Tender For Providing Repair & Maintenance Of Electrical Services Under Electrical Sub-Division Una Distt. Una (Hp) (Chargeable To Chc Beetan)
Tender Value
2.94 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
4 days left
EMD
5900
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Una → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Repair & Maintenance Of Electrical Services Under Electrical Sub-Division Una Distt. Una (Hp) (Chargeable To Chc Beetan)
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVCconduit as required. Make:- KEI/Anchor/ Polycab/Finolex as approved by Engineer -in -charge . |
| 2 | 3 X 1.5 sq. mm |
| 3 | 3 X 4 sq. mm |
| 4 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.Make:- Anchor/L & T/SSK . |
| 5 | 5/6 amps switch |
| 6 | 5/6 amps socket |
| 7 | 15/16 amps switch |
| 8 | 15/16 amps socket |
| 9 | Bell push |
| 10 | fan regulator |
| 11 | Supplying and fixing metal box of 200mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 2 nos. 3 pin 5/6 amps Piano socket outlets and 2 nos 5/6 amps Piano switches, connection, painting etc. as required. Make:- Anchor/L & T/SSK . |
| 12 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS on including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make:- Anchor/L & T/SSK . |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Make:- Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Er-In-Charge. (five year warranty ) |
| 14 | 5/6 amp Modular switch |
| 15 | 3 pin 5/6 amp socket outlet |
| 16 | 16/20 amp Modular switch |
| 17 | 6 pin 15/16 amp socket outlet |
| 18 | 3 Pin top plug 5 amp |
| 19 | 3 Pin top plug 15 amp |
| 20 | Supplying and fixing of following sizes of PVC conduit Heavy duty minimum thickness 1.6 mm along with accessories insurface/ recess including painting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required. Make:- Diplast/BEC/AKG/ Polycab/ Anchor or as approved by Er-In-Charge(for Networking, CCTV, Fire alarm etc.) |
| 21 | 25 mm dia |
| 22 | Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required. |
| 23 | Ding Dong bell |
| 24 | Supplying and fixing of fan capacitor 2.5 microfarad complete in all respect as required |
| 25 | Supplying and fixing Geyser thermostat including testing and commissioning etcas required . |
| 26 | supplying and fixing PVC tape roll. |
| 27 | supplying and fixing Bell indicator 12 way |
| 28 | Providing, laying and fixing of PVC round sheathed 2 core 1.5 sqmm fr copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :- -Finolex/Havell/Polycab/KEI. |
| 29 | Providing, laying and fixing of PVC round sheathed 2 core 2.5 sqmm fr copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :-Finolex/Havell/Polycab/KEI. |
| 30 | Supplying and fixing , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.)including five year warranty all rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble. Make:- L&T Cat. No. (SL96072, Legrand, Hager, ABB as approved by Er-In-Charge (five year warranty) |
| 31 | Single pole 5-32 amp |
| 32 | Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of double poles in the existing MCB DB complete with connections etc. including five year warranty all rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble.-Make:- L&T, Legrand, Hager, ABB as approved by Er-In-Charge (five year warranty) |
| 33 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,10 KA residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. including five year warranty all rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble.Make:- L&T, Legrand, Hager, ABB as approved by Er-In-Charge (five year warranty) |
| 34 | 40 AMP |
| 35 | 63 AMP |
| 36 | Providing services of helperT/ Mate for repair running /maintenance /operation for various electrical services under Electrical Sub Division Una as and when required . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓