Tender For Provision Of Security Light & Pathway Light At Gh Area, Provision Of Gi Pipe Of Gurkha C To Pb Married Accommodation, Provn Of Street Ligfht From Mt Section Of Ge Dssc To Mes Civil Married Accomodation, Provn Of Grills For Oht Of Chola Hou
Tender Overview
Project Description
Tender for Provision Of Security Light & Pathway Light At Gh Area, Provision Of Gi Pipe Of Gurkha C To Pb Married Accommodation, Provn Of Street Ligfht From Mt Section Of Ge Dssc To Mes Civil Married Accomodation, Provn Of Grills For Oht Of Chola House, Cedars, Wood Side, Iscoyd And Forest View And Provision Of Non Ese Type Lightning Protection System At Watermanship Training Centre (Wtc) At Dssc Wellington
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Jul-2026 | 8655 Revised BOQ | BOQ | 13-Aug-2026 |
| 2 | 13-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-Aug-2026 |
| 3 | 20-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | PROVISION OF SECURITY LIGHT & PATHWAY LIGHT AT GH BLOCK NO 16 TO 21, BLOCK NO 32 TO 41, BLOCK NO 11 TO 25 & BLOCK NO 14 TO 23 AT GH AREA AT DSSC WELLINGTON |
| 2 | Supply , installation, testing and comminissioning of 6 metre height Hot Dip Galvanized Octagonal Street Light Pole with 1 Mtr long single Arm GI bracket in approved design capable of holding luminaire. The pole shall have A/F of 130mm at bottom and 70mm at top. The Pole thickness of not less than 3mm. The pole shall be provided with GI base plate of size not less than 200mm X 200mm X 12mm, 600mm long 'J' type GI Foundation bolts of min. 20mm dia each with 3 nos of GI nuts and GI Washers etc and outlines requirements for the manufacturer including ISO 9001, BSEN 10025 / BSEN certifications etc complete all as specified and directed Make :- Bajaj / Crompton / philips / Wipro / Orient |
| 3 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete all as specified and directed Make: Bajaj - ZELA P 72L WH PO TG SD J / Wipro: LR09-781-XXX-57-XX / Philips-BRP501 LED078 CW R5C PSU S1 V1 / Orient- LSFS-060-C |
| 4 | S&F loop in- loop out fuse junction box of internal dimension 240x130x95 mm made out of FRP sheet with weather proof conopy and locking screw fitted with and incl 6 Amps MCB - 1 No, 50 Amps rated 4 Way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on steel Octagonal pole including necessary clamps, nut and bolt , glands, lugs complete all as specified and directed . |
| 5 | Supply and fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 core x 10 sq. mm complete all as specified and directed |
| 6 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for errection of poles, laying of cables etc and getting out in hard/dense soil complete all as specified and directed . |
| 7 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm in depth (soil) all as specified and directed . |
| 8 | Removing excavated material (soil) to a distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed. |
| 9 | M&L for providing sand cushioning for protection of UG cable in trenches with coarse Riddled soil Earth of including filling, spreading and punning down to desired thickness complete and all as specified and directed. |
| 10 | Supply and laying well burnt old size sub class 'B' bricks of size 230mm x 115mm x 75mm bricks in trenches for cable protection of U/G cables above sand cushioning complete all as specified and directed. |
| 11 | S&F in replacement of PVC insulated flexible multicore round copper conductor cable of size 3 core 1.5 Sqmm including necessary end connector fixed in PVC Conduit along with pole structure etc with all fixing & connecting accessories including taking down the old Unsv wire from pole complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 12 | S&F in replacement of PVC insulated flexible multicore round copper conductor cable of size 3 core 1.5 Sqmm including necessary end connector fixed in PVC Conduit along with pole structure etc with all fixing & connecting accessories including taking down the old Unsv wire from pole complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender