Tender For annual maintenance Watch And Ward And On/Off Of Street Light Installed On Dividing Road Between Sec-2-64, 64-65, 63-64, 61-62, 62-63, 62-65, 56-56A, Hsvp Town Park And Sports Complex Sector-12 At Faridabad (For The Year 2026-27). (Edc). A/
Tender Overview
Project Description
Tender for annual maintenance Watch And Ward And On/Off Of Street Light Installed On Dividing Road Between Sec-2-64, 64-65, 63-64, 61-62, 62-63, 62-65, 56-56A, Hsvp Town Park And Sports Complex Sector-12 At Faridabad (For The Year 2026-27). (Edc). A/Cost Rs.17.79 Lacs E/Money Rs.35580.00 Time Limit : 8 Months
BOQ
| Sl. No. | Item Description |
| 1 | [23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA |
| 2 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA |
| 3 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole |
| 4 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. |
| 5 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. |
| 6 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. |
| 7 | [24.13.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.) |
| 8 | [24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) |
| 9 | [24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) |
| 10 | [24.2.9.4]LT CABLE 9.4. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 10 to 16 sqmm Cable 3 to 4 Core |
| 11 | [24.2.9.5]LT CABLE 9.5. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 25 sqmm to 50 sqmm Cable 3 to 4 Core |
| 12 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia |
| 13 | Comprehensive A/Mtc. of public addressing system including 135 Nos. 40 Watt speakers, power amplifier, audio distribution box, CD player with pen drive, PVC 2.5sqmm x 3core, HDPE pipe and all other equipments, operation of PA system and labour part complete in all respect and maintaining the system in working condition for 365 days x 24 hours. (Rate without GST) |
| 14 | Repair and Maintenance charges of LED street light / Flood lights points from 225 watt to 400 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect upto the entire satisfaction of engineer in charge of work. (Rate without GST) |
| 15 | Repair and Maintenance charges of LED street light / Flood lights points from 90 watt to 200 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. (Rate without GST) |
| 16 | Repair and Maintenance charges of LED street light points from 45 watt to 72 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. (Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. (Rate without GST) |
| 17 | Repair and Maintenance charges of sodium street light points and Flood lights 150/250/400 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. chock/lamp/ignitor/capacitor/lamp holder/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, Plier, safety belt, shoes etc.) on various sectors / master roads complete in all respect upto the entire satisfaction of engineer in charge of work. (Rate without GST) |
| 18 | Supply and erection of 2.5 sqmm x 3 core aluminum flexible cable PVC insulated and sheathed core round/flat cable 1100 volts each core having single solid aluminium conductor as per IS: 694, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. (Rate without GST)Make:- Havells/Polycab/Grandlay or make approved by DHBVN. |
| 19 | Supply and erection of 30mm2 PVC insulated ACSR conductor conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of Engineer-in-Charge. (Rate without GST) |
| 20 | Supply and erection of 63 Amps connection plate 4 pole for incoming and outgoing cable fitted with connector fixed on Bakelite sheet complete with nut and bolts complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. (Rate without GST) |
| 21 | Supply and erection of double arm bracket over-hang made out of galvanized iron, having canopy 0.60m long and 125 mm dia B-class and two nos. arms of length 1500mm each, made out of 50mm dia B-class G.I. pipe for street light fitting making an angle of 15° with horizontal plane with bracings of 25 mm dia G.I. pipe including all labour and material complete in all respect upto the entire satisfaction of Engineer-in-Charge. (Rate without GST) |
| 22 | Supply and erection of junction cover for octagonal poles made out of fiber sheet of size 1.0 sq feet complete with cutting and binding of covers with poles using transparent cello tape complete in all respect. (Rate without GST) |
| 23 | Supplying, installation, Testing and Commissioning of 120 Watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). (Rate without GST)Make- Philips/Bajaj/Panasonic/LT Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents