Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #56612710

Tender For Cleaning/Repair/Replacement Of Sewage Line And Other Connected B/R Items In Md Accn At Kirby Place, Cherring Enclave, Cod Line, Me Line, Etc Under The Aor Of Age B/R-I Of Ge (North) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
48 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
4 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Cleaning/Repair/Replacement Of Sewage Line And Other Connected B/R Items In Md Accn At Kirby Place, Cherring Enclave, Cod Line, Me Line, Etc Under The Aor Of Age B/R-I Of Ge (North) Delhi Cantt-10

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-Aug-2026

BOQ

Name of Work:- CLEANING/REPAIR/REPLACEMENT OF SEWAGE LINE AND OTHER CONNECTED B/R ITEMS IN MD ACCN AT KIRBY PLACE, CHERRING ENCLAVE, COD LINE, ME LINE, ETC UNDER THE AOR OF AGE B/R-I OF GE (NORTH) DELHI CANTT-10
Sl. No. Item Description
1Excavation in trenches, in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
2All as per the description of srl item No 1 above but exc 1.50m but not exc 3.00 mtr in depth.
3All as per the description of srl item No 01 above but exceeding 3 m or part thereof in depth upto 4.5 m but for hard/dense soil.
4M&L for concrete bed to drain pipe/sewage pipe of any dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete PCC 1:4 : 8 type D-2 (Using 40mm graded stone agg) including demolition complete all as specified.
5M&L for 100mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
6M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortarv incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
7M&L for 200mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
8M&L for 300mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge
9Cutting into existing manholes for connecting new drains, of 100 mm to 300 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
10Demolition of Concrete of any description and in any position not otherwise specifically provided for.
11M&L for PCC 1:4:8, Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete.
12Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) incl Dismantling of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified.
13Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) complete all as specified. (For raising of Existing Man hole Height, etc )
14M&L cement concrete type B1 (1:2:4) using 20mm graded aggregate as in coping, benching, kerbs or mud stops, rounded or chamfered on edges complete complete all as specified and directed.
15M&L rendering 15 mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth without using extra cement in CM 1:4 finished even and smooth including Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and as directed by engr-in-charge.
16M&L rendering 15 mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth without using extra cement in CM 1:4 finished even and smooth complete all as specified and as directed by engr-in-charge.
17M&L for Preparing new plastered or old plater/concrete surfaces in any position and applying two coats of white washcomplete all as specified.
18Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
19Removing excavated material up to a distance not exceeding 1.5KM and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
20S&F in repair SFRC GT covers with and including frame medium duty of any size 50mm thick factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked incl fixing complete to match the road/ floor surface,all as specified by Engr-in-Charge
21S&F in repair 80mm thick Manhole/ drain covers of any size with and including frame medium duty factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked incl fixing complete to match the road/ floor surface all as specified by Engr-in-Charge
22M&L for Precast RCC type B-1 (1:2:4), using 20 mm graded stone aggregates cover slabs for manholes, septic tank, soakage well, open drains etc. including all mouldings but excluding frame, set in cement mortar (1:4) including demolition of old RCC manhole/drain cover (reinforcement cut as required to facilitate ) complete all as specified.
23Mild steel TMT bars 10mm dia and over (and flat iron where quered),cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips or welded to flat iron complete all as specified.
24M&L for Framed work as in opening of manhole and manhole cover of angle iron or other section , also fastening and fixing and welding with MS bars conforming to Fe-410 W Gide E-290, incl painting with two coat of synthetic enamil paint over a coat of red oxide, complete all as specified and as directed.
25S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls ( any height)/under floor(any depth) etc with MS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of any dia and in any position complete all as specified.
26S&F PVC (SWR) bends suitable for 75 mm external dia with or without access door complete all as specified
27S&F PVC (SWR) junction single, (single /double T&Y) equal or unequal with or without access door confirming to IS: 14735, suitable for PVC soil waste discharge pipe of 75 mm dia Complete all as specified and as directed.
28S&F PVC(SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to fixed to walls ( any height)/under floor(any depth) etc with MS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of any dia and in any position complete all as specified.
29S&F PVC (SWR) bends suitable for 110 mm external dia with or without access door complete all as specified
30S&F PVC (SWR) junction single, (single/double T&Y) equal or unequal with or without access door confirming to IS: 14735, suitable for PVC soil waste discharge pipe of 110 mm dia Complete all as specified and as directed.
31M&L non skid ceramic tiles colored tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,in floor etc set and jointed in neat cement slurry and pointed in colour cement laid over and including 15mm thick cement mortar screed bed in CM (1:6) including dismantling floor, tiling including cement mortar bedding complete all as specified and directed.
32M&L machine pressed precast rubber mould coloured concrete interlocking paver blocks of 60 mm thick any shape and size conforming to IS 15658-2006 ,M-35 grade with grey cement and no pigment over 40mm thick Sand filling over 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub floor, Sub base, floor inclding demolition of existing PCC/ any type of surface complete all as specified & as directed.
33M&L Chequered cement concrete tiles 300mm X 300mm X 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement and pigment over screed bed or bedding layers of mortars 15 mm thick in CM 1:6 over 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub floor, Sub base, floor inclding demolition of existing PCC/ any type of surface complete all as specified & as directed. all as specified and as directed.
34Construction of Soakage wells of size 1.80 Mtr dia x3.00m depth excavation in any types of soil, foundation in PCC 1:3:6 walls of honeycomb masonry with brick work all as shown in Cdrg No CEDZ- 1124 (R) sheet No 1/1 dated 12.02.2003 & revised upto 14.05.2004, top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slabs in M-25/SFRC covers, interconnecting pipes of RCC/DWC complete filled with brick bats including demolition of existing old soakage well of any size and refill the same up to the existing ground level complete all as as specified and directed complete all as directed.
35M&L for cleaning of blocked sewage line, any type of dia in horizontal or vertical position from manhole to manhole drain pipes. Note:- Cleaning of sewage line of any type and dia or bore upto any depth by removing all filts/silts, foreign material and other deposits whatever completely and making the line free from all obstacles and tyesting the flow of sewer line evently, smoothly by filling water. The cleaning operation will be carried out in suitable length by blocking the first and last manhole of sewer line and removing the silt/sludge & deposits out side of defence land in covered van/Trolly all as specified and directed by Engr-in-Charge.rate.
36M&L cleaning of chocked sewer line by diesel/petrol runing vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 ltrs water jetting tank including skilled operator, supervisig engineer, labour etc for cleaning and partial desilting of manholes and dechocking of sewer lines of any dia & size and in any description, dechocking and flushing of sewer line from one manholes to another by high pressure jetting system of 2200 PSI for sewer line of following mentioned dia for all depth complete all as specified and directed.Note:- Rates quoted cleaned for 08 hrs of above mentioned machine. Any work carried out throughout 08 hrs shall be measured as one Job.
37M&L cleaning of chocked sewer line by diesel/petrol runing vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 8000 litres suction capacity and 10000 ltrs water jetting tank including skilled operator, supervisig engineer, labour etc for cleaning and partial desilting of manholes and dechocking of sewer lines of any dia & size and in any description, dechocking and flushing of sewer line from one manholes to another by high pressure jetting system of 2200 PSI for sewer line of following mentioned dia for all depth complete all as specified and directed.Note:- Rates quoted cleaned for 08 hrs of above mentioned machine. Any work carried out throughout 08 hrs shall be measured as on Job.
38Cleaning of sludge from septic tank, soakage well and manhole etc of any capacity and depth by dewatering, taking out mud/ sludge/quid, getting out and removing & depositing the sludge , complete all as specified and directed Note:- septic tank and soakage well be cleaned by Mechanical Vehicle ( Tanker) and Dewatering/Sludge to be thrown away outside of defence area.
39M&L for Matt finish Exteior wall tiles 8 to 10mm thick & not exc 0.18 sqm , colour & shade of tiles as approved by Engr-in-charge,set and jointed in neat cement slurry and pointed in coloured cement to match the surface incl rendering 10 mm thick in CM (1:4) and finished rough incl Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisesetc complete all as specified and directed by Engr-in-Charge.
40M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings incl taking down/rempvong old plater suface or pointing of any type and complete all as specified.Note:- Payment for providing grooves shall be measured and paid separately. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56612710
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Cleaning/Repair/Replacement Of Sewage Line And Other Connected B/R Items In Md Accn At Kirby Place, Cherring Enclave, Cod Line, Me Line, Etc Under The Aor Of Age B/R-I Of Ge (North) Delhi Cantt-10
Basic Detail
Tender No GE/NORTH-104/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 12 Aug 2026
Submission Date 19 Aug 2026
Open Date 21 Aug 2026
Finance
Tender Value 48 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
8820f63c-8d76-47d7-bcf4-775b6521dca7.html
BOQ_873747.xls
Gen104.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

8820f63c-8d76-47d7-bcf4-775b6521dca7.html

xls

BOQ_873747.xls

pdf

Gen104.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender