORITY Local Bodies
TENDER VALUE 1.60 Crore
LAST DATE 03-08-2026
Authority
Authority Name Municipal Corporation
Work Description Tender for Strengthening, Providing & Laying Of 800 Mm (32), 700Mm (28) & 450Mm (18) Dia Reinforced Cement Concrete Np-2 Pipes, Construction Of Mhs And Road Gullies For Smooth Disposal Of Storm Water Alongwith V-5 Road Near S Ark Centre, Sector-41A And From #1113 To #1500 Near Aksip School In Audit Pool Colony, Sector-41B, Chandigarh (Ch. To Capital Head: Swd System).Approx. Amount : Rs.1,60,22,494/-; Emd : Rs. 3,20,450/- ; Time Limit : 6 Months.
Basic Detail
Tender No 2026_MCPH1_115
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 23 Jul 2026
Submission Date 03 Aug 2026
Open Date 03 Aug 2026
Finance
Tender Value 1.60 Crore
Tender Fee 3000
EMD 3.20 Lakhs
Exemption Not Available
Document List
a5d634ed-07ba-4717-b838-8bebd12f70be.html
BOQ_115516.xls
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

a5d634ed-07ba-4717-b838-8bebd12f70be.html

xls

BOQ_115516.xls

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders