Tender For maintenance of Various Colonies Under Nazul Account-Ii Dwarka Zone. Sh:- Running, Maintenance & Operation Of Lifts, Fire Detection System, Fire Fighting System, Fire & Clear Water Pumps, Iei, D.G. Sets And Other E/M Installations At Commun
Tender Overview
Project Description
Tender for maintenance of Various Colonies Under Nazul Account-Ii Dwarka Zone. Sh:- Running, Maintenance & Operation Of Lifts, Fire Detection System, Fire Fighting System, Fire & Clear Water Pumps, Iei, D.G. Sets And Other E/M Installations At Community Halls Of Sec-03 , Bindapur Pkt-Iii, Haf Pkt Sector-16B Dwarka.
BOQ
| Sl. No. | Item Description |
| 1 | Running,Maintenance and operation of IEI, Compound Light, D.G Set, Firefighting Pump set, fire alarm system, Clear water pump set, & lift at community hall sector 3 as per the inventory & terms and condition attached.i) operator-1 nos |
| 2 | ii) khallasi-1 nos |
| 3 | iii)wireman |
| 4 | Running,Maintenance and operation of IEI, Compound Light, D.G Set, Firefighting Pump set, Clear water pump set, & lift at community hall Bindapur pkt-III, Dwarka as per the inventory & terms and condition attached.i) operator-1 nos |
| 5 | ii) khallasi-1 nos |
| 6 | iii)wireman |
| 7 | Running,Maintenance and operation of IEI, Compound Light, D.G Set, Firefighting Pump set, fire alarm system,mechanical ventilation&liftwell pressurization system, Clear water pump set, & lift at community hall HAF pkt sector-16B as per the inventory & terms and condition attached.i) operator-1 nos |
| 8 | ii) khallasi-1 nos |
| 9 | iii)wireman |
| 10 | Supplying of 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 11 | Supplying of 4.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 12 | Supplying, of LED surface mounted Batten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KVwith Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C)Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 18- 22 Watt |
| 13 | Supplying and replacement 1200 mm sweep size ceeling fan i/c connection , testing etc as required |
| 14 | Supplying and replacement 300 mm sweep size exhaust fan i/c connection , testing etc as required |
| 15 | Replacement of 2.5/3.5 mfd fan condensor including connection and testing as required |
| 16 | Repair and rewinding of 1200/1400mm ceiling fan ( copper winding ) i/c varishing, testing and installation |
| 17 | Replacement of ball bearing of ceiling fans including fixing and testing etc |
| 18 | Replacement of ball bush of ceiling fans including fixing & testing etc |
| 19 | Servicing of split type type air conditioner i/c cleaning of air filter, fin s condensor, evaporator fan, drain cleaning & leakage check, gas level check, checking of electrical checking of electrical coponents, connection & testing etc complete as required. |
| 20 | refrigerant charging of window/split air conditioning i/c pressure check, complete gas filling, cooling check etc as required |
| 21 | Pcb repair of split air conditioning 2 ton capacity i/c connection, testing & etc |
| 22 | Supplying and fixing following way, horizontal typethree pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But withoutMCB/RCCB/Isolator). 8 way (4 + 24), Double door |
| 23 | Supplying 6 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KAbreaking capacity i/c connections, testing and commissioning etc. as required. |
| 24 | Supplying 6 A, to 32 A, ratings, DP MCB, \\"C\\" curve, 10 KAbreaking capacity i/c connections, testing and commissioning etc. as required. |
| 25 | Supplying and Replacement following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch |
| 26 | b) 3 pin 5/6 A socket outlet |
| 27 | c) 15/16 A switch |
| 28 | d) 6 pin 15/16 A socket outlet |
| 29 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.a) 5/6 amps switch |
| 30 | b) 3 pin 5/6 A socket outlet |
| 31 | c) 15/16 A switch |
| 32 | d) 6 pin 15/16 A socket outlet |
| 33 | Supplying and Replacement of LED Post top with IP 65 rating of 35 watt i/connections, testing and commissioning etc. as required. |
| 34 | Servicing of 62.5 KVA D.G. set (Kirloskar make) i/c S/R of following parts/accessories, cartage testing on load etc complete as reqd. i) Oil filter --- 1 No.ii) Diesel filter (pre-micro)--- 1 setiii) Air cleaner elements --- 1 No.iv) K-cool superplus- 50-50 premix ---- 10 ltr.v) K-oil premix --- 13ltr,vi) Labour charges for servicing, functioning and testing--- 1 jobvii) Radiator cleaning charges --- 1 job i/c removal & refixing Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender