Tender For General-Supply And Installation Of 8Kwp On Grid Solar And Connected Electrical Works Erumeli Rest House,Kottayam-Sitc Of Solar Panel At Rest House-General Electrical Work
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Jul 2026
6 days left
EMD
18946
Bank guarantee accepted
Document Fee
1675
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Supply And Installation Of 8Kwp On Grid Solar And Connected Electrical Works Erumeli Rest House,Kottayam-Sitc Of Solar Panel At Rest House-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | ON grid solar |
| 2 | OD279533/2024-2025:Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of200-1000 V DC Input voltage range or nearest range and 400V AC, three phase, 4wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiencynot less than 97%, total harmonic distortion less than 3% and suitable for ambienttemperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequencylevel to suit the Grid Voltage Frequency and adustiable for connecting time to grid asper KSEB norms, including Data Monitoring System complete with accessorieswifi/LAN connecting and connected application software etc. fixing on wall usingwall brackets and giving all connection as required |
| 3 | OD279532/2024-2025:Supply and providing Solar Photovoltaic Module Mono Perc Half Cut of capacity540 Wp or nearest size, manufactured in India, conforming to IS 14286/IEC 61215,IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversionefficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not beless than 90% at the end of 10 years and 80% at the end of 25 years. fixing onexisting steel frame work using nut bolts/screws etc in suitable direction at sitecondition and giving connection and inter connection wire tied using suitable steelwire tie as per the system string design and direction of department staff |
| 4 | OD279534/2024-2025:Supply and providing wall mounted AC DB for on grid solar system for connectingInverter AC side consists of a). Poly carbonate Enclosure IP65 protection withtrasperant front cover with hinged door and termination arrangement, b). SPDUp1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection usingsuitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection andDB fixing on wall using suitabel screws and plugs ets as required. |
| 5 | OD279535/2024-2025:Supply and providing wall mounted DC DB for on grid solar system for connecting2Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65protection with transparent front cover with hinged/screws door and terminationarrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -veincomer side, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585VDC, In 15kA, Imax 40kAand giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitablescrews and plugs ets as required. |
| 6 | OD279525/2024-2025:Supplying and drawing 1run x 4 sq. mm PVC insulated tinned copper conductor, single core Solar DC cable in the existing surface / recessed steel/ PVC conduit as required. |
| 7 | OD279528/2024-2025:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6545) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required. |
| 8 | 2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole and neutral |
| 9 | OD279527/2024-2025:Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in the existing meter board complete with connections, testing and commissioning etc. as required (including testing if required, test certificate for submitting KSEB). |
| 10 | OD279523/2024-2025:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 10Sqmm single run |
| 11 | OD279529/2024-2025:Supplying and fixing Three phase 4wire KWh CT Net meter, 415V, electronic type in the existing meter board complete with connections, testing and commissioning etc. as required for charging On grid plant after dismantling the existing KWH meter (including testing if required, test certificate for submitting KSEB). |
| 12 | 90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap |
| 13 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid |
| 14 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 15 | 90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run |
| 16 | 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 17 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 18 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 19 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 20 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 21 | OD279524/2024-2025:Supply and fixing 2 x 25mm X 3 mm copper strip test joint for the earthing system. |
| 22 | OD279530/2024-2025:Supply and providing 25x3mm brass bolt |
| 23 | OD279522/2024-2025:Supply and providing 25x6mm brass bolt |
| 24 | OD279531/2024-2025:Supply and providing 12x3mm brass bolt |
| 25 | OD279526/2024-2025:Supply and providing Copper Bounded lightning arrester single spike " Air-termination rod " are placed on top of the structure using suitable base plate and nut bolt and giving connection to existing lightning down conductor etc as required |
| 26 | 90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip |
| 27 | 90.3.17.2:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe |
| 28 | OD279536/2024-2025:Supply and connecting MC4 Wire Connector Male/Female for Solar Panels, IP67 Waterproof Cable ConnectorsIP68 rating, rated voltage - 1500VDC (IEC) / DC (UL), Ambient Temperature - -40°C to +90°C (EC)Contact Material: Brass/Copper, Tin-Plated |
| 29 | OD285937/2024-2025:Supply and fixing 32 A AC3, MCX 03, 4 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required- |
| 30 | OD285940/2024-2025:Supply and fixing DPDT glass relay(240V/16A) with base in the existing enclosure and giving connection as required- |
| 31 | OD285960/2024-2025:Supply and renewing Single phase preventer relay( L&T make/equivalent) and giving connections etc as required- |
| 32 | OD286045/2024-2025:Supply and providing 250x200x105mm syntex make junction box |
| 33 | OD279537/2024-2025:Supply and fixing D-Link DAP-1325 Router 300 Mbps WiFi Range Extender or EquivalentType: Range Extenders/Repeaters,300 Mbps Speed,Frequency: 2.4 GHz,External Antenna |
| 34 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 35 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 36 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 37 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 38 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 39 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 40 | OD279520/2024-2025:Charges for preparation of Electrical Drawing per A2 sheet first copy for sanction from Electrical inspectorate if required (DG approved installation hence additional and alteration required ) |
| 41 | OD279521/2024-2025:Copying charges for additional copies per A2 sheet |
| 42 | Civil |
| 43 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 44 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 45 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender