Public Administrative Department Local Bodies Closing in 16 days TDR #56613591

Tender For Repair And Maintanance Of General Section And Council Hall At Zone 4 Office In Ward No.56 In Zone-4

Issued by Local Bodies · Chengalpattu, Tamil Nadu
Tender Value
9.90 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
16 days left
EMD
9900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintanance Of General Section And Council Hall At Zone 4 Office In Ward No.56 In Zone-4

BOQ

Name of Work:- Repair and Maintanance of General Section and Council Hall at Zone 4 Office in Ward No.56 in Zone-4
Sl. No. Item Description
1Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\\" X 43/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT
2Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
3Painting two coats of newly plastered wall surface with ready mixed Cement paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification.
4Suppling and fixing in position 15mm diameter brass / C.P screw down tap / pillar tap / swan neck tap (heavy duty) of approved make conforming to I.S.specifications and quality including cost of shellac, thread etc.complying with standard specifications and including cutting and threading wherever necessary
5Supply and fixing of PVC. Nahini / Floor Trap with stainless Steel Gratings - 100 mm x 75 mm including all charges etc, complete as per standard specification.
6Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
7Supply and fixing of single box type 4'36 W flu fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting Sd 87
8Supply and fixing of 1200 mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp. SD 110
9Supplying, fabrication and fixing in position of aluminuium natural colour matt finish Aluminium Three Track window of size 1.80m x 2.10m half glazed and half plb board fully 12mm thick board fully 5.5mm thick glazed door using rectangular aluminium box section of following sizes of frames and shutters with necessary accessories such as rubber beading, aluminium clips, best double action floor spring door closeer, handle locks and glass including all materials labour and power consumption charges required for fabrication if necessary chiopping dismantling making necessary holes in RCC columns, beams or masonary wherever necessary with power drill to the extent required and made good to the original conditions after fixing etc., complete. The aluminium surface must be anodised with matt finish under electrically controlled condition in accordance with IS specifications 1868/1962 of anodic film thickness of not less than 15 microns for all sections. All the materials should be got approved by the Engineer in charge before fixing as directed
10Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
11Supplying and fixing of Granite Sink of size 600 x 600 x 250mmLipped Mouth Porcelain Flat Back Urinal with all accessories such as 32mm dia Bell Mouth PVC Connection, 15mm diaGM Wheel Value, 15mm dia ‘B’ Class GIWaste Water Pipe, 15mm dia Nylon Connection, 15mm dia Brass Nipple etc.
12Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall becovered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter
13Wiring 2 x 1.50 sqmm (22/0.3) PVC insulated Sc unsheathed Cu.Conductor of 1100 V grade in suitable pvc rigid pipe consealed in wall and ceiling with PVC accessories in flush with wall with 3 mm thick hylumw sheet cover with TW Switch box and 5 A FT switch with coninious earth wire connection for light point and Fan point as per SD 22
14Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification.Theframeusingaluminium tubular section of size 50mm x 25mm x2mm thick fixing horizontally and vertically in position withwall at interval of 0.60m in both diretions, fixing waterproof plywood of 12mm thick over the aluminium framework with necessary screws. One side teak wood sheet of3.5mm thick will be fixed over the plywood using fevical andfinishing with melamine polishing and the rate inclusive ofconveyance to site and labour charges and as directed by the Departmental Officers. The design pattern,waterproofplywood, OST sheet and other materials to be used shall begot approved by the Executive Engineer concerned beforeuse on work etc., complete.
15Supply and delivery INSTALLATION OF AIR-CONDITIONER WITH COPPER COIL 1.5 TR Split Type AC Unit - 5 Star Rated including cost and Conveyance of all Materials and all Labour Charges etc., Completed
16Supplying and fixing of Vivre wooden pvc panel panel 18mm thick approved over the 60mmx60mm aluminium frame with all necessary fittings which is including all materials and cost of conveyance charges etc complete with complying standard specification. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56613591
AUTHORITY Local Bodies
TENDER VALUE 9.90 Lakhs
LAST DATE 11-08-2026
Authority
Authority Name Directorate Of Municipal Administration
Work Description Tender for Repair And Maintanance Of General Section And Council Hall At Zone 4 Office In Ward No.56 In Zone-4
Basic Detail
Tender No 925/2026/E1/Z4(11.08.2026)
Bidding Type Tender
Location
City Chengalpattu
State Tamil Nadu
Key Dates
Publish Date 23 Jul 2026
Submission Date 11 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 9.90 Lakhs
Tender Fee Ref. Documents
EMD 9900
Exemption Not Available
Document List
bb2affef-f5e7-41ff-8ed1-1f273219a36e.html
BOQ_826903.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

bb2affef-f5e7-41ff-8ed1-1f273219a36e.html

xls

BOQ_826903.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders