Housing Urban and Rular Development Government Departments Closing in 1 days TDR #56614141

Tender For Construction Of Type A Flat At Fisheries C Us Doranda, Ranchi

Issued by Government Departments · Ranchi, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Jul 2026
1 days left
EMD
3.22 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Type A Flat At Fisheries C Us Doranda, Ranchi

BOQ

Name of Work:- Construction of Type A Flat at Fisheries C us Doranda, Ranchi
Sl. No. Item Description
1Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I
2Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
3Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
4Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5Providing random rubble stone masonry in C.M. (1:4) in foundation and plinth with hammer dressed stone of less than 0.03 M³ in volume and clean coarse sand of F.M. 2 to 2.5 including cost of screening, raking out joints to 20 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
6Providing designation 75-B, one BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
7Providing designation 75B brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.
8Providing designation 75 A brick work in C.M. (1:3) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints,costs of screening,materials, scaffolding, raking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
9Providing designation 125 mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
10Centering and shuttering including strutting, propping etc. and removal of form for
11Foundations, footings, bases of columns, etc. for mass concrete
12Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
13Suspended floors, roofs, landings, balconies and access platform
14Columns, Pillars, Piers, Abutments, Posts and Struts
15Weathered shade, Chhajjas, corbels etc., including edges
16Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
17Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
18Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
191:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size)
201:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
21Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
22Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note:-Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately.)
23All works up to plinth level
24All works above plinth level upto floor V level
25Add for using extra cement in the items of design mix over and above the specified cement content therein.
26Providing Tor steel reinforcement for 8mm. dia rods as per approved -do- TMT Fe 500 (Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL))
27Providing Tor steel reinforcement of 10mm.,12mm & 16 mm. dia bars as per approved design and drawing -do- -do-
28(a) 10 mm (TMT coil Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
29(b) 12 mm (TMT coil Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
30(c) 16 mm (TMT coil Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
31Providing Tor steel reinforcement of 20mm, 25mm., 28mm, 32mm dia bars as per approved design and drawing -do- -do-
32(a) 20/25 mm dia TMT bar Fe 500 {Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
33Providing & fixing FAN HOOK of 16 mm dia M.S. bar, 1 M long bent to required size and shape, placed in position and fluid in the R.C.C. slab-beam at the time of casting all complete as per building specification and direction of E/I.
34Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm.
35Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I
36Supplying,fixing and fixing godrej mortice lock in flush door shutters with 4mm. transparent plastic sheet push plate 125x250mm. size on both sides all complete as per direction of E/I.
37Providing 12 mm thick waterproof cement plaster (1:3) with clean coarse sand of F.M. including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
38Providing 12mm. cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
39Providing 25mm. thick water proof cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
40Providing 6mm. Thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
41Providing 1.5 mm cement punning including curing with all leads & lifts of water, as per building specification and direction of E/I
42Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I.
43Providing two coats of SYNTHETIC ENAMEL PAINT of approved shade and make over new WOODEN surface including cleaning the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification dirction of E/I.
44Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
45For fixed portion
46Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
47For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
48Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
49Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
50With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
51Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- charge.
52With stainless steel cover plate minimum 1.25 mm thickness
53Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
54Upto 5 mm depth and 5 mm width
55Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
56Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying
57a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
58(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
59The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
60(WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
61Water proofing for Old and New Roof Slab: Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a) Surface preparation: Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equivalent. Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm × 150 mm fillet of mortar (Cement: sand – 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concrete beam slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b) 1st Coat: Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet up to 600 mm by brush or roller. After 1st coat of application, 45 gsm Fibre glass cloth to lay when the first layer is still green. 1st coat @1.5 Kg/Sqmt/coat. (c) 2nd Coat: Apply 2nd coat of two component acrylic modified ready to use cementitious material right angle to 1st coat over glass fibre. 2nd coat @0.7 Kg/Sqmt/coat. After 3 days, ponding test 48 hrs. (d) Protection of treated surface with PCC: Provide 25/50mm PCC M-20 (1:1.5:3) with slope 1:120, 2m×2m panels, 6mm gap, IS 2645 integral waterproofing. (e) Groove filling with Polysulphide Sealant (Paid separately). (Terrace)
62Providing and applying Thermoflex P-111 /Sika Coolcoat or any other Equivalent compound on Roofs of Slab as per following procedure:- (i)Surface preparation:-Surface of Roof slab should be cleaned with wire brush. Dust particle should be removed and surface should be washed with high water pressure and it should be get dried.(ii)Primer Coat:-Thermoflex P-111 should be diluted with potable water in 1:1 ratio and this Solution should be applied on cleaned and Dry surface with soft brush/ roller . (iii)1st Coat o P-111: After 3 hours of primer coat First coat of P-111 (without any dilution)should be applied with soft brush/ roller .(iv)when the 1st coat is partially dry an acrylic fiber mesh 80 GSM mat should be laid over it and pressed with roller.(v)Second /Final Coat :-2nd coat of P-111 (without any dilution)should be applied after 3 hours of 1st coat of application.It should be allowed to dry for 4 hours. Note :-There should not be any water contact on treated surface till 24 hours of final completion of treatment. (Toilet)
63Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
64Granite stone slab of all colour and texture except black,Cherry/Ruby red
65Area of slab upto 0.50 sqm
66Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
67Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
68Epoxy
69Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
7012.5 mm thick tapered edge gypsum moisture resistant board
7112 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of :
72Light shade pigment using white cement sqm 2422.80
73Medium shades pigment using 50% white cement and 50% ordinary cement sqm 2370.95
74Dark shade pigment using ordinary cement
75Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
76Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.
7725 mm diameter.
78Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
79Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
80With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
81Providing and laying vitrified Cool Roof tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 154557-2007 / 15013006, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Its solar reflective Index ( SRI ) value should be above 78. complete. Size of Tile 300x300 mm x10 mm thick.
82Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
83In 75x75 mm deep chase
84Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
85Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :
8615 mm wide and 15 mm deep groove
87Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, settingblocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter forholding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified.The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 170251. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range oftesting limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
88Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
89Granite work
90Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
91Finishing walls with textured exterior paint of required shade :
92New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
93CARRAIGE OF MATERIALS
94LOCAL SAND , LEAD - 2P+1K= 3 KM.
95COARSE SAND , LEAD - 9P+1K= 10 KM.
96STONE CHIPS , LEAD - 21P+1K= 22 KM.
97BOULDER, LEAD - 4P+1K= 5 KM.
98BRICKS , LEAD- 7P+1K= 8 KM.
99Earth carrige upto 5.0 Km
100W I R I N G
101Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
102Group C
103Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
104Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
105Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
1062 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1072 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1082 X 4 sq. mm + 1 X 4 sq. mm earth wire
1094 X 6 sq. mm + 2 X 6 sq. mm earth wire
110Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
111Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
11220 mm
11325 mm
11432 mm
115Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1165/6 amps switch
1173 pin 5/6 amp socket outlet
118Telephone socket outlet
119TV antenna socket outlet
120Bell push
121Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
122Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
123Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1241 or 2 Module (75mmX75mm)
1253 Module (100mmX75mm)
1264 Module (125mmX75mm)
1276 Module (200mmX75mm)
1288 Module (125mmX125mm)
129Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1301 or 2 Module
1313 Module
1324 Module
1336 Module
1348 Module
135Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
136Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
137Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
138Supplying and fixing brass batten/ angle holder including connection etc. as required.
139Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
140Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
141Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
142Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
143Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
144Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
145Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
146Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
147225 mm sweep
148Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
149Group C
150Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator
1518 way , Double door
152Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1534 way (4 + 12), Double door
1546 way (4 + 18), Single door
1558 way (4 + 24), Single door
156Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
1574 way (4 + 12), Double door
1588 way (4 + 24), Double door
15912 way (4 + 36), Double door
160Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
161Single pole
162Double pole
163Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
164Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
16540 amps
16663 amps
167Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
168E A R T H I N G
169Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
170Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
171Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
172Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
173Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
174L I G H T N I N G C O N D U C T O R
175Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
176Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductorcomplete as required.(For horizontal run)
177Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductorcomplete as required.(For vertical run)
178Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
179WIRING FOR LOW VOLTAGE OUTLETS
180Supply, Drawing and Testing of 4 pair ,100 Ohm, 24 AWG UTP Cat 6 Cable as per latest amendments of TIA / EIA 568 B.2 specifications for Data / Telephone points in existing MS /PVC conduits including making connections to Information outlets and patch panels with ferruling at both ends for identification with necessary tools for punching ,stripping crimping and testing as required
181Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require
182White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
183Providing and fixing , kitchen sink without drain boad 610 X 510 mm bowl depth 200 mm C.I. Brackets, C.P. Brass chain with rubber plug, 40mm C.P brass waste and 40 mm C.P. Brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the walls wherever required.
184Providing and fixing white vitreous china pedestal type (European type / wash down type ) waster closet pan.
185Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
186Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
187Providing and fixing P.V.C. waste pipe for wash basin including P.V.C. waste fittings complete.
188Semi rigid pipe
18940 mm dia
190Providing and fixing 100 mm sand cast Iron grating for gully trap.
191Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
192Providing and fixing toilet paper holder :
193C.P. brass
194Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
195100 mm inlet and 100 mm outlet
196Sand cast iron S&S as per IS - 3989
197Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :
198100 mm dia
19975 mm dia
20050 mm dia
201Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
202Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet
203150 mm dia
204C.P.V.C. PIPES
205Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
206Internal work
20720 mm nominal outer dia Pipes
20825 mm nominal outer dia Pipes
20940 mm nominal outer dia Pipes
210Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge
211Concealed work, including cutting chases and making good the walls etc.
21220 mm nominal outer dia Pipes
213Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
214External work
21525 mm nominal outer dia Pipes
21640 mm nominal outer dia Pipes
217BRASS FITTINGS
218Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
21920 mm dia nominal bore
22025 mm dia nominal bore
221Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
22225 mm dia nominal bore
223Providing and fixing uplasticised PVC connection pipe with brass unions :
22430 cm length
22515 mm nominal bore
226C.P. BRASS FITTINGS
227Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
22815 mm nominal bore
229Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
23015 mm nominal bore
231Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
23215 mm nominal bore
233Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
23415mm nominal bore
235Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
236Cutting holes up to 30x30 cm in walls including making good the same:
237With common burnt clay F.P.S. (non modular) bricks
238Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
239Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc.
240200/150 MM DIA. DEEP BOREWELL
241200/150 mm dia Deep borewell : Cost of drilling 200 mm X 165 mm X 125m deep brewell in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH Rig machine, all complete including supplying all all materials, tools drilling rig, Air compressure and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicle up to the site.
242(a) From 0.00 M to 50.00 M below G.L
243(b) From 51.00 M to 125.00 M below G.L
244(c) From 125.00 M to 200.00 M
245Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
246200mm Nominal size dia.
247Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
248Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm Dia.
249Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
250Supplying 100mm dia. Submersible pump sets confirming to IS 8034 and motor cvonfirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft ant polypropylene/ norylimpeller. Motor suitable for working on 415 V+10%, 3PH, 50 HZ, AC supply with cable guard, thurst carbon/ fibre bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined no return valve shall be provided with pump. 3 m submersible copper conductor cable in single/ double run and nylon rope as required length shall be provided with each pump.
251Submersible pump set 100mm dia (with polypropylene/ Noryl Impeller)
252Supplying and fitting of standared make starter pannel board with arrangement of all necessory protection ,including all taxes , royalty etc all complete job as per direction of E/I 5 HP TO 10 HP
253Supplying ,fitting & fixing & connecting 3 core 4 sqmm flat copper submerssible cable of Finolex / Hevels make including all taxes ,royalty etc all complete job as per direction of E/I
254Supplying and laying /lowering of GI pipe of 50 mm dia including of required fittings solvent etc complete job as per direction of E/I
255Sevices and Accessories on Building
256Fire Fighting
257Fire Hydrant System
258Supply, Installation, Testing & Commissioning of: Single headed, SS/ Gun Metal ISI marked oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63mm dia instantaneous type female outlet complete with Gun Metal cap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type 'A')
259Supply, Installation, Testing & Commissioning of: First-Aid Fire Hose Reel wall mounting swinging type complete with drum, bracket, ball valve and 20mm dia.x 30M long high pressure Hose Reel tubing as per IS:444 with Gun Metal shut-off nozzle having 5mm dia. orifice. The Hose Reel shall strictly confirm to IS : 884-1985
260Supply, Installation, Testing & Commissioning of: Non-percolating flexible hose (RRL type-'A') ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneous type SS/ Gun Metal 63 mm dia. IS marked Male and female couplings (IS:903) bound and riveted to hose pipe with Gun Metal rivets and 1.5 mm Gun Metal wire
261Supply, Installation, Testing & Commissioning of Gun Metal Fire Brigade connection (Suction collecting head) consisting of 63 mm dia instantaneous type male coupling with built-in check valves and 150 mm dia. flanged outlet complete with bolts, nuts and rubber insertions as required as per IS:904-1983
262Two Way
263SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) heavy class including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work.
264150 mm dia IS 1239
265100 mm dia IS 1239
26680 mm dia IS 1239
26750 mm dia IS 1239
268Supply, Installation, Testing & Commissioning of slim seal dual type non-return valves (PN 1.6) complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes.
269150 mm dia
270Providing and fixing Slim seal Butterfly valves (PN 1.6) complete with matching flanges rubber insertion, nuts. bolts and washer etc. of following sizes
271150 mm dia nominal bore
272FIRE PUMPS, VALVES & ACCESSORIES
273Supply, Installation, Testing & Commissioning of cubical type wall mounted Fire Pump Control Panel (For Terrace Pump at Roof) with One Fully Automatic DOL Starter suitable for 900 LPM Pump Motor with over load relay, timer push buttons and Auto/Manual selector switch.
274NON SCHEDULE ITEMS
275Supply & Installation of RJ-45 Information outlets Jack ABS FR grade with spring loaded collapsible shutters in jack recess suitable for Cat 6 application with terminator caps for tooless termination .
276Single Outlet
277Supply , Installation and Testing of 4 pair , 100 Ohm, 24 AWG , Cat 6 UTP, flexible , Double ended Patch Cords along with 2 No of RJ 45 connectors with strain relief transparent boots as per TIA /EIA 568 B.2-1 Specifications.
2781 Mtr/3 ft
279SITC of 10/100 MBPS Unmanaged Switch
2808 Port
281Supply , Installation, Testing and Comissioning of Rack mounted 19\\", Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps.
2828 Port Patch Panel
283Supply , Installation, Testing and Comissioning of Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, one Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable .
2846U(44 mm ) wall mounted
285CCTV & SURVEILLANCE NETWORK
2862 Megapixel Fixed Lens Camera IR Dome Type: 1/2.8\\"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8mm Fixed lens, 0.028 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, IK10, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, video tampering, UL, CE, FCC certified.
2872 Megapixel Fixed Lens Camera IR Bullet Type: 1/2.8\\"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified.
288NVR 32 Channel: Connect Up to 16 IP Cameras, Dual OS, Up to 8 Megapixels Resolution, HDMI output with 4k output and VGA output with 2MP Output , Support H.265,H.264, MJPEG, Incoming Bandwidth 160 Mbps, 4 SATA Hard Disks, ANR Technology, 2 SATA interfaces for 2 HDDs and capacity of each HDD upto 6TB, 2 USB at least 1 × USB with 3.0, Serial interface:1 RS-485, 1 RS-232, Alarm I/O 16/4, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified.
289NVR 32 Channel: Connect Up to 16 IP Cameras, Dual OS, Up to 8 Megapixels Resolution, HDMI output with 4k output and VGA output with 2MP Output , Support H.265,H.264, MJPEG, Incoming Bandwidth 160 Mbps, 4 SATA Hard Disks, ANR Technology, 2 SATA interfaces for 2 HDDs and capacity of each HDD upto 6TB, 2 USB at least 1 × USB with 3.0, Serial interface:1 RS-485, 1 RS-232, Alarm I/O 16/4, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified.
2908 Port Network Switch POE: 16 × PoE ports, 1 × RJ45 port, and 1 × SFP fiber optical port, IEEE 802.3at/af standard
29116 Port Network Switch Gigabit POE: 16 × gigabit PoE ports, 1 × gigabit RJ45 port, and 1 × gigabit SFP fiber optical port, IEEE 802.3at/af standard
292CAT 6 Connector
293Hard Disk 6 TB
294Suplly & installation of Computer system as required
295Installation/labour charges
296Supply, Drawing and Testing of 4 pair ,100 Ohm, 24 AWG UTP Cat 6 Cable as per latest amendments of TIA / EIA 568 B.2 specifications for Data / Telephone points in existing MS /PVC conduits including making connections to Information outlets and patch panels with ferruling at both ends for identification with necessary tools for punching ,stripping crimping and testing as required
297Supply and laying of HDMI Cabel
298Supply and Laying of RIGID PVC Medium Duty Conduits ISI marked conduits complete with accessories such as bends, junction boxes, pull boxes etc., in recess or on surface including cutting chases in the walls/floors and making good the same complete as required.
29932 mm dia
30025 mm dia
301INTERNAL LIGHTING FIXTURES
302Providing of IP20 LED batten type light fixture made from CRCA sheet steel housing suitable for moutning LED tube system (integral driver), Power Consumption of 18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K & 6000°K..
303Providing of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. Power Consumption of ≤ 15W / 18W with ~ 1100 / 1250 lumens, System Lumen efficacy of 70 lm / watt output suitable to replace 1x18W / 2x18W / 2x 26W CFL Downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintaned. CCT 3000°K , 4000°K & 6000°K. Fixture shall be CE compliance. Note:- fixture Wattages are
304Provide of Aesthetically Designed linear LED mirror light with a high output PMMA Diffuser for glare free output including making connection testing etc. as required Dimension-300mm
30512 Watt LED LAMPS
306Provide of Heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required. 300 mm Sweep 9 900 RPM)
307Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
308Provide & Fixing of capacitor start, wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required.
309400 mm sweep( oscillating type)
310MV CABLES & TERMINATION
311Supply,Laying/drawing of XLPE insulated & sheathed cable of 1.1 kV grade with Copper/ Aluminium conductor of approved makeon wall / Cable Tray with GI Saddles ,making necessary connections including testing etc. as required
31216.00 Sq.mm 4.0 core armoured Al. Cable
313CABLE TERMINATION
314Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Al.Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.
31516.00 Sq.mm 4.0 core armoured Al. Cable
316Supply, Installation, Testing & Commissioning of LT Panel of cold rolled sheet metal construction, floor mounting, free standing, totally enclosed, dust and vermin proof conforming to IP42 degree of enclosure protection with base channel . The panel shall be as per IEC-61439 Type Tasted Assembly type panel.
317SITC of cubical panel made out of CRCA sheet, required hardware, duly painted by either two coats of zinc/ red oxide primer followed by two coats of synthetic enamel paint or powder coating in grey or required shade after rinsing . The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . 3 mm thick sheet for gland. Side walls and cable alley compartments having bolted type doors. double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof with not less than IP-42 (For Indoor Type) Protection.
318Note: Panel Shall be Floor Mounted . Panel cable Entry & Exit from Bottom . MCCB are T/M, O/L.S/C, Ics=100%Icu
319Note :- Panel shall be made according to panel sld.
320INCOMER
321MCCB125Amp FP 36 KA ,T/M, with ROM & Spredders, 1No.
322Indicating Lights(Phase-R,Y,B,Contactor Open,Close) 5No.
3236 amps Protective SP MCB’s , 4 Nos.
324OUTGOING
32563A. FP, MCCB, 10kA - 5 Nos
32640A. FP, MCCB, 10kA - 2 Nos
327Bus Bars
328125amps ,TPN,Electrolytic high conductivity Aluminium busbar with colour coded heat shrinkable insulating sleeves.
329Miscellaneous
330Missll.( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, PVC Channel , MCB Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material )
331PANELS FOR PUMPS
332Design, manufacture, supply, installation, testing & commissioning of the following cubicle type weather proof(IP-67), dead front, sheet steel, wall/floor mounted control panels, including anchoring into the wall, wiring terminating from bottom into MCB & earthing, in each panel shall be provided by the electrical contractor.
333All wiring & copper earthing of motors from panel shall be included.
334The panel shall be include the following components & accessories.
335MCB as per the ratings given bellow, suitable for motor duty and able to withstand fault level of 20KA.
336DOL / SD starter as per HP rating
337Terminal block for power distribution as required.
338Contactor, overload relay with built in single phasing protection (only for DOL & S/D starter)
339Phase indicating lights & indicating light for 'ON'/ OFF status.
340Digital voltmeter & digital ammeter with selector switches.
341Time delay relay for delayed automatic restart of motor.
342Wiring for microswitch for stoping the fan at the time of fire
343Remote start & stop facilities to be provided for each panel
344The number of starter shall be as follow HP rating:-
3451 HP starter for Booster Pump (Three Phase )
346SOALR PHOTOVOLTAIC POWER PLANT
347Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 500 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolarPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak wattcapacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along withsupplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
348(For Internal Drainage Works)
349Providing and fixing uPVC RWP pipes (IS: 13592 Class B Heavy Type) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with rubber ring/solvent cement joints,clamps including cutting chase or holes in walls and floors and making good where required.(for rain water pipe inside the building)
350110 mm dia.
35175 mm dia.
352Providing and fixing uPVC soil, waste and vent pipe (IS: 13592 Class B) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with solvent cement/rubber rings, including pipe support/angle/channels from ceiling, including cutting chase or holes in walls and floors and making good where required.
35340 mm dia
35450 mm dia
35575 mm dia
356110 mm dia
357Providing and laying cement concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm and down gauge) 75 mm in bed and all round C.I. pipes / UPVC pipes.
358150/100/75/50/40/32 mm dia soil & waste pipes under floor including shuttering and centering.
359Providing & fixing in position SWR PVC P\\", S\\",Nanhi trap of self cleaning design of following sizes for the embedded areas. Making proper connection with , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required.
360110 mm inlet and 110 mm outlet. (Floor traps, P- type only)
361110 mm inlet and 75 mm outlet (Nanhi Trap)
362Providing and fixing Cast bronze chrome plated grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar
363125 mm dia
364Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size).
365Fixing in position special angle supports for hanging/Vertical pipes fittings with fastners.Complete as per requirement.
366Cutting holes in walls and core cutting in R.C.C. floors/slab and roofs/beams(100mm to 300mm thick R.C.C) for passing drainage/water supply pipe etc. and repairing the hole after insertion of drainage/water supply pipes etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), water proofing chemical, grouting etc. including finishing complete so as to make it leak proof.
367For 75mm dia
368For 110mm dia
369For 160mm dia
370Providing & fixing brass/ gun metal lever operated ball valve. Tested to a pressure of 15 Kg / Sqcm. Including flanges/union, nuts, bolts, washer etc. Complete as required.
37125 mm dia
37240 mm dia
373Supply,fixing of storage type horizontal electric water heaters of different capacities including brackets, screw and other arrangements complete in all respect.
37410 ltrs. Cap.(vertical)
37515 ltrs. Cap.(vertical)
376Supply, Installation, Testing & Commissioning of: SS/ Gun Metal 63mm dia short size branch pipes with 20 mm dia nozzle with 63mm instantaneous coupling ISI marked (IS: 903)
377Providing & fixing standard fireman's axe with heavy insulated rubber handle.
378Supply, Installation, Testing & Commissioning of:M.S. hose door fabricated from 16g M.S. sheet with full glass door and locking arrangement, suitable to accommodate 1 Hydrant landing valve, 1fire hose reel, 2 nos.15m long 63mmdia hose,1-branch pipe. The door shall be painted with one coat of primer and finished stove enamelled \\"Fire Red\\", \\"Fire Hose\\" written on front including suitably mounted on a raised masonry platform as required. (Approx. size 1.2m x .6m x 2.1m )
379Supply, Installation, Testing & Commissioning of: Air cushion tank (air-vessel) 250 mm dia. x 1.0 M high with dished top, made of minimum 6 mm thick M.S. pipe/plate complete with 25 mm dia. Brass Air Valve (Ball valve, pressure gauge type), 25 mm dia. Stop with brass stop cock, nipple, tees, elbow, pipe and all accessories as required incl. fixing brackets.
380PORTABLE CHEMICAL FIRE EXTINGUISHERS
381Supply and fixing of ISI marked ( IS : 15683 ) ABC (Dry Powder) fire extinguishers cap 10 kg (9Kg) in seamless HP steel cylinders ISI marked and approved by CCE Nagpur fitted with pressure indicating gauge, internal tube squeeze level type valves fully charged with ABC powder and pressurized by Nitrogen complete in all respects including wall suspension bracket.
382Supply and fixing of ISI marked (IS:2878) Portable fire Extinguisher, Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1m long & complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling ratio of not more than 0.667and wall suspension bracket.
383Capacity 4.5 Kg
384Add GST 18 %
385Add Labour cess 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56614141
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-07-2026
Authority
Authority Name Jharkhand State Building Construction Corporation Limited
Work Description Tender for Construction Of Type A Flat At Fisheries C Us Doranda, Ranchi
Basic Detail
Tender No JSBCCL/48/2026-27
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 22 Jul 2026
Submission Date 31 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 10000
EMD 3.22 Lakhs
Exemption Not Available
Document List
321cfe9d-72d2-4376-a805-2b03511b1fdd.html
BOQ_157354.xls
SBD48.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

321cfe9d-72d2-4376-a805-2b03511b1fdd.html

xls

BOQ_157354.xls

pdf

SBD48.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender