Tender For Bifurcation Of Water Supply Scheme Ferozpur Khurd And Kunda Block Gharota Distt. Pathankot ( Tubewell Based) (Under Head:- Nabard-Xxxi/State Share/4215) Providing & Installing Of New Tubewell Of Size 200Mm I/D Straight Upto 110 Mtr Depth W
Tender Overview
Project Description
Tender for Bifurcation Of Water Supply Scheme Ferozpur Khurd And Kunda Block Gharota Distt. Pathankot ( Tubewell Based) (Under Head:- Nabard-Xxxi/State Share/4215) Providing & Installing Of New Tubewell Of Size 200Mm I/D Straight Upto 110 Mtr Depth With Direct Rotary Rig, Construction Of Pump Chamber 3.05Mx3.70M With W.C, Providing And Installing Sub Set 4.50 Lps 44 Mtr Head, providing and Fixing Solar Panel Energy System, Construction Of Ohsr 50000 Ltr Capacity Having Staging Height 17 Mtr & Fsl 20 Mtr, providing and Fixing Ci Delivery, Providing And Installing Disinfection Unit, Upvc Rising Main 10Kg, Sluice Valve & Chamber, Development Of Water Works, Providing Laying Jointing Testing Of Upvc Pipe (Type-A) Including Excavation, Specials And Back Filling & providing & Fixing Of Sluice Valve & Haudi, Dismantling And Restoration Of Brick Paving, Concrete Road And Interlock Tile, providing and Fixing House Hold Connection, Water Meter & Bulk Meter Etc Complete In All Respect.
BOQ
| Sl. No. | Item Description |
| 1 | Drilling of 400mm dia bore with Direct Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect. (0 to 110mtr BGL) in Area of District Pathankot, Talwara and Nagal.a) Drilling of 400mm dia bore with Direct Rotatry Rig Upto 200 m depth BGL. |
| 2 | 1. Erection and dismantling of boring plant including all arrangement for the transportation of the boring equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work. Pits for collection of water and water for drilling tubewell to be arranged by the firm/contractor at site at his own cost. |
| 3 | 2. In case the bore is converted into a tubewell payment of bore shall be made up to the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore paid at the rate of beyond margin shall be paid at the rate of test bore drilling. |
| 4 | Supplying and lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS Code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 5 | 200mm nominal diameter (weight 33.6 Kg per meter) 6.40mm thickness |
| 6 | Supplying, fixing, lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest with ISI Marked dully welded with suitable grade S.S welding electrode to lower the strainer into Tubewell bore. |
| 7 | 200mm internal diameter (slot size 0.75mm) 6.30 mm thickness |
| 8 | Supplying, fixing lowering of stainless steel socket as per IS: 8110-2000 or latest ISI Marked dully welded with suitable grade S.S welding electrode to lower the strainer into Tubewell Bore complete in all respects. |
| 9 | (200mm) i/d |
| 10 | Supplying and fixing of bail plug of MS pipe complete with inverted u-hock attached to the bottom plug complete in all respects (200mm) i/d weight 33.6 kg p/m) 6.40 mm Thick. |
| 11 | Supplying and Fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 12 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. 200mm internal diameter |
| 13 | Supplying & fixing of M.S Clamp of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 14 | Supplying, lowering & fixing of M.S Special Socket to connect S.S. Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. 200mm internal diameter |
| 15 | Supplying at site Wooden Box of suitable size with Lid & locking arrangement for preserving strata sample collected from the bore. |
| 16 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 17 | Development and stabilizing of the tube well with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 18 | Capacity of Air compressor 300 cfm at 250 PSI |
| 19 | Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge |
| 20 | Collection of Water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 21 | Testing of water sample for heavy metal testing from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc) |
| 22 | Provision for Sanitary Clay seal (as per BIS Code IS 2800:2019) including sterilization of tubewell |
| 23 | PUMP CHAMBER |
| 24 | Construction of Pump Chamber size 3.05 m x 3.70m without gravel pit but including electric wiring as per DWSS standard design and analysis complete in all respects. Including provision for Sanitary Latrine in pump chamber for foundation and plinth of WC rooms including flooring ,PVC pipes , Junction Box , 1 No. Leach Pit , Super structure WC room etc. |
| 25 | PUMPING MACHINERY |
| 26 | Providing & Installing Testing & Commissioning of one No. Electrically driven Submersible Pumping set of reputed make capable of delivering 4.50 LPS against a head of 44 mtr along-with electric panel board consisting of electric appliance such as automatic Starter, Main Switch. Volt Meter, Ampere Meter, ELCB, Shunt Capacitor, Single Phase Preventer, Indicating Lamps, MVB/MCCBs etc. including G.I Column Pipe of suitable size 65mm (in 3 m Lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (of reputed make) complete in all respects. As per ISI 1239-2004 |
| 27 | Rate of Motor with Pump |
| 28 | Panel Board |
| 29 | Submersible cable Size 2.50mm2 |
| 30 | Column Pipe (G.I) 65 mm i/d |
| 31 | SOLAR PANEL ENERGY SYSTEM |
| 32 | Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects. |
| 33 | C.I.FITTING INSIDE PUMP CHAMBER |
| 34 | Providing & Installing 100 mm dia delivery main (from Tube-well to duck foot bend including cost of C.I.D/F Pipes, D/F Sluice Valves, D/F Non Return Valve & Specials as C.I. Bends, Tail Piece Tees, Pressure gauge, Air Valve,,V notch haudi etc. inside the Pump chamber as per DWSS standard design and analysis complete in all respects. (Annexure-3) As per IS1536-2001 & 1538-1993 reaffirmed 1999. |
| 35 | Disinfection Unit: |
| 36 | Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution/ sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. |
| 37 | RCC OHSR |
| 38 | Constructing of 1 No. RCC OHSR of 50KL Capacity having staging Height 17 mtr. & FSL 20 mtr from formation level complete with external RCC Stair case with landing slabs at each staging RCC roof, ventilator single manhole cover lightning conductor etc. complete as described in schedule No.3 providing and fixing CI/ DI K9 D/F expansion Joints, bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing Duck foot bends, Conforming IS-9523 with latest amendments) and D1 12 D/F sluice Valve duty ISI marked (IS 14846-2000 Or latest on each with inlet outlet and scour pipes. Including Providing and Installing inlet outlet scour pipe and overflow DI K-9 double flanged pressure pipes centrifugally cast as per IS 8329-2000 with latest amendment duly ISI marked from bottom dome to duck foot Bond and further up to 2.75 mtr. As per detail specification TMT steel & painting of all complete shall he included in cost & P/F aluminum ladder inside/steel ladder outside tank of the OHSR including testing of soil bearing capacity tested from the reputated institute such as PEC Chandigarh / TTT Sector-26, Chandigarh GNEC/Ludhiana/Thapar Institute of Engineer and Technology Patiala Complete in all respect SBC shall be tested in the presence of Engineer or his representative as per specifications. (The specifications & drawing are based on safe bearing capacity of Soil is not less than 8.75 tons per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm. The contractor shall summit his own design keeping in view seismic Zone-IV for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard, drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including overflow houdi, including providing and fixing water Level indicating system and construction of plinth protection around OHSR with masonry toe wall with including foundation depth, earthing cc 1:8:16 with 40mm stone aggregate and conglomerate floor 40mm with CC 1:24 as per DWCC specification. Providing & applying, integral crystalling slurry of hydrophilic in nature for water proofing management for vertical and horizontal surface and swellable type water stop tape. |
| 39 | uPVC RISING MAIN |
| 40 | Providing, laying, fixing & jointing of uPVC pipe & special 10kg/sqcm type A as per ISI - 4985-2021 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation& back filling as per analysis A 14 complete in all respects. |
| 41 | 110mm o/d (Mechanical) |
| 42 | Sluice Valve & Sluice Valve Chambers |
| 43 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). |
| 44 | 100 mm Nominal Bore (N.B.) |
| 45 | Construction of brick masonry sluice valve chamber size 0.90m x 0.90m complete in all respect as per standard Design of DWSS. |
| 46 | DEVELOPMENT OF WATER WORKS SITE. |
| 47 | Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 9.34 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects |
| 48 | Providing & Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4mm dia fencing pole size at bottom 4\\"x4\\", size top 3\\" x 4\\", Length 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. |
| 49 | Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm complete in all respect. |
| 50 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects. |
| 51 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22 m x 1.37 m as per DWSS standard Drawing and analysis. |
| 52 | Construction of Foot Path with masonry toe wall & earth filling and Cement Concrete 1:8:16 with 40 mm gauge stone aggregate, 40 mm thick cement concrete topping 1:2:4, inside water works as per DWSS standard Drawing and analysis. |
| 53 | Providing & fixing MS sign Board as per DWSS standard design and analysis. |
| 54 | Providing, Laying , fixing & jointing of uPVC Pipes (Type-A) as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (6Kgf./sqcm) |
| 55 | Excavation with JCB |
| 56 | uPVC Pipe 63 mm o/d |
| 57 | uPVC Pipe 90 mm o/d |
| 58 | uPVC Pipe 110 mm o/d |
| 59 | Excavation with Manually |
| 60 | uPVC Pipe 63 mm o/d |
| 61 | uPVC Pipe 75 mm o/d |
| 62 | uPVC Pipe 90 mm o/d |
| 63 | uPVC Pipe 110 mm o/d |
| 64 | Providing, laying, jointing, fixing & testing of GI Pipe and specials Class-B including cost of material, complete in all respects including all taxes |
| 65 | GI Pipe 25mm i/d (without excavation) |
| 66 | GI Pipe 32mm i/d (without excavation) |
| 67 | GI Pipe 40mm i/d (without excavation) |
| 68 | GI Pipe 50mm i/d (without excavation) |
| 69 | GI Pipe 65mm i/d (without excavation) |
| 70 | GI Pipe 80mm i/d (without excavation) |
| 71 | GI Pipe 100mm i/d (without excavation) |
| 72 | Making Connection with existing pipe line including cutting cost of D-Joint, labour for fixing specials excavation bailing out etc. |
| 73 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). |
| 74 | 100mm i/d |
| 75 | 80mm i/d |
| 76 | Construction of masonry sluice valve chamber size 0.60m x 0.60m complete in all respect as per standard design DWSS. |
| 77 | Construction of masonry sluice valve chamber size 0.90m x 0.90m complete in all respect as per standard design DWSS. |
| 78 | Provision of Rectifying the Leakage of existing Pipe Line |
| 79 | 90mm o/d |
| 80 | Dismantling and restoration brick paving complete in all respect |
| 81 | uPVC Pipe 63 mm o/d |
| 82 | Contractor shall be quote rates only for dismantling of mettaled road & back filling with excavated earth fully compacted the restoration of the mettaled road to its original condition will be done by the concerned department i.e. PWD (B&R) PMB/Panchayati Raj) |
| 83 | 90mm o/d |
| 84 | Dismantling and restoration of Cement Concrete Road complete in all respect |
| 85 | uPVC Pipe 63 mm o/d |
| 86 | uPVC Pipe 90 mm o/d |
| 87 | Dismantling and restoration of Interlock Tile complete in all respect |
| 88 | uPVC Pipe 90 mm o/d |
| 89 | uPVC Pipe 110 mm o/d |
| 90 | Dismantling and restoration of Interlock Tile & Only Dismentling of Cement Concrete complete in all respect |
| 91 | uPVC Pipe 63 mm o/d |
| 92 | uPVC Pipe 75 mm o/d |
| 93 | House water connection |
| 94 | Providing Proposed water connection to house hold up to wall with providing laying, jointing, testing MDPE pipe line 15mm o/d (Below G.L) & G.I. 15mm i/d (Above G.L.) including cost of specials such as tees, bends, sockets, elbow etc cutting, threading and testing trenchs in the ground and ISI 15mm i/d GM ferrule as per IS 2692 and 3\\" i/d clamp with C.I. bib cock 15 mm i/d as per IS 210 with stainless steel spindle of approved make complete with excavation |
| 95 | Water connection on Proposed line |
| 96 | Water Connection on Replaced pipe line (shifted) |
| 97 | Water Connection on Existing pipe line (including) +Dismantling and restoration of Interlock Tile and only Dismentling of CC complete in all respect. |
| 98 | Water Connection on Existing pipe line+ includingDismantling and restoration of Cement Concrete Road complete in all respect. |
| 99 | Water Connection on open G.I Pipe Line |
| 100 | Water MeterProviding fixing & jointing water meter (Multi jet) in G.I Pipe including cutting and threading pipe and making long screw etc inc. cost of G.I jam nut complete (15mm) P/F gun metal peet valves (Heavy Pattern) with hand wheel complete in all respect.Note:- The Contractor will ensure that the water meters will be procured only from those manufacture's who has obtained manufacture's licence from legal Metrology Dept, Punja. Further, the contractor has to submit a certificate regarding inspection of water makes as per provising of Legal metrology act, 2009 prior to their installation and ensure compliance to the provisions of Legal Metrology Act. |
| 101 | Bulk MeterProviding & Installing of Bulk Meter inside water works including rubber jain, Nut Bolts, Cutting and threading, piece for fixing Bulk Meter including carriage complete in all respects (ISI Make) Size 100 mm i/d |
| 102 | Environmental Management Charges |
| 103 | Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. |
| 104 | Digging of pits in all kinds of soil &refilling the same , with the excavated earth mixed with well decayed farm yard manure @30% of pit volume and insecticide for termite control. |
| 105 | Supplying and planting permanent trees in prepared pits and watering |
| 106 | Planting seasonal flower in bedsPlanting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row |
| 107 | Painting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row |
| 108 | Providing for one way stand post with Khura complete in all respects. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender