Tender For Repair/Replacement Of External Electric Supply , Lt Ug Cables, Oh Lines, Security Lights, Lt Poles And Other Misc E/M Works At Diber Fd Stn Auli
Tender Value
8.50 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
4 days left
EMD
42500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chamoli → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of External Electric Supply , Lt Ug Cables, Oh Lines, Security Lights, Lt Poles And Other Misc E/M Works At Diber Fd Stn Auli
BOQ
| Sl. No. | Item Description |
| 1 | Contract Details |
| 2 | S&F pin type porcelain vitreous white, brown or green insulator size 100mm high and 65mm dia, for working pressure 1100 volts grade incl one galvanised mild steel spindle, two galvanised iron washers and one nut complete all as specified and directed. |
| 3 | S&F shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75mm height and 90mm dia for working pressure 1100 volts, LT complete with insulator bolts, washers and nuts complete all as specified and directed. |
| 4 | M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. |
| 5 | M & L for supply, transporting, erecting truly in vertical position and fixing of steel tubular pole swaged, over all length 9 metres, type 410 – SP – 31 complete with mild steel base plate, pole cap, finial taper plug, MS bolts, nuts & washers, necessary excavation & earthwork in hard / dense soil, PCC sub base block as mass concrete of size 600 X 600 X 150 mm in cement concrete 1:4:8 Type D-2 in base of foundation, PCC foundation block of size 600 X 600 X 1500 mm in cement concrete 1:3:6 Type C-2, pole plinth of size 600 X 600 X 300 mm in cement concrete 1:2:4 Type B-1 including necessary form work as required at site and painting of pole with two coats of anti corrosive black bituminous paint through out internally and externally upto planting depth (embedded in concrete) and remaining portion of the pole painted two coats of aluminium paint over a coat of red oxide primer on complete exposed surface including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed. |
| 6 | Supply, laying, jointing and commissioning LT XLPE 1100 volts grade heavy duty cable PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes,induct, on pole and roads etc of following sizes :- (a) 16 Sqmm 4 core |
| 7 | All as per item no 6 above but for size of cable 16 Sqmm 2 core |
| 8 | All as per item no 6 above but for size of cable 10 Sqmm 2 core |
| 9 | Taking out unserviceable LT cable of any type and size from pole/wall/trenches by disconnecting electric connections for repair / replacement of cable complete all as specified and directed. |
| 10 | S&F plastic (moulded poly propeline) line phase saperators for separating 3/5 Nos of over head line conductors length 1200mm with 25mm with fly nuts and clamps suitable for 1100 volts grade LT electric lines of any size fixed with over head electric lines all as specified and directed. |
| 11 | M&L stringing and stretching (ACSR) conductor on LT over head line incl binding on insulator with aluminium binding wire or aluminium trap compelete all as specified of the following sizes :-(a) (Weasel) 6/1x2.59mm aluminium and 1x2.59 steel (b) Ferret (6/1 x 3.0 mm aluminium and 1 x3.0 mm steel) |
| 12 | M&L stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length fixed to pole with and including FI clamps 50 x 6 mm size bolt, nuts washers, GI steel stay rod 20 mm dia and 1800 mm long stay bow 400 x14mm, GI steel plate 300x300x6mm, two nos thimble loop insulator of size 90x140mm clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work as shown in electrical plate No. 1 of SSR part - I 2009 on page No 495 |
| 13 | Supply and laying in replacement GI steel tubing light grade (IS-1239) of dia 50 mm with all fittings in trenches/under roads/along pole/wall for protection of Cable/GI wire/ GI strip etc all as specified and directed.( Note : Exc and earth work shall be measured and paid separetely) |
| 14 | Supply and laying in replacement GI steel tubing light grade (IS-1239) of dia 25 mm with all fittings in trenches/under roads/along pole/wall for protection of Cable/GI wire/ GI strip etc all as specified and directed.( Note : Exc and earth work shall be measured and paid separetely) |
| 15 | M&L for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in in electrical plate No 5 on page 19-49 of MES schedule 1991 Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 20 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 25mm dia light grade up to 7.5m from complete all as specified ,indicated on electrical plate No 5 and as directed incl testing on completion.NOTE: ( i ) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 25mm/40mmdia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 16 | -do- all as per sl No. 15 above but GI earth strip 32x6mm by means of nut, bolts, check nuts, washers of GI steel 40mm dia light grade 1.5 mtr long watering pipe with one socket and plug on top and 40mm dia GI pipe light grade for protection of earth strip upto a length of 7.5 mtr incl PCC chamber RCC cover with lifting handle, layer of charcoal & salt including necessary excavation & earth work all as shown in EP No 5 connected to earthing test point all as specified and directed. |
| 17 | M & L for one coat of aluminium paint of approved quality incl preparation of existing old painted surface of steel tubular pole 9 mtr long complete including flat iron clamps, bracing , cross arms etc and with 05 nos band / strips with black and yellow paint alternately incl numbering of poles with white synthetic enamel paint over a circular painted base complete all as specified and directed. |
| 18 | Tightening/restringing existing loose/broken conductor ACSR/GI any type or size incl binding with suitable binding wire and jointing jumpers as required at site all as specified and directed. |
| 19 | Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and not exc 1.5 m in depth for post holes, laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed. |
| 20 | Returning filling in incl spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed. |
| 21 | Removing excavated material to a distance not exc 15 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 22 | M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches all as specified and directed. |
| 23 | M&L for providing old size sub class 'B' bricks laid perpendicular to the cable abutting each other all as specified and directed by the Engineer-in-charge. |
| 24 | Dismantling of cross arms, fabricated from Ms structural section of any type and size, duly bolted from existing position and keeping at side for repair/replacement as directed. |
| 25 | Dismantling of existing stay assembly any type/size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed. |
| 26 | Dismantling/taking out old ACSR/copper conductor/GI earth wire any size from existing over head lines incl disconnection all as specified and directed. |
| 27 | Dismantling/taking out insulator of any size/type from existing electric overhead lines all as specified and directed. |
| 28 | Cutting/ Trimming of trees/branches from LT overhead lines /pole of any width/ girth clearing 2 meter horizontal 7.2 meter vertical distance from both side of conductor including collection and shifting the retrieved timber from site at a place as directed by Engr-in-charge complete all as specified and directed. Note :- (i) Each span have a distance 40mtr approximately (ii) All cutting branches of trees shall be thrown away/ burnt at approximate 200 to 500 mtr away as directed. |
| 29 | M&L for danger notice plate of 1.6 mm thick mild steel sheet, vitrous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20 x 15 cm complete incl taking down old danger plates all as directed at site. |
| 30 | M&L stringing and stretching Galvanised steel wire 4 mm dia for guard wire of LT over head line incl binding on insulator with aluminium binding wire or aluminium trap compelete all as specified and directed. |
| 31 | S&F synthetic insulating mat near electric installations of size 2m x lmX 3mm as specified and directed. |
| 32 | S & F MCCB 415 Volts, 4 pole, 16 KA, 100 Ampere complete all as specified and directed |
| 33 | S & F MCCB 415 Volts, 4 pole, 16 KA, 125 Ampere complete all as specified and directed |
| 34 | S & F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed |
| 35 | S & F MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed |
| 36 | Supply and fix aluminium lugs of size 150 mm sqmm complete all as specified and directed . |
| 37 | Supply and fix aluminium lugs of size 95 mm sqmm complete all as specified and directed . |
| 38 | Supply, fixing and testing LT cable jointing kit straight through suitable for cable PVC /XLPE insulated armored heavy duty aluminum conductor 1100V grade LT cable of size 3.5/4 core 16 to 50 sqmm complete all as directed. |
| 39 | Supply, fixing and testing LT cable jointing kit straight through suitable for cable PVC /XLPE insulated armored heavy duty aluminum conductor 1100V grade LT cable of size 3.5 core 35 to 70 sqmm complete all as directed. |
| 40 | Taking out old U/S service connection cable for replacement including S&F service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor, 16 Sqmm 2 core size, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 41 | Supply and install, testing off load type changeover switch four pole, AC 415 volts 50 HZ of capacity 100 Amps 4 pole with enclosure, side handle operated conforming to IS:13947 incl fixing on wall/panel complete all as directed. |
| 42 | S&F in repair/replacement of digital Voltmeter 0-500 Volts with selector switch and coil complete all as directed. |
| 43 | S&F in repair/replacement of digital Ampere meter 0-200 Amps with selector switch and coil complete all as directed. |
| 44 | M&L for notice board of size 50x20 cm and written as \\"OUT OF BOUND FOR ALL RANKS\\", made from 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures in signal red colour and fixed with MS clamps, bolt and nuts of approved size complete all as specified and directed. |
| 45 | M&L for notice board of size 50x20 cm and written as \\"NO ADMISSION\\", made from 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures in signal red colour and fixed with MS clamps, bolt and nuts of approved size complete all as specified and directed. |
| 46 | Supply & Fix in replacement for ELECTRIC SHOCK CHART (Electric shock & its management chart) of standard size 70x50 cm drawn on wooden/ cardboard frame of approved size complete all as specified and directed. |
| 47 | Supply & Fixing LED street light fitting 36/35 W pressure die cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver including GI bracket light grade 25/32mm and connecting the fitting to over head ACSR/junction box at the bottom of pole with using 1.50 Sqmm three core PVC insulated and unsheathed copper conductor cable complete all as specified and directed specified and directed. Make Havells, Bajaj, Crompton |
| 48 | Supply & Fixing LED street light fitting 70W pressure die cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver including GI bracket light grade 25/32mm and connecting the fitting to over head ACSR/junction box at the bottom of pole with using 1.50 Sqmm three core PVC insulated and unsheathed copper conductor cable complete all as specified and directed specified and directed. Make Havells, Bajaj, Crompton |
| 49 | Supply & Fixing LED Flood light fitting 100 W 230 V AC outdoor type pressure die cast aluminium IP66 luminaire with high power LED as light source and electronic driver with impact and corrosion resisant including clamp and GI bracket light grade and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 4sqmm core complete all as specified and directed . Make Havells, Bajaj, Crompton |
| 50 | Taking down old U/S junction box and Supply and fixing Junction Box made up of High quality thermoplastic polycarbonate enclosure with IP 65 degree of protection, weather proof, corrosion proof, dust proof, insulted and shock proof, fire retardant non toxic material with internally embedded gasket with 10 Amp MCB and 4 nos terminal, size 200x160x98 mm of make hensel or equivalent make of Sintex/ Universal complete all as specified and directed by Engineer-in-Charge. |
| 51 | Dismantling/ taking out street light/Flood light fitting any type/cap complete with bracket all as specified and directed |
| 52 | S & F in repair MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type in the MCB DB/junction box including taking down complete all as specified and directed. |
| 53 | S & F in repair MCB single pole and neutral, 240 volts, 32 Amp, rupturing capacity 10 KA, ‘C’ curve type in the MCB DB/junction box including taking down complete all as specified and directed. |
| 54 | Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed. |
| 55 | M & L for repair of old street light/security lights upto 60W capacity by replacing old U/S driver, LED plate or any other items as and when required on site and making it serviceable and fixing it on pole/wall after repair complete all as specified and directed |
| 56 | M&L for GI pipe light grade 25mm dia with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable complete all as specified and directed |
| 57 | Supply and fixing of LED Post top lantern 20W with IP 65 protection outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp and all accessories including light grade GI pipe of suitable length and wire required for connections & fixing complete all as directed. Make : Havells ,Philips, Crompton |
| 58 | S&F in repair service wire 1100 volts grade PVC insulated PVC sheathed cable weather proof multi stranded with aluminum conductor of size 10 sqmm 2 corecomplete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender