Housing Urban and Rular Development Government Departments Closing in 11 days TDR #56612225

Tender For Electric Utility Shifting For The Work Improvement Of Kashinagar K Sitapur Road Such As Construction Of Reinforced Cement Concrete Drain And Widening With Paver Blocks From 12/900 Km To 13/425 Km In The District Of Gajapati Under State Pla

Issued by Government Departments · Gajapati, Odisha
Tender Value
33.54 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
11 days left
EMD
33600
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gajapati → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electric Utility Shifting For The Work Improvement Of Kashinagar K Sitapur Road Such As Construction Of Reinforced Cement Concrete Drain And Widening With Paver Blocks From 12/900 Km To 13/425 Km In The District Of Gajapati Under State Plan For The Year 2025-26

BOQ

Name of Work:- Electric Utility shifting for the work Improvement of Kashinagar K Sitapur road such as Construction of RCC drain and widening with paver blocks from 12/900 KM to 13/425 KM in the district of Gajapati under state plan for the year 2025-26
Sl. No. Item Description
1PART-I (Erection of 3Ph 3W 11KV Line with 80sqmm covered conductor= 0.280 ckm & 4Nos. guarding)WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
2MS 11 KV 'V' Cross Arm (10.2Kg Each)
3MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
4G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
5100X50X6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (6Nos) including top piece
6Galvanisation of all RS and MS materials
711 KV Disc Insulator (T & C) 45 KN Polymer
8Tension Assembly Wedge Type with Anchoring Clamp for 11 kV 80 Sqmm covered conductor
911 KV Pin Insulator (polymer)
10H.T. Stay set complete
11H.T. Stay Insulator
12H.T. Stay Clamp (1.9Kg/pair)
137/10 SWG G.I. Wire (Grade-2)
14Earthing Support (Coil Type)
15No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
1611KV XLPE COVERED CONDUCTOR 80 SQMM,AAA
17IPC for Covered-Covered Conductor 11 KV 80 Sqmm
18Non metallic ties for 11 kv covered conductor
19Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
20Danger Plate
21Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
22GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
23Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
24GI Bolts, Nuts & Washers of assorted size
2575X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
26No-6 GI Wire for road cross Guarding
27G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
2850x6mm GI Flat for earthing
29Black Paint
30Yellow colour paint for back ground
31Sunderies (Al Binding tape,Insulation tape, etc.)
32PART-II (Erection of 3Ph 6W LT Line with 4x95+1x95+1x16= 0.540 KM)9Mtr long 300Kg PSC Pole
33RCC Base plate
341.1KV LT AB Cable 4X95+1X95+1X16
35CAP CABLE END FOR ABC 95 SQMM
36LT Stay Set (Complete)
37LT Stay Insulator
38LT Stay Clamp
397/12 SWG GI stay wire
40Suspension clamp with Eye hook
41Dead End Clamp suitable for bare messenger XLPE Aerial bunched cable
42EYE hook for XLPE Aerial bunched Cable
43Pole clamp for Eye Hook (For AB Cable)
44Piercing Connector
45Neutral Connector
46Earthing Support (Coil Type)
47No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
48Danger Plate
49Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
50GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
51Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
52G.I. Nuts and Bolts
53Black Paint
54Yellow colour paint for back ground
55Sunderies
56CIVIL PARTStay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2CUM @ 6500=0.2X6500 =Rs.1300
57Concreting of 11Mtr WPB Poles in ratio 1:1.5:3 = 0.450Cum. @ 6648.85 =0.450 x 6648.85 =Rs.2991.98
58Concreting of 9Mtr/8Mtr PSC Poles in ratio 1:1.5:3 = 0.375Cum. @ 6648.85 =0.375 x 6648.85 =Rs.2493.32
59Couping of Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648.85 =Rs.748.00
60Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
61Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
62Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
63PART-II (DISMENTALING)Dismantling of ACSR/AAAC 80/100 mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
64Dismantling of RSJ/WPB pole(116x100mm)
65Dismantling of all accesseries(Disc,pin insulator, v cross arm, danger board, steel structure of cut point from Single pole structure at 9/10/11/13 Mtr and transportation and stacking the materials at a proper place in safe position within 10km /site store and as per instruction of EIC.%_1
66Dismantling of PSC pole (9mtr)& return
67Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
68(Dig 2)PART-I (Erection of 3Ph 3W 11KV Line with 80sqmm cover conductor= 0.210 ckm)WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
69MS 11 KV 'V' Cross Arm (10.2Kg Each)
70MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
71G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
72100x50x6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (4Nos) including top piece
73Galvanisation of all RS and MS materials
7411 KV Disc Insulator (T & C) 45 KN Polymer
75Tension Assembly Wedge Type with Anchoring Clamp for 11 kV 80 Sqmm covered conductor
7611 KV Pin Insulator (polymer)
77H.T. Stay set complete
78H.T. Stay Insulator
79H.T. Stay Clamp (1.9Kg/pair)
807/10 SWG G.I. Wire (Grade-2)
81Earthing Support (Coil Type)
82No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
8311KV XLPE COVERED CONDUCTOR 80 SQMM,AAA
84IPC for Covered-Covered Conductor 11KV 80 Sqmm
85Non-metallic ties for 11KV covered conductor
86Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
87Danger Plate
88Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
89GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
90Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
91GI Bolts, Nuts & Washers of assorted size
9275X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
93No-6 GI Wire for road cross Guarding
94G.I pipe Earthing 40 mm dia medium gauge (3.25mm thick ness) 3 mtr long
9550x6mm GI Flat for earthing
96Black Paint
97Yellow colour paint for back ground
98Sunderies (Al Binding tape,Insulation tape, etc.)
99PART-II (Erection of 3Ph 6W LT Line with 4x95+1x95+1x16= 0.260 KM)1.1KV LT AB Cable 4x95+1x95+1x16
100CAP CABLE END FOR ABC 95 SQMM
101Suspension clamp with Eye hook
102Dead End Clamp suitable for bare messenger XLPE Aerial bunched cable
103EYE hook for XLPE Aerial bunched Cable
104Pole clamp for Eye Hook (For AB Cable)
105Piercing Connector
106Neutral Connector
107G.I. Nuts and Bolts
108Sunderies
109CIVIL PARTStay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2CUM @ 6500=0.2X6500 =Rs.1300
110Concreting of 11Mtr WPB Poles in ratio 1:1.5:3 = 0.450Cum. @ 6648.85 =0.450 x 6648.85 =Rs.2991.98
111Couping of Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85= 0.1125x6648.85 =Rs.748.00
112Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
113Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
114Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
115PART-II (DISMENTALING)Dismantling of ACSR/AAAC 80/100 mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
116Dismantling of RSJ/WPB pole (116x100mm)
117Dismantling of all accesseries(Disc,pin insulator, v cross arm, danger board, steel structure of cut point from Single pole structure at 9/10/11/13 Mtr and transportation and stacking the materials at a proper place in safe position within 10km /site store and as per instruction of EIC.%_1
118Dismantling of PSC pole (9mtr)& return
119Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
120(Dig 3)PART-I (Erection of 3Ph 3W 11KV Line with 80sqmm cover conductor= 0.07 ckm)WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
121MS 11 KV 'V' Cross Arm (10.2Kg Each)
122MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
123G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
124100X50X6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (2Nos) including top piece
125Galvanisation of all RS and MS materials
12611 KV Disc Insulator (T & C) 45 KN Polymer
127Tension Assembly Wedge Type with Anchoring Clamp for 11 kV 80 Sqmm covered conductor
12811 KV Pin Insulator (polymer)
129H.T. Stay set complete
130H.T. Stay Insulator
131H.T. Stay Clamp (1.9Kg/pair)
1327/10 SWG G.I. Wire (Grade-2)
133Earthing Support (Coil Type)
134No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
13511KV XLPE COVERED CONDUCTOR 80 SQMM,AAA
136IPC for Covered-Covered Conductor 11 KV 80 Sqmm
137Non metallic ties for 11 kv covered conductor
138Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
139Danger Plate
140Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
141GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
142Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
143GI Bolts, Nuts & Washers of assorted size
14475X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
145No-6 GI Wire for road cross Guarding
146G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
14750x6mm GI Flat for earthing
148Black Paint
149Yellow colour paint for back ground
150Sunderies (Al Binding tape,Insulation tape, etc.)
151PART-II (Erection of 3Ph 6W LT Line with 4x95+1x95+1x16= 0.070 KM)1.1KV LT AB Cable 4X95+1X95+1X16
152CAP CABLE END FOR ABC 95 SQMM
153Suspension clamp with Eye hook
154Dead End Clamp suitable for bare messenger XLPE Aerial bunched cable
155EYE hook for XLPE Aerial bunched Cable
156Pole clamp for Eye Hook (For AB Cable)
157Piercing Connector
158Neutral Connector
159G.I. Nuts and Bolts
160Sunderies
161CIVIL PARTStay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2CUM @ 6500=0.2X6500 =Rs.1300
162Concreting of 11Mtr WPB Poles in ratio 1:1.5:3 = 0.450Cum. @ 6648.85 =0.450 x 6648.85 =Rs.2991.98
163Couping of Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648.85 =Rs.748.00
164Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
165Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
166Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
167PART-III (DISMENTALING)Dismantling of ACSR/AAAC 80/100 mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
168Dismantling of RSJ/WPB pole(116x100mm)
169Dismantling of all accesseries(Disc,pin insulator, v cross arm, danger board, steel structure of cut point from Single pole structure at 9/10/11/13 Mtr and transportation and stacking the materials at a proper place in safe position within 10km /site store and as per instruction of EIC.%_1
170Dismantling of PSC pole (9mtr)& return
171Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
172(Dig 4)PART-I (Erection of 3Ph 3W 11KV Line with 80sqmm cover conductor= 0.140 ckm)WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
173WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 (For Stud)
174MS 11 KV 'V' Cross Arm (10.2Kg Each)
175MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
176G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
177100X50X6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (6 Nos) including top piece
178Galvanisation of all RS and MS materials
17911 KV Disc Insulator (T & C) 45 KN Polymer
180Tension Assembly Wedge Type with Anchoring Clamp for 11 kV 80 Sqmm covered conductor
18111 KV Pin Insulator (polymer)
182H.T. Stay set complete
183H.T. Stay Insulator
184H.T. Stay Clamp (1.9Kg/pair)
1857/10 SWG G.I. Wire (Grade-2)
186Earthing Support (Coil Type)
187No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
18811KV XLPE COVERED CONDUCTOR 80 SQMM,AAA
189IPC for Covered-Covered Conductor 11 KV 80 Sqmm
190Non metallic ties for 11 kv covered conductor
191Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
192Danger Plate
193Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
194GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
195Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
196GI Bolts, Nuts & Washers of assorted size
19775X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
198No-6 GI Wire for road cross Guarding
199G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
20050x6mm GI Flat for earthing
201Black Paint
202Yellow colour paint for back ground
203Sunderies (Al Binding tape,Insulation tape, etc.)
204PART-II (Erection of 3Ph 6W LT Line with 4x95+1x95+1x16= 0.220 KM)9Mtr long 300Kg PSC Pole
205RCC Base plate
2061.1KV LT AB Cable 4X95+1X95+1X16
207CAP CABLE END FOR ABC 95 SQMM
208LT Stay Set (Complete)
209LT Stay Insulator
210LT Stay Clamp
2117/12 SWG GI stay wire
212Suspension clamp with Eye hook
213Dead End Clamp suitable for bare messenger XLPE Aerial bunched cable
214EYE hook for XLPE Aerial bunched Cable
215Pole clamp for Eye Hook (For AB Cable)
216Piercing Connector
217Neutral Connector
218Earthing Support (Coil Type)
219No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
220Danger Plate
221Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
222GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
223Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
224G.I. Nuts and Bolts
225Black Paint
226Yellow colour paint for back ground
227Sunderies
228CIVIL PARTStay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2CUM @ 6500=0.2X6500 =Rs.1300
229Concreting of 11Mtr WPB Poles in ratio 1:1.5:3 = 0.450Cum. @ 6648.85 =0.450 x 6648.85 =Rs.2991.98
230Concreting of 9Mtr/8Mtr PSC Poles in ratio 1:1.5:3 = 0.375Cum. @ 6648.85 =0.375 x 6648.85 =Rs.2493.32
231Couping of Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85= 0.1125x 6648.85 =Rs.748.00
232Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
233Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
234Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
235PART-II (DISMENTALING)Dismantling of ACSR/AAAC 80/100 mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
236Dismantling of PSC pole (9mtr)& return
237Dismantling of all accesseries(Disc,pin insulator, v cross arm, danger board, steel structure of cut point from Single pole structure at 9/10/11/13 Mtr and transportation and stacking the materials at a proper place in safe position within 10km /site store and as per instruction of EIC.%_1
238Dismantling of PSC pole (9mtr)& return
239Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
240(Dig 5)PART-I (Erection of 3Ph 6W LT Line with 4x95+1x95+1x16= 0.210 KM9Mtr long 300Kg PSC Pole
241RCC Base plate
2421.1KV LT AB Cable 4X95+1X95+1X16
243CAP CABLE END FOR ABC 95 SQMM
244LT Stay Set (Complete)
245LT Stay Insulator
246LT Stay Clamp
2477/12 SWG GI stay wire
248Suspension clamp with Eye hook
249Dead End Clamp suitable for bare messenger XLPE Aerial bunched cable
250EYE hook for XLPE Aerial bunched Cable
251Pole clamp for Eye Hook (For AB Cable)
252Piercing Connector
253Neutral Connector
254Earthing Support (Coil Type)
255No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
256Danger Plate
257Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
258GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
259Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
260G.I. Nuts and Bolts
261Black Paint
262Yellow colour paint for back ground
263Sunderies
264CIVIL PARTStay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2CUM @ 6500=0.2X6500 =Rs.1300
265Concreting of 9Mtr/8Mtr PSC Poles in ratio 1:1.5:3 = 0.375Cum. @ 6648.85 =0.375 x 6648.85 =Rs.2493.32
266Couping of Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648.85 =Rs.748.00
267Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
268PART-II (DISMENTALING)Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
269Dismantling of PSC pole (8mtr)& return
270(Dig 6)PART-I (Erection of 3Ph 6W LT Line with 4x95+1x95+1x16= 0.350 KM)9Mtr long 300Kg PSC Pole
271RCC Base plate
2721.1KV LT AB Cable 4X95+1X95+1X16
273CAP CABLE END FOR ABC 95 SQMM
274LT Stay Set (Complete)
275LT Stay Insulator
276LT Stay Clamp
2777/12 SWG GI stay wire
278Suspension clamp with Eye hook
279Dead End Clamp suitable for bare messenger XLPE Aerial bunched cable
280EYE hook for XLPE Aerial bunched Cable
281Pole clamp for Eye Hook (For AB Cable)
282Piercing Connector
283Neutral Connector
284Earthing Support (Coil Type)
285No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
286Danger Plate
287Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
288GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
289Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
290G.I. Nuts and Bolts
291Black Paint
292Yellow colour paint for back ground
293Sunderies
294CIVIL PARTStay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2CUM @ 6500=0.2X6500 =Rs.1300
295Concreting of 9Mtr/8Mtr PSC Poles in ratio 1:1.5:3 = 0.375Cum. @ 6648.85 =0.375 x 6648.85 =Rs.2493.32
296Couping of Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648.85 =Rs.748.00
297Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
298PART-II (DISMENTALING)Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. Transportation with adequete vehicle load/capacity shall be only paid seperately%_1
299Dismantling of PSC pole (8mtr)& return
300(Dig 7)PART-I (Erection of 33kV 13Mtr WPB Pole= 1 No)WPB 160x152 (30.44KG/Mtr.),13 mtr- with base plate 300x300x12
30133KV \\"V\\" cross arm(22Kg),GI
30233KV F Clamp
303GI Back Clamp for \\"V\\" cross arm(33KV)(1.7 kg each)
30433 KV Pin Insulator (polymer)
305Earthing Support (Coil Type)
306No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
30775X40X6 mm, GI Channel St Cross arm 2Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
308No-6 GI Wire for road cross Guarding
309G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
31050x6mm GI Flat for earthing
311Danger Plate
312Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
313GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
314Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
315GI Bolts, Nuts & Washers of assorted size
316Black Paint
317Yellow colour paint for back ground
318Sunderies
319CIVIL PARTMaterial for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
320Concreting of 13Mtr WPB Poles in ratio 1:1.5:3 = 0.550Cum. @ 6648.85 =0.550 x 6648.85 =Rs.3656.87
321Couping of Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85= 0.1125x6648.85=Rs.748.00
322PART-II (DISMENTALING)Dismantling of 10 Mtr. PSC (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC.%_1
323Dismantling of all accesseries(Disc,pin insulator, v cross arm, danger board, steel structure of cut point from Single pole structure at 9/10/11/13 Mtr and transportation and stacking the materials at a proper place in safe position within 10km /site store and as per instruction of EIC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56612225
AUTHORITY Government Departments
TENDER VALUE 33.54 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Electric Utility Shifting For The Work Improvement Of Kashinagar K Sitapur Road Such As Construction Of Reinforced Cement Concrete Drain And Widening With Paver Blocks From 12/900 Km To 13/425 Km In The District Of Gajapati Under State Plan For The Year 2025-26
Basic Detail
Tender No SE PKD RandB DIVN 04/2026 27
Bidding Type Tender
Location
City Gajapati
State Odisha
Key Dates
Publish Date 23 Jul 2026
Submission Date 06 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value 33.54 Lakhs
Tender Fee 6000
EMD 33600
Exemption Available
Document List
BOQ_602877.xls
d0bc6c8c-c269-4527-b36a-a38bf674b681.html
Tendernotice_1.pdf
Tendernotice_2 (6).pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_602877.xls

html

d0bc6c8c-c269-4527-b36a-a38bf674b681.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (6).pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders