Tender For Special Repair/ Replacement Of Old Vintage Lt Underground Cable And Connected Works At Aftc
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Aug 2026
18 days left
EMD
97350
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bangalore → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair/ Replacement Of Old Vintage Lt Underground Cable And Connected Works At Aftc
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out in soft/loose soil for laying of cables, pipes and foundations etc, complete all as specified and directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. |
| 3 | Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. |
| 4 | Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. |
| 5 | Material and labour for well burnt bricks ‘B’ class as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. |
| 6 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces. |
| 7 | Supply & fixing GI tubing light grade 100 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed. |
| 8 | Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 150 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 9 | Material and labour for replacement of 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 10 | Material and labour for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 120 Sqmm to 185 Sqmm, complete all as specified and directed. |
| 11 | Supply, installation, testing and commissioning stater panel CPRI Tested suitable for 3 phase 415 Volts of suitable size made out of 3.00 mm thick CRCA sheet for outdoor panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 1000 Amp and including PCC foundation as per site/ manufacturer requairment to accomodate to the following :-INCOMING(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 630 Amps,50 KA - 02 Nos (Incomer).(b) Change over switch 4 Pole, 415 V of capacity 630 Amps - 01 No(c) LED indicating lamp R-Y-B - 06 Nos.(d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No OUTGOING(a) MCCB with thermal magnetic release 4 Pole, 415V of capacity 250 Amps,25 KA - 02 Nos.(b) MCCB with thermal magnetic release 4 Pole, 415V of capacity 160 Amps,25 KA - 02 Nos.(c) MCCB with thermal magnetic release 4 Pole, 415V of capacity 100 Amps,16 KA - 01 No. |
| 12 | Taking down carefully copper/aluminum point wiring (light, fan, Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc and making good disturbed surface of wall, floors , roof etc all as specified and directed. |
| 13 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non metalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame, concealed in wall and 1.5 sq mm multi stranded copper conductor FRLS cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 14 | All as per item No. 13 here in before but for one light point controlled by one way switch. |
| 15 | All as per item No. 13 but for One ceiling fan /exhaust point controlled by one switch one way 5/6 Amps and fan speed regulator |
| 16 | All as per item No. 13 here in before but for one bell point controlled by one bell push. |
| 17 | All as per item No. 13 here -in - before but for One 2/3 pin switch socket point controlled by 5/ 6 Amps switch on Independent board. |
| 18 | All as per item No. 13 but for One socket outlet point 5/6 Amps 3 pin on same board. |
| 19 | All as per item No. 13 here -in - before but for One light point controlled by two, two way switches. |
| 20 | All as per item No. 13 here -in - before but for One 3 pin switch socket outlet combination, 15 Amps, with cables 4 sq mm all as specified and directed. |
| 21 | Supply and Fix modular switch 1 way 5/6 Amp,1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 22 | Supply and Fix modular switch 1 way 15/16 Amp,1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 23 | Supply and Fix modular Socket,5/6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 24 | Supply and Fix modular Socket, 5/15 and 6/16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/ Indoasian |
| 25 | Supply and Fix modular switch 2 way 5/6 Amp, 1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian |
| 26 | Supply and Fix modular bell push 5/6 Amp,1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 27 | S&F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed. |
| 28 | Supply & fix of ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed. |
| 29 | S & F of modular PVC White cover plate with frame, 2 module |
| 30 | S & F of modular PVC White cover plate with frame, 3 module |
| 31 | Supply and fix PVC White cover plate with frame,4 module |
| 32 | Supply and fix PVC White cover plate with frame,6 module |
| 33 | Supply and fix PVC White cover plate with frame,8 module |
| 34 | Supply and fix PVC White cover plate with frame,12 module |
| 35 | M& L in repair PVC Casing & Capping medium 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed. |
| 36 | M& L in repair PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed. |
| 37 | M&L for Cutting chases, pinning in brick wall making good to facings where required in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 38 | M&L for Cutting chases, pinning in. making good to facings where required in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed. |
| 39 | S&F in repair of Sub main wiring with 2 runs of single core, 4 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 4.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire alongwith PVC casing capping/ conduit shall be measured as one run length) Make : Havells, Polycab, Plaza |
| 40 | S&F factory made powder coated distribution board VTPN, 4 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB with fitting fixture complete all as specified and directed.Make : Indoasian/ Havells/ Legrand. |
| 41 | S&F distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 42 | S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 4\\"x 4\\" all as specified and directed. |
| 43 | S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6\\"x 4\\" all as specified and directed. Please Enable Macros to View BoQ information |
| 44 | S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6\\"x 4\\" all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender