Housing Urban and Rular Development Government Departments Closing in 2 days TDR #56604198

Tender For Work Of Supply And Installation Of Air Conditioning Plants In The Remaining Court Rooms And Rest Rooms Of Additional District Judge Of District Court Firozabad.

Issued by Government Departments · Agra, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Jul 2026
2 days left
EMD
6.05 Lakhs
Bank guarantee accepted
Document Fee
2714
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Work Of Supply And Installation Of Air Conditioning Plants In The Remaining Court Rooms And Rest Rooms Of Additional District Judge Of District Court Firozabad.

BOQ

Name of Work:- जनपद न्यायालय फिरोजाबाद के अवशेष अपर जिला न्यायाधीश के न्यायालयों कक्षों एवं विश्राम कक्षों में वातानुकूलन संयत्रों की आपूर्ति एवं स्थापना का कार्य।
Sl. No. Item Description
1A.C. WorkSupplying,Installation,Testing and Commissioning of 1.5 TR with 5 BEE 5 Star Rating Air Cooled Hi wall split type Air conditioners complete with Indoor unit ,Outdoor Unit, surface/concealedcopper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section upto 3 mtr ( IDU to ODU ) , copper powder cable upto 3.5 mtr ( IDU to ODU ) i/c drain pipe R-32/R-410/R-407 Green Refrigerant wireless Remote control suitable for working between 180-260 V with low & high voltage cutoff and 50hz,1 phase AC supply capable of performing cooling,dehumidification , air circulation of following capacity with Scroll/ rotary compressor. The system shall be able to deliever 100% of the rated capacity upto 42degree C. Min 5 year Original Equipment manufacture ( OEM) warranty both compressor and printed circuit Board ( PCB ). Must comply: Electrical cable IS 694 or 9968 temperature sensing control IS / international Electrotechnical Commission ( IEC ) 60730, hermetic compressor IS 10617 , heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per CPWD specifications ans IS: 1391 part II 2023. The system shall be able to operate upto 52 degree ( Outdoor ambient temperature ) Inverter Type - Cooling only Make- Carrier/Panasonic/Blue Star/L.G.
2Supplying,Installation,Testing and Commissioning of 2.0 TR with 5 BEE 5 Star Rating Air Cooled Hi wall split type Air conditioners complete with Indoor unit ,Outdoor Unit, surface /concealedcopper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section upto 3 mtr ( IDU to ODU ) , copper powder cable upto 3.5 mtr ( IDU to ODU ) i/c drain pipe R-32/R-410/R-407 Green Refrigerant wireless Remote control suitable for working between 180-260 V with low & high voltage cutoff and 50hz,1 phase AC supply capable of performing cooling,dehumidification , air circulation of following capacity with Scroll/ rotary compressor. The system shall be able to deliever 100% of the rated capacity upto 42degree C. Min 5 year Original Equipment manufacture ( OEM) warranty both compressor and printed circuit Board ( PCB ). Must comply: Electrical cable IS 694 or 9968 temperature sensing control IS / international Electrotechnical Commission ( IEC ) 60730, hermetic compressor IS 10617 , heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per CPWD specifications ans IS: 1391 part II 2023. The system shall be able to operate upto 52 degree ( Outdoor ambient temperature ) Inverter Type - Cooling only Make- Carrier/Panasonic/Blue Star/L.G.
3SITC of suction/discharge pipe line in split A.C unit upto 1/1.5 toncapacity including brazing,nitrile,rubber insulation 6 mm thick class\\"O\\" etc.complete 1/2\\"(12.70 mm) and 1/4\\" (6.40mm)
4SITC of suction/discharge pipe line in split A.C unit upto 2.0 toncapacity including brazing,nitrile,rubber insulation 6 mm thick class\\"O\\" etc.complete 3/8\\"(9.50 mm) and 5/8\\" (15.90mm)
5Supply of wall mounted copper wounded Voltage stablizer 4 KVA Capacity
6Supply of wall mounted copper wounded Voltage stablizer 5 KVA Capacity
7Supply and laying of heavy duty PVC plastic braided 20mm OD flexible pipe for condensed water with dipping accessories complete
8S/F of Inter connecting PVC insulated copper cable for A.C 2.5 Sq. mm 3 core .
9Fabrication of M.S stand for Outer unit of A.C with fixing on wall with all material & labour complete in all respect
10Supply & Fixing of Outdoor Cage for 1.5/2.0 Ton A/C
11Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
12S/F of 32 Amp. 3 way Heavy Duty Cadmium plated copper connector with end plate complete in all respect
13Supplying and Fixing of 4 Way (4 + 12), Double Door Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
14S&F of Surface /flush mounting 4 ways SPN D.B. with additional metal door without MCB complete in all respect.
15Supply and Fixing of 5A To 32A rating 240/415V, 10ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Single Pole in the existing MCB DB complete with connections, testing and commissioning etc, as required.
16Supply and Fixing of 5A To 32A rating 240/415V, 10ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Double Pole in the existing MCB DB complete with connections, testing and commissioning etc, as required.
17Supply and Fixing of 63 Amp 4 Pole and neutral MCB (10KA) C Curve in the existing MCB DB complete with connection, testing and commissioning etc, as required.
18Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
19Wiring for circuit/ submain wiring alongwith earth wire with the 2 x 6 Sq. mm + 1 x 6 Sq. mm. earth wire FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required.
20Supply and laying of 25 Sq. mm. 3-1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750 mm. Below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run sell be fixed on M.S. clamps etc. of suitable size or as directed by engineer incharge complete in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc.
21Supply and laying of 35 Sq. mm. 3-1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750 mm. Below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run sell be fixed on M.S. clamps etc. of suitable size or as directed by engineer incharge complete in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc.
22Supply and laying of 150 Sq. mm. 3-1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750 mm. Below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run sell be fixed on M.S. clamps etc. of suitable size or as directed by engineer incharge complete in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc.
23Supply and laying of 400 Sq. mm. 3-1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750 mm. Below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run sell be fixed on M.S. clamps etc. of suitable size or as directed by engineer incharge complete in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc.
24Supplying and making end termination with brass compression gland and aluminium lugs for 3 X 25 sq. mm (25mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
25Supplying and making end termination with brass compression gland and aluminium lugs for 3 X 35 sq. mm (28mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
26Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 150 sq. mm (50mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
27Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 400 sq. mm (82mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
28SITC of LT panel vermin proof mounting , M.S. channel base with bottom and fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer in charge after proper sheet treatment process of sheet steel. The bus bar of panel shall be of electrical grade high conductive aluminium alloy of appropriate cross-section as per ratin the main bus bar shall run throughout the panel of rating as main incomer rating. The bus bar shall be supported by non hygroscopic SMC/DMC bus bar supports which shall be mounted on proper interval to ensure the bear the jerks of short circuit of 50kA for panels having ACB as incomer & 36kA for panels having MCCB incomers panel shall be constructed in fully segregated comparment design for each feeder as per 3b construction fonnat the panel shall be completed in all respect as per IS: 8623 part-2&3 . There shall be seprated metering compartment for incommer metering and outgoing metering.All incommer feeders shall be provided with multifunctioning metering along with phase indicating lights and other associated components such as CT, control MCB terminal block etc. and all outgoing feeders 100A and above shall be provided with 3 phase ammeter along with phase indicating lights and other associated components such instruments shall be digital type and indicating lights shall be LED type. wiring shall be done from 1100V grid PVC insulated copper flexible wire. All ACB shall be electrically operated draw out type with all MCCB shall be thermal magnetic/microprocessor with O/L & S/C protection along with required spreaders & extended rotary handle with pad locking facility of Breaking capacity (ICU/ICS) 36KA or more all MCB shall be thermal 10KA 'C' Curve cubicle type switch board shall be category A and B only. Incoming: 400 Amp. MCCB 1 No., Outgoing: 200 Amp. MCCB-2 Nos.,100 Amp. MCCB-1No. & 63 Amp. MCCB-1 No.
29SITC of LT panel vermin proof mounting , M.S. channel base with bottom and fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer in charge after proper sheet treatment process of sheet steel. The bus bar of panel shall be of electrical grade high conductive aluminium alloy of appropriate cross-section as per ratin the main bus bar shall run throughout the panel of rating as main incomer rating. The bus bar shall be supported by non hygroscopic SMC/DMC bus bar supports which shall be mounted on proper interval to ensure the bear the jerks of short circuit of 50kA for panels having ACB as incomer & 36kA for panels having MCCB incomers panel shall be constructed in fully segregated comparment design for each feeder as per 3b construction fonnat the panel shall be completed in all respect as per IS: 8623 part-2&3 . There shall be seprated metering compartment for incommer metering and outgoing metering. All incommer feeders shall be provided with multifunctioning metering along with phase indicating lights and other associated components such as CT, control MCB terminal block etc. and all outgoing feeders 100A and above shall be provided with 3 phase ammeter along with phase indicating lights and other associated components such instruments shall be digital type and indicating lights shall be LED type. wiring shall be done from 1100V grid PVC insulated copper flexible wire. All ACB shall be electrically operated draw out type with all MCCB shall be thermal magnetic/microprocessor with O/L & S/C protection along with required spreaders & extended rotary handle with pad locking facility of Breaking capacity (ICU/ICS) 36KA or more all MCB shall be thermal 10KA 'C' Curve cubicle type switch board shall be category A and B only. Incoming: 200 Amp. MCCB 1 No., Outgoing: - 63 Amp. MCCB-3Nos.
30Earthing with GI Earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/coal and salt as required
31Providing and Fixing 25 mm x 5 mm G.I. strip at 0.50 mtr below ground as strip earth electroe, including connection /terminating with G.I. nut, bolt, spring, washer etc. as required .(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
32Providing, laying and fixing 100 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
33S/L of 120 mm dia (OD-120 mm & ID-103 mm nominal) ISI marked along with all accessories like socket, bend, couplers etc. confirming to IS 14930, Part II complete with fitting and cutting , jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trech but excluding sand cushioning and protective covering etc. complete as required.
34Construction of one Panel Room of size (5 Mtr. x 4 Mtr. x 3 Mtr.) DSR factor -0.735 x ( 109/107)=0.7487
35Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
36L/C Cutting / moiling of the road for cable passing.
37Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
38Supply and fixing of Shock Treatment Chart (Prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work
39Supply and Fixing of Rewireable Porcelin Fuse Unit Triple Pole with neutral link 63 Amp. 415V AC, Make-Havells. HSN Code-8537
40Supply and Fixing of Heavy Duty Double Break Fuse Switches-HBC Fuse Type 200 Amp. 415V AC, Make-Havells. HSN Code-8537
41Supply and Fixing of Heavy Duty Double Break Fuse Switches-HBC Fuse Type 400 Amp. 415V AC, Make-Havells. HSN Code-8537,
42Wiring for light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
43Wiring for fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
44Wiring for exhaust fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
45Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 Pin 5/6 A modular socket outlet and 5/6 A Modular switch, connection etc. as required.
46Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 Pin 5/6 & 15/16 A modular socket outlet and 15/16 A Modular switch, connection etc. as required.
47Installation of exhaust fan up to 450 mm. sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
48Supply, Installation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
49Wiring for circuit/ submain wiring along with earth wire with the 2 x 1.5 Sq. mm. + 1 x 1.5 Sq. mm earth wire earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required.
50Wiring for circuit/ submain wiring along with earth wire 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
51Supply of fresh air Fan 300 mm. Make-Crompton and equivalent.
52Supply and Fixing of 16 SWG M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect.
53LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED 18- 22 Watt surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per equirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Note - 1- Rates are inclusive of all taxes but excluding GST which shall be paid extra as applicable 2- Labour cess @ 1% will be deducted from contractor's bill at the time of payment Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56604198
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 28-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Work Of Supply And Installation Of Air Conditioning Plants In The Remaining Court Rooms And Rest Rooms Of Additional District Judge Of District Court Firozabad.
Basic Detail
Tender No 676/6WE(Agra)-E/M Circle agra Dt.09.07.2026
Bidding Type Tender
Location
City Agra
State Uttar Pradesh
Key Dates
Publish Date 22 Jul 2026
Submission Date 28 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 2714
EMD 6.05 Lakhs
Exemption Not Available
Document List
08507983-4452-4b5a-bf67-7aae9b2731c3.html
BOQ_2199526.xls
T2Sfirozac2627f.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

08507983-4452-4b5a-bf67-7aae9b2731c3.html

xls

BOQ_2199526.xls

pdf

T2Sfirozac2627f.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender