Tender For Repair And Maintenance Of Existing Panel And Power Supply Cable Of Nalapar Sfa Type-I/Qtr No From (01 To 68) Paloura C Us Ftr Hq Bsf Jammu.
Tender Value
5.17 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
4 days left
EMD
10346
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Existing Panel And Power Supply Cable Of Nalapar Sfa Type-I/Qtr No From (01 To 68) Paloura C Us Ftr Hq Bsf Jammu.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and laying of following 3.5X50 sqmm one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor,armoured underground cable as per IS 7098 (Part-I) 1988 with upto date ammendments of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering (Make:Havells/Polycab/Fenolex/L&T/RR Cabal make) |
| 2 | Supplying and laying of 3.5X50 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/FInolex/L&T/RR Cabal make) |
| 3 | Providing and fixing of Switch Disconnector Fuse Open Execution (QSA - Series) Conforms to IS-13947 - Part I & III / IEC-947 Part I & III, AC-23A, 415V, 50 Hz, 100Amps. Rating, in the existing panel connection testing and commissioning etc as required. (Make: HPL/Havells/Legrand/ABB/Anchor/L&T/Schneider make) |
| 4 | Providing and fixing of Switch Disconnector Fuse Open Execution (QSA - Series) Conforms to IS-13947 - Part I & III / IEC-947 Part I & III, AC-23A, 415V, 50 Hz, 250Amps. Rating, in the existing panel connection testing and commissioning etc as required. (Make: HPL/Havells/Legrand/ABB/Anchor/L&T/Schneider make) |
| 5 | Repairing of existing complete meter box panel having set of 04 Nos Qtrs each, cleaning, removing of existing burn/defective cables, dismantling of existing switches, priming and painting of panel, fixing of panel cover connection of existing cables, repairing of existing cable connection including connection of incoming cable and outgoing submain etc. as required. |
| 6 | Repairing of existing out-door panel cleaning, removing of existing switches, burn/defective cables, excavation of nearly panel and to check the Loop i/c Providing and fixing of back side MS Sheet cover 2.0 mm thick size 1.0 Sqm suitable for existing panel, priming and painting of panel, connection of existing cables after repairing etc. as required. |
| 7 | Supplying and laying of 3.5X35 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/Finolex/L&T/RR Cable make) |
| 8 | Supplying and laying of 3.5X120 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/Finolex/L&T/RR Cabal make) |
| 9 | Providing and fixing of Single Phase kWh meter two wire static electronic meter with LCD display, 1P LCD Meter 5-30A, Fixing in the existing panel connection etc. as required. (Make : Cat. No. L&T/Seimens/HPL Make) |
| 10 | Providing and fixing of TPN MCB 'C' Curve 63Amp. Fixing in the existing panel connection etc. as required. (Make : Cat. No. Havells/Schneider/L&T/ABB/BCH/C&S Make) |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Single pole and neutral (Make Havells/L&T/Legrand/ABB/BCH/C&S) |
| 12 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm |
| 13 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender