Tender For 1. Construction Of Girls Mini Community Sanitary Complex At Anupp Attu Periya Colony Pues @ Anupp Attu Panchayat In Minjur Panchayat Union Type - 3 Under Sbm - Aip- Phase -Ii/2026 - 2027/Mjr02
Tender Value
6.84 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
11 days left
EMD
7000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for 1. Construction Of Girls Mini Community Sanitary Complex At Anupp Attu Periya Colony Pues @ Anupp Attu Panchayat In Minjur Panchayat Union Type - 3 Under Sbm - Aip- Phase -Ii/2026 - 2027/Mjr02
BOQ
| Sl. No. | Item Description |
| 1 | 1. CONSTRUCTION OF GIRLS MINI COMMUNITY SANITARY COMPLEX AT ANUPPAMPATTU PERIYA COLONY PUES @ ANUPPAMPATTU PANCHAYAT IN MINJUR PANCHAYAT UNION TYPE - 3 UNDER SBM - AIP- PHASE -II/2026 - 2027/MJR02 |
| 2 | Earth work excavation and depositing on bank with initial lead and lift in hard gravelly soil, hard stiff clay, black cotton soil, hard red earth,shales, murram, and earth muds with 50% fair sized boulders as per SS 20B for narrow foundation complete as per standard specification. |
| 3 | Filling with M.Sand including cost and coveyance of all materials to work site and all labour charges etc., complete as per standard specification. |
| 4 | Cement Concrete 1:4:8 mix using 40mm metal including cost and conveyanceof all materials to work site and all labour charges etc., complete as per standard specification. |
| 5 | Supplying and erecting for sides & soffits including supports and strutting for plane surface in all floors including cost and conveyance and all labour charges etc., complete as per standard specification.up to basemnet |
| 6 | For Sub Structure |
| 7 | For Super structure |
| 8 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 9 | Reinforced Cement Concrete 1:1-1/2:3 (One Cement, One and a Half crushed stone M.Sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three M.Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. |
| 10 | Below Basement |
| 11 | Above Basement |
| 12 | Brick work in C.M 1:5 mix using country bricks incuding cost and conveyance and all labour charges etc., complete as per standard specification |
| 13 | Below Basement |
| 14 | Above Basement |
| 15 | Refilling in foundation and basement with excavated earth in layer of not more than 15cm thick |
| 16 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping theputty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work |
| 17 | Plastering with cement mortar 1:5, 12mm thick including cost and conveyance and all labour charges etc., complete as per standard specification. |
| 18 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone M.Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Using anti-skid tiles (Observed Data) |
| 19 | Dadooing walls with glazed tiles of size 150x150x6mm neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 20 | Paving the Top of roof with Solar reflective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three M.Sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works) |
| 21 | Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). |
| 22 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 23 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floorsexcluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 24 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \\"P\\" or \\"S\\" trap conforming to BIS with crushed stone M.Sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone M.Sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 25 | Supplying and fixing in positon Indian make white glazed earthern ware squatting type urinal of best quality and approved make including dismantling masonry, if necessary nad re-doing the same tomoriginla condition, etc., complying with standard specifications . (The squatting type urinal should be got approved by the Executive Engineer before use on works). |
| 26 | Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat isprovided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat M.Sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at theends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop isprovided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete. |
| 27 | Supply and Fixing of New PVC Door Size (0.75x2.10) including cost and conveyance of all materils to site and labour charges etc. complete. Solid panel PVC door with frame |
| 28 | Supplying and fixing 0.9 m dia RCC Ring for leach pit including all the charges etc complete |
| 29 | Supplying and fixing RCC Cover Slab including all the charges etc complete |
| 30 | SANITARY ARRANGEMENTS |
| 31 | 110mm dia pvc pipe |
| 32 | 110mm dia pvc Elbow |
| 33 | 110mm dia pvc Tee |
| 34 | Supply and providing 2000 litres capacity Priming Tank made up of PVC Tank ( |
| 35 | ELETRICAL ARRANGEMENTS |
| 36 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light / fan Point (for electronic regulator) (5 points per coil) (SD No.25) |
| 37 | Supply and fixing of 4'-18W LED tube with fitting inclusive of all charges SD NO : 444- |
| 38 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point SD38 |
| 39 | Supply and fixing of WT bulk head fitting with guard suitable for 11W CFL lamp with CFL (SD N0.83) |
| 40 | Supply and Run of 2 of 2.5 sq.mm (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade on 7/20 GI wire for service connection mains (SD No.64) |
| 41 | Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit (SD No. 125) |
| 42 | Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains SD 70 |
| 43 | Supply and fixing of 16A DP switch of 500V with matal clad with fuse and neutral (side handle) on suitable TW board with earth connection onlySD 142 |
| 44 | Supply and fixing of 3 Nos. 5A (3 pin and 2 pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) SD 139 |
| 45 | Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall SD 134 |
| 46 | Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work SD 222 |
| 47 | Provision for Name Board charges |
| 48 | GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column \\"BB\\" for all works in this package}(Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender