Tender For 8705 - Maintenance / Repairs Of Ceiling Fans, Wall Mounted Fans, Geysers At Nstl, Visakhapatnam
Tender Value
20 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
16 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for 8705 - Maintenance / Repairs Of Ceiling Fans, Wall Mounted Fans, Geysers At Nstl, Visakhapatnam
BOQ
| Sl. No. | Item Description |
| 1 | M&L for taking down & Overhauling of ceiling fan/Exhaust fan/wall mounted fan/Air circultirs/Pedestal fan of any size and make, dismantling parts, properly cleaning/removing old existing grease oil and removing old paint from blades and body including down rods complete. Applying new oil grease, varnishing of winding, cleaning dust, rust and applying one coat white enamel paint over a coat of steel primer, assembling and refixing at site complete all as specified. |
| 2 | M&L for repairing of ceiling fan of any make, 1200 mm/1400 mm sweep dismantling its parts cleaning properly, rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petty items such as split pins,gun mteal bush,ball bearing assembling and testing after fixing of fan blades, refixing at site and connecting complete all as specified and directed. |
| 3 | M &L for repairing of Exhaust fans/Wall mounted fans/Air circulators/Pedestal fan of any make and any sweep dismantling its parts cleaning properly, rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petti items such as split pins,gun mteal bush,ball bearing assembling and testing after fixing of fan blades, refixing at site with required flywood and connecting complete all as specified and directed. |
| 4 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by Engr-in-charge.Make :Anchor/Indo asian/Cona/Leader/HPL/Gold medal/Havells |
| 5 | S&F in replacement Stepped modular type electronic fan regulator 120 W 2 module suitable with existing sheet for 1200 /1400 mm sweep fans complete. Make :Anchor/Indo asian/Cona/Leader/HPL/Gold medal/Havells |
| 6 | M&L in replacement, for capacitor, 230 volts, AC + 5% complete all as spcified for for the following :- |
| 7 | (a) 2.5 mfd |
| 8 | (b) 3.15 mfd |
| 9 | (c) 4 mfd |
| 10 | M&L, in replacement, of PVC / metalic clamp for holding capacitor of any type/ size all as directed. |
| 11 | M&L for replacement of MS fan down rod 2 feet for holding ceiling fan complete all as specified and directed by Engr-in-charge. |
| 12 | M&L for replacement of MS fan down rod 3 feet for holding ceiling fan complete all as specified and directed by Engr-in-charge. |
| 13 | Supply and fix wooden frame of thicknes 6 mm of suitable size for fixing of exhaust fan in existing hole including all nut/bolts complete all as specified and directed by Engineer-in-Charge. |
| 14 | M& L for Opening the geyser 25/50 ltr capacity and taking out inner tank and glass wool from inside the geyser for descaling and washing with acid to remove the scale, dirt etc if any and re-fixing the same after re-assemble into the geyser and proper filling of glass wool around inner tank complete all as specified and directed.Note :-Glass wool will be paid separately under respective item of Sch 'A' as 'supply only'. |
| 15 | Supply and fixing of pack glass wool for geyser capacity 25/50 Ltrs complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply and fix in replacement outer tank made out of MS sheet suitable for geyser of capacity 25 ltr as per sample duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 17 | Supply and fix in replacement inner tank made out of steel sheet suitable for geyser of capacity 25 ltr complete including necessary driling, brazing work, nut, bolt & washers and testing complete all as specified and directed. |
| 18 | Supply and fix in replacement plug top 3 pin 15 Amp 240 voits ISI marked complete all as specified and directed by EIC. |
| 19 | Supply and fix only gate valve of size 15mm dia including removal of old one by cleaning the pipe line all as specified and directed by EIC. |
| 20 | Supply and fix non return valve (gun metal) of size 15mm including removal of old ones complete all as specified and directed by EIC. |
| 21 | Supply and fix in replacement fusible plug suitable for 25 Ltrs Cap storage type water heater including provn of necessary GI fittings removal of existing valves complete all as specified and directed by EIC. |
| 22 | Supply and fix in replacement indicator lamp assembly complete for water heater (geyser) suitable to work on AC 230 volts supply and to match the existing size any type including disconnecting and removal of old ones. |
| 23 | Supply and fix only MS Nut bolts with split pin as per sample and as directed by Engineer-in-Charge. |
| 24 | Supply in replacement heating element 1.5/2 KW of storage type water heater of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-Charge of capacity ISI Marked : |
| 25 | Supply & fix in replacement thermostat suitable for 25/50 ltrs capacity storage type water heater including removal of old unserviceable ones as directed by Engineer-in-Charge. |
| 26 | Supply and fix in replacement outer cover plate lower suitable for 25 ltrs capacity geyser complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fix in replacement geyser apperture plate/flange assambely (as per approved sample) of ISI marked suitable for 25 ltrs capacity geyser complete all as specified and directed by EIC. |
| 28 | Supply and fix in replacement pressure release valve suitable for 25 ltrs geyser complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and fix in replacement drain plug brass with washer suitable for 25 ltrs geysers complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F in repair PVC insulated copper conductor 3 core flexible cable of size 4 sq mmcomplete all as specified and directed. |
| 31 | Supply and fix in replacement gyser hot water heavy duty connection branded flexible pipe made out of brass female coupling for connecting gyser outlet to existing tab of 12/15 mm dia, 600 mm long complete all as specified and directed by EIC. |
| 32 | Supply and fix in replacement gyser hot water heavy duty connection branded flexible pipe made out of brass female coupling for connecting gyser outlet to existing tab of 12/15 mm dia , 450 mm long complete all as specified and directed by EIC. |
| 33 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc complete as required including taking down the existing ceiling fan and deposite in the MES store yard. |
| 34 | Supply and fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed including taking down the existing ceiling fan and deposite in the MES store yard. |
| 35 | Supply and fixing of Exhaust fan of PVC body AC single phase 230 Volts of size 300 mm sweep complete with blade, frame and louvers, Voltage 230 Volts, 50 Hz, RPM 1200, Copper winding, min Air delivery 860 CMH connecting up including provision of three core flexible copper wire of suitable size from ceiling rose to exhaust fan complete all as specified and directed including taking down the existing exhuast fan and deposite in the MES store yard. |
| 36 | Supply and fixing of Exhaust fan of metal body heavy duty AC single phase 230 Volts of size 300 mm sweep complete with blade, frame and louvers, Voltage 230 Volts, 50 Hz, RPM 900, Copper winding, min Air delivery 1145 CMH connecting up including provision of three core flexible copper wire of suitable size from ceiling rose to exhaust fan complete all as specified and directed including taking down the existing exhuast fan and deposite in the MES store yard. |
| 37 | Supply and fixing of Wall mounted fan of 400 mm sweep, Voltage 230 Volts, 50 Hz, RPM 1350, Copper winding, min Air delivery 65 CMH including 3 core 1.5 sqmm copper conductor cable multi-stranded as required at site and connecting to ceiling rose complete all as specified and direceted including taking down the existing fan and deposite in the MES store yard. |
| 38 | Supply and fixing of Heavy duty Air circulating pedestal fan of size 450 mm sweep, 230 volts, RPM 1440 including all necessary fixing arrangements all as specified and as directed including taking down the existing fan and deposite in the MES store yard. |
| 39 | Supply and fixing of water heater storage induction type (Geyser) vertical type with suitable size of fastner and including provision and connecting up of SS braided pipe suitable size with adopter for inlet and outlet water connection having adjustable knob for temperature control and copper inner tank should be glass line coated complete all as specified of capacity 25 ltrs having element up to 2 KW BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection pipe including taking down existing water heaters complete all as specified and directed ncluding taking down the existing geyser and deposite in the MES store yard. |
| 40 | M & L in replacement of Earthing complete with galvanised steel earth electrode 60Cm x 60Cm x 6 mm thick directly burried in ground (earth pit not less than 2.25 M deep below the normal ground level conneceted to galvanised earth lead dia 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron steel including necessery excavation earth work PCC chamber CI chamber cover protection pipe watering pipe etc. (Complete all as shown in electrical plate No 3 and conected to earthing test point complete including excavation earthwork, PCC chamber, chamber cover ,funnel watering and protection pipe etc all specified and directed and testing on completion. Note:- If the desired earth resistance is not less than 5 Ohms, earthing shall be redone by the contractor at no extra cost to the department. |
| 41 | All as per item No. 37 here in above but GI earth strip 32x6 mm |
| 42 | M&L Earthing continuity galvanised earth lead dia 4 mm dia or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge. |
| 43 | All as per item No. 39 here in above but GI earth strip 32x6 mm |
| 44 | Taking down carefully point wiring ( fan/power point) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, removing materials from site and making good the disturbed surfaces of walls, floors etc as per existing specification and taken as credit complete all as specified and as directed by the Engineer-in-Charge. |
| 45 | Taking down sub main wiring of aluminium/copperconductor PVC insulated cable of any size drawn through rigid steel / PVC conduit GI wire accessories etc complete and removing materials from site and making good the disturbed surfaces of walls, floors etc as per existing specification and taken as credit complete all as specified and as directed by the Engineer-in-Charge. |
| 46 | Material and labour for point wiring with 1.5 sqmm (nominal cross section area) single core PVC insulated unsheathed cable of 1100 Volts grade (FRLSH) multistrand with copper conductor drawn through and including non metallic, rigid PVC conduit of adequate size with all fittings and conduit accessories concealed in wall/ceiling/floor/roof etc. including 1.6 mm thick sunk mild steel terminal box with 3mm thick plastic laminated sheet top cover, cadmium plated iron screws for housing the switches, socket outlets including provision of 1.5 sqmm green in colour PVC insulated copper conductor single core multistrand (FRLSH) for earth continuity conductor and connected to common earth dolly all as specified for the One ceiling Fan/ Exhaust fan/Wall mounted fan/pedestal fan controlled by one switch |
| 47 | Description all as per item no 41 above but for AC/Geyser Point 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 Amps point and one single core 2.5 sq mm PVC insulated unsheathed copper cable as earth continuity conductor (colour green) fixed to dolly. |
| 48 | Supply and fix in repair of Switch piano type 5 Amp single pole one way complete all as specified and directed. |
| 49 | Supply and fix switch socket combination multipurpose along with gang box 3 pin 15 Amp and 3 pin 5 amp flush type 2 in 1 complete all as specified and directed. |
| 50 | Supply and fix switch socket combination along with gang box 5 amp flush type complete all as specified and directed.Make :Anchor/Indo asian/Cona/Leader/HPL/Gold medal/Havells |
| 51 | Supply and fixing one module switch modular type, single pole one way 6/10 Amps 230 Volts ISI Marked including cover plate & metal flush box all as specified and as directed by the Engineer-in-Charge.Make:Make :Anchor/Indo asian/Cona/Leader/HPL/Gold medal/Havells |
| 52 | Supply and fixing one module switch modular type, single pole one way 16 Amps 230 Volts ISI Marked including cover plate & metal flush box all as specified and as directed by the Engineer-in-Charge.Make:Make :Anchor/Indo asian/Cona/Leader/HPL/Gold medal/Havells |
| 53 | Supply and fixing socket two module type 6 Amps , 3 pin , 230 Volts ISI Marked including cover plate & metal flush box all as specified and as directed by the Engineer-in-Charge.Make :Anchor/Indo asian/Cona/Leader/HPL/Gold medal/Havells |
| 54 | Supply and fixing socket two module type 6/16 Amps, twin socket , 3 pin , 230 Volts ISI Marked including cover plate & metal flush box all as specified and as directed by the Engineer-in-Charge.Make :Anchor/Indo asian/Cona/Leader/HPL/Gold medal/Havells |
| 55 | Supply and fix ceiling rose surface backelite min dia 35 mm three terminal complete all as specified and directed. |
| 56 | S & F Sub main wiring with PVC insulated cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor on and incl non metalic rigid PVC conduitsurface in wall / roof/ceiling (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4 sq mm for earth continuity all as directed. |
| 57 | S & F in replacement sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB with 20 Amps after taking down existing. |
| 58 | S&F in replacement MCCB, 4 pole, 415 volt AC, 63 amps, fixed type with breaking capacity 16KA all as specified. |
| 59 | S&F in replacement MCCB, 4 pole, 415 volt AC, 100 amps, fixed type with breaking capacity 16KA all as specified. |
| 60 | Supply and fix MCB TP 25-63 Amps 4 Pole, with breaking capacity 16 KA C Curvre along with replacement of old unservceable one complete all as specified and directed. |
| 61 | Supply and fix MCB TPN 16-32 Amps 4 Pole, with breaking capacity 16 KA, C Curvre along with replacement of old unservceable one complete all as specified and directed. |
| 62 | Supply and fix MCB TPN 40/100 Amps 4 Pole, with breaking capacity 16 KA , C Curvre along with replacement of old unservceable one complete all as specified and directed. |
| 63 | Supply and fix MCB SPN 240 Volts 40 to 63 Amp breaking capacity 10 KA, C Curvre along with replacement of old unservceable one complete all as specified. |
| 64 | Supply and fix MCB SPN 240 Volts 32 Amp breaking capacity 10 KA ,C Curvre along with replacement of old unservceable one complete all as specified. |
| 65 | Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA ,C curve along with replacement of old unservceable one complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender