Housing Urban and Rular Development Local Bodies Closing in 1 days TDR #56602468

Tender For annual maintenance Watch And Ward And On/Off Of Street Light Installed On Dividing Road Between Sec-2-64, 64-65, 63-64, 61-62, 62-63, 62-65, 56-56A, Hsvp Town Park And Sports Complex Sector-12 At Faridabad (For The Year 2026-27). (Edc). A/

Issued by Local Bodies · Faridabad, Haryana
Tender Value
17.78 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
1 days left
EMD
35580
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Faridabad → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for annual maintenance Watch And Ward And On/Off Of Street Light Installed On Dividing Road Between Sec-2-64, 64-65, 63-64, 61-62, 62-63, 62-65, 56-56A, Hsvp Town Park And Sports Complex Sector-12 At Faridabad (For The Year 2026-27). (Edc). A/Cost Rs.17.79 Lacs E/Money Rs.35580.00 Time Limit : 8 Months

BOQ

Name of Work:- A/Mtc. watch and ward and ON/OFF of street light installed on dividing road between Sec-2-64, 64-65, 63-64, 61-62, 62-63, 62-65, 56-56A, HSVP Town Park and Sports Complex Sector-12 at Faridabad (for the year 2026-27). (EDC). A/Cost Rs.17.79 Lacs E/Money Rs.35580.00 Time Limit : 8 Months
Sl. No. Item Description
1[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA
2[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA
3[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
4[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
5[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
6[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
7[24.13.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.)
8[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.)
9[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.)
10[24.2.9.4]LT CABLE 9.4. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 10 to 16 sqmm Cable 3 to 4 Core
11[24.2.9.5]LT CABLE 9.5. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 25 sqmm to 50 sqmm Cable 3 to 4 Core
12[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
13Comprehensive A/Mtc. of public addressing system including 135 Nos. 40 Watt speakers, power amplifier, audio distribution box, CD player with pen drive, PVC 2.5sqmm x 3core, HDPE pipe and all other equipments, operation of PA system and labour part complete in all respect and maintaining the system in working condition for 365 days x 24 hours. (Rate without GST)
14Repair and Maintenance charges of LED street light / Flood lights points from 225 watt to 400 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect upto the entire satisfaction of engineer in charge of work. (Rate without GST)
15Repair and Maintenance charges of LED street light / Flood lights points from 90 watt to 200 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. (Rate without GST)
16Repair and Maintenance charges of LED street light points from 45 watt to 72 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. (Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. (Rate without GST)
17Repair and Maintenance charges of sodium street light points and Flood lights 150/250/400 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. chock/lamp/ignitor/capacitor/lamp holder/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, Plier, safety belt, shoes etc.) on various sectors / master roads complete in all respect upto the entire satisfaction of engineer in charge of work. (Rate without GST)
18Supply and erection of 2.5 sqmm x 3 core aluminum flexible cable PVC insulated and sheathed core round/flat cable 1100 volts each core having single solid aluminium conductor as per IS: 694, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. (Rate without GST)Make:- Havells/Polycab/Grandlay or make approved by DHBVN.
19Supply and erection of 30mm2 PVC insulated ACSR conductor conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of Engineer-in-Charge. (Rate without GST)
20Supply and erection of 63 Amps connection plate 4 pole for incoming and outgoing cable fitted with connector fixed on Bakelite sheet complete with nut and bolts complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. (Rate without GST)
21Supply and erection of double arm bracket over-hang made out of galvanized iron, having canopy 0.60m long and 125 mm dia B-class and two nos. arms of length 1500mm each, made out of 50mm dia B-class G.I. pipe for street light fitting making an angle of 15° with horizontal plane with bracings of 25 mm dia G.I. pipe including all labour and material complete in all respect upto the entire satisfaction of Engineer-in-Charge. (Rate without GST)
22Supply and erection of junction cover for octagonal poles made out of fiber sheet of size 1.0 sq feet complete with cutting and binding of covers with poles using transparent cello tape complete in all respect. (Rate without GST)
23Supplying, installation, Testing and Commissioning of 120 Watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). (Rate without GST)Make- Philips/Bajaj/Panasonic/LT Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56602468
AUTHORITY Local Bodies
TENDER VALUE 17.78 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Haryana Urban Development Authority
Work Description Tender for annual maintenance Watch And Ward And On/Off Of Street Light Installed On Dividing Road Between Sec-2-64, 64-65, 63-64, 61-62, 62-63, 62-65, 56-56A, Hsvp Town Park And Sports Complex Sector-12 At Faridabad (For The Year 2026-27). (Edc). A/Cost Rs.17.79 Lacs E/Money Rs.35580.00 Time Limit : 8 Months
Basic Detail
Tender No 202611F2BDFE 10D6 426D AFFE A43EA5DCE95B364HSV
Bidding Type Tender
Location
City Faridabad
State Haryana
Key Dates
Publish Date 22 Jul 2026
Submission Date 28 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 17.78 Lakhs
Tender Fee 500
EMD 35580
Exemption Available
Document List
BOQ_615023.xls
dde09014-5c9d-459d-bf14-a0d161484ab0.html
OT0171072.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_615023.xls

html

dde09014-5c9d-459d-bf14-a0d161484ab0.html

pdf

OT0171072.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders