Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56605037

Tender For Repair/ Maintenance Of Lt & Ht Cables Joints And Repair/ Maintenance Of Voltage Stabilizer With Connected Items At Af Stn Nal.

Issued by Statutory Bodies & Commissions/Committees · Bikaner, Rajasthan
Tender Value
45 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
20 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Lt & Ht Cables Joints And Repair/ Maintenance Of Voltage Stabilizer With Connected Items At Af Stn Nal.

BOQ

Name of Work:- REPAIR/ MAINTENANCE OF LT & HT CABLES JOINTS AND REPAIR/ MAINTENANCE OF VOLTAGE STABILIZER WITH CONNECTED ITEMS AT AF STN NAL.
Sl. No. Item Description
1M&L for disconnecting from the transformer /panel board, cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core through in trench/existing UG duct including taking out existing cable
2All as above per item No 1.00 here-in-before but size 150 sqmm, 3.5 core.
3All as above per item No 1.00 here-in-before but size 120 sqmm, 3.5 core.
4All as above per item No 1.00 here-in-before but size 95 sqmm, 3.5 core.
5All as above per item No 1.00 here-in-before but size 70 sqmm, 3.5 core.
6All as above per item No 1.00 here-in-before but size 50 sqmm, 3.5 core.
7All as above per item No 1.00 here-in-before but size 35 sqmm, 3.5 core.
8All as above per item No 1.00 here-in-before but size 25 sqmm, 4 core.
9All as above per item No 1.00 here-in-before but size 16 sqmm, 4 core.
10All as above per item No 1.00 here-in-before but size 10 sqmm, 4 core.
11M&L for disconnecting from the transformer /panel board, cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 185 sq mm 3 core including taking out existing cable
12All as above per item No 11 here-in-before but size 95 sqmm, 3 core.
13S & F in repair outdoor type heat shrinkable end joint for HT cable with aluminium conductor 11000 volts grade size 95Sqmm/185 sqmm, 3 core including jointing, commissioning and testing complete all as specified & directed.
14S&F in repair straight through type heat shrinkable joint for HT cable with aluminium conductor 11 KV grade size 95 sqmm, 3 core including jointing, commissioning and testing complete all as specified & directed.
15S&F in repair outdoor type heat shrinkable end joint for LT cable with aluminium conductor 1100 volts grade size 185Sqmm/240 sqmm, 3.5 core including jointing, commissioning and testing complete all as specified & directed.
16All as above per item No 15 here-in-before but size 120Sqmm/150Sqmm, 3.5 core.
17All as above per item No 15 here-in-before but size 50Sqmm/70Sqmm/95Sqmm, 3.5 core.
18S&F in repair outdoor straight through type heat shrinkable joint for LT cable with aluminium conductor 1100 volts grade size 185Sqmm/240 sqmm, 3.5 core including jointing, commissioning and testing complete all as specified & directed.
19All as above per item No 18 here-in-before but size 120Sqmm/150Sqmm, 3.5 core.
20All as above per item No 18 here-in-before but size 50Sqmm/70Sqmm/95Sqmm, 3.5 core.
21Finding of fault to 11 KV UG cable with suitable fault locator equipment & pin point the fault in the faulty cable including necessary excavation and earth work for exposing the faulty portion of the UG cable complete all as specified and directed.
22Supply & Fixing aluminium lugs for cable of cross sectional area 120 to 185 Sqmm to complete all as specified and directed by Engineer-in-charge.
23Supply & Fixing aluminium lugs for cable of cross sectional area 50 to 95 Sqmm to complete all as specified and directed by Engineer-in-charge.
24Supply & Fixing aluminium lugs for cable of cross sectional area 10 to 35 Sqmm to complete all as specified and directed by Engineer-in-charge.
25Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer- in- Charge.
26Returning filling in Including spreading, levelling. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
27Removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
28Material and labour for tiba sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
29S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
30Supply and laying unreinforced precast concrete cable cover class HVP, type -I with peak of size 300mmx180mmx40mm laid in trenches over under ground cables complete all as specified and as directed.
31Material and labour for HT/LT cable route marker / HT/LT joint marker made out of Jodhpur stone of size 250 mm width x 100 mm depth x 900mm height size with top oval shaped, engraved with 'HT cable' duly painted with approved colour with writing letter for both side complete all as specified and directed by Engineer- in- Charge. Note: - (i) Route Marker shall be buried in ground up to a depth of 45cm below the natural Ground Level (ii) Rate quoted shall include the cost of necessary excavation and earth work.
32Supply and fixing GI tubing light grade 80 mm bore for cable protection including taking out rusted existing GI pipe with complete all as specified and directed.
33Supply and fixing GI tubing light grade 40 mm bore for cable protection including taking out rusted existing GI pipe with complete all as specified and directed.
34Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine or manually without damage nearby electric cable, water pipe line etc including inserting GI pipe of 80 mm dia all as specified and directed. Note :- GI Pipe will be measured and paid separately. Please Enable Macros to View BoQ information
35Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine or manually without damage nearby electric cable, water pipe line etc including inserting GI pipe of 80 mm dia all as specified and directed. Note :- GI Pipe will be measured and paid separately. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56605037
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Lt & Ht Cables Joints And Repair/ Maintenance Of Voltage Stabilizer With Connected Items At Af Stn Nal.
Basic Detail
Tender No C81676/e8
Bidding Type Tender
Location
City Bikaner
State Rajasthan
Key Dates
Publish Date 22 Jul 2026
Submission Date 12 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
1cd2fa49-a0f8-4f73-93cc-4dcb58da0baf.html
BOQ_873880.xls
Tenderdocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

1cd2fa49-a0f8-4f73-93cc-4dcb58da0baf.html

xls

BOQ_873880.xls

pdf

Tenderdocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders