Defence Statutory Bodies & Commissions/Committees Closing in 26 days TDR #56612798

Tender For Repair/ Maintenance Of Unsv/ Damaged Lt Switchgear At Tech Area And Replacement Of Outdoor Lt Panels In Omq, Smq Area And Repair/ Maintenance Of Vcb, Rmu And Allied Works At Tech Area, Mrs, Smq Area And Omq Area At Af Stn Hasimara Under Ge

Issued by Statutory Bodies & Commissions/Committees · Jalpaiguri, West Bengal
Tender Value
60 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
26 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Unsv/ Damaged Lt Switchgear At Tech Area And Replacement Of Outdoor Lt Panels In Omq, Smq Area And Repair/ Maintenance Of Vcb, Rmu And Allied Works At Tech Area, Mrs, Smq Area And Omq Area At Af Stn Hasimara Under Ge (Af) Hasimara.

BOQ

Name of Work:- REPAIR/ MAINT OF UNSV/ DAMAGED LT SWITCHGEAR AT TECH AREA AND REPLACEMENT OF OUTDOOR LT PANELS IN OMQ, SMQ AREA AND REPAIR/ MAINT OF VCB, RMU AND ALLIED WORKS AT TECH AREA, MRS, SMQ AREA AND OMQ AREA AT AF STN HASIMARA UNDER GE (AF) HASIMARA.
Sl. No. Item Description
1Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender documents & all corrigendum/amendments and general condition of contracts before entry/quoting the rates.Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
2S&F on load change over switch 400 Amp with sheet metal enclosure including source seperator/phase barrier including providing new thimble/lugs of suitable size and taking down old unserviceable, complete all as specified and directed.
3S&F on load change over switch 200 Amp with sheet metal enclosure including source seperator/phase barrier including providing new thimble/lugs of suitable size and taking down old unserviceable, complete all as specified and directed.
4S&F on load change over switch 160 Amp with sheet metal enclosure including source seperator/phase barrier including providing new thimble/lugs of suitable size and taking down old unserviceable, complete all as specified and directed.
5S&F on load change over switch 100 Amp with sheet metal enclosure including source seperator/phase barrier including providing new thimble/lugs of suitable size and taking down old unserviceable, complete all as specified and directed.
6S&F in replacement power contactors for LT panel after dismatling existing contactors from panel and connecting new contactors and making connection with incoming and outgoing MCCB including auxiliary acceessories and control wiring complete all as specified and as directed for following ratings.
73 pole Power contactors , 40 Amp , ML- 3 ,2 NO+2 NC
83 pole Power contactors , 70 Amp , ML- 4 ,2 NO+2 NC
93 pole Power contactors , 110 Amp , ML- 6 ,2 NO+2 NC
104 pole Power contactors , 200 Amp , MCX 33 ,2 NO+2 NC
114 pole Power contactors , 400 Amp , MCX 43 ,2 NO+2 NC
124 pole Power contactors , 700 Amp , MCX 46 ,2 NO+2 NC
13S&F of MCCB 630 Amps AC 4 pole 415 Volt 50 KA breaking capacity with thermal magnetic release range 500-630 Amp, Ics= 100% Icu including providing new thimble / lugs of suitable size and taking down old unserviceable complete all as specified and directed.
14S&F of MCCB 400 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 320-400 Amp , Ics= 100% Icu including providing new thimble / lugs of suitable size and taking down old unserviceable complete all as specified and directed.
15S&F of MCCB 350 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 250-350 Amp, Ics= 100% Icu including providing new thimble / lugs of suitable size and taking down old unserviceable complete all as specified and directed.
16S&F of MCCB 250 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 200-250 Amp, Ics= 100% Icu including providing new thimble / lugs of suitable size and taking down old unserviceable complete all as specified and directed.
17S&F of MCCB 200 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 160-200 Amp, Ics= 100% Icu including providing new thimble / lugs of suitable size and taking down old unserviceable complete all as specified and directed.
18S&F of MCCB 160 Amps AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 125-160 Amp, Ics= 100% Icu including providing new thimble / lugs of suitable size and taking down old unserviceable complete all as specified and directed.
19S&F of MCCB 125 Amps AC 4 pole 415 Volt 16 KA breaking capacity with thermal magnetic release range 100-125 Amp, Ics= 100% Icu including providing new thimble / lugs of suitable size and taking down old unserviceable complete all as specified and directed.
20S&F of MCCB 63-100 Amps AC 4 pole 415 Volt 16 KA breaking capacity with thermal magnetic release range 63-100 Amp, Ics= 100% Icu including providing new thimble / lugs of suitable size and taking down old unserviceable complete all as specified and directed.
21S&F electronic digital timer switch, 50 Hz, suppply voltage range 110- 240 volt of LT panel any capacity as per existing size with suitable size and capacity insulators including taking down complete all as specified and directed.
22S&F Copper bus bas of LT panel any capacity as per existing size with suitable size and capacity insulators including taking down complete all as specified and directed.
23S&F aluminium bus bas of LT panel any capacity as per existing size with suitable size and capacity insulators including taking down complete all as specified and directed.
24M&L for servicing / maintenance of Air circuit breaker by authorised rep including control wiring for auto operation of ACB, control PCB etc, cleaning of all parts, cleaning arc contact, replacement of damaged thimble and replacement of burnt out wiring, relays and all other minor accessories to make it serviceable complete testing of equipment for auto/ mannual operation complete all as specified and directed.
25M&L for replacement of burnt out closing / tripping / shunt /UV coil of ACB of Make : ABB or equivalent by authroised rep including interlock wiring with suitable copper wire complete all as specified and directed.
26M&L for replacement Arcing contact assembly (set of 01 No fexed & 01 No moving) suitable for ACB 630A to 1000 Amp complete all as specified and directed.
27M&L for replacement Main isolating contacts (Jaw contacts) suitable for ACB 630A to 1000 Amp complete all as specified and directed.
28M&L for replacement Main Fixed contacts contacts (Upper terminals) suitable for ACB 630A to 1000 Amp complete all as specified and directed.
29M&L for replacement Arc chutes suitable for ACB 630A to 1000 Amp complete all as specified and directed.
30M&L for replacement mannual charging handle for ACB 630A to 1000 Amp complete all as specified and directed.
31M&L for replacement charging motors 220 V AC suitable for ACB 630 Amp to 1000 Amp complete all as specified and directed.
32M&L for prepration of old painted steel surface of panel board ,E/M plant and equipments any gaugeg/size and applying two coats of synthetic enamel paint ( first grade quality) (using spray painting machine) etc, complete all as specified and directed.
33M&L for servicing / maintenance of synchronising panel of 1000 Amp capacity by authorised rep including control wiring for auto operation of synchronising panel control PCB for DG etc, cleaning of all parts, cleaning arc contact, replacement of damaged thimble and replacement of burnt out wiring, relays and all other minor accessories to make it serviceable complete testing of equipment for auto/ mannual operation complete all as specified and directed.
34M&L for taking down all 11 KV HT connection from the existing VCB, Bus coupler panel, RMU any type and dismantling all diffective or burnt out parts, part by carefully for repair/replacement complete all as specified and directed. Please Enable Macros to View BoQ information
35M&L for taking down all 11 KV HT connection from the existing VCB, Bus coupler panel, RMU any type and dismantling all diffective or burnt out parts, part by carefully for repair/replacement complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56612798
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 60 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Unsv/ Damaged Lt Switchgear At Tech Area And Replacement Of Outdoor Lt Panels In Omq, Smq Area And Repair/ Maintenance Of Vcb, Rmu And Allied Works At Tech Area, Mrs, Smq Area And Omq Area At Af Stn Hasimara Under Ge (Af) Hasimara.
Basic Detail
Tender No 8688/HAS/2026-27/E8
Bidding Type Tender
Location
City Jalpaiguri
State West Bengal
Key Dates
Publish Date 23 Jul 2026
Submission Date 19 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 60 Lakhs
Tender Fee 1000
EMD 1.15 Lakhs
Exemption Available
Document List
5ea0c268-8120-4ad0-a0d4-c20bf6a52a0b.html
8688TenDocuments.pdf
BOQ_873986.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 26 days
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 33 days

Tender Documents

Download All (ZIP) ↓
html

5ea0c268-8120-4ad0-a0d4-c20bf6a52a0b.html

pdf

8688TenDocuments.pdf

xls

BOQ_873986.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders