Shipping Boards / Undertakings / PSU Closing in 17 days TDR #56606868

Bids Are invited for Purchase Of 6 Medical Equipments

Issued by Boards / Undertakings / PSU · Chennai, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Aug 2026
17 days left
EMD
41274
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
57

Project Description

Bids Are invited for Purchase Of 6 Medical Equipments Multipara Monitor - Multipara Monitor - Specificaitons - Type Of Monitor - Pre- Configured, Monitoring Parameters - Ecg ,Hr,Respiration Rate, Spo2, Pulse Rate Nibp,Temperature ,Ibp Length Of Time Of Full, Disclosure Of Patient Data In Hr - Greater Than Or Equal To 24, Length Of Time Of Trending In Hr - Greater Than Or Equal To 72, Number Of Leads Of Ecg - 5, Ecg Waveform Number Of Leads Display - 7, Respiration Rate Measurement Range 0- 150 Bpm Or More, Spo2 Measurement Range 70 - 100 Percentage, Systolic Blood Pressuremonitoring Range 40 - 250 Mmhg Or More, Diastolic Blood Pressure Monitoring Range 10 - 200 Mmhg Or More, Type Of Probe - Skin, Number Of Channels For Ibp - 2, Sensor Type - Na, Display Size In Inches - 12, Traces Of Display - Greater Than 10 And User Interface Of Display - Touchscreen And Rotary Knob. Refer Schedule A Of Tender Document. , Ecg Machine - Ecg Machine - Specifications - Description Of Function - Ecg Machine Is A Primary Equipment To Record Ecg Signal In Various Configurations, 12 Channels With Interpretation Is Required For Recording And Analysing The Waveforms With Special Software. It Should Have The Optional Facility To Measure And Display Waveforms Of 6 More Ec Of Back And Right Chest Region. General Requirements - 1. The Ecg Machine Should Be Able To Acquire All 12 Leads Simultaneously For Both Adult And Paediatric Patients. 2. Should Have Facility To Interpret 12 Lead And Derive 6 More Ecg Of Back - V7, V8 And 9 And Right Chest Region - V3r, V4r, V5r. 3. Must Be Able To Display All 12 Lead Ecg And Other Data On Bright Colour Backlit Lcd With Minimum 7 Inch Display. 4.Should Display All Ecg Waveforms Patient Information, Heart Rate, Qrs Mark, Error Message - 12 Lead Ecg Display With Print Preview - Qtc Interval - Hrv Analysis, Recording Speed Change Option. 5. Should Be Easy To Operate, Compact And Lightweight Not Exceeding 5 Kg Including Battery. 6. Should Have Alpha-Numeric Keyboard For Patient Data Entry. Refer Schedule A Of Tender Document. , Bio Safety Cabinet - Bio Safety Cabinet - Specifications- 1. Class I Is The Most Basic Bio-Safety Cabinet That Provide Protection To The Environment And The Laboratory Personnel. 2. It Does Not However Provide Protection To The Product As The Un-Sterilised Room Air Is Drawn Over The Work Surface. 3. Class I Bio-Safety Cabinets Are Typically Used To Either Enclose Specific Equipment Like Centrifuge Or For Procedures Like Aerating Cultures That Might Potentially Generate Aerosols. 4. Bio-Safety Cabinets Of This Class Are Either Ducted -Connected To The Building Exhaust System- Or Unducted -Re-Circulating Filtered Exhaust Back Into The Laboratory. 5. In The Class I Bio-Safety Cabinet, The Room Air Is Drawn Inthrough The Opening That Also Allows The Entry Of The Operator Arm During Work. 6. The Air Inside The Cabinet Then Takes The Aerosol Particles That May Have Been Generated And Moves It Away From The Operator Toward The Hepa Filter. 7. The Air Moving Out Of The Cabinet I Thus, Sterilised Via The Hepa Filters Before Its Discharge To The Environment.8. In This Way, Cabinet Protect The Operator And The Environment From The Aerosol But Not The S Le. Refer Schedule A Of Tender Document. , Syringe Pump - Syringe Pump - Specifications- The Syringe Infusion Pump Provides Uniform Flow Of Fluid By Precisely Driving The Plunger Of A Syringe Down Its Barrel. It Provides Accurate And Continuous Flow Rate For Precise Delivery Of I.V. Medication In Critical Medical Care. I. Operational Requirements - L. The Syringe Pump Should Be Programmable, User Friendly, Safe To Use And Should Have Battery Backup And Comprehensive Alarm System. 2. Demonstration Of The Equipment Is A Must. Ii. Technical Specifications - 1 . Flow Rate Programmable From 0.1 To 300 Ml Per Hr Or More In Steps Of 0.1 Ml Per Hr With User Selectable Flow Set Rate Option. Save Last Infusion Rate Even When The Ac Power Is Switched Off. 2.Bolus Rate Should Be Programmable To 300 - 1200 Ml Per Hr Or More With Infused Volume Display. Reminder Audio After Every 0.5 Ml Delivered Bolus. Save Last Bolus Rate Even When The Ac Power Is Switched Off. 3.Display Of Drug Name With A Provision Of Memorizing Names By The Operator, 4.Keep Vein Open -Kvo Must Be Available1.0 Ml Per Hr Or Set Rate If Lower Than 1.0 Ml. User Should Have Choice To Disable Kvo Whenever Desired, Etc. Refer Schedule A Of Tender Document. , High Frequency Radio Surgery Unit - Rf - High Frequency Radio Surgery Unit -Rf, High Frequency Radio Surgery Unit -Rf Cautery, Small Cautery Machine. Specifications - Operating Frequency - 2 Mega Hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 X 300 X 150 Mm, Weight - Lesser Than Or Equal To 7 Kg, Power Supply - 230 Volt, Output Power - 100 Watt. Refer Schedule A Of Tender Document. , Mobile Endoscopy Unit - Mobile Endoscopy Unit - Mobile Endoscopy Unit-Portable Endoscopy Unit. Specification - Integrated Camera-Led Light Source - 1. 1-3 Inch Lcd Image Sensor, 2. 19 Mm Endocarpler, 3. Hi-Portable Led Light Source, 4. Light Weigh Camera Head With Auto Iris Aperture And Osd, 5. Adjustable Led Brightness -Off-Mid-High Display -1. 12-13 Inch Display Size 2. Resolution- 1024 X768p- 60 Hz 3. Lcd Menu -Brightness, Sharpness, Contrast, Gamma. 4. Composite Video 5. Osd Function With Key Pad 6.Portable Carry Case With Safety Lock. Refer Schedule A Of Tender Document.

BOQ

Sl. No. Item TitleItem Description
1MULTIPARA MONITORMULTIPARA MONITOR - Specificaitons - Type of Monitor - Pre- Configured, Monitoring Parameters - ECG ,HR,Respiration Rate, SpO2, Pulse Rate NIBP,Temperature ,IBP Length of time of full, Disclosure of patient data in hr - Greater than or equal to 24, Length of time of trending in hr - Greater than or equal to 72, Number of leads of ECG - 5, ECG Waveform number of leads display - 7, Respiration rate measurement range 0- 150 bpm or more, SPO2 measurement range 70 - 100 percentage, Systolic Blood pressuremonitoring range 40 - 250 mmHg or more, Diastolic Blood pressure monitoring range 10 - 200 mmHg or more, Type of probe - Skin, Number of channels for IBP - 2, Sensor type - NA, Display Size in inches - 12, Traces of display - Greater than 10 and User Interface of display - Touchscreen and Rotary knob. Refer Schedule A of Tender document.
2ECG MACHINEECG MACHINE - Specifications - Description of function - ECG Machine is a primary equipment to record ECG signal in various configurations, 12 channels with interpretation is required for recording and analysing the waveforms with special software. It should have the optional facility to measure and display waveforms of 6 more EC of back and right chest region. General requirements - 1. The ECG machine should be able to acquire all 12 leads simultaneously for both adult and paediatric patients. 2. Should have facility to interpret 12 lead and derive 6 more ECG of back - V7, V8 and 9 and right chest region - V3R, V4R, V5R. 3. Must be able to display all 12 lead ECG and other data on bright colour backlit LCD with minimum 7 inch display. 4.Should display all ECG waveforms patient information, heart rate, QRS mark, error message - 12 lead ECG display with Print Preview - QTc interval - HRV analysis, recording speed change option. 5. Should be easy to operate, compact and lightweight not exceeding 5 kg including battery. 6. Should have alpha-numeric keyboard for patient data entry. Refer Schedule A of Tender document.
3BIO SAFETY CABINETBIO SAFETY CABINET - Specifications- 1. Class I is the most basic bio-safety cabinet that provide protection to the environment and the laboratory personnel. 2. It does not however provide protection to the product as the un-sterilised room air is drawn over the work surface. 3. Class I bio-safety cabinets are typically used to either enclose specific equipment like centrifuge or for procedures like aerating cultures that might potentially generate aerosols. 4. Bio-safety cabinets of this class are either ducted -connected to the building exhaust system- or unducted -re-circulating filtered exhaust back into the laboratory. 5. In the Class I bio-safety cabinet, the room air is drawn inthrough the opening that also allows the entry of the operator arm during work. 6. The air inside the cabinet then takes the aerosol particles that may have been generated and moves it away from the operator toward the HEPA filter. 7. The air moving out of the cabinet i thus, sterilised via the HEPA filters before its discharge to the environment.8. In this way, cabinet protect the operator and the environment from the aerosol but not the sample. Refer Schedule A of Tender document.
4SYRINGE PUMPSYRINGE PUMP - Specifications- The Syringe Infusion Pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel. It provides accurate and continuous flow rate for precise delivery of I.V. medication in critical medical care. I. Operational Requirements - l. The syringe pump should be programmable, user friendly, safe to use and should Have battery backup and comprehensive alarm system. 2. Demonstration of the equipment is a must. II. Technical Specifications - 1 . Flow rate programmable from 0.1 to 300 ml per hr or more in steps of 0.1 ml per hr with User selectable flow set rate option. SAVE last infusion rate even when the AC power is switched OFF. 2.Bolus rate should be programmable to 300 - 1200 ml per hr or more with infused volume display. Reminder audio after every 0.5 ml delivered bolus. SAVE last Bolus rate even when the AC power is switched OFF. 3.Display of Drug Name with a provision of memorizing names by the operator, 4.Keep Vein Open -KVO must be available1.0 ml per hr or set rate if lower than 1.0 ml. User should have choice to disable KVO whenever desired, etc. Refer Schedule A of Tender document.
5HIGH FREQUENCY RADIO SURGERY UNIT - RFHIGH FREQUENCY RADIO SURGERY UNIT -RF, HIGH FREQUENCY RADIO SURGERY UNIT -RF CAUTERY, SMALL CAUTERY MACHINE. Specifications - Operating frequency - 2 Mega hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 x 300 x 150 mm, Weight - Lesser than or equal to 7 kg, Power supply - 230 Volt, Output power - 100 watt. Refer Schedule A of Tender document.
6MOBILE ENDOSCOPY UNITMOBILE ENDOSCOPY UNIT - MOBILE ENDOSCOPY UNIT-Portable Endoscopy Unit. Specification - Integrated Camera-LED light source - 1. 1-3 inch LCD image sensor, 2. 19 mm endocarpler, 3. Hi-portable LED light source, 4. Light weigh camera head with auto iris aperture and OSD, 5. Adjustable LED brightness -off-mid-high Display -1. 12-13 inch Display size 2. Resolution- 1024 x768p- 60 Hz 3. LCD menu -brightness, sharpness, contrast, Gamma. 4. Composite video 5. OSD function with key pad 6.Portable carry case with safety lock. Refer Schedule A of Tender document.

AI Tender Summary

OUR REF NO 56606868
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 12-08-2026
Authority
Authority Name Chennai Port Trust
Work Description Bids Are invited for Purchase Of 6 Medical Equipments Multipara Monitor - Multipara Monitor - Specificaitons - Type Of Monitor - Pre- Configured, Monitoring Parameters - Ecg ,Hr,Respiration Rate, Spo2, Pulse Rate Nibp,Temperature ,Ibp Length Of Time Of Full, Disclosure Of Patient Data In Hr - Greater Than Or Equal To 24, Length Of Time Of Trending In Hr - Greater Than Or Equal To 72, Number Of Leads Of Ecg - 5, Ecg Waveform Number Of Leads Display - 7, Respiration Rate Measurement Range 0- 150 Bpm Or More, Spo2 Measurement Range 70 - 100 Percentage, Systolic Blood Pressuremonitoring Range 40 - 250 Mmhg Or More, Diastolic Blood Pressure Monitoring Range 10 - 200 Mmhg Or More, Type Of Probe - Skin, Number Of Channels For Ibp - 2, Sensor Type - Na, Display Size In Inches - 12, Traces Of Display - Greater Than 10 And User Interface Of Display - Touchscreen And Rotary Knob. Refer Schedule A Of Tender Document. , Ecg Machine - Ecg Machine - Specifications - Description Of Function - Ecg Machine Is A Primary Equipment To Record Ecg Signal In Various Configurations, 12 Channels With Interpretation Is Required For Recording And Analysing The Waveforms With Special Software. It Should Have The Optional Facility To Measure And Display Waveforms Of 6 More Ec Of Back And Right Chest Region. General Requirements - 1. The Ecg Machine Should Be Able To Acquire All 12 Leads Simultaneously For Both Adult And Paediatric Patients. 2. Should Have Facility To Interpret 12 Lead And Derive 6 More Ecg Of Back - V7, V8 And 9 And Right Chest Region - V3r, V4r, V5r. 3. Must Be Able To Display All 12 Lead Ecg And Other Data On Bright Colour Backlit Lcd With Minimum 7 Inch Display. 4.Should Display All Ecg Waveforms Patient Information, Heart Rate, Qrs Mark, Error Message - 12 Lead Ecg Display With Print Preview - Qtc Interval - Hrv Analysis, Recording Speed Change Option. 5. Should Be Easy To Operate, Compact And Lightweight Not Exceeding 5 Kg Including Battery. 6. Should Have Alpha-Numeric Keyboard For Patient Data Entry. Refer Schedule A Of Tender Document. , Bio Safety Cabinet - Bio Safety Cabinet - Specifications- 1. Class I Is The Most Basic Bio-Safety Cabinet That Provide Protection To The Environment And The Laboratory Personnel. 2. It Does Not However Provide Protection To The Product As The Un-Sterilised Room Air Is Drawn Over The Work Surface. 3. Class I Bio-Safety Cabinets Are Typically Used To Either Enclose Specific Equipment Like Centrifuge Or For Procedures Like Aerating Cultures That Might Potentially Generate Aerosols. 4. Bio-Safety Cabinets Of This Class Are Either Ducted -Connected To The Building Exhaust System- Or Unducted -Re-Circulating Filtered Exhaust Back Into The Laboratory. 5. In The Class I Bio-Safety Cabinet, The Room Air Is Drawn Inthrough The Opening That Also Allows The Entry Of The Operator Arm During Work. 6. The Air Inside The Cabinet Then Takes The Aerosol Particles That May Have Been Generated And Moves It Away From The Operator Toward The Hepa Filter. 7. The Air Moving Out Of The Cabinet I Thus, Sterilised Via The Hepa Filters Before Its Discharge To The Environment.8. In This Way, Cabinet Protect The Operator And The Environment From The Aerosol But Not The S Le. Refer Schedule A Of Tender Document. , Syringe Pump - Syringe Pump - Specifications- The Syringe Infusion Pump Provides Uniform Flow Of Fluid By Precisely Driving The Plunger Of A Syringe Down Its Barrel. It Provides Accurate And Continuous Flow Rate For Precise Delivery Of I.V. Medication In Critical Medical Care. I. Operational Requirements - L. The Syringe Pump Should Be Programmable, User Friendly, Safe To Use And Should Have Battery Backup And Comprehensive Alarm System. 2. Demonstration Of The Equipment Is A Must. Ii. Technical Specifications - 1 . Flow Rate Programmable From 0.1 To 300 Ml Per Hr Or More In Steps Of 0.1 Ml Per Hr With User Selectable Flow Set Rate Option. Save Last Infusion Rate Even When The Ac Power Is Switched Off. 2.Bolus Rate Should Be Programmable To 300 - 1200 Ml Per Hr Or More With Infused Volume Display. Reminder Audio After Every 0.5 Ml Delivered Bolus. Save Last Bolus Rate Even When The Ac Power Is Switched Off. 3.Display Of Drug Name With A Provision Of Memorizing Names By The Operator, 4.Keep Vein Open -Kvo Must Be Available1.0 Ml Per Hr Or Set Rate If Lower Than 1.0 Ml. User Should Have Choice To Disable Kvo Whenever Desired, Etc. Refer Schedule A Of Tender Document. , High Frequency Radio Surgery Unit - Rf - High Frequency Radio Surgery Unit -Rf, High Frequency Radio Surgery Unit -Rf Cautery, Small Cautery Machine. Specifications - Operating Frequency - 2 Mega Hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 X 300 X 150 Mm, Weight - Lesser Than Or Equal To 7 Kg, Power Supply - 230 Volt, Output Power - 100 Watt. Refer Schedule A Of Tender Document. , Mobile Endoscopy Unit - Mobile Endoscopy Unit - Mobile Endoscopy Unit-Portable Endoscopy Unit. Specification - Integrated Camera-Led Light Source - 1. 1-3 Inch Lcd Image Sensor, 2. 19 Mm Endocarpler, 3. Hi-Portable Led Light Source, 4. Light Weigh Camera Head With Auto Iris Aperture And Osd, 5. Adjustable Led Brightness -Off-Mid-High Display -1. 12-13 Inch Display Size 2. Resolution- 1024 X768p- 60 Hz 3. Lcd Menu -Brightness, Sharpness, Contrast, Gamma. 4. Composite Video 5. Osd Function With Key Pad 6.Portable Carry Case With Safety Lock. Refer Schedule A Of Tender Document.
Basic Detail
Tender No GEM/2026/B/7821829
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 22 Jul 2026
Submission Date 12 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 41274
Exemption Not Available
Document List
b3ba9c12-ef1f-4607-827e-f67033f085a5.pdf
9646503_Boq_1.xlsx
DOC_1752_b3689c2b-f10d-4938-95921784719595779_chptamm2.pdf
spec_2026-07-22-16-41-01_634203bba1159ab697250d04448ae275.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

b3ba9c12-ef1f-4607-827e-f67033f085a5.pdf

xlsx

9646503_Boq_1.xlsx

pdf

DOC_1752_b3689c2b-f10d-4938-95921784719595779_chptamm2.pdf

pdf

spec_2026-07-22-16-41-01_634203bba1159ab697250d04448ae275.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders