Tender For Maintenance And Repairs To Capacitor Panels Renewal Of Earthing System & Other Allied Works At Afac Under Age(I) Af Coimbatore
Tender Value
9 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
23 days left
EMD
18000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance And Repairs To Capacitor Panels Renewal Of Earthing System & Other Allied Works At Afac Under Age(I) Af Coimbatore
BOQ
| Sl. No. | Item Description |
| 1 | M&L for repair/servicing of capacitor panel 25 KVAR/30 KVAR/50 KVAR/125 KVAR and increase the existing capacity of capaciter with replace the capaciter and contactor suitable to accomodate in existing panel and carry out repairs such as dismantling of power contactros, auxillary contactors, CT Coil, checking the HRC fuse and replacement if any damaged, checking the control wiring and refixing all the components after proper servicing all as specified and as directed Note: Spare parts any required will be measured separately) |
| 2 | Supply only 5 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand |
| 3 | Supply only 10 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand |
| 4 | Supply only 15 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand |
| 5 | Supply only 30 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand |
| 6 | Supply only 40 KVAr capacitor duty contactors with built in surge suppressor and NO/NC . Make : L&T, Havells, Schneider, Legrand Note - Sl NO 2 to 5 The contactor frame size suitzble to mount existing capaciter panel |
| 7 | Supply only 20 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection complete. Make : L&T, HPL, Havells, Schneider, C&S |
| 8 | Supply only 15 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 9 | Supply only 10 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 10 | Supply only 7.5 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 11 | Supply only 5 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 12 | Supply only 4 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 13 | Supply only 3 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 14 | Supply only 2 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 15 | M&L for servicing of LT Panel board double door with canopy by cleaning with blower/replacement of lugs if any, replacemenmt of burned out copper wiring if any, cleaning and tightening of MCCB terminal connections, rectifying the loose connections, repairing of door locking arrangement including hinges or welding where required including marking the incomming/outgoing feeder name with label marker machine all as specified and as directed. |
| 16 | Supply and fix MCCB four pole 160A, 36 KA, 415 V, adjustable type suitable to existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siements/Indo asian/Havells /Schnieder |
| 17 | Supply and fix MCCB four pole 200A, 36 KA, 415 V, adjustable type suitable to existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siemens/Indo asian/Havells /Schnieder |
| 18 | Supply and fix MCCB four pole 250A 36 KA 415 V, adjustable type suitable to existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siements/Indo asian/Havells /Schnieder |
| 19 | Supply and fix MCCB 3 pole 25-100 Amps, 16 KA, 415 V, fixed type suitable to existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siements/Indo asian/Havells /Schnieder |
| 20 | Supply and fix 415 V 10 KA 'C' Curve miniature circuit breaker (MCB) of TP 25 to 63 Amp and current carrying capacity in the DB/LT Panel complete with connection testing and commissioning including taking down unserviceable MCB's all as directed. Make: C&S/ Siemens/Indo asian/Havells/Schnieder |
| 21 | All as per Item No 20 here-in-before but TPN 16 to 32 Amp capacity |
| 22 | All as per Item No 20 here-in-before but TPN 40 to 100 Amp capacity |
| 23 | Supply fix 415 V 10 KA 'B' Curve miniature circuit breaker (MCB) of TP 25 to 63 Amp and current carrying capacity in the DB/LT Panel complete with connection testing and commissioning including taking down unserviceable MCB's all as directed.Make: C&S/ Siemens/Indo asian/Havells/Schnieder |
| 24 | All as per Item No 23 here-in-before but TPN/FP 16 to 32 Amp capacity |
| 25 | All as per Item No 23 here-in-before but TPN 40 to 100 Amp capacity |
| 26 | Material and labour for painting of steel/iron surfaces of any description over 10 cm in width or girth or length with cleaning, preparation of old painted surfaces and two coat of aluminium paint of Gates and open palisade fencing, chain link fincing including standards. braces, rails. stays poles etc all as specified and as directed. |
| 27 | Material and labour for painting of steel/iron surfaces of any description over 10 cm in width or girth with cleaning, preparation of old painted surfaces and two coat of Synthetic enamel paint of Gates and open palisade fencing, chain link fincing including standards. braces, rails. stays etc all as specified and as directed. |
| 28 | S&F in replacement of panel mounted LED phase indication lamp (Red,yellow,Blue ,Green colour) operating voltage 220 to 240 volts suitable for fixing in the LT panel all as specified and as directed. Make L&T/AE/Simens or equivalent |
| 29 | Supply and fixing voltmeter three phase 415 volts flush mounted type 96 x 96 mm with inbuilt selector switch class 0.5 accuracy, measurement range 50 to 520 volts AC with AC aux supply port including taking down unserviceable meter all as directed Make L&T, AE, Elmeasure |
| 30 | Supply and fixing ammeter three phase 415 volts flush mounted type 96 x 96 mm with inbuilt selector switch class 0.5 accuracy, CT secoundry range 5 amps of existing CT ratio with AC aux supply port including taking down unserviceable meter all as directed Make L&T, AE, Elmeasure |
| 31 | Supply and fixing 200 Amp, 4 Pole, 415 Volts, 50 Hz open executions on load mannual change over switch conforms to IEC-609473 with all accessories required for fixing in existing LT panel board complete. |
| 32 | Supply and fix APFC controller eight stage single CT operated size 96 x 96 mm contactor switching three phase current and volatage measurment, auto/manual mode selection, individual PF setting system operating volatge 110 to 440 volts suitable to exsisting APFC panel including taking down unsderviceable controller all as directed Make - L&T, Havells, Elmeasure, AE |
| 33 | Supply and fix automatic mains/stand by supply control funtional relay with Aux supply provision with following measuring parameters three phase mais/DG voltage current frequency, KW, speed, run hours, logical inter locking facility, engine safety functions LLOP,HOT, start/stop failure,OLP function with LED display including taking down unserviceable mains controller all as specified and directed Make - C&S, Nakoba, L&T, Simens |
| 34 | M & L for earth pit Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, with flush type handle with 16mm dia round bars all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and two coat of syntahtic enamel panit red colour in chamber and cover over a coat of primer with preparation unpainted surfaces, marking on earth pit covers with two inch height letters in white colour paint all as specified or indicated. Note (i) PCC chamber shall be provided 50cm away from the plinth of building. (ii) Any damage in existing items during the time of excavation rectify/replace the same without any extracost. (iii) The cost of taking down the old pit covers deamed to be included in quated rate . |
| 35 | Supply and fix earth continuity conductor or main earth lead fixed to wall on battern/recess/ chases or buried in ground or drawn through conduit/pipe/porceline insulators or any other indicated situation for 25 Sq mm single core copper conductor XLPE insulated unarmoured cable all as directed |
| 36 | M&L for dismantling / cutting of existing road / path / hard standing cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) suitable for laying earth lead any type any dia under the road / path / hard standing complete. |
| 37 | Material and labour for PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) for making good the disturbed surface of road/path/hard standing by using cement contrete mortar 1:2:4 type B1, using 40 mm graded stone aggregate 0.45 mtr wide and 0.15 mtr thick complete all as specified and directed. including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge. |
| 38 | Material and labour for test point terminal block made of gun metel or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25 mm long hex head screw all as directed |
| 39 | Supply and fix PVC rectangular box with hinged door cover suitable for fixing the test point of size 155x155x95/100 mm all as directed |
| 40 | Supply and fix PVC insulated cable 3 core flat copper conductor (including jointing material) size 6 Sqm 1100 Volt, confirming to IS 694- 1940 complete in cluding taking down unserviceable cable all as directed . |
| 41 | Supply and layig, connecting, testing and commissioning of 120 Sqmm 3.5 Core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable confirming to IS : 7098-1985 with stranded aluminium conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe, duct or along the pole and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed. Make: Havells/Polycab/Finolex/ Paragon/Gloster/Nicco |
| 42 | All as per Item No 41 here - in - before but 95 Sqmm 3.5 core complete. |
| 43 | All as per Item No 41 here - in - before but 70 Sqmm 3.5 core complete. Supply and lay reinforced precost concrete cable cover class LV type 1 flat size 250 x 180x 40 mm all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysAug 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender