Tender For Repair Of Geysers,Solar Water Heaters Etc In Md/ Otm Accn At Chandimandir Mil Stn
Tender Value
35 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
19 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Of Geysers,Solar Water Heaters Etc In Md/ Otm Accn At Chandimandir Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Taking down geysers of any type and any capacity due to rusting of bolts/seepage of wall and re-installation at any location including S&F in repair of heavy duty pin type fastener 4 inch Job long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and as directed |
| 2 | Inspection,checking adjustments and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :-(a) Inspection, taking out of drain plug & dewatering and refixing the same complete all as directed .(b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.(e) Checking and correct earth continuity of electrical items.(f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C.(g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) The cost of spare parts required for repair & mainenance of geysers covered under this item shall be measured and paid separately under the relevant item. (j) Make of geysers covered under the scope of work :- Sidhson, bajaj, recold, crompton, orison, ditz premier, peeco, empire, shakti, sahas, konark Note : Irrespective of the Number of complaints, work against this item of BOQ shall be completed with in 24 hours after handing over the Complaint slip failing which recovery @ Rs 200/-/per geyser per day delay shall be effected from the contractors payment. |
| 3 | Supply only heating element, Round type / tikona type / banana type, 1.5 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold/Theta. |
| 4 | Supply only heating element, Round type / tikona type / banana type, 2 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold/Theta. |
| 5 | Supply only thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : USHA / Bajaj /Theta / Elcon. |
| 6 | Supply and fixing glass wool for geysers complete all as specified and as directed. |
| 7 | Supply only base assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed. |
| 8 | Supply only indicator lamp for geyser of any type colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton |
| 9 | Supply only stainless-steel inner tank of minimum 22 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25/35 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and as directed. |
| 10 | Supply only of stainless-steel inner tank of minimum 22 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified and as directed. |
| 11 | Supply only outer body of MS sheet not less than 22 gauge suitable for 25/35 ltr geyser with white synthetic enameled paints complete all as specified and as directed. |
| 12 | Supply only outer body of MS sheet not less than 22 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and as directed. |
| 13 | Supply only plug top 3 pin 15 Amp ISI marked complete all as specified and as directed. Make : SSK / CONA / FINE. |
| 14 | Supply only bottom cover of PVC suitable for 25/35 ltrs capacity geysers complete all as specified and as directed. |
| 15 | Supply only bottom cover of PVC suitable for 50 ltrs capacity geysers complete all as specified and as directed. |
| 16 | Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, chromium plated fancy type, screwed both ends for 15mm bore iron pipe or for union, ISI marked, fixed as in repair complete all as specified and as directed. |
| 17 | Bib taps brass, fancy type, with wall flange, chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed in repair complete all as specified and directed. |
| 18 | Brass Mixer tap cast copper alloy chromium plated, fancy type, wall mounted, suitable for mixing hot and cold water screwed for 15mm bore iron pipe, ISI marked, fixed as in repair complete all as specified and as directed. |
| 19 | PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe, fixed as in repair complete all as specified and as directed. |
| 20 | PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe fixed as in repair complete all as specified and as directed. |
| 21 | 3 core PVC insulated copper cable of size 40/0.0076 multi stranded fixed as in repair complete all as specified and as directed. |
| 22 | Switch piano flush type, single pole, one way, 16/20 Amp fixed as in repair complete all as specified and as directed. |
| 23 | Shuttered socket out let, 3 Pin, 16 Amp, 230 volts piano flush type fixed as in repair complete all as specified and as directed. |
| 24 | Supply and laying in floor, fixed to walls and ceiling, 25mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed. |
| 25 | All as per srl item No. 24 above but 20mm bore. |
| 26 | All as per srl item No. 24 above but 15mm bore. |
| 27 | Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc complete all as specified and directed. |
| 28 | Painting of outer surface of 25/35/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed. |
| 29 | Sheet metal enclosure single pole and neutral with 3 pin metal plug and socket complete with one single pole MCB 20 Amps, 230 volts, fixed as in repair complete all as specified and directed. |
| 30 | Instant hot water instrument 1 to 3 Itr capacity, as per sample fixed as in repair complete all as specified and as directed. |
| 31 | Dismantling carefully solar storage water heating system of any capacity, any type for following works with testing and refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :-(a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank.(b) Checking water tightness of storage tank after cleaning.(c) Checking and correcting earth continuity of electrical items.(d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately. |
| 32 | Heating element, 3.00 KW 230 volts, ISI marked suitable for solar geyers tank of any make fixed as in repair complete all as specified and as directed. Make : USHA / Bajaj / Recold/Theta. |
| 33 | Supply only thermostat switch for solar water heater (ISI marked) any make and size fixed as in repair complete all as specified and as directed. Make : USHA / Bajaj /Theta / Elcon. |
| 34 | Repair and welded to stainless steel water storage tank of solar storage water heating systme of any capacity 100 to 500 LPD, to prevent any type of leakage at site with testig and refixing the same in original position makig all water / electric connection to entire satisfication of Engineer-in Charge after repair as under(a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank.(b) Checking water tightness of storage tank after cleaning.(c) Checking and correcting earth continuity of electrical items.(d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately. |
| 35 | Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/ concealed conduit and connected to main board and making good disturbed surface including taking down existing unserviceable wiring complete all as specified and as directed. Note: (i) Two run each of one RM of 4.00 sqmm cable and 1 run of one RM of 4.00 sqmm cable together shall be considered as 1 running meter for payment purpose. |
| 36 | Glass collector suitable for solar water heating system of any size fixed as in repair complete all as specified and as directed. |
| 37 | Sheet metal enclosure for DBs flush mounted, 240 Volts, IP-43, suitable for mounting MCB 1 way SPN complete all as specified and directed. |
| 38 | MCB ,SP , 240 volt, 20Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 39 | MCB ,SPN, 240 volt, 16Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 40 | Metal socket 15 Amp suitable for plug top 2 pin 15 Amp ISI marked complete all as specified and directed. |
| 41 | Metal Plug top 2 pin 15 Amp ISI marked complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender