Tender For Providing H.T. L.T. & Street Light (Composite) Power Network System On Road No. 10 Infront Plot No. C-1 To C-6 & B-7 To B-8 Sector 14 At I.A. Jagdishpur Distt. Amethi.
Tender Value
9.90 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
11 days left
EMD
23387
Bank guarantee accepted
Document Fee
1475
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing H.T. L.T. & Street Light (Composite) Power Network System On Road No. 10 Infront Plot No. C-1 To C-6 & B-7 To B-8 Sector 14 At I.A. Jagdishpur Distt. Amethi.
BOQ
| Sl. No. | Item Description |
| 1 | Supply&errection of Steel-tubular pole 410 SP-56,11 mtr. long 241 Kg. complete with 1/6 th of over all length of pole in cement concrete with one feet square/one feet dia cement ,concrete plinth around the pole above ground level. The foundations of underground will be of cement concrete in the ratio 1:2:4 .The stone ballast/brick-ballast used will be 1.25 cm (1/2x1) size with the stone pad 30x30x7.5 cm at the base, with MS pole Cap including all T&P, men & material for proper completion of work as per direction of Engineer in charge rate as per SIDC Sch. 02.07 |
| 2 | Supply/Fixing 11 KV ordinary pole fittings inculding all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. 03(a) |
| 3 | Supply & fixxing of 11 KV Originating/terminating pole fittings including all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. 03.02(v) |
| 4 | Supply&errection of double pole structure 410 SP-56,11 mtr. Long ST Pole complete with 1/6 th of over all length of pole in cement concrete with one feet square/one feet dia cement ,concrete plinth around the pole above ground level .The foundations of underground will be of cement concrete in the ratio 1:2:4 .The stone ballast/brick-ballast used will be 1.25 cm (1/2x1) size with the stone pad 30x30x7.5 cm at the base, including all T&P, men & material for proper completion of work rate as per SIDC Sch. 04(a) |
| 5 | S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect as per UPPWD Sch. No.701 |
| 6 | Supply&errection of Stay set of HT Line for ST pole with GI anchor plate(152x152x6mm) stay rod (16mm dia x 1.85 mtr.long) GI stay below (16 mm dia, thimble,double stay, tightener ,stay insulator ,clamps & stay wire (GS 7/13 .15 mm) including grouting in 1:4:8 ratio of cement concrete using course sand ,over brunt brick ballast. including all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 06(a) |
| 7 | Supply&errection of Stay of Gaurding channel for ST Pole with G.I Anchor plate (152x152x6mm) stay rod (16mm dia x 1.85 mtr.long) GI stay below (16 mm dia, thimble, double stay tightener, stay insulator, clamps & stay wire (GS 7/13 .15 mm) including grouting in 1:4:8 ratio of cement concrete using course sand, over brunt brick ballast. including all T&P, men & material for proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 06(b) |
| 8 | Supply,sagging,tensioning,jointing and binding of ACSR Dog conductor including cost of aluminium tape binding wire and jointing sleeves etc. complete in all respects including men & material,T&P proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 10.04 |
| 9 | Supply,sagging,tensioning,jointing and binding of G.I Wire no. 6 SWG on ST Pole complete in all respects including men & material,T&P proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 11.01 |
| 10 | Supply,sagging,tensioning,jointing and binding two parallel length of G.I Wire no. 6 SWG wire along the span and G.I 6 SWG wire across the span each at an internal of 5 mtr. for cross lacing complete in all respects including men & material,T&P proper completion of work as per direction of Engineer in charge as per SIDC Sch. No. 12.01 |
| 11 | Supply & fixing of anticlimbing device fabricated grom G.I flat of 25mmx6mm size in a sape of ring of the pole size, having G.I flat pointed fins of the length 225 mm in 8 nos. and also barbed wire in 200 mm length above the said ring including material for proper completion of work as per direction of Engineer in charge |
| 12 | Supply & fixing of D clamp of size 50x6 mm flat iron on ST poles with nuts,bolt and washers etc. complete in all respect as per UPPWD Sch. No. 623(Including earth clamp) |
| 13 | Supply & fixing of 100 x 110 mm shackle insulator 100 x 80 mm pin insulator including GI bolt spindle, nuts etc. as pre UPPWD Sch. No. 621 |
| 14 | Supplying & fixing of 230 mm x32 mm x 1.5 mm galwanised steel strips including holes for shackle insulators pinsand bolts etc. complete in all respect.UPPWD 622 |
| 15 | Supply and fixing of danger board fabricated from 10 gauge M.S.sheet as per I.E.Rules.UPSIDC E27.01 |
| 16 | Painting of ST pole and all mountings on it with two coats of aluminium paints with an under coat of red oxide paint above 10 Mtr. support above the ground level as per direction of Engineer in-charge of work/site including T&P, men & material required for proper completion of work.UPSIDC Sch. No.20.(2) |
| 17 | Supply & fixing of LED street light fittings having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt LED light confirming to IP 66 and above protection complete in all respect as per UPPWD Sch. No.1424 CAT- AA (Bajaj /Philips/Crompton/Wipro Make) |
| 18 | Supply and fixing of 32 mm dia 1.20 mtr long GI pipe bracket including bend pipe ,2 nos 50x6 mm ms clamp in all respects. |
| 19 | Supply & wiring of submain with 2 Nos.of 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P reuired for proper completion of the work as directed as site by Engineer I/C as per UPPWD Sch. No.289 |
| 20 | S/F of following capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint consisting of timer switch TSO 100 series with cintractors HRC fuses, isolating switch metering instuments box with CTS etc. as per UPPWD Sch. No. 807(d-ii)25 Amp.TPN) |
| 21 | Supply & laying 16 sq mm 4 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V grade in existing HDPE/GI pipe &Surface laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(i) & 507 (Polycab/Havells/ Grandlay/Gloster/KEI Make) |
| 22 | Supply & laying 25 sq mm 3.5 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V grade in existing HDPE/GI pipe &Surface laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(j) & 507 (Polycab/Havells/ Grandlay/Gloster/KEI Make) |
| 23 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer - incharge as per UPPWD sch. no. 503 (i) 16 sq. mm 4 core |
| 24 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer-incharge as per UPPWD sch. no. 503 (k) 25 sq. mm 3.5 core |
| 25 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 16 sq. mm |
| 26 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer incharge as per UPPWD sch. No. 504 (f) 25 sq. mm |
| 27 | Supply & Laying of 63 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect. |
| 28 | Supply & Fixing of 25 x 3 mm GI strip from earth electrode directly in the ground as required complete in all respect. as per UPPWD Sch. 716 |
| 29 | S/L of 185 sq. mm 3 core cable standard aluminium conductor XLPE (cross linked polyethylene) insulated PVC bedded glavanised flat steel strip armoured cables confirming to IS 7098 (Part-II) with latest amendments, 11 KV grade at a depth of 900 mm below ground level. (When cable is passed through DWC/MS/GI pipe)The armouring of cable shall be properly connected with earth conductor by clamp etc.(Gloster/KEI /Havells/Grandlay/Polycab make) |
| 30 | S/F of outdoor/indoor type 11 KV jointing kit heat shrinkable type for 11 KV cable including cost of all material, labour, T&P etc. for proper completion of work. (Raychem, Denson/Birla /3M make) for 3x185 sq.mm cable. |
| 31 | Supply & laying of 160 mm dia (OD-160 mm & ID-136 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc.confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender