Tender For special Repair Of Ahu For Certain Ac Plant At Various Locations Under Ge(U) P&M Delhi Cantt-10
Tender Value
1.49 Crore
Estimated cost
Bid Submission
17 Aug 2026
21 days left
EMD
2.24 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Ahu For Certain Ac Plant At Various Locations Under Ge(U) P&M Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and taking down old/unserviceable/rusted ,Supply/Return /Fresh Air GI Duct of any size/shape/dia with insulation from walls, roofs, ceiling for renewal complete Including Ducting Supports , rubber gaskets, elbows, vanes, & supports as per (IS 655) etc, made of 0.63 mm thick sheet complete all as specified and directed. |
| 2 | -Ditto- all as per item No 1.00 here-in-before but 0.80 mm thick sheet |
| 3 | Material & Labour for Supply, fabrication ,Installation, Balancing and Commissioning of fabricated 0.63 mm thick, GSS/PGI sheet metal rectangular ducts/ elbows as per site requirement with supports as per IS 655-2010 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as site requirements complete all as specified and directed. |
| 4 | -Ditto- all as per item No. 3.00 here-in-before but 0.80 mm thick sheet |
| 5 | Material & Labour for Supply and installation in renewal of thermal insulation material for non-exposed Ducts with closed cell class o nitride rubber elastomeric insulation of density 40-60 Kg/m3 thermal conductivity of 0.033-0.038 W/mk and µ>=7000 (k-flex st) to be applied on ducts using manufacturers recommended rubber based adhesive as per the approved specification the material shallbe from global approved & UL approved for new ducts as required at site 25mm thick complete all as specified and directed. |
| 6 | Dismantling old/Unserviceable/rusted Supply/Return Air Diffuser/Dampers/side Grilles/VCD , of any size any shape complete all as specified and directed. |
| 7 | Supply and fixing of powder coated extruded aluminum rectangular air diffusers of required size with volume control complete with black anodized extruded aluminum VCD, nuts, bolts, screws etc. complete all as specified and directed. |
| 8 | S&F of powder coated extruded aluminum return air diffuser of required size without volume control diffuse, nuts, bolts, screws etc. complete all as specified and directed. |
| 9 | Supply & fixing in renewal of powder coated extruded aluminum supply & return grilles complete with nuts, bolts, screws etc. to make the system complete, as required at site all as specified and directed. |
| 10 | M&L for Supply, installation, testing and commissioning in renewal of flexible fire retardant canvas connector cloth including removing of old one complete all as specified and directed. |
| 11 | Supply, installation, testing and commission of UL-555 motorized fire dampers complete with smoke detector/ thermister linkage etc in supply Air/Return air Ducts and all control wiring and supply wiring as required for operation complete all as specified and directed. |
| 12 | Material & Labour in renewal for earthing with galvanized steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanized earth lead by means of bolts, nuts check nuts and washers of galvanized iron strip 32x6mm as earth lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including GI strip up to 7.5mtr and necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40 mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15cm thick including taking down old unserviceable one complete all as specified and directed. |
| 13 | Supply and fixing in renewal of earth continuity conductor or main earthing lead (GI strip extension) of size 32 X 6mm fixed to plinth or buried in ground or drawn in GI pipe or any other situation as indicated for loop earthing etc complete all as specified and directed. |
| 14 | Dismantling and taking down old/ Unserviceable 16000 CFM AHU after disconnecting all electrical and MS pipe transfering it to MES store.Note: All old dismantled items are property of MES and shall be deposited at MES store |
| 15 | Dismantling and taking down old/ Unserviceable 13000 CFM AHU after disconnecting all electrical and MS pipe transfering it to MES store.Note: All old dismantled items are property of MES and shall be deposited at MES store |
| 16 | Dismantling and taking down old/ Unserviceable 4000 CFM AHU after disconnecting all electrical and MS pipe transfering it to MES store.Note: All old dismantled items are property of MES and shall be deposited at MES store |
| 17 | Dismantling and taking down old/ Unserviceable 18000 CFM AHU after disconnecting all electrical and MS pipe transfering it to MES store.Note: All old dismantled items are property of MES and shall be deposited at MES store |
| 18 | Dismantling and taking down old/ Unserviceable 6000 CFM AHU after disconnecting all electrical and MS pipe transfering it to MES store.Note: All old dismantled items are property of MES and shall be deposited at MES store |
| 19 | Supplying, installing, testing and commissioning of 25 mm thick double skin construction Floor Mounted Air Handling Unit with 4 rows deep Chilled water Coil and 2 rows deep Hot Water Coil and no. of fins per inch (FPI) For CHW Coil is 11/12 and for Hot water coil FPI is 8/10 and nominal capacity -16000CFM and 0.6mm pre coated GI outer skin & 0.6 mm Plan GI inner skin alongwith all fixing accessories, angle iron work for base frame and necessory PCC work, complete all as specified and directed by Engr-in-Charge and comprising of following:(a) EC fan section shall be equipped with a Single Inlet Centrifugal Impeller with High Efficiency Backward curved blades and external rotor EC (Electronically Commutated) motor, energy optimized for operation without spiral housing for high efficiency and favorable acoustic behavior. The high efficiency backward curved impeller made of welded aluminium sheet/ high performance composite material, with external rotor motor balanced together statically and dynamically according to DIN ISO 1940. The EC fan shallbe capable of being fitted in horizontal or vertical position in the AHU, depending on the application. |
| 20 | (b) Pre filter (MERV 8) in supply air stream. With efficiency 90 % down to 10 micron. (c) AHU with 4 row deep Chilled water coil and 2 row deep hot water coil (AHRI certified as per test standard ARI-410 & UL Certified for safety) with 0.15 mm Plain aluminium fins. GI construction end plates to be provided, 20 Gauge SS304 tray duly insulated with 13 mm closed cell nitrile insulation. Drain pipe dia shall be 50mm with U-trap of same size. (d) The minimum efficiency class of the motor shall be equivalent to IE5. The motor shall be Permanent magnet external rotor motor with integrated electronics and suitable for continuous operation. The speed of the motor shall be varied with an external 0-10V/ PWM control signal.The fan is totality shall be of most efficient type so that the power Consumption and noise level is minimal. The motor shall be minimum IP55 protection class. (e) Controller module with RS 485 port compatible with BMS, on board protocol following 1. EC fan operation status 2.Chilled water valve operation status 3. AHU Airflow (CFM) 4. AHU power consumption. Controller shall also have fire trip alarm to shut AHU in case of signal from fire panel. Please Enable Macros to View BoQ information |
| 21 | (b) Pre filter (MERV 8) in supply air stream. With efficiency 90 % down to 10 micron. (c) AHU with 4 row deep Chilled water coil and 2 row deep hot water coil (AHRI certified as per test standard ARI-410 & UL Certified for safety) with 0.15 mm Plain aluminium fins. GI construction end plates to be provided, 20 Gauge SS304 tray duly insulated with 13 mm closed cell nitrile insulation. Drain pipe dia shall be 50mm with U-trap of same size. (d) The minimum efficiency class of the motor shall be equivalent to IE5. The motor shall be Permanent magnet external rotor motor with integrated electronics and suitable for continuous operation. The speed of the motor shall be varied with an external 0-10V/ PWM control signal.The fan is totality shall be of most efficient type so that the power Consumption and noise level is minimal. The motor shall be minimum IP55 protection class. (e) Controller module with RS 485 port compatible with BMS, on board protocol following 1. EC fan operation status 2.Chilled water valve operation status 3. AHU Airflow (CFM) 4. AHU power consumption. Controller shall also have fire trip alarm to shut AHU in case of signal from fire panel. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysAug 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender