Housing Urban and Rular Development Government Departments Closing in 15 days TDR #56612152

Tender For Design Construction Of Commercial Complex At Civil Township On Percentage Rate Basis.

Issued by Government Departments · Sundargarh, Odisha
Tender Value
11.28 Crore
Estimated cost
Bid Submission
19 Aug 2026
15 days left
EMD
11.29 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sundargarh → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Design Construction Of Commercial Complex At Civil Township On Percentage Rate Basis.

BOQ

Name of Work:- Design Construction of Commercial Complex at Civil Township on Percentage Rate Basis.
Sl. No. Item Description
1Design Construction of Commercial Complex at Civil Township on Percentage Rate Basis.
2Design Construction of Commercial Complex at Civil Township on Percentage Rate Basis. BILL OF QUANTITY FOR Design Construction of Commercial Complex at Civil Township on Percentage Rate Basis. Sl.No. Description of work Quantity UNIT RATE(Rs) AMOUNT(Rs)
3Earthwork in excavation in foundation trenches and column foundation and pits in different kinds of soil within an initial lift of 1.5M including dressing the sides and leveling the bed and depositing the excavated materials away from the site within an initial lead of 50.0 mtr. As per direction of the En­gineer-in-charge including cost of all labour, sundries, T&P, etc. complete. a Up to 1.5 m depth 2345.558 Cum 306.01 717764.2 b Between 1.50 to 3.0m depth 491.06 Cum 328.48 161303.39 c Between 1.50 to 3.0m depth 371.06 Cum 350.95 130223.51
4Backfilling of Excavated Earth (2/3 rd of Exacavation Qty)
5Disposal of excavated earth, slush, debrises etc within 5 km lead conplete
6Backfilling with Sand
7Slag filling
8Supply and spreading of good quality garden soil preferably red alluvial/sandy loam with texture neither too coarse nor too fine with a fair degree of water retaining capacity including cost of all materials, labour, labour cess, royalties, conveyance, applicable taxes and T&P etc.complete in all respect as directed by Engineer-in-Charge.
9Supplying & spreading of approved good quality cow dung manure well decomposed garbage free including loading, unloading and delivery at site with all leads and lifts including cost of all materials, labour, labour cess, royalties, conveyance, applicable taxes and T&P etc.complete in all respect as directed byEngineer-in-Charge.
10Providing and laying cement concrete (1:4:8) in foundation using 40mm size black hard crusher broken granite metal of approved quality from approved quarry including mixing with concrete mixer, lowering, laying and compacting to proper thickness, watering and curing for the required period as per direction of Engineer-in-charge including cost of all materials, labour, taxes, royalties, transportation, sundries and T&P etc. complete
11OHT Waterproofing: Substrate preparation for construction joint: Cleaning of RCC joint surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions. Sealing of penetrations: Providing and applying Sikagard-694 F(I) or equivalent, solvent free, moisture insensitive epoxy resin based putty like material that can be used for bonding and sealing different construction materials. This shall be applied by making 10 mm seal all around the pipe penetrations. Waterproofing coating: Providing and applying of SikaTop-107 Seal IN or equivalent ready to use 2 component acrylic cementitious waterproofing coating comprising of 2 coats of equal consumption of 1.5 kg/sqm and reinforced with glass fabric cloth Sika Fabric-50 applied over a saturated surface. The 2 coats must be applied at right angle to each other with a brush. The coating must be taken to a height of 300 mm on walls and 600 mm in splash area. Food grade protective coating: Providing and applying of Sikagard-67 or equivalent, water based, solvent free, odourless, epoxy resin protective coating, according to specification. The coating must conform to USFDA 175.300, IS 13239 – 1991, IS- 101(Part 6, Sec 3) - 1990 and must have a mixed resin density of ~1.22 kg/L at +27 °C & solid content of ~49 % (by weight). The coating must be applied in 3 coats, first coat of primer diluted by 20% clean water and 2 coats of 0.25 kg/sqm each and as per the instructions of the manufacturer's product data sheet.
12UGT Waterproofing: Substrate preparation for construction joint: Cleaning of RCC joint surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions Providing and Applying Sikagard®-5310 or equivalent Coal Tar is used as a protective chemical resistant coating for concrete, as internal and external coating for buried and submerged structures in wastewater, seawater or highly aggressive soils .
13Providing and laying in position design mix M-20 grade cement concrete using cement content as per approved design mix, including poring, compaction but excluding the cost of centering, shuttering, finishing and reinforcementas per direction of Engineer-in-charge.
14Providing and fixing perforated RCC precast slab of M-20 grade with 20mm & down grade black hard granite (crusher broken) stone chips including hoisting & laying, centering, form work but excluding reinforcement.
15Providing and laying in position design mix M-25 grade cement concrete using cement content as per approved design mix, including poring, compaction but excluding the cost of centering, shuttering, finishing and reinforcement, as per direction of Engineer-in-charge. a Below ground up to 4.5m depth 182.953 Cum 6381.55 1167523.72 b Ground floor 559.98 Cum 6336.82 3548492.46 c First Floor 280.12 Cum 6445.37 1805477.04 d Second Floor 282.64 Cum 6570.19 1856998.5 e Third floor (Terrace floor) 82.87 Cum 6713.74 556367.63
16Supplying TMT steel reinforcement bars of grade FE 500of required diameters of approved quality including straightening, cutting to size, bending, and binding the reinforcement,lifting and placing in position as per design complete including cost of bars , binding wires 18 gauge, including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants, etc. complete as per the direction of the Engineer-in-charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights) a Ground Floor and below 1082.08 Qtl 9539.01 10321971.94 b First Floor 355.67 Qtl 9568.65 3403281.75 c Second Floor 353.82 Qtl 9599.8 3396601.24 d Third Floor 103.72 Qtl 9632.49 999081.86
17Providing strong, rigid and leveled and plumbed centering and shuttering to required shape and size for all kinds of RCC works in the items mentioned below with steel/ wooden centering materials with all necessary bracing and ties and supports with level centering covered with polythene sheet including provision of necessary holes and pockets for electrical conduit pipe P.H.pipes, fan hooks or boxes, switch and board insert plates, clamps and extension bars etc. as per the direction of the Engineer-in-charge and dismantling and removing after the required interval from the date of casting, including cost of all materials with transportation, taxes, loading and unloading etc. and all labour, sundries, T&P scaffolding etc. complete. i Foundation (below ground up to 4.5m depth 723.25 Sqm 260.88 188681.46 ii Column & Beam 0.0 0.0 a Below ground up to 4.5m depth 428.87 1364.39 585145.94 b Ground floor 2499.19 Sqm 1219.7 3048262.04 c First Floor 987.2 Sqm 1328.22 1311218.78 d Second floor 987.2 Sqm 1453.02 1434421.34 e Third floor 340.75 Sqm 1596.54 544021.01 iii Chajja, Shelves & Roof slab 0.0 Sqm 0.0 a Ground Floor 2193.36 769.2 1687132.51 b First Floor 1006.36 sqm 819.84 825054.18 d Second Floor 1006.357 sqm 878.07 883651.89 e Third floor 138.17 sqm 945.06 130578.94 iv Stair case 0.0 sqm 0.0 a Ground Floor 77.33 sqm 1068.86 82654.94 b First Floor 77.33 sqm 1282.62 99185.0 c 2nd floor 77.33 1544.0 119397.52 v Lintel 0.0 Sqm 0.0 a Ground floor 203.48 Sqm 577.75 117560.57 b First Floor 193.63 Sqm 604.31 117012.55 c Second floor 174.71 Sqm 634.86 110916.39 d Third floor 32.7 Sqm 669.98 21908.35 vi Vertical Wall 0.0 0.0 a Ground floor 743.52 Sqm 1087.56 808622.61 b tHIRD floor 107.36 Sqm 1412.65 151662.1
18Brick work using fly ash brick of size 23cm x 11cm x 8cm having crusing strength between 75 to 99kg/cm in cm(1:6) in foundation and plinth curing, cost conveyance of all materials etc. complete. Foundation & upto plinth level
19Brick work using fly ash brick of size 23cm x 11cm x 8cm having crusing strength between 75 to 99kg/cm in cm(1:6) in superstructure curing, cost conveyance of all materials etc. complete a Ground Floor 487.47 Cum 5638.85 2748770.21 b First Floor 337.5 Cum 5803.27 1958603.63 c 2nd Floor 320.43 Cum 5927.88 1899470.59 d 3rd Floor 101.27 Cum 6071.19 614829.41
20Providing and applying 12 mm thick plaster to even side of wall in cement mortar (1:6) on all types of surfaces using coarse clean sand including surface preparation, curing both the coats, roughening the first coat for making key for the next coat ,bends, pattas, grooves, drip moulds, etc. and all scaffolding, curing etc., including cost of all materials, labour, labour cess, royalties, conveyance, applicable taxes and T&P etc.complete in all respect as directed by Engineer-in-Charge. a Ground floor 1943.053 sqm 190.22 369607.54 b First Floor 1534.644 sqm 194.36 298273.41 c Second floor 1329.624 sqm 198.64 264116.51 d Third floor 398.076 sqm 203.03 80821.37
21Providing and applying 16 mm thick plaster to un even side of wall in cement mortar (1:6) on all types of surfaces using coarse clean sand including surface preparation, curing both the coats, roughening the first coat for making key for the next coat ,bends, pattas, grooves, drip moulds, etc. and all scaffolding, curing etc., including cost of all materials, labour, labour cess, royalties, conveyance, applicable taxes and T&P etc.complete in all respect as directed by Engineer-in-Charge. a Ground floor 3566.87 sqm 275.62 983100.71 b First Floor 1694.24 sqm 281.82 477470.72 c 2nd Floor 1723.84 sqm 288.21 496827.93 d 3rd Floor 616.43 sqm 294.8 181723.56
22Providing and applying 6-12 mm thick plaster to RCC surface in cement mortar (1:3)using coarse clean sand including surface preparation, curing both the coats, roughening the first coat for making key for the next coat ,bends, pattas, grooves, drip moulds, etc. and all scaffolding, curing etc., including cost of all materials, labour, labour cess, royalties, conveyance, applicable taxes and T&P etc.complete in all respect as directed by Engineer-in-Charge. a Ground floor 147.83 sqm 214.19 31663.71 b First floor 93.83 sqm 218.33 20485.9 c Second floor 93.83 sqm 222.59 20885.62 d 3rd floor (Terrace) 85.0 sqm 226.99 19294.15
23Providing Plastic Emulsion on internal walls - 2 coats with primer a Ground floor 2270.921 Sqm 187.4 425570.6 b First Floor 1703.95 Sqm 192.29 327652.55 c 2nd Floor 1528.53 Sqm 197.41 301747.11 d 3rd Floor 247.5 Sqm 202.73 50175.68
24Providing texture paint Rustic texture (trowel) - minor repair with putty + 1 coat of primer+1 coat of rustic texture+2 coats of appex paint , make Shalimar/Dulex/Asian including cost of scafolding
25Providing and applying Wall painting Two coats with weather coat paint of approved shade including cost of scafolding. a Ground floor 1430.0 Sqm 180.51 258129.3 a First Floor 872.54 Sqm 185.41 161777.64 b 2nd Floor 872.54 Sqm 190.53 166245.05 c 3rd Floor 326.36 Sqm 195.85 63917.61
26Finishing wall surface with Acrylic wall putty including cost of scafolding a Ground floor 4802.671 Sqm 92.34 443478.64 b Fisrt Floor 2576.49 Sqm 94.03 242267.35 c 2nd Floor 2401.07 Sqm 95.76 229926.46 d 3rd Floor 573.86 Sqm 97.55 55980.04
27Providing and laying premium grade Vitrified tiles having thickness of 8mm to 10mm in sizes as decided by engineer, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade over 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. in floors, trades of step etc. as directed by Engineer-in-Charge. a Ground floor 897.991 Sqm 1182.81 1062152.73 b First Floor 765.86 Sqm 1233.81 944925.73 c Second Floor 773.91 Sqm 1287.36 996300.78
28Providing and laying premium grade Kota Stone having thickness of16mm in sizes as decided by engineer, over 25 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. in floors, trades of step etc. as directed by Engineer-in-Charge.
29Providing and fixingceramic tiles in dados skiring and risers of steps on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shade of the tiles including cost of ceramic wall tiles of approved shade b Ground floor 100.08 Sqm 942.42 94317.39 b 1st floor 258.0 Sqm 960.38 247778.04 c 2nd floor 100.485 Sqm 979.22 98396.92
30Supplying & fixing of PVC frame casement windows and doors with Outer frames, suitable shutters and 13.2mm laminated glass including all necessary hardware, EPDM Rubber, Hinges, fittings, fixtures, pivots etc., all complete. . All materials, suppliers shall be approved by Engineer-incharge/client/Consultant.
31Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 Mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffinhg, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for the work complete in all respect.
322.5cm. thick grading concrete (1:2:2) on roof slab.
33Providing and laying water proofs with polymeric bituminous membrane (Plastic flet) of 2.25 Kg / Sqm and 2mm thickness consisting of layers having center core of 20 microns thermoplastic high molecular high density polyethylene M.H.H.D.P.E. film of grade 2504 including priming the surface with bituminous primer @ 0.3 Kg / sqm providing a coat of hot blown bitumen of 1.32 Kg / Sqm applying and laying plastic felt membrane with 10cm overlap adhered to blown bitumen of 85/25 or 90/15 grade and covered with a layer of hot blown bitumen @ 1.2 Kg / Sqm etc. complete.
34Supply of WPC door frame of size 50 x 125mm of required length and width, fixing on brick/RCC surface with 6 nos anchor fastener (3 nos each side) including stainless steel screw.Supply of 30mm thick WPC door panels of required width and height, fixing with WPC door frame by fixing of 3 nos 6 inch stainless steel hinges. The door panel shall be provided with two 25 x 125mm bright finished stainless steel handle (One on front and another on back side) and three nos 200mm bright finished stainless steel tower bolt (one on front side, one on back side horizontal and one on back side vertical top) and all required locking arrangements.
35Supplying and fixing rolling shutter of approved make made of 80x1.25 mm m.s. laths interlocked together through their entire length and jointed together at the end by end locks mounted on especially designed pipe shaft , with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete with spring and ball bearings, top cover, with primer paint and painting etc complete. as per detailed specifications and direction of Engineer.
36Providing fitting and fixing of gypsum false ceilling with aluminium anodised T Section No. 3215 with 2'-0\\" centr to center, L Section No.1705 up to 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the aluminium grid 2'-0\\" x 2'-0\\" suspended from ceiling etc. complete. a Ground floor 604.6 Sqm 1382.32 835750.67 b First Floor 660.24 Sqm 1390.8 918261.79 c Second floor 600.19 Sqm 1399.55 839995.91
37Providing fitting and fixing of false ceilling using 12 mm thick Calcium SIlicate board of size 600 x 600mm with aluminium anodised T Section No. 3215 with 2'-0\\" centr to center, L Section No.1705 up to 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the aluminium grid 2'-0\\" x 2'-0\\" suspended from ceiling etc. in required design and coving as per direction of engineer complete. a Ground floor 31.78 Sqm 1758.04 55870.51 b First floor 38.12 Sqm 1766.52 67339.74 c Second floor 31.28 Sqm 1776.28 55562.04
38Providing, welding, bolting structural steel such angle, channels, errecting, , fixing in position for gate, grills etc as per direction of engineer including required nuts & bolts
39Finishing with Synthetic Enamel (two coats) over one coat of primer at all locations prepared and applied as per manufacturer’ specifications
40Providing and fixing 12mm thick poly carbonate sheet of approved design and quality drilling hole in wind ties including fixing of ridges valleys wind ties etc. excluding cost of fittings.
41Providing and fixing 6mm thk Suede finish HPL Exterior grade compact laminates made up of 1300 x 3050 in size and manufactured under EN438-2&3:2005 standard. CLAD should be made with GLE Technology & Double layer UV protection process under high pressure thermosetting Phenolic resign gtreated exclusively & certified exterior Grade Decorative paper (UV resistant) on both side with high grade kraft paper in between. Both the decorative and kraft paper to be made of virgin pulp. CLAD should be resitance to water immersion characteristic with permissible increase in thickness and mass <0.60% and have density >1.35 g/cm3, UV resistance on Grey scale measurement will be measured >=4, with flame retardant fulfilled the criteria of under EN13501-1:2007 with classification of BS100 standard property, Moisture resistant, impact resistant, high pressure thermsetting resign treated balanced compact laminates. CLAD will be installed on aluminium tubes 1t 500mm c/c distance with special L brackets. There will be special fixing treatment on all the corner sections. Aluminium box size will be 25mm x 50mm x 2.5mm. Boards will be fixed on the aluminium channel with color match rivets through 8mm drill hole in boards and 5mm dia drill holes in aluminium box. Rivets will be installed by automatic rivet guns. Cost is inclusive of Alumiium section 50 x 25x1.5mm powder coated frame and hardwares complete.
42Add for CNC cutting
43Providing Supply & Instalaltion of GFRC (Glass Fibre Reinforced Concrete) Elements as per the approved size and shape. The GFRC Elements will be made in White Portland Cement of '53 grade ‘White Portland Cement manufactured by 'Birla' or equivalent Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by 'NEG Japan' or Cemfil (OC), Super Plasticizers (HP- 3) manufactured by Samrock or equivalent, Polymers (SBR MC-76) manufactured by Dow'' or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany). The GFRC Screen casting will be done using the 'Spray machine in the GFRP or Rubber molds manufactured in HS Architectural Solutions Only. The installation of the GFRC Elements shall be done as per the approved shop drawing by using the anchor fasteners, nut bolts, screws and cleats as per the site requirements.GRC screen 30mm thick and 40mm thick
44Providing, installation, testing and commissioning of 8 passnager lift MRLS
45Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018.
46Supply and planting well developed tree of 6feet height, well branched in polybag 15x16 cm of approved mix of species including cost of all materials, labour, labour cess, royalties, conveyance, applicable taxes and T&P etc.complete in all respectas directed by Engineer-in-Charge. a Neem 30.0 Nos 437.0 13110.0 b Kadamba 30.0 Nos 402.5 12075.0 0.0 0.0 PH works 0.0 0.0
47Providing and fixing to wall or ceiling and floor uPVC pipes class conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification complete. 80mm dia 30.0 Rm 975.8 29274.0 65mm dia 122.0 Rm 738.5 90097.0 50mm dia 157.0 Rm 531.8 83492.6 40mm dia 264.0 Rm 428.6 113150.4 32mm dia 52.0 Rm 325.9 16946.8 25mm dia 192.0 Rm 247.9 47596.8 20 mm dia 124.0 Rm 197.4 24477.6 15 mm dia 96.0 Rm 153.0 14688.0
48Providing and fixing of Brass or Gun Metal Full Way Valve conforming to IS:781-1995 of the following nominal sizes with wheel as per specification complete. 80mm dia 1.0 Nos 9584.4 9584.4 65mm dia 2.0 Nos 6986.0 13972.0 50 mm dia 3.0 Nos 3824.9 11474.7 40mm dia 7.0 Nos 2580.5 18063.5 32mm dia 2.0 Nos 2030.6 4061.2 25mm dia 1.0 Nos 1387.1 1387.1
49Providing and Fixing of Gun Metal Check or Non-return Valve Class - I conforming to IS : 5312 (Part-I) - 2004 of the following nominal bore as per specification complete 40mm dia 1.0 Nos 2343.2 2343.2
50Supplying all labour and T&P for fixing Brass screw down Stop cock of the following size as per specification all complete 15mm dia 40.0 Nos 602.9 24116.0 20mm dia 40.0 Nos 1048.5 41940.0
51Providing and fixing white vitreous china extended wall mounting water closet of size 580 x 440 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. . W.C. pan with ISI marked white solid plastic seat and lid Polytuf 5006 or equivalent
52WASH BASIN: White vetrious china 550 x 400mm washbasin with 15mm C.P. brass pillar tap . Supplying all materials,labour and T&P for fixing wash hand basin with hole for pillar cock with cast iron /M.S. brackets painted white including cutting holes in walls and making good to the damages etc. all complete as per specification and direction of engineer in charge.
53Fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin complete as per specification
54Providing and fixing of 15 mm C.P brass pillar tap including all fittings and accessories complete
55Supplying, Installing, Testing and Commissioning Health Faucet with 1200 mm Long CP Braided Hoses including connectors, adapters, GI nuts, bolts, washers, check nuts,C.P. brass two in one bib tap including necessary sleeve flanges, cock , angle valves and all other fittings/ accessories required for satisfactory installation complete. Make Hindware F160013 or Polytuf 3008 or equivalent
56Providing and fixing bowl pattern urinal conforming to IS 2556 : Part 6-1996 including connecting the urinal of 430x260x350 mm or 340x410x265 mm sizes respectively with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification. Vitreous China - Flat Back Urinal of 430mm x260mm x350mm size
57Fixing PVC waste pipe of following nominal diameter for wash basin or sink including brass check nut complete as per specification. 32 mm dia
58MIRROR: Supplying all materials,labour and T&P for fixing (600mmx450mm.) bevelled edge mirror of superior glass mounted on 6mm. thick A.C. sheet or ply-wood sheet and fixed to wooden plugs with chromium plated brass screws and washers etc.all complete as per specification
59Supplying all materials,labour and T&P for fixing cast (spun) iron floor traps of the following nominal diameter of outlet, of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm including cutting holes in walls and making good to the damages etc. all complete as per specification.[3.3.17./352]
60Chamber with R.C.C top slab in (1:1½:3) mix, foundation concrete (1:4:8), inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:5), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber complete as per specification.
61Making connection of drain or sewer line with existing Manhole including breaking into and making good the walls, floor with cement concrete (1:2:4), cement plastered on both sides with cement mortar (1:3) finished with a floating coat of neat cement and making necessary channels with cement concrete (1:2:4) for the drain all complete as per specification.
62providing and Laying (to level or slopes) and jointing with rubber rings pre-cast reinforced socket and spigot concrete pipes Class NP-2 conforming to IS:458 - 2003 suitable for rubber ring roll on joint of the following internal diameter as per specification complete.(Earthwork in trenches to be measured and paid for separately). 150mm dia
63Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. Cost includes all type of fittings and secials such Tee, bend etc b 110mm dia 712.0 Rm 450.6 320827.2 c 75mm dia 200.0 Rm 274.5 54900.0
64Supplying all materials,labour and T&P for cutting holes through existing brick work including making good to the same in cement mortar(1:4) for taking G.I. pipes and fittings /P.V.C. pipes and fittings all complete as per specification.
65Supplying all materials,labour and T&P for cutting holes in R.C.C. floors and roofs up to 19 cm. thick including making good and leak proof to the damages for taking G.I. pipes and fittings /P.V.C. pipes and fittings all complete as per specification. (per each.)
66Providing and fixing standard sized Chromium Plated brass towel rail complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification.
67Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Agaria Marble Stone
68Supplying, Installing, testing and commissioning approved make horizontal submersible pump made of C.I construction suitable for building application & IP - 68 enclosure . The quoted rate shall also include for providing necessary safety devices viz. dry run protection, over load relays auto level controller with necessary cables etc., complete working on440V,50Hz, three phase system. Pump at under ground sump to pump water to OHT (1W+1S) 4 lps and head of 40m including panel
69Sinking of 200mm / 150mm dia production well through DTH Rig -Supplying all labour, T&P for drilling a perfectly vertical bore hole of specified dia for specified depth below GL through consolidated & unconsolidated rock with combination drilling rig as required to suit the site conditions including use of own rig with its accessories of 200/150mm dia PVC/GI/MS pipe for housing fitted with socket & with or without well screen as per the necessity for the soft, medium, hard & boulder formation. (PVC/GI/MS casing pipes if required to prevent collapse of over burden is to be fitted by the contractor including lowering & withdrawing after completion of tube well). 200mm dia to 400mm dia in over burden portion including packing of gravel supplied by the contractor for 400mm bore only tec.200mm dia bore a Drilling of 200mm. dia.(0.00mtr to 30.00mtr.) 30.0 Rm 2999.6 89988.0 b Drilling of 200mm.dia.(30mtr to 50.00mtr.) = 20.0 Rm 3303.5 66070.0 c Drilling of 150mm.dia.(50mtr to 200mtr.) = 100.0 Rm 2175.3 217530.0
70Supplying all labour, T & P for lowering the following size PVC casing pipe with or without slotted pipes as per the necessity from G.L up to required depth & fitted & fixed up in perfectly vertical position including cutting & threading & slotted pipes & supplying & fixing all jointing materials T & P etc all complete & keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials etc all complete as per the direction of EIC200mm dia PVC casing pipe
71Supplying all labour and T & P for cleaning & developing the tube well with their own compressor continuously worked till clear & adequate discharge is obtained from the tube well including supply & use of all necessary equipments & labour charges etc complete.
72Supply of 200mm dia PVC pipe Sch-80
73Supply of 200mm dia PVC pipe strainer pipe Sch-80
74Supplying, fitting and fixing of 1\\"size nylon rope of approved quality for lowering and tying of Submserssible pump in bore well complete as per direction of engineer in charge.
75Suply of ISI marked barbed weir
76Fixing barbed wire fencing and post by means ofstaples and straining hooks by means o.f tying with G.I. wire andj including cost of staples, hooks and tying wires Fire 0.0 0.0
77TERRACE FIRE PUMP(A) Supplying, installation, testing and commissioning of electric driventerrace pump suitable for automatic operation and consisting offollowing, complete in all respects, as required: (Terrace Pump)(B) Horizontal type, multistage, centrifugal, split casing pump of castiron body & bronze impeller with stainless steel shaft, mechanicalconfirming to IS : 1520(C) Suitable HP squirell cage induction motor T EFC type suitable foroperation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class ofprotection for enclosure, horiziontal foot mounted type with Class-'F'insulation, conforming to IS-325.(D) M.S. fabricated common base plate, coupling, coupling guard,foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with antivibration pads.900 lpm at 35 m Head
78PIPES WORK (INTERNAL)Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class-II of 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Note:-1. MS Fittings(less than 40 mm dia shall be Forged Steel fittings as per ASTM A 105 3000CL, end connection Socket welded as per ASME B16.11. & one side socket weld and other side threaded as per NPT for fittings used for sprinklers2. M.S Fittings of 50 mm dia & above shall be as per ASTM A 234 Gr. WPB all fittings shall be BW fittings type as per specifications.3. Colour/shade of Paint shall be as per specification/drawings and as directed by Engineer In Charge. a 100 mm dia 75.0 Metre 3271.77 245382.75 b 80 mm dia 10.0 Metre 2421.13 24211.3 c 65 mm dia 5.0 Metre 2078.75 10393.75 d 25 mm dia 20.0 Metre 978.24 19564.8 VALVES (INTERNAL) 0.0 0.0
79Supplying, fixing, testing and commissioning of Butterfly valve of PN 16 rating with C.I body , Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia
80Supply, lnstallation, testing and Commissioning of Male/ female screwed end full way lever operated forged brass Ball valve of PN 16 rating brass body with forged brass hard chrome plated ball & teflon seat, with (threaded joints) complete as required. including necessary teflon tape etc complete as per specification as specified inclusive of all accessories required for satisfactory installation as per specification/drawings and as directed by Engineer In Charge.25 mm dia
81Providing, installation, testing and commissioning of non-return valve of PN 16 rating of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :Note :Colour/shade of Paint shall be as per specification/drawings and as directed by Engineer In Charge. i 100 mm dia 2.0 Nos 12603.29 25206.58 ii 80 mm dia 0.0 Nos 0.0
82Supply, lnstallation, testing and Commissioning of UL Listed/ FM Approved Ductile Iron Body Air Release Valve for risers, suitable for pressure not less than 175 PSI as per specification, inclusive of all accessories required for satisfactory installation as per specification/drawings and as directed by Engineer In Charge.25 mm dia
83Providing, installation, testing and commissioning of C.I body Y- strainer screen fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with C.I double flange.Note :Colour/shade of Paint shall be as per specification/drawings and as directed by Engineer In Charge.100 mm dia INTERNAL HYDRANT ACCESSORIES 0.0 0.0
84Supplying and fixing single headed internal Hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Note :Colour/shade of Paint shall be as per specification/drawings and as directed by Architect / Engineer in charge .Single headed Stainless Steel
85Supplying & fixing 63 mm dia Stainless Steel Short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneousconnection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
86Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636.Stainless Steel (Grade 304)(type-A) as required
87Supply, Installation, Testing and Commissioning of First-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket.Note :Colour/shade of Paint shall be as per specification/drawings and as directed by Architect / Engineer in charge . 30 m
88Providing & fixing lockable indoor type Fire Hose Cabinet, frames fabricated from 40 x 40 x 5 angle iron sections and 16 gauge MS sheet with glass door (with M.S. frame) and locking arrangement, suitable to accommodate landing valves, 2 nos. 15 m long hoses, first-aid hose reel and branch pipe nozzle & fire mans’ axe. The cabinet frame shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade of as required (Approx 1.5 m (high) x 0.9 m (wide) x 0.6 m (deep) ). The item shall be complete of MS housing with front door Colour/shade of Paint shall be as per specification/drawings and as directed by Architect / Engineer in charge .
89Supplying and fixing standard Fireman Axe with heavy duty insulated rubber handle as per IS: 926 with clamps as per specifications
90Supply, lnstallation, testing and Commissioning of Fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :Note :Colour/shade of Paint shall be as per specification/drawings and as directed by Architect / Engineer in charge . 2 way-100 mm dia M.S. Pipe
91Supplying and fixing Orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required as per specifications.Note:-The bore of the orifice shall be designed by the Contractor in order to get hydrants valve outlet pressure of 3.5 kg/cm2”.
92Supply & Fixing of \\" J \\" type hooks supports made of 25 mm dia MS pipe to support 2 nos. 15 m long hoses and 01 No short branch pipe. Cost should be inclusive of required anchor fastner, nuts, etc as per specifications INSTRUMENTATION 0.0 0.0
93Providing and fixing in position the industrial type Pressure gauges with gun metal / brass valves complete as required FIRE EXTINGUISHER SYSTEM 0.0 0.0
94Supply, lnstallation, testing and Commissioning of Carbon Dioxide (CO2) type Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by Architect / Engineer in charge . 4.5 kg.
95Supply, lnstallation, testing and Commissioning of ABC Dry Chemical powder Mono-Ammonium Phosphate (MAP)-90% (stored pressure) type - 6 kg Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by Architect / Engineer in charge .
96Supply, lnstallation, testing and Commissioning of Mechanical Foam type (AFFF media) 60 Liter. cylindrical shape fire extinguisher with gas cartridge, hose and all required accessories, complete as per IS:15683 - trolley mounted type for portable use as per technical specifications with all the necessary accessories as required for complete installation shall also be included as per specification/drawings and as directed by Architect / Engineer in charge .
97Supply, Installation of Floor mounted bucket stand with GI buckets to hand 4 nos. of 9 ltrs buckets sand filled (as per IS: 2546). The stand shall be 5'(L) x 3'(H) x 2\\"(W) made out of 30 x 300 x4mm MS angle frame duly coated with 2 coats of red oxide primer & 2 coats of red finish paint as per specification/drawings and as directed by Engineer In Charge. ELECTRICAL PANELS, STARTER PANELS, CABLES, TERMINATIONS 0.0 0.0 STARTER ISOLATOR PANELS 0.0 0.0
98Design, supply, installation, testing and commissioning of local starter panels with (IP55) enclosure made up of Double CRCA sheet steel of 2/4 mm thick for frame work and covers with hinged lockable doors , on surface/ recess suitable for mounting 11kW Star/Delta Starter for Booster pumps complete with connections, etc. as required. The enclosure shall withstand 200 deg for 2 hours.The local starter panel shall be complete with all necessary Power & control circuit breakers like MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors, with E/F Protection contactors, SPPR, Start/Stop push buttons, On/Off/Trip indication lamps, auto/manual selector switches, terminal blocks, Analog Ammeter with CT etc and must have arrangement to receive BMS & fire signal input. All protective equipment /component rating shall be as per type 2 coordination chart. The panel suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection shall be of min. IP42 Protection for indoor & IP55 for outdoor applications.All hardware required for mounting of local starter panel in wall/floor shall be included in the local control panel itself. MV CABLE AND CABLE LAYING 0.0 0.0
99“Supply, loading, transportation unloading and storages at site , shifting from storage place to site of following sizes of Stranded Annealed Bare Copper Conductor , 950° for 3 hours Mica Tape Wrapped, Xlpe Insulation, Cores Laid up together, Fiber Glass Tape Wrapped, LSZH Inner Sheathed, GI Wire Strip Armoured, LSZH Outer sheathed Fire Survival Cables of 1.1 KV grade conforming to BS 7846 amended up to date, and cable should pass circuit integrity test as per BS 6387.16 Sq.mm x 3C Cu. Fire Survival Cable
100Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
101Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm(clamped with 25x3mm MS flat clamp) MV CABLE TERMINATION 0.0 0.0
102Supplying and making end termination with brasscompression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3C 16 sqmm CABLE TRAYS 0.0 0.0
103Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
104Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
105Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
106Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
107Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Reducer\\"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness Electrical 0.0 0.0 A Wiring-: 0.0 0.0
108Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C 585.0 point 1309.82 766244.7
109Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (i) Group A 69.0 point 579.46 39982.74 (ii) Group B 214.0 point 672.32 143876.48 (iii) Group C 50.0 point 766.07 38303.5
110Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. a 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 200.0 Metre 208.04 41608.0 b 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 934.0 Metre 245.54 229334.36 c 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 2114.0 Metre 298.21 630415.94 D 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 150.0 Metre 673.21 100981.5
111Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the samein case of recessed conduit as required. a 20 mm 1233.0 Metre 114.29 140919.57 b 25 mm 450.0 Metre 129.46 58257.0 c 32 mm 250.0 Metre 164.29 41072.5
112Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
113Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
114Installation, testing and commissioning of pre-wired, LED Light fittings of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
115Installation, testing and commissioning of ceiling fan on down rod or wall fan on the existing ceiling /surface, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
116Spply and Fixing of Two Module Stepped type electronic fan regulator on the existing Modular Plate Switch Box including connections but excluding modular plates etc. as required
117Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a 1 or 2 Module (75mmX75mm) 10.0 Nos 266.07 2660.7 b 3 Module (100mmX75mm) 71.0 Nos 291.96 20729.16 c 4 Module (125mm x 75mm) 80.0 Nos 306.25 24500.0 d 6 Module (200mm x 75mm) 28.0 Nos 358.93 10050.04 e 8 Module (125mm x 125mm) 213.0 Nos 405.36 86341.68
118Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a Modular blanking plate 100.0 Nos 35.71 3571.0
119Supply and Fixing 20A, 240V, SPN Industrial type socket outlet, with 2 Pole and earth, metal enclosed plug top alongwith20A C Curve, SP, MCB in sheet steel enclosere. B EARTHING-: 0.0 0.0
120Earthing with GI earth pipe 4.5 Mtr long , 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke & salt as required.
121Earthing with Copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
122Supplying and laying 50 x 10 mm strip GI Strip at 0.50 m below ground as strip earth electrocde, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer sapced at 50mm).
123Supplying and laying 40 x 10 mm strip GI Strip at 0.50 m below ground as strip earth electrocde, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer sapced at 50mm).
124Supplying and laying 40 X 5/6 mm strip GI Strip at 0.50 m below ground as strip earth electrocde, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer sapced at 50mm).
125Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. C Lightning Protection System-: 0.0 0.0
126Providing and fixing G.I. tape 25 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
127Providing and fixing G.I. tape 25 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
128Providing and fixing testing joint, made of 25 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck,nuts and spring washers etc. complete as required.
129Earthing with GI earth pipe 4.5 Mtr long , 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke & salt as required. D Pole, Fitting & Fixture-: 0.0 0.0
130Supply, Installation, Testing & Commissioning of 250 mm dia Exhaust Fan. Make - As per approved make list of agreement.
131Supply, Installation, Testing & Commissioning of 1200 mm five star energy efficient ceiling fan. Make - As per approved make list of agreement.
132Supply, Testing & commissioning 36 Watt LED luminaries of minimum 100Lm/Watt, 50K burning hours,CCT 5700K. Make - As per approved make list of agreement.
133Supply, Testing & commissioning 24 Watt LED luminaries of minimum 100Lm/Watt, 50K burning hours,CCT 5700K. Make - As per approved make list of agreement.
134Supply, Testing & commissioning 20 Watt LED luminaries of minimum 100Lm/Watt, 50K burning hours,CCT 5700K. Make - As per approved make list of agreement.
135Supply, Testing & commissioning 15 Watt LED luminaries of minimum 100Lm/Watt, 50K burning hours,CCT 5700K. Make - As per approved make list of agreement.
136Supply, Testing & commissioning 10 Watt LED luminaries of minimum 100Lm/Watt, 50K burning hours,CCT 5700K. Make - As per approved make list of agreement.
137SITC of 200W LED Flood Light. Make - As per approved make list of agreement.
138SITC of 12.5 Mtr. High Mast including Raising lowering system, Foundation bolt & Aviation light and other required accessories. Make - As per approved make list of agreement.
139SITC of 80W LED Street Light. Make - As per approved make list of agreement.
140SITC of 9 Mtr. Street Light Pole, Foundation bolt and other required accessories. Make - As per approved make list of agreement. E Panel & DB-: 0.0 0.0
141Main LT Panel (Outdoor Type - IP55 With Canopy as per IS-61439)Incomer 1:800A FP EDO ACB (50kA) with microprocessor based O/L, S/C and E/F - 1 No. Suitable for 3 runs 300 Sqmm Cable Termination.R Y B, on, off, trip indication lamp - 1 set.Digital Ameter and Voltmeter - 1 set.SPD type-II within Panel, Min. 50KA, FP - 1 No.Multi Function Meter with CT RS 485 port.- 1 No.C.T. 800/5A, CLASS 1.0, 15VA- 1 set.Busbar:-1800A FP AL. busbar (50kA)Outgoing from Bus-1:A. 500A FP MCCB (36kA) with microprocessor based 36kA - 1 no.B. 400A FP MP Based MCCB with O/L, S/C & inbuilt E/F 36kA - 2 nos.C. 200A FP MP Based MCCB with O/L, S/C & inbuilt E/F 36kA - 3 nos.D. 63A FP MCB, 10kA - 6 nosE. 32A FP MCB, 10kA - 2 nos
142APFC Panel (Outdoor Type - IP55 With Canopy With Canopy as per IS-61439)APFC Panel Non-Compartmentalized Type, Free Standing, Floor Mounted with 14% detuned harmonics filter No of Stage 12(3X50KVAR + 4X10 KVAR ) - 190KVAR
143Building Common Area Panel (Outdoor Type - IP55 With Canopy - PTTA)Incomer - 1(Main LT Panel): 100A TPN TM Based MCCB with O/L, S/C & inbuilt E/F 36kA - 1 no. - 1 No. Suitable for 1 runs 95 Sqmm Cable Termination.R Y B, on, off, trip indication lamp - 1 set.Digital Ameter and Voltmeter - 1 set.SPD type-II within Panel, Min. 36KA, FP - 1 Nos.Multi Function Meter with CT RS 485 port.- 1 Nos.C.T. 100/5A, CLASS 1.0, 15VA- 1 set.Incomer - 2(DG Set): 100A TPN TM Based MCCB with O/L, S/C & inbuilt E/F 36kA - 1 no. - 1 No. Suitable for 1 runs 95 Sqmm Cable Termination.R Y B, on, off, trip indication lamp - 1 set.Digital Ameter and Voltmeter - 1 set.SPD type-II within Panel, Min. 36KA, FP - 1 Nos.Multi Function Meter with CT RS 485 port.- 1 Nos.C.T. 100/5A, CLASS 1.0, 15VA- 1 set.Auto Transfer Switch(ATS) for both incomer connectionBusbar:-1100A FP AL. busbar (25kA)Outgoing from Bus-1:A. 63A FP MCB, 10kA - 5 nos.B. 40A FP MCB, 10kA - 2 nos.C. 32A FP MCB, 10kA - 1 no.
144External Lighting Panel - Outdoor Lighting (Outdoor Type - IP55 With Canopy) - PTTA40A FP MCB+RCCB (10kA) - 2 No.R Y B, on, off, trip indication lamp - 2 set.Digital Ameter and Voltmeter -21 set.SPD type-II - 2 Nos.Multi Function Meter with CT RS 485 port.- 2 Nos.C.T. 40/5A, CLASS 1.0, 10VA- 2 set.Busbar:-163A TPN Tinned CU busbar (10kA)Outgoing from Bus-1:A. 20A FP MCB, 10kA - 8 nos.
145High Mast & Facade DB - Outdoor Lighting with Astronomical Timer(Outdoor Type - IP55 With Canopy) - PTTA40A FP MCB+RCCB (10kA) - 2 No.R Y B, on, off, trip indication lamp - 2 set.Digital Ameter and Voltmeter -21 set.SPD type-II - 2 Nos.Multi Function Meter with CT RS 485 port.- 2 Nos.C.T. 40/5A, CLASS 1.0, 10VA- 2 set.Busbar:-140A TPN Tinned CU busbar (10kA)Outgoing from Bus-1:A. 20A DP MCB, 10kA - 9 nos.
146Common Area Distribution Board (8 Way TPN)_Raw Power
147Common Area Distribution Board (8 Way TPN UPS DB)_Emergency Power
148UPS DB F Cable & Termination-: 0.0 0.0
149Supply, loading, transportation unloading at site, storages at site ,shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, outersheath FRLS, Aluminium/Copper conductor flat strip armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. a 3.5C x 300 Sqmm. AL 366.405 Mtr 2545.49 932680.26 b 3.5C x 185 Sqmm. AL 50.0 Mtr 1636.39 81819.5 c 3.5C x 95 Sqmm. AL 37.0 Mtr 868.83 32146.71 d 3.5C x 25 Sqmm. AL 158.0 Mtr 297.9 47068.2 e 4C x 16 Sqmm. AL 50.0 Mtr 236.31 11815.5 f 4C x 10 Sqmm. AL 134.0 Mtr 183.6 24602.4 g 4C x 6 Sqmm. CU 644.0 Mtr 626.6 403530.4 h 3C x 2.5 Sqmm. CU 195.6 Mtr 235.72 46106.83
150Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. a Upto 35 sq.mm (clamped with 1mm thick saddle) 432.4 Mtr 40.18 17373.83 b Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS Metre flat clamp) 10.0 Mtr 82.14 821.4 c Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS Metre flat clamp) 10.0 Mtr 102.68 1026.8 d Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS Metre flat clamp) 10.0 Mtr 165.18 1651.8
151Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a Upto 35 sq.mm 158.0 Mtr 33.04 5220.32 b Above 35 sq.mm and upto 95 sq. mm 37.0 Mtr 50.89 1882.93 c above 95 sqmm and upto 185 sqmm 50.0 Mtr 68.75 3437.5 d Above 185 sqmm and upto 400 sqmm 366.405 Mtr 119.64 43836.69
152Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium cable of 1.1 KV grade as required.mentioned size cable. a 3.5C x 300 Sqmm. AL 18.0 Nos 1066.96 19205.28 b 3.5C x 185 Sqmm. AL 2.0 Nos 781.25 1562.5 c 3.5C x 95 Sqmm. AL 2.0 Nos 525.0 1050.0 d 3.5C x 25 Sqmm. AL 8.0 Nos 279.46 2235.68 e 4C x 16 Sqmm. AL 4.0 Nos 275.89 1103.56 f 4C x 10 Sqmm. AL 20.0 Nos 240.18 4803.6 g 4C x 6 Sqmm. CU 82.0 Nos 240.18 19694.76 h 3C x 2.5 Sqmm. CU 30.0 Nos 229.46 6883.8
153Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. a 150 mm width X 50 mm depth X 1.6 mm thickness 0.0 Mtr 639.29 0.0 b 300 mm width X 60 mm depth X 1.6 mm thickness 90.0 Mtr 859.82 77383.8 c 450 mm width X 60 mm depth X 2 mm thickness 80.0 Mtr 1183.04 94643.2 d 750 mm width X 62.5 mm depth X 2 mm thickness 80.0 Mtr 2015.18 161214.4
154Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. a 150 mm width X 50 mm depth X 1.6 mm thickness 0.0 Nos 1133.93 0.0 b 300 mm width X 60 mm depth X 1.6 mm thickness 4.0 Nos 1653.57 6614.28 c 450 mm width X 60 mm depth X 2 mm thickness 5.0 Nos 2395.54 11977.7 d 750 mm width X 62.5 mm depth X 2 mm thickness 3.0 Nos 4319.64 12958.92
155Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. a 150 mm width X 50 mm depth X 1.6 mm thickness 0.0 Nos 1234.82 0.0 b 300 mm width X 60 mm depth X 1.6 mm thickness 2.0 Nos 1925.0 3850.0 c 450 mm width X 60 mm depth X 2 mm thickness 2.0 Nos 3393.75 6787.5 d 750 mm width X 62.5 mm depth X 2 mm thickness 2.0 Nos 5082.14 10164.28
156Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in existing trench as per IS 14930 part -II suitable for drawing underground cables. 63mm OD / 51mm ID
157Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in existing trench as per IS 14930 part -II suitable for drawing underground cables. 90mm OD / 76mm ID
158Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in existing trench as per IS 14930 part -II suitable for drawing underground cables. 120mm OD / 103mm ID H Misc. Items 0.0 0.0
159Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel,atleast 2mm thick,and vitreous enamelled white on both sides,and with inscription in single red colour on front side as required.
160Providing and fixing HT danger notice plate of 250 mm X 200 mm, made of mild steel,atleast 2mm thick,and vitreous enamelled white on both sides,and with inscription in single red colour on front side as required.
161Supply and fixing wooden framed covered with glass shock treatment chart printed on cloth in English ,Hindi & Local language.
162Supply and fixing suitable size wooden framed covered with glass for Main Panel SLD in electrical area as per IE rules fixed to wall as required.
163Supply and providing ISI marked electrical 1.1 kV grade 3 mm thick anti-skid rubber mat, 2 x 1 mtr as per IS:15652-2006 with up to date ammendment.
164Supply, installation, testing and commissioning of Standard First aid box complete with all accessories as required.
165Co2 type duly refilled 4.5 Kg & ready to use
1665kg DCP type Fire extinguisher
167Providing & fixing 4 nos. fire buckets with stand.
168Providing & fixing of 'No Smoking' and 'No Unauthorized Entry' signboards in English and Hindi, as per IPR- 1970.
169Preparation of Working drawings, approval from statutory authorities Total 112809670.0 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56612152
AUTHORITY Government Departments
TENDER VALUE 11.28 Crore
LAST DATE 19-08-2026
Authority
Authority Name Rourkela Smart City Limited
Work Description Tender for Design Construction Of Commercial Complex At Civil Township On Percentage Rate Basis.
Basic Detail
Tender No RSCL/1046/2026Dt.20/07/2026
Bidding Type Tender
Location
City Sundargarh
State Odisha
Key Dates
Publish Date 22 Jul 2026
Submission Date 19 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value 11.28 Crore
Tender Fee 11800
EMD 11.29 Lakhs
Exemption Available
Document List
0b7286bf-11a0-49a4-a5bb-68c2075e0c61.html
BOQ_601827.xls
DTCN.pdf
Merge1pdf.pdf
Mergestrpdf.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

0b7286bf-11a0-49a4-a5bb-68c2075e0c61.html

xls

BOQ_601827.xls

pdf

DTCN.pdf

pdf

Merge1pdf.pdf

pdf

Mergestrpdf.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders